Appendix 7.

Details of Protection Height above Bed


LHS Coordinates RHS Coordinates Span Condition of Various Features of Culvert Parapet/Headwall
Invert works Level
Type of Arrangementan Width Depth b/w
EXISTING Total level Adequacy Tentative
Sl. Structure Culvert Thickness d Total Carriageway of top of culvert Presence
CHAINAGE Length from top of Remarks Improvemen
No. No. (Pipe, Slab, of Slab (m) Ventway Width (m) Culvert & road of Sour
(Km) (m) of Road Slab/Pipe/ Head Wing Return Parapet/ Headwall/Para U/S D/S Waterway t Proposal
Box, Arch) X Y X Y (No.x Length) (m) surface (mm) Type Condition Height
(m) Box/Arch Wall Wall Wall Handrail pet Length side(m) side(m)
(m)

L=4.4, Head
1 52+825 - HP 747434 3175240 747401 3175264 0.120 62.0 1x1.2 15+15 - L=3.1, R=3.0 Good Pipe Good - - - 1.4 L=5.0, R=7.5 - - No Yes Skew -
R=4.3 Wall

L=6.0, Head
2 54+960 - HP 747407 3173135 747379 3173127 0.120 69.0 1x1.2 15+15 - L=4.5, R=3.4 Good Pipe Good - - - 1.3 L=7.25 ,R=8.2 - - No Yes Skew -
R=4.7 Wall

L=4.2, Head
3 65+755 - HP 750948 3163015 750921 3162998 0.120 54.0 1x1.2 15+15 - L=1.8, R=2.0 Good Pipe Good - - - 2.4 L=7.0 ,R=6.0 - - No Yes New Culvert -
R=4.4 Wall

L=3.1, Head
4 66+515 - HP 751389 3162404 751372 3162372 0.120 51.0 1x1.2 15+15 - L=1.7, R=1.6 Good Pipe Good - - - 1.4 L=5.5 ,R=8.0 - - No Yes Skew -
R=3.0 Wall

L=7.4, Head Headwall Not


5 66+755 - HP 751542 3162233 751530 3162195 0.120 50.5 1x1.2 15+15 - L=6.0, R=5.8 Good Pipe Good - - - 1.5 L=0.0 ,R=7.3 - - No Yes -
R=7.1 Wall Provided

L=4.4, Head
6 70+395 - HP 754260 3159815 754232 3159809 0.120 58.0 1x1.2 15+15 - L=3.2, R=2.8 Good Pipe Good - - - 1.5 L=7.0 ,R=7.0 - - No Yes New Culvert -
R=4.2 Wall