Professional Documents
Culture Documents
Catalogo SevenGo
Catalogo SevenGo
Portable Instruments
Multi-Parameter Instrument
pH /ISFET
Conductivity
Dissolved Oxygen
Ion Concentration
Redox /mV
Relative Humidity
Temperature
Instruments in motion
– powered by Seven
SevenEasy™ pH
ATC
The Automatic Temperature Com-
pensation (ATC) feature allows the
electrode signal to be corrected for
the effect of temperature.
Automatic endpoint
This improves the reproducibility
of your measurement data and safe-
guards the quality of your results.
Automatic buffer recognition
With this function you can choose
the order in which you use your
pH buffers for regular calibration.
This speeds up calibration pro-
cedures and eliminates unneces-
sary error messages. Choose a 1-,
2- or 3-point calibration.
2
Seven Service – Electrochemical instruments at your service
Regular equipment qualification increases the uptime and accuracy of your instrument over many
years. It is just one of a number of services that METTLER TOLEDO offer, tailor-made to suit your
needs for all Seven instrument lines. A large number of different service solutions are available for
the Seven bench-top range, from basic repairs through to comprehensive service options and equip-
ment qualification. All meters are delivered with a signed manufacturer‘s certificate. Seven Service
– better assurance of your result.
A comprehensive range of
pH electrodes is given in the
separate brochure entitled „Elec-
trodes in Motion – powered by
Seven“ (Order No. 51724332).
Electrode condition
You see right away whether your
electrode is in good condition.
Does it have to be cleaned or SevenEasy™ S20 Measuring range Resolution Accuracy
replaced? A pictogram immedi- pH 0.00 … 14.00 0.01 ±0.01
ately puts you in the picture.
mV -1999 … 1999 1 ±1
Temperature -5.0 … 105 °C 0.1 °C ±0.5 °C
Sensor inputs BNC, Cinch/RCA (NTC 30 kΩ)
Interfaces RS232 (connection to printer or PC)
Power requirements Power adapter (9 V, DC) or four AA batteries (not incl.)
Size / Weight 180 x 180 x 65 mm / 610 g
Package / Weight 370 x 320 x 165 mm / 3.1 kg
Mobility
Both SevenEasy™, pH and Conduc-
tivity can be connected to the line
voltage or operated from batteries.
Make SevenEasy™ independent
of line power by inserting four AA
batteries!
Temperature compensation
You can use three types of temper-
ature compensation: linear, non-
linear (DIN 38404) and no com-
pensation for purified water (USP).
The SevenEasy™ S30 is ready for Self-diagnosis
all types of samples. The S30 also has a self-diagnostic
test program, just like the SevenEasy™
S20. The user can check the hard
and software using an interactive
dialog with the instrument. This is
your personal guarantee that every-
thing is working properly.
4
The right electrode for every application
The S30-K is equipped with the robust multipur-
pose InLab®730 conductivity cell as standard.
This cell covers a multitude of applications involv-
ing aqueous samples above 10 µS/cm. Samples
that contain solvents should be measured with
cells made of platinum and glass such as the
InLab®710 or InLab®720. The high performance
InLab®740 electrode can measure samples down
to 0.01 µS/cm.
The detailed specifications for each electrode
are given in the separate brochure entitled „Elec-
trodes in Motion – powered by Seven“ (Order No.
51724332).
Peripheral connections
The S20 and S30 instruments
are equipped with an RS232
4 measurement modes interface as standard. You can
The SevenEasy™ S30 offers you connect a printer or a computer
all the different measurement to SevenEasy™: very convenient
modes and units: conductivity, GLP support.
TDS, resistivity and salinity.
This eliminates the need for any
manual calculations.
Automatic recognition
SevenMulti™ automatically recog-
nizes a new module that has been
installed. This makes changing
from one parameter to another fast
and easy.
Professional calibration
Electrodes and accessories The 9 calibration points (maxi-
The Seven electrode stand mum) with the choice of linear
provides even more conven- or segmented algorithms as well
ience and efficiency. Further as user-definable buffers give the
practical Seven accessories expert unlimited flexibility.
and a selection of different
electrodes are given at the
end of this brochure.
6
Communication modules
The TTL and USB com-
munication modules
open up new worlds.
Text menus
The backlit display and the text menus
guide you safely through installation,
calibration and measurement, and the
control of peripherals.
GLP support
SevenMulti™ helps you with instru-
ment, sensor, user and sample
identification – there is even a bar
code reader.
Measurement curve
The SevenMulti™ has a dot-matrix
display. If desired, you can display
your results graphically.
Calibration curve
You can instantly display your
calibration curve and check the
linearity visually.
7
SevenMulti™
8
SevenMulti™ S47 SevenMulti™ S47 Measuring range Resolution Accuracy
pH -2.000 ... 19.999 0.001, 0.01, 0.1 ±0.002
Two-channel pH and conductivity measurement
mV (rel. mV) -1999 ... 1999 0.1 ±0.1
• Combines all functions of the S40 and S70
Temperature -30.0 ... 130 °C 0.1 °C ±0.1 °C
• Clear, two-channel measurement thanks to large
display Conductivity 0.01 µS/cm ... 0.01 ... ±0.5 %
1000 mS/cm 1
• Context-sensitive Help menu
Temperature -5.0 ... 130 °C 0.1 °C ±0.1 °C
• USP-mode: satisfies current requirements for puri-
fied water TDS 0.01 mg/L ... 1000 g/L 0.01 ... 1 ±0.5 %
• Supports user-defined calibration standards Resistivity 0.00 ... 20.00 MΩcm
• Alphanumerical keypad Salinity 0.00 ... 80.00 ppt
• Comprehensive range of electrodes and accessories Sensor inputs BNC, 2 mm Ref., Cinch/RCA (NTC),
4 mm banana (PT1000), mini-DIN
Interfaces RS232 (connection to a printer or PC), titrator output
Power requirements Power module (9 V, DC)
Size / Weight 190 x 240 x 65 mm / 1120 g
Package / Weight 370 x 320 x 165 mm / 4.2 kg
9
SevenGo™
3 4
At a glance
SevenGo™s large display shows
all the relevant settings and high-
lights the most important items.
You can read the measured value
and check the condition of the
electrode at a glance.
Infrared communication
The IR interface sends data to your note-
book without a cable connection, or to
a printer or PC by means of an IR adapt-
er. The IR window of SevenGo pro™ is
hermetically sealed in the housing and
provides the greatest possible protection
against water and dust.
Illumination
The bright backlit display can be
switched on as desired and facilitates
your work under poor-light condi-
tions. The interval for switching it off
can be individually programmed,
thus prolonging the lifetime of your
batteries. Maximize operating con- Barometric pressure
venience. The SevenGo pro™ SG6 model for
dissolved oxygen measures the
air pressure using an integrated
barometer. Fluctuations in air
pressure are automatically com-
pensated and the reproducibility of
the oxygen measurement is corre-
spondingly increased.
12
Routine mode
In this mode you can work
Expert mode
really quickly with the
The expert configures SevenGo pro™
SevenGo pro™ because
undisturbed in the laboratory. The
the settings relevant for
whole range of functions is available.
the measurement are fixed
ready to select.
• Data memory for 200 GLP data points Outputs IR to printer or PC via RS232 or USB
• Backlit display (applies to all SevenGo pro™ models) Power requirements 4 AA batteries 1.5 V or NiMH accumulators 1.3 V
Operating environment 0 ... 40 °C, 5 ... 85% rel. humidity (non-cond.)
Size / Weight 220 x 90 x 45 mm / 325 g (without batteries)
SevenGo pro™ conductivity – SG7 SevenGo pro™ SG7 Measuring range Resolution Accuracy
Conductivity 0.01 µS/cm ... 0.01 ±0.5 %
Professional conductivity meter (IP67) 1000 mS/cm
• Calibration also with user-definable standard or cell Temperature (°C / °F) -5.0 ... 105 °C 0.1 °C ±0.1 °C
constant TDS 0.01 mg/L ... 600 g/L 0.01 ... 1 ±0.5 %
• Linear and non-linear temperature compensation Resistivity 0.00 ... 100.00 MΩcm
• Measurement of purified water according to USP Salinity 0.00 ... 80.00 ppt
• Data memory for 200 GLP data points Sensor inputs LTW 7 pin (IP67)
• Comprehensive GLP functions with sensor and sample Outputs IR to printer or PC via RS232 or USB
identification Power requirements 4 AA batteries 1.5 V or NiMH accumulators 1.3 V
Operating environment 0 ... 40 °C, 5 ... 85% rel. humidity (non-cond.)
Size / Weight 220 x 90 x 45 mm / 325 g (without batteries)
SevenGo pro™ pH/Ion – SG8 SevenGo pro™ SG8 Measuring range Resolution Accuracy
pH -2.000 ... 19.999 0.001 ±0.002
pH/Ion meter (IP67) for highest demands mV (rel. mV) -1999 ... 1999 0.1 ±0.1
• Simple ion concentration determination Temperature (°C / °F) -5.0 ... 130.0 ATC 0.1 °C ±0.2 °C
• Time interval measurement with automatic data logging -30.0 ... 130.0 MTC
• Data memory for 200 GLP data points Sensor inputs BNC (>1012 Ohm); NTC 30 KΩ (both IP67)
• Segmented or linear calibration as desired Outputs IR to printer or PC via RS232 or USB
• 5-point calibration with choice of 6 predefined and one Power requirements 4 AA batteries 1.5 V or NiMH accumulators 1.3 V
user-defined buffer set Operating environment 0 ... 40 °C, 5 ... 85% rel. humidity (non-cond.)
Size / Weight 220 x 90 x 45 mm / 325 g (without batteries)
Sensor recognition
Changing parameters is child‘s
play thanks to the practical
connection system and the in-
tegrated automatic sensor rec-
ognition. Large memory
For each individual parameter
you can save, recall or print up
to 199 measured data points
together with date, time and
Always with you identification number for every
Trio-Mate is the best solution if individual parameter.
you want to measure the three
most common parameters, pH,
conductivity, and dissolved
oxygen. All the accessories and
sensor modules are supplied in
a compact case.
Three kit-models
X-matePro is available in three kits: Mono-Mate is for simple pH measurement, and Trio-Mate for pH,
conductivity and dissolved oxygen. With Poly-Mate you decide which sensor modules you want to
have in your case.
16
MX300 (instrument) Specifications
Input resistance >1012 Ohm
Input/output RS232 (15- pole socket , female)
Material module ABS
Material sensor shaft Polysulfone for pH sensor modules, Epoxy for all the others
Display with selectable LCD dot matrix with 0.1/0.01/0.001 digits resolution
Power requirements 2 batteries type A4 or rechargeable NiMH
Battery life 200 hours, with low - battery icon
Areas of operation - 5 ... 40 ºC, 90 % RH bei 35 ºC, non - condensing
Regulatory compliance CE, (EN50081-1 & EN50082-1), FCC part 15 class A
Size of instrument 55 x 41 x 145 mm
Size of sensor module Module 183 x 55 x 40 mm, Shaft 135 x 12 mm
Weight 176 g (meter only), 273 g (with typical sensor module
InLab®482)
Seven/Rondolino stirrer driver 51302827 Check plug for MX300 instrument 51303001
Disposable cups for Rondolino, 1400 pcs 00101974 RS232/interface module (for printer and PC) 51303002
www.mt.com
METTLER TOLEDO
gone global...
the contact addresses of METTLER TOLEDO
representatives globally can be found under
the Internet address www.mt.com/contacts
otherwise:
Mettler-Toledo GmbH
PO Box VI-400, CH-8606 Greifensee
Tel. +41-44-944 22 11
Fax +41-44-944 31 70
Pubished by:
Mettler-Toledo GmbH, Analytical,
CH-8603 Schwerzenbach, Switzerland
Telefon +41-44-806 77 11, Fax +41-44-806 73 50, Internet: www.mt.com