Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

S-19/21-22/SR/084 November 29, 2021

To
The Sr. DEE (RS)/LS/ED,
Loco Shed,
Chennimalai Road,
Southern Railway,
Erode - 638002.

Sub: Checking of DC DC Converters.


Ref: Your Letter no SA/A/RS/ED Tech-10C dated 22.11.2021.

Dear Sir,

With reference to your letter, please be intimated that we have already repaired all the mentioned
units but one and joint inspection had also been done. For unit Sl no 18086357 we have not received
any complaint and the unit is already out of warranty.

We have also attached the root cause analysis reports of the units which we have already received
and checked at our works. Be assured that we are continuously analysing and improving all issues
that we receive regarding the DC DC converters.

Also as requested by you, please find attached the schematic diagram for the DC DC converter for
your ready reference.

Thanking you and assuring our best of service always.

For SIGNOTRON (INDIA) PVT. LTD.

Soumik Ray
Manager - Service
9836444360

You might also like