Professional Documents
Culture Documents
Study On Leak Location Technology For Buried Gas Pipeline
Study On Leak Location Technology For Buried Gas Pipeline
3. The leak location algorithm for buried gas pipeline for that another sensor can receive leak point signal in the
same time. In fact, the sampling length is 2t at least, and
As influenced by external environment, leak signal fixed sampling frequency is selected.
may be submerged in the noise. It is very difficult to realize The front part A1 of signal A(n) received by
accurate location if we only use correlation analysis method. sensor A (it contains one leak signal length at least) is
Hence, the AE signal that is acquiring should be made
wavelet denoising and wavelet reconstruction, and then selected. The front part B1 of signal B (n) received by
leak identification can be made. If there is leak, the sensor B(same length as A1 ) is correlated with A1 by use
processed signal will be calculated in correlation location
algorithm model and the delta-T will be extracted. With the of correlation formula. The result r1 can be gained. Then,
delta-T, location calculation can be done according to the moving backward the signal received by sensor B dot by
linear location algorithm. dot, the equal length signal is correlated with A1
continuously, r1 , r2 , … can be obtained.
3.1. The formula of location upon delta-T
N −1
rAB (m) = ∑ A(n)B(n + m) (2)
As shown in Fig.2, A, B are two AE sensors. The leak n =0
point is between two sensors. N dot number of signal A1 or B1
Leak point m from 0 to N-1
Moving backward A(n) dot by dot, the signal of
v
same length is correlated with B, r−1 , r− 2 , … can be
gained. As the leak signal is random, only the correlation
A B result of the leak signal received in the same time has the
biggest correlation degree. So formula (2) is self-relation
X of leak signal received in the same time. When correlation
D result is biggest, the correlation formula is as follow:
N −1
rL (i ) = ∑ A(n)B(n + i ) (3)
n =0
Figure 2. Schematic diagram of pipeline
Two signals from two sensors are made to do This can be obtained by the nature of self-relation
correlation calculation, delta-T that AE signal transmit to function. Comparing the correlation result above, the
position A and position B can be obtained. The formula (1) maximum can be found. After leak signal arriving sensor A
is as follow. (or sensor B), it delay a period of time to arrive sensor B (or
D − (v × ∆t ) sensor A). Then, the delta-T that signal arrive two sensors
x= (1) will be obtained. As the sampling frequency is known, the
2 formula can be gained as follow.
y x the distance from leak point to sensor A M
y D the distance between two sensors ∆t = max (4)
y v sonic wave transmitting speed
f
According to formula (1), the leak point can be
y ∆t delta-T that leak signal transmit to two sensors
located.
3.2. The leak location algorithm
4. The leak location experiment for buried gas
pipeline
The sonic speed v that leak AE signal transmits in the
buried gas pipeline should be tested. The data can be
4.1 Buried gas pipeline in experimental site
obtained by engineering manual. It also can be obtained
through field testing if possible.
The buried steel pipeline is 60 meters long, and buried
As the leak point is unknown, it is important to select
depth is 50cm. The actual leak is imitated by ball valve that
suitable sampling length in order to ensure that two sensors
is located in 23 meters from pipe left. The sensors
can receive the signal transmitting in one time. Hence,
placement is indicated in Fig.3. The pressure inside pipe is
considering the extreme situation, leak point lay in one
0.5 MPa. The sampling rate of the acquirement instrument
sensor, the shortest sampling length must be t = D / v ,
493
Proceedings of the 2009 International Conference on Wavelet Analysis and Pattern Recognition
is 500kS/s.The schematic diagram of experimental pipe is scale. The spectrum diagram is spectrum information
shown in Fig.3. relative to each decomposition scale. The detailed
description is made in the title of diagram. (only scale 5,6 ,7
Sensor A AE source (leak) Sensor B is shown in Fig.5).
1# 2#
23m 37m
60m
494
Proceedings of the 2009 International Conference on Wavelet Analysis and Pattern Recognition
5 Conclusions
References
Figure 6. Correlation location diagram of scale 5
reconstruction signal
[1] Roberts Ron A., Rewerts Lance E, Clark M. Amanda.
The role of propagation characteristics in acoustic
From Fig.6, it can be seen that the position of pipe leak emission pipeline leak location. Review of Progress in
point is x = [60 − 1885 × 3000 / 500000] / 2 = 24.35m . Quantitative Nondestructive Evaluation. 1998,
The actual position is 23m from the pipe left. The location Vol.17(5): 501-508.
error is [(24.35 − 23) / 60 × 100%]=2.25%. [2] Xia Haibo, Zhang Laibin. The pipeline leak location
method based on GPS time label. Computer testing
and controlling, 2003, Vol.11(3): 161-163
[3] Shen Gongtian, Geng Rongsheng, etc. the source
location technology of continuous AE signal.
Nondestructive Testing.2002 , Vol. 24(4): 164-16.
[4] Lee Joon Hyun. Acoustic emission technique for
pipeline leak detection. Key Engineer Materials.
2000,186(4):888~892.
[5] Miller R.K, Pollock A.A, Finkel P., et al. The
development of acoustic emission for leak detection
and location in liquid filled, buried pipelines. Journal
of Acoustic Emission. 2001,32 (2):245-256.
Figure7.Correlation location diagram of scale 6 reconstruction [6] Gu Xiaohong, Hou Dibo, ect. Measurement of leak
signal
location in buried iron water pipe with acoustic
From Fig.7, it can be seen that the position of pipe leak
emission and EMD. Journal of Zhejiang
point is x = [60 − 1905 × 3000 / 500000 ] / 2 = 24 .29 m .
University(Engineering Science). 2006, Vol. 40(7):
The actual position is 23m from the pipe left. The location 1105-1108.
error is [(24.29 − 23) / 60 × 100%]=2.15% . [7] Guo Chunhua, Shao Ming, ect. Leak Location of
Water Pipeline Based on Wavelet Analysis. Pipeline
From the correlation diagram of Fig.6 and Fig.7, it can Technique and Equipment. 2006,4: 19-20.
be seen that scale 5,6 can all recognize the position of leak
source. The signal reconstructed by scale 5,6 can reflect the
essential character of leak AE signal in buried gas pipeline.
495