PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

REV-01
CGI SHEET ROOFING
EXISTING /PROPOSED BUILDING
Solar System
W.TANK W.TANK
Solar System
PLAN OF SH.RANVIR SINGH S/O
STRUT PURLING RAFTER WATER 408
STORAGE TANK 5000LTS CAPACITY SH.BUDHI SINGH ON KH NO 294 /260
AT MOHAL BANREDU TEH &

2.70
P.G.I.GUTTER
DISTT.SHIMLA (H.P)
ARCHITECTURAL NOTES.
R.W.PIPE
Stair Case 1 all dimensions are in Mt.,unless other wise specified.

3.00
0.45M CHAJJHA T =0.25
R =0.187 2 all dimensions are to be read & not measured.
Bed Room Drg.cum/Dining
Passage Bed Room
BRIEF SPECIFICATION:-

11.70
RCC BEAM 0.30X0.30M

1.foundation should be laid up to hard strata.


RCC SLAB 0.10CM THICK 2. super structure shall be of 1st.class brick work.

3.00
3. C. conc. flooring in all floors.
Bed Room Bed Room
4. Half brick masonary in 1:4.
Passage Bed Room
COLUMN 0.30X0.30M
5. Cement plastering in 1:6 both side.
6. All wood work shall be in 2nd class deodar work.
7. CGI sheet roofing over steel truss.
3.00
FALSE CEILING

3.00
SOLAR PASSIVE FEATURES:-
Bed Room Passage Bed Room Bed Room
1.South orientation to gain the maximum sun heat in winters.
2. Air lock lobby.
NSL 3. Maximum glazing in south side.

3.00
NSL R/Wall
4. Minimum glazing in north side.
5. Double glazing in north side.
6. 24cm thick wall or cavity wall over all.
FRONT SIDE ELEVATION SECTION AT A-A SECTION AT B-B 7. Solar water heating system on roof top.
VALLEY SIDE ELEVATION R/Wall 8. Photovoltic panel on roof top.

SCHEDULE OF AREA:-
TOTAL PLOT AREA 154.00 Sq.mt.
F.A.R. 1.75x154.00=269.50 Sq Mt.
r 1. BUILT UP AREA AT G.R FLOOR = 93.40 Sq.mt.
Bazza
kkar
TO La 93.40 Sq.mt.
SECOND FLOOR OF DEVIATION AREA:- TO Dhalli
2. BUILT UP AREA AT FIRST FLOOR =

3. BUILT UP AREA AT SECOND FLOOR = 76.50 Sq.mt.


0.62

Existing Building
Existing Building 4. TOTAL COVERED AREA AT ALL FLOORS = 263.30 Sq. Mt.
of Deepak Joshi

0.62x4.10=2.54 Sq.mt.
5. PERMISSIBLE AREA = 92.50 Sq. Mt.
A
SCHEDULE OF JOINERY:-
4.10

S.NO. NAME SIZE


1 D 1.00 X 2.40
R/Wall 2 D1 0.90 X 2.40
Sewer Line
3 D2 0.75 X 2.10
0.18
0.11

B 0.11+0.18/2x4.86=0.70 Sq.mt. (15.00M)


4 W 2.40 X 1.80

1.50
4.86
R.H.T.
1.20X1.50X2.50
1.50
5 W1 1.80 X 1.80
CAPACITY 4500LTS
6 W2 1.50 X 1.50

M WIDE
Existing Building
Septic Tank
W3 0.90 X 1.20
2.75

of Om Prakash 7

(12.00M
1.65X2.50X1.50M
0.24x2.75/2=0.33 Sq.mt. 8 W4 0.60 X 0.90

PATH 3.00
Capacity 6000lts
C
(11.00M)

UNDER

)
REFERNCE

0.24 R.C.C. Slab .10mm Existing Building


REFERENCES:-
0.74
R.C.C. Slab .10mm thick
Inlet Pipe
thick in C.C 1:2:4
Outlet Pipe
2.00
OF Ankur Sharma PROPOSED WORK

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT


R.C.C. Slab .10mm thick
Drain Line
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

EXISTING WORK
1.500

1.50

230mm thick brick Soak Pit 1.50m Dia


wall with cement .23TH. R.C.C. Wall
2.00m Depth
mortar Existing Building BOUNDARY
For Kitchen Waste (14.00M) of Ranvir Singh
1.11+0.74/2x4.10=3.79 Sq.mt.
0.750

C.C. 1:5:10
4.10

D C.C. 1:5:10

SECTION AT A-A C.C. 1:5:10


SITE PLAN (SCALE 1:200) Under Site Reff. SEWER LINE
SECTION OF SOAK PIT
SOAK PIT 1.25M DIA
DRAIN LINE
Outlet Pipe
LOCATION PLAN (NOT TO SCALE )
0.23

Inlet Pipe
1.11 ROAD / PATH
1.65

1.20

A A

SCALE OWNER
SECOND FLOOR TOTAL 1CM. = 100 CM.
0.23

PLAN OF SOAK PIT

DEVIATION AREA:- 7.36 Sqm FIRST FLOOR OF DEVIATION AREA:-


0.23 0.115 0.115 0.23
2.50

0.62 1CM. = 200 CM.


PLAN OF SEPTIC TANK
DETAIL OF SEPTIC TANK & SOAK PIT
SIGNATURE
A 0.62x4.10=2.54 Sq.mt.
11.50
SCHEDULE OF SANITARY:-
4.10

0.30 4.20 0.30 2.00 0.30 4.10 0.30


4 " DIA. C.I PIPE FOR SEWERAGE
B 1/2 " DIA. G.I PIPE FOR WATER SUPPLY
(15.00M)
45 CM. X 45 CM. SIZE MAIN HOLE
1.50

0.18

20 X 15 CM. C.CONC. DRAIN


0.11

B B 4.86
0.11+0.18/2x4.86=0.70 Sq.mt.
0.74
W4 W3 1.20 X 1.50X2.50 SIZE OF RAIN HARVESTING TANK
0.30

1.50
Toilet Kitchen
1.65 X 2.50X1.50 SIZE OF SEPTIC TANK
2.75

1.20x2.10 3.05x2.10 W1
Open Terrace 0.24x2.75/2=0.33 Sq.mt.
3.50

(11.00M)

4.10

5.00x4.25
C
(12.00M

D2 D2 Open Terrace

UP
5.00x4.25 0.24 ARCHITECT/ENGG.
D
0.62
D1 0.74
7.90

0.30

D1
)

1.11
A Drg.Cum Din A
D1 3.25x5.25
A A
Bed Room 1.11+0.74/2x4.10=3.79 Sq.mt.
3.50

4.10

D
4.10

W A W
3.65x3.75
CB 2.00
2.75

Bed Room
4.00x3.20
C
0.30

D1 D1
0.60

0.60

W1 W1 1.11
SIGNATURE
0.18
0.11

B 0.24

W 2.08
1.50

4.86 0.16x2.08/2=0.16 Sq.mt.


E
0.16

B
SANCTION AUTHORITIES
(14.00M) FIRST FLOOR TOTAL DEVIATION AREA:- 7.52 Sqm
0.30 3.00 0.30 4.40 0.30 2.90 0.30
B
11.50

SECOND FLOOR PLAN (SCALE 1:100) ROOF PLAN (SCALE 1:100)

GROUND FLOOR OF DEVIATION AREA:-


0.62
11.50 11.50

0.30 4.20 0.30 2.00 0.30 4.10 0.30 0.30 4.20 0.30 2.00 0.30 4.10 0.30

A 0.62x4.10=2.54 Sq.mt.
B B
4.10

R/Wall
Sewer Line
(15.00M) (15.00M)
1.50

1.50

R.H.T.
1.20X1.50X2.50 2.08 2.08
0.74 0.74
E W3 W4 W4 W3 E W3 W4 W4 W3
0.30

CAPACITY 4500LTS
0.16

0.16

0.18
0.11

Store Toilet
1.50 Store Toilet B 0.11+0.18/2x4.86=0.70 Sq.mt.
M WIDE

1.20x1.10 1.20x1.10 4.86


Kitchen 1.20x2.10 Kitchen 1.20x2.10
W3 3.15x1.95 D2 W3 3.15x1.95 D2
D2 D2
3.50

(11.00M)
4.10

4.10

Septic Tank Bed Room W Bed Room W


(12.00M

(12.00M

1.65X2.50X1.50M D2 3.15x3.65 D2 3.15x3.65


2.75

Capacity 6000lts
Toilet Toilet
0.24x2.75/2=0.33 Sq.mt.
PATH 3.00

W4 W4
3.15x1.50 UP D 3.15x1.50 UP D
0.62 D2
D1 0.62 D2
D1
C
7.90

0.30

D1 D1
)

0.24
D1 1.11 D1 1.11
A A A A 0.74
(11.00M)

D1 D1

Bed Room Bed Room


3.50
4.10

4.10

W A W W A W
3.70x3.75 Drg.Cum Din 3.65x3.75 Drg.Cum Din
CB 3.25x3.65 2.00 CB 3.25x3.65 2.00
2.75

2.75

Bed Room Bed Room


4.00x3.20 4.00x3.20 1.11+0.74/2x4.10=3.79 Sq.mt.
4.10

C C
D
0.30

1.50
D1 D1 D1 D1
0.60

W1 W1 W1 W1
0.18

0.18

Drain Line
0.11

0.11

B 0.24 B 0.24
W
W
1.50
1.50

4.86 4.86
Soak Pit 1.50m Dia B B 1.11
2.00m Depth
For Kitchen Waste
2.08
(14.00M) (14.00M) 0.16x2.08/2=0.16 Sq.mt.
E
0.16

0.30 3.00 0.30 4.40 0.30 2.90 0.30 0.30 3.00 0.30 4.40 0.30 2.90 0.30
11.50
11.50
GROUND FLOOR TOTAL DEVIATION AREA:- 7.52Sqm
FIRST FLOOR PLAN (SCALE 1:100)
GROUND FLOOR PLAN (SCALE 1:100)

Rajender Singh Chauhan


Town and Country Planner
Department of Town and Country Planning
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT Himachal Pradesh

Ref No. : 04201600035


21-Jun-2016