Professional Documents
Culture Documents
Gas Products 431
Gas Products 431
For questions specific to your file or products contact your CSA Group
technical staff associate. For technical questions on this Certification Notice
Go to http://www.csagroup.org/services/testing-and- Contact John Kory
certification/product-listing/ and enter your Master Contract # and by phone (216) 524-4990 x88125, fax 216-642-3081
the class numbers associated with this Notice to determine which or e-mail john.kory@csagroup.org
of your products are affected.
The standard edition or amendments announced in this Notice may be used for certification as of the date of issue of this Notice. The “Effective
date” in this Notice is the date on which the current requirements, applicable to Certified products listed in the affected class numbers, expire
and the standard edition or amendments announced in this Notice become the only requirements that may be used for certification.
In the event that currently certified products do not comply with the latest requirements outlined in this Notice after the “effective date”, the
certification of such models may be discontinued.
Visit us at www.csagroup.org where you can click on "Contact Us" for the online phone listing of our Offices and Partners.
DQD 529.01 Rev 2017-10-03 © CSA Group 2016. All rights reserved. Ref No: N18-037
Page 1 of 4
ATTACHMENT 1
Affected Class Numbers
Class No:
2751 82, REFRIGERATORS (GAS) - Compression Type-Certified to US Standards
2751 83, REFRIGERATORS (GAS) - Thermoelectric Type-Certified to US Standards
2781 84, CAMPING EQUIPMENT (GAS) - Portable Refrigerators-Certified to US Standards
ATTACHMENT 2
Major Revisions
Clause(s) Changes
Title Title of Standard changed to allow use of gases other than HD-5 propane
1.1 Scope of Standard has been expanded to include the use of butane gas or propane-butane gas
mixtures
1.2 The Standard now allows the use of a 1 pound cylinder with a CGA No. 600 connection as well as 20
pound propane cylinders and the disposable propane, butane, and propane-butane mixtures in UL
147B cylinders. The clause also now provides coverage to allow for regulated and non-regulated outlet
pressure.
4.3.1 Integral cylinder mounting and retention coverage is added for cylinders larger than 1 pound
incorporated in an appliance incorporating wheels.
4.3.2 Integral mounting and retention coverage added for an appliance that does not incorporate wheels
when a cylinder larger than 1 pound is incorporated in an appliance. Mounting and retention means is
not required if an appliance incorporates an integral propane cylinder less than 1 pound.
4.4.1-6 New section “Remote Propane Gas Supply Cylinder Systems” added to provide coverage for remote
cylinders.
4.5.1-18 New section “Propane Gas Cylinder Connection Devices” added to provide coverage for propane gas
cylinder connection devices.
4.6.1-5 New section “Enclosures for self-contained propane gas supply systems” added to provide coverage
for cylinder enclosures.
4.16.7 Added requirement for seat and external leakage for manually operated gas valves when used when
unregulated propane, unregulated butane, unregulated propane-butane mixtures or when regulated.
4.16.8 Added burst strength requirements for manually operated gas valve bodies.
4.16.9 Added cycling leakage requirements for manually operated gas valve bodies.
4.16.10 Added turning torque requirements for manually operated gas valve bodies.
4.16.11 Provided exception of manually operated valves complying with the Standard for Manually Operated
Gas Valves for Appliances, Appliance Connector Valves, and Hose End Valves, ANSI Z21.15 • CSA 9.1
do not need to comply with clauses 4.16.7 through 4.16.10
4.17.1 Allows for both regulated and unregulated outlet pressure.
4.17.2 Added requirements regarding how to attach the inlet of the pressure regulator to a CGA No. 791
Cylinder Connection Device, a CGA No. 810 Cylinder Connection Device, or a CGA No. 600 Cylinder
Connection Device. The clause also specifies appliances for use with butane and/or propane-butane
mixtures, the cylinder connection devices do not need to be a CGA No. 600 if the appliance is for use
with an UL 147B cylinder.
4.17.6 Gas pressure regulators operating at supply pressures of ½ psi or less must be Certified to ANSI Z21.18
/ CSA 6.3
4.17.7 The clause requires a portable refrigerator for use with regulated pressure to be supplied with a
regulator that is marked with the identifying marking of the regulator
4.17.8 The pressure regulator must be of the fixed (non-adjustable) type.
4.17.9 Gas pressure regulators for use with propane, butane or when used with propane/butane mixtures
shall be investigated for external leakage. Applicable to gas pressure regulators that are not Certified
to either ANSI Z21.18 / CSA 6.3 or UL 144.
4.17.10 Clause specifies burst strength for a body of a gas pressure regulator. Applicable to gas pressure
regulators that are not Certified to either ANSI Z21.18 / CSA 6.3 or UL 144.
4.17.11 A regulator shall have a predictable outlet pressure. Applicable to gas pressure regulators that are not
Certified to either ANSI Z21.18 / CSA 6.3 or UL 144.
4.24.1 The printed instructions accompanying the product must bear the symbol of the organization for
compliance with this Standard to provide verification for inspectors that the appliance and
instructions met the requirements of the Standard used during testing of the appliance.
4.24.1 A new boxed warning is added to the printed instructions accompanying the product.
4.24.1j Clause is added to require instructions for appliances which use with blended fuels.
4.24.1k Clause is added to alert the operator to keep ventilation openings unobstructed.
4.24.2a-m The printed instructions accompanying the product must now contain the additional information
contained in this section.
4.24.4aii A new statement is required in the printed instructions accompanying the product regarding the
replacement of any of the appliance wiring.
4.25.2d Appliances using butane or propane/butane mixtures must indicate the type of fuel used on the
appliance data plate.
4.25.2m Requires a marking to indicate that appliances using cylinders larger than 1 pound must be used
outdoors.
4.25.2n Requires a marking on the appliance to identify the appliance gas pressure regulator that was supplied
with the appliance.
4.25.6a A new marking requirement which shows the manufacturer’s recommended position of use of an lp
cylinder, including dimensions of the appliance, the appliance’s supply cylinder location and hose
routing, and a minimum warning label advising the end user of the potential hazard of placing the
cylinder too close to the appliance.
5.16.1-3 New section, “Appliance Structure” added to address the securement of the lP cylinder and the
stability of the appliance.
5.17 Added missing clause to exempt marking material complying with CSA C22.2 No. 105 or UL 969.