NIKKON S419-400 S0400. / Luminaire Data Sheet

Luminous emittance 1:

Luminaire classification according to CIE: 99 Due to missing symmetry properties, no UGR table
CIE flux code: 45 82 98 99 74 can be displayed for this luminaire.
NIKKON S419-400 S0400 Street Lantern c/w HPS 400W Tube Lamp

Page 1
Arar
11.04.2022

Operator
Telephone
Fax
e-Mail

Street 1 / Planning data

Street Profile

Roadway 2 (Width: 13.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070)


Median 1 (Width: 2.000 m, Height: 0.000 m)
Roadway 1 (Width: 13.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070)

Light loss factor: 0.67


Luminaire Arrangements

Luminaire: NIKKON S419-400 S0400.


Luminous flux (Luminaire): 37207 lm Maximum luminous intensities
Luminous flux (Lamps): 50000 lm at 70°: 297 cd/klm
Luminaire Wattage: 412.6 W at 80°: 158 cd/klm
Arrangement: on Median at 90°: 45 cd/klm
Pole Distance: 34.000 m Any direction forming the specified angle from the downward vertical, with the luminaire
Mounting Height (1): 11.965 m installed for use.
Height: 11.978 m Arrangement complies with luminous intensity class G1.
Overhang (2): 0.035 m Arrangement complies with glare index class D.0.
Boom Angle (3): 15.0 °
Boom Length (4): 0.987 m

Page 2
Arar
11.04.2022

Operator
Telephone
Fax
e-Mail

Street 1 / Luminaire parts list

NIKKON S419-400 S0400.


Article No.: S419-400
Luminous flux (Luminaire): 37207 lm
Luminous flux (Lamps): 50000 lm
Luminaire Wattage: 412.6 W
Luminaire classification according to CIE: 99
CIE flux code: 45 82 98 99 74
Fitting: 1 x HPS 400W Tube Lamp (Correction
Factor 1.000).

Page 3
Arar
11.04.2022

Operator
Telephone
Fax
e-Mail

Street 1 / Valuation Field Roadway 1 / Observer 1 / Isolines (L)

Values in Candela/m², Scale 1 : 286

Grid: 12 x 6 Points
Observer Position: (-60.000 m, 3.250 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 1.95 0.42 0.73 4

Required values according to class ME4a: ≥ 0.75 ≥ 0.40 ≥ 0.60 ≤ 15

Fulfilled/Not fulfilled:

Page 4
Arar
11.04.2022

Operator
Telephone
Fax
e-Mail

Street 1 / Valuation Field Roadway 1 / Observer 2 / Isolines (L)

Values in Candela/m², Scale 1 : 286

Grid: 12 x 6 Points
Observer Position: (-60.000 m, 9.750 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 1.78 0.45 0.67 6

Required values according to class ME4a: ≥ 0.75 ≥ 0.40 ≥ 0.60 ≤ 15

Fulfilled/Not fulfilled:

Page 5
Arar
11.04.2022

Operator
Telephone
Fax
e-Mail

Street 1 / Valuation Field Roadway 2 / Observer 3 / Isolines (L)

Values in Candela/m², Scale 1 : 286

Grid: 12 x 6 Points
Observer Position: (-60.000 m, 18.250 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 1.78 0.45 0.67 6

Required values according to class ME4a: ≥ 0.75 ≥ 0.40 ≥ 0.60 ≤ 15

Fulfilled/Not fulfilled:

Page 6
Arar
11.04.2022

Operator
Telephone
Fax
e-Mail

Street 1 / Valuation Field Roadway 2 / Observer 4 / Isolines (L)

Values in Candela/m², Scale 1 : 286

Grid: 12 x 6 Points
Observer Position: (-60.000 m, 24.750 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 1.95 0.42 0.73 4