FOCUS-1 Introduction, Short

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

WELCOME TO THE WORLD OF

FOCUS-ON
15th Feb 2022

brief presentation of our philosophy CHANGING THE FLOW


FOREVER
just another
Industry 4.0 or boring IIoT
IIoT : we story?
focus on simplification
SCADA
HMI
Asset Performance
Supervision Level

3
( ) ( )
PLC / SPS
PIDs
Control Level

Setpoint (%) to
Control Valve
2
Flow measurement

Setpoint Output
Flow meter Flow Flow
Pressure Pressure ( P1 / P2 )
Control Valve
Temp… Temp ( T1 / T2 )
P & T Sensors Valve position
Production / Field Level and more….

1
FOCUS-ON I A SAMSON and KROHNE COMPANY 2
just another boring IIoT story?
Simplification
we focus on Industry 4.0
Our eyes are on : Real-time Asset Management
4
SCADA
HMI
Asset Performance
Supervision Level
3
( )
AIM TO
SIMPLIFY PLC / SPS
AUTOMATION
PYRAMID
PIDs
Control Level
2
( where possible )

Setpoint = Flow Output = Flow


Pressure Pressure ( P1 / P2 )
Temp… Temp ( T1 / T2 )
Valve position Flow meter
and more….
Control Valve
P & T Sensors
Production / Field Level
1
FOCUS-ON I A SAMSON and KROHNE COMPANY 3
FOCUS -1
Flow Optimized Control Using Sensors

Improved
Control
Quality
Advanced
computing power < ± 1% Liquid media
2% gas, 5% solid
(max)

PRESSURE AMBIENT TEMP

INTEGRATION of Field Device & Process insight max 40 bar -20 to 55 ˚C


( PN 16/40 – Class 150/300 ) ( PN 16/40 – Class 150/300 )

PROCESS TEMP VISCOSITY

-40 to 180 ˚C upto 100 cSt


FOUR (4)Control
key functional areas ( PN 16/40 – Class 150/300 ) ( Newtonian fluids )

Flow
& Pressure &
Temperature
1 2
control measure connect communicate
4 D – inlet run
&
3 4 &
0 D – outlet run

monitor alarm diagnose optimize

SIMPLIFY your PROCESS


( and it looks good ) Standard Valve Face-to-Face length
(except DN50 which is flowmeter dimension)

FOCUS-ON I A SAMSON and KROHNE COMPANY 4


1 FOCUS-1 thrives on modularity

Actuator with existing components Button for multiple functionalities


for air-to-open and air-to-close (connection to mobile devices,
initialization, security, etc.)

LED to communicate NAMUR


NE107 status
Cover for Ex-i compartment with
positioner and PT electronics
Electronics housing for all sensor and
computing hardware (Ex-d) and
Ex-e terminal compartment for Easy coupling for actuator air
connections

Wifi antenna (Zone 1) for


Clear visual indication for valve position
continuous communication

Body cover for sensor protection and


Innovative bonnet design with
design
sensor cable channels

Body with valve and integrated sensors


(P, T, Ultrasonic)

FOCUS-ON I A SAMSON and KROHNE COMPANY 5


2 Communication routes
Measure, Control, Alarms & Diagnostics

1. Analog Output
2. HART output 1
1. 4 – 20 mA 3. HART output 2
4. HART output 3

Profinet* Profinet*

% % - Flow (Q)
Control Setpoint Flow (Q) P1 - P2 - Δ P Feedback to DCS
P2* - ΔP* T1 - T2 ….

Ethernet
Wifi

Control * To be released soon Asset Management


2 3 3 4
6

FOCUS-ON I A SAMSON and KROHNE COMPANY 6


3 Digital shadow / twin – soft sensing
4 1.2 GHz 4-core processors
32 GB storage
T1 Control & Diagnostics

P2
Q
Qm T1m P2m
?/=
Q T1 P2

On-board Models:
- Reduce mechanical redundancies
- Real-time monitoring
- Process continuity

FOCUS-ON I A SAMSON and KROHNE COMPANY 7


Why FOCUS-1 ?

Traditional New control


Simplify

1 2 3 4
- Autotune Control
- Configure

Maintain

- Process continuity
- Less redundancies
- Advanced Alarms

Improve

1 2 3 4 8
- Real time information
- Build in models

FOCUS-ON I A SAMSON and KROHNE COMPANY 8


Benefits across entire lifecycle

Higher transparency on field


3 - customized alarms for device & process parameters
- digital models make mechanical redundancies obsolete Reliability
4 - real-time view of device & process
→ powerful information enables optimization
Productivity

AIM TO
Communication matters SIMPLIFY
2 - novel control philosophies reduce I/O & PLC/PID costs
AUTOMATION
PYRAMID
- a valve ‘finally’ controls flow
→ better control quality and loop efficiency ( where possible )

Integration of components CAPEX + OPEX


1 - allows reduced engineering and specification effort Costs
- less flanges, shorter piping
→ up to 33% savings vs. traditional solution
FOCUS-ON I A SAMSON and KROHNE COMPANY 9
FOCUS-1 family
A new family of product

▪ 24 V DC
▪ 4/20 mA IN setpoint
( passive – active )
▪ PROFINET

DN 80 / NPS 3” DN 100 / NPS 4” DN 50 / NPS 2” ATEX


version

available available Q1 / 2022 Q3 / 2022

FOCUS-ON I A SAMSON and KROHNE COMPANY 10


How can FOCUS-1 help to shine
light on your process loops?

Thank You.

CHANGING THE FLOW


FOREVER

11

You might also like