Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Electrical layout , Total Area ( 686.

25 m2 )

SCALE 1:1

UP UP
Heater Heater Heater Heater Heater
W W W W W W W
1 1 1 1 1 1 1

AC L Coriidor EL
1 4 3 2

D T
1 1

REF. BATH BATH BATH BATH BATH BATH BATH REF. D


KITCHEN
COOKING COUNTER

REF.

COOKING COUNTER
L
1
1
F
AC
1

T D T D T D
1 1 1 1 1 1

D D D D D D
D
D T D T
1 1 1 1

5 5 5 5 5 5
5

D W
6 1
MAIN KITCHEN

CABINET
Heater MALE TOILET T
1
D
1

MACE OFFICE
CONTRACTOR DINING

AC

1
F
H
1

1
TOILET

2.0 M WIDE COVERED

2.0 M WIDE COVERED


L
2
MALE TOILET FEMALE TOILET
L
1

OFFICE
F
1

D
H
1

D D
5
D
5 DAR & MACE D
5
D
5 DAR & MACE 4

WALKWAY

WALKWAY
5
D
6

D D
AC
1

L
2

4 3
Ground Floor plan,
Total Area ( 686.25 m2 )

D T
1
D
1
T
1
D
1
SCALE 1:1

BATH BATH BATH


B C
4 D
1
T
1
D
1
T
1

BATH
A300 A200

TOI.

CABINET

CABINET

CABINET
UP UP
W W W W W W W
1 1 1 1 1 1 1

A REF. REF. D

COOKING COUNTER
2

MEETING ROOM
KITCHEN

STORE CABINETS
BATH BATH BATH BATH BATH BATH BATH REF.

COOKING COUNTER
3750
D D D D
D D D 5
5 5 5 5 5 5

D W
6 1
MAIN KITCHEN

CABINET
MALE TOILET MALE TOILET FEMALE TOILET MACE OFFICE
L
2

STORE PPE
CONTRACTOR DAR & MACE DAR & MACE

2.0 M WIDE COVERED

2.0 M WIDE COVERED


OFFICE DINING
D
TOILET D D
5
D
5
D
5
D
5 4

WALKWAY

WALKWAY
5
D
6

B BATH BATH BATH BATH TOI. D


4
D
3
AC

D
1

PRAYER 4
ROOM

CABINET

CABINET

CABINET
STORE CABINETS
3750
WASH BASIN
STORE PPE
WASH BASIN
MEETING ROOM

Panel board #3

STORE CABINETS
TV

WASH BASIN

WASH BASIN
1
STORE CABINETS
D D D
2 2 2 D
D D 2
1

T
1
CABINET CABINET CABINET 2 CABINET

1
T
D
PRINTERS PLOTTER CABINET CABINET 3

D
1
PRAYER

D
1
BATH

3000
1
D
W
1
D
6

PROJECT

WASH BASIN

WASH BASIN
D MANAGER DAR W
1

OFFICE

3000
W D

ROOM
B
1 CABINET
4
D
A200 D
1 A200

E W
1

W
1

3000
L
L L 3
D

31500
H H El 6 3 H EL F 1
F H EL F 1 1 3 L
1 1 1 6 1 3 CABINET
L 1 L 3 CONSULTANT
6 3
A D
4
D
4 OFFICE
W
1 A
A300 F PROJECT
A300
MANAGER ASST. PM

L
4

AC

3000
W W

1
1 1

CABINET

CABINET
W
1

D D

CABINET
BATH

3000
D W
6 1

COOKING COUNTER
REF.
VISITOR
W
OFFICE 1

2
W
KITCHEN

2
1

2 D H D
7

D W
4 1

3000
4

W
1

D 2 I
MEETING
ROOM W
1

1
1

3000
CABINET
W

CABINET CABINET CABINET


1 D
1
D
1
CABINET
Corridor D D
3 CABINET 3 6
AC D D
CABINET
1 4 4

AC AC EL
L
4 AC EL
L
4
J GENERAL
D.C KITCHEN
1 1 1 L 1 1 L
MANAGER W
PROJECT 1
3 4
DIRECTOR W W

3000
W 1 1
1

CABINET
REF. COOKING COUNTER

K
T
1
D
1
D D
1
T
1

PRINTERS PLOTTER CABINET CABINET 3


B
A300 A
A200

BATH 3750 3750 2500 2000 3000 3000 3000


43500
3000 2530 2480 2470 2530 2000 3750 3750

1 2 3 4 6 10 11 11 12 13 14 1

Heater

W 1- ALL DIMENSIONS ARE IN MILLIMETER UNLESS OTHERWISE


1
NOTED.
1
T

1
T

D
T
1

1
D

1
D

6
1
D

T
1
D
1
H
1
F
1
L
1
BUILDING AREA : 686.25 m²

PROJECT
1
T
D
1

W
MANAGER DAR 1

Electrical Layout
( AC Split & Fan & Light & Power Socket & Floor Box &
OFFICE Data & Telephone & Fire alarm system )

SYMBOLS DESCRIPTIONS
W D
1 CABINET
4 RAC Split
1
T

1
T
1
T

AC L
1 3
1
D

1
D
D
1

CU ( condenser unit )
D
1
1
T
D
1

WALL MOUNTED EXHAUST FAN


L L L EL
3 3 3 1

W
1 EXHAUST FAN - DUCTED

W LED 60 * 60 CM , 40 Watt
EL
1

1
T

1
T
L
3

T
1

D
1

1
L
3
L
3

1
D

1
D
Exterior lighting
AC
1
AC
1

One way one gang switch

D CONSULTANT
1
OFFICE One way two gang switch
D
1
T
1
CABINET

D
L AC L AC

D
2 1 2 1

W
4 4 1 L L / It means lighting

No. No. / It means The number of lights

T
1

1
AC / It means AC Split
AC

1
T

1
T

D
1

1
D

D
1

1
NO.
PROJECT
MANAGER ASST. PM F F / It means Fan

No. No. / It means The number of Fan


External light
W W
1 1
H H / It means Heater
CABINET

CABINET

No. No. / It means The number of Heater

W
1 EL EL / It means External light

No.

1
T

1
T
D

T
1

1
D / It means Data

1
D

1
D
D

D
1

1
D
1
T
1
D
1
T
1 No. No. / It means The number of Data

BATH D
1
T
1
T T / It means Telephone

No. No. / It means The number of Telephone


L
1
1
F

CABINET
H
1

Monitor

D W
6 1
Duplex Socket

Heater

1
T

1
T
1
T

1
T
COOKING COUNTER

D
1

1
KITCHEN

1
D

1
D
REF.
VISITOR Single Socket
L
1
F

W
1

OFFICE 1
AC
1

W
1
D
7 S Smoke Detector Battery

Notes
1- The height of the Power Socket & Data & Telephone,
TV D
D W starting from the floor, is 30 cm.
1 2-The height of the lighting switches, the air conditioner, and the
1 1

AC

L
2
1
4 heater, starting from the floor, is 120 cm.
D
4

1
T

1
T
1
T

1
T

1
D

1
D
D

D
1

1
W
1
AC
31
L

MEETING
Company Name Al-Ayed Contracting Company
T D
1 1

W
ROOM 1

W Project Title Fabrication porta cabin (Complex)


1

TYPE Electrical Layout

1
T

1
T
1
T

1
T

D
1

1
AC AC AC AC

1
D

1
D
1 1 1 1
EL
1
L
4

T D
1 1
AC
1

DESCRIPTION xxxx
AC
1

W Panel board # 2
1 D
Panel board #1 1
D
1 L
3
L
3
L
3
EL
1
CABINET Approved By CEO - Mr.Rami
AC

L
2
1

D D
AC
1
L
2

CABINET 3 6
Designed By Eng-Hazem Abdullah
D
AC L L AC
1 2 2 1

CABINET D
4 4
Model file Ref xxxx
L
4

GENERAL D.C
MANAGER W KITCHEN Drawing ( latest xxxx
PROJECT 1
revision )

W
DIRECTOR W
1
W
1
1 Scale xxxx

Drawing No. 000000000000


CABINET
D
1
T
1

Heater
Sales officer Mr. Abdullhay Alfarargy
REF. COOKING COUNTER
D
1
T
1
D
1
T
1
Mobile 0550571128

E-mail alfarargy@inmafactory.com.sa

You might also like