Professional Documents
Culture Documents
WL-275 FTC 200kW
WL-275 FTC 200kW
WL-275
Cummins
KTA19
FARADAY-120
FD4L
DeepSea
DSE7310
PRP CONTINUS
kVA 275 250
Power Rating
kW 220 200
Frequency Hz 50
Speed RPM 1500
Voltage V 400/230
P.F. Cos Phi 0.8
General Data
Engine Model KTA19
Number of Cylinders 6
Cycle 4-stroke
Aspiration Turbocharged and Charge Wator Cooled
Bore x Stroke mm 159 x 159
Displacement L 18.9
Primer Power Output kW 274
Continus Power Output kW 250
Compression Ratio 10.5:1
Speed RPM 1500
Engine Configuration high-energy ignition integrated module
GAS Consumption ( 100% ) Nm3/kwh 0.9
GAS Consumption ( 75% ) Nm3/kwh 1
GAS Consumption ( 50% ) Nm3/kwh 1.2
Lubrication Capacity L 27
Coolant Capacity L 40
Intake Air Flow L/S 112
Exhaust Gas Temp. ℃ 600±20
Exhaust Gas Flow kg/min 25
Engine Features
24 volt negative earth
Starting System Battery charging alternator 35 amp on engine
Cranking current 1800 amps at 0°C
1)Gas temperature ≤ 40℃
2)Pressure 15-50kpa
3)H2S ≤ 200mg/Nm3
Bio gas requirment for gas 4)NH3 ≤ 20mg/Nm3
5)CH4 content ≥ 40%, changing rage ≤ 2%/min
6)Impurity particle size ≤ 5μm, impurity content ≤ 30mg/Nm3
7)Moisture content ≤ 40g/Nm3
Air cleaner with dry element
Spin-on full flow lube oil filter
Filters
Standard air filter
Standard oil filter
Water-cooled
Cooling
40°C ambient temperature radiator
Reference Standards:
BS-5514 and DIN-6271 standards are based on ISO-3046.
Operation At Elevated Temperatrue And Altitude:
Up to 5,000 ft.(1500m) and 104°F (40℃) without power deration.
General Data
Alternator Manufacture FARADAY
Alternator Model FD4L
Continus Power kVA 380
kW 304
Effciency % 93.8
Class-Temp Rise H-125/40°C
Alternator Voltage Regulation MX321
Voltage regulation ±1 %
Winding Leads Wires 12
Pitch 2/3
Alternator Insulation Class H
Protection Class IP23
THD in no-load < 3.5 %
THD in linear load <5 %
Alternator Specification
- Excitation Systems: short circuit capacity
- SHUNT system: without short-circuit capacity.
- AREP, PMG: 3 times the nominal current for 10 seconds.
- Transient features :
-Transient voltage dip for rated step load at 0.8 power factor is less than 18 %.
-Recovery time for a 20 % transient voltage dip is less than 0.5 s.
- Overload acceptance :
-Pole alternators can be overloaded according to NEMA
- Forms :
-4 Pole alternators can be provided in single or two bearing configurations.
- Overspeed :
-The maximum overspeed is 2250 min-1
- Balancing :
-All the rotors are dynamically balanced according to ISO 1940 & NFC 51-111
-Single bearing rotors are balanced with a half key
Key Features
Δ 4-Line back-lit LCD text display
Δ Five key menu navigation
Δ Front panel editing with PIN protection
Δ LED and LCD alarm indication
Δ Customisable status screens
Δ Power save mode,Flexible sender inputs
Δ Support for up to three remote display units
Δ 9 configurable inputs,8 configurable outputs
Δ Configurable timers and alarms
Δ 3 configurable maintenance alarms
Δ Multiple date and time scheduler
Δ Configurable event log (250),Control logic facilities
Δ Easy access diagnostic page
Δ CAN and Magnetic Pick-up/Alt.sensing
Δ Fuel usage monitor and low fuel alarms
Δ Charge alternator failure alarm
Δ Manual speed control (on compatible CAN engines)
Δ Manual fuel pump control,Engine exerciser
Δ “Protections disabled” feature
Δ kW overload protection
Δ Power monitoring (kW h, kV Ar,kV A h, kV Ar h)
Δ Load switching (load shedding and dummy load outputs)
Δ Automatic load transfer (DSE7320)
Δ Unbalanced load protection
Δ Independent Earth Fault trip
Δ USB connectivity
Δ Backed up real time clock
Δ Fully configurable via DSE Configuration Suite PC software
Δ Configurable display languages
Δ Remote SCADA monitoring via DSE Configuration Suite PC software
Δ User selectable RS232 and RS485 communications
Δ SMS Messaging (additional external modem required)
Δ Additional display screens to help with modem diagnostics
Δ DSENet® expansion compatible
Δ Integral PLC editor
Genset information
H H
W W
L L
Dimension and Weight Open Silent
Length mm 4200
Width mm 1650
Height mm 2050
Shiping Weight kg 3550
Canopy Features
Robust Corrosion Resistant Construction
Δ Black finish stainless stell lock and hinges
Δ body made from steel components treated with polyester powder coating
Excellent Access for Maintenance
Δ radiator fill access plate
Δ lube oil and cooling water drains pipes to exterior of the enclosure
Δ adding cooling water from top of canopy
Δ LED light will be lighting automaticlly when open the door
Security and Safety
Δ control panel viewing window in a lockable access door
Δ emergency stop push buttom (red)mounted on enclosure interior
Δ cooling fan and battery charging alternator fully guarded
Δ exhaust silencing system totally enclosed for operator safely
Δ Control panel and cable design in different directions,all the connection wiring in
control panel are more neater and firmer.
Firsttechnology&Control Co.,Ltd.