COMMENT RESOLUTION SHEET (CRS)

CLIENT M/s Oil & Natural Gas Corporation Ltd. CLIENT JOB NO 9655
CLIENT PMC M/s Triune Energy Services Pvt. Ltd. SOPAN JOB NO 21007
LSTK CONTRACTOR M/s Sopan O&M Company Pvt. Ltd. DATE 18-05-2023
PROJECT Construction Of Early Production System At Kasomarigaon, Jorhat Asset
Data sheet for Instrument Air Compressor & Heatless Dryer Package - Tag
DOC NAME
number L-600
DOC NO KSMG-EPS-ME-DS-IAC-A-023 Rev 2

Sr. Reference
COMMENT/ OBSERVATION RESOLUTION/ ACTION
No. Clause No.
Rev 1
Vendor to fill in the Deviation form with
PMC is not in agreement with change in PTR for Oil flooded Compressor instead
compressor type and will not be held responsible of Oil free type and Manufacturer
for the consequences. Contractor to submit the standard type instead of API 619 Code
deviation signed by ONGC/Contractor with PTR and submit signed Deviations for
as agreed during the meeting held on March Triune/ONGC approval.
2022.
Also, as per ISO code, please check the oil carry ELGi Reply – filled Data Sheet attached
Sheet 01
1. limitations and ensure the selected compressor for your reference.
of 11
carry less oil particulates than the limits
mentioned in code. This should be basis of Petrokens response dt 05.06.2023: To
deviation. SOPAN – The requirement of Deviation
Without deviation approvals, we will not the complete with PTR for Manufacturer
Compressor D/s. standard instead of API 619 type and Oil
Submit this CRS once the deviations are flooded Compressor instead of Oil-free
submitted and approved (For Sl.no 3 & 4 of CRS) compressor is not submitted by Vendor.
Please advise the way forward.
We have not reviewed this CRS unless the above Noted. The additional comments are
Sheet 01 concern is resolved. Also, few additional listed in this CRS complete with SOPAN’s
2.
of 11 comments are marked that required responses in the following rows of this
incorporation. CRS.
Refer Sl.no 1 response. Vendor to fill in
the Deviation form with PTR and submit
We still put Code-3 unless the deviations on
signed Deviations for Triune/ONGC
Sheet 04 compressor code is issued along with PTR and is
3. approval.
of 11 approved by client. Negative change shall be
included.
Petrokens response dt 05.06.2023:
Please refer response to Sl.no 1
4. Sheet 06 PMC requires the signed deviation from Refer Sl.no 1 response. Vendor to fill in
of 11 ONGC/Contractor with respect to change in the Deviation form with PTR and submit
compressor type and change in compressor signed Deviations for Triune/ONGC
design code from API 619 to 'manufacturer's approval.
standard'. PMC shall not be held responsible for ELGi reply – Please refer our response in
the consequences arising out such deviations. Sl. No. 1
Petrokens response dt 05.06.2023:
COMMENT RESOLUTION SHEET (CRS)
CLIENT M/s Oil & Natural Gas Corporation Ltd. CLIENT JOB NO 9655
CLIENT PMC M/s Triune Energy Services Pvt. Ltd. SOPAN JOB NO 21007
LSTK CONTRACTOR M/s Sopan O&M Company Pvt. Ltd. DATE 18-05-2023
PROJECT Construction Of Early Production System At Kasomarigaon, Jorhat Asset
Data sheet for Instrument Air Compressor & Heatless Dryer Package - Tag
DOC NAME
number L-600
DOC NO KSMG-EPS-ME-DS-IAC-A-023 Rev 2

Sr. Reference
COMMENT/ OBSERVATION RESOLUTION/ ACTION
No. Clause No.
Please refer response to Sl.no 1
Sheet 06
5. Contractor to provide the basis for MDMT. MDMT is based on the minimum
of 11
ambient temperature of 8°C.
Sheet 06 Noted. This is corrected in the revised
6. Contractor to rectify notes on this sheet.
of 11 Data sheet.
Corresponding relative humidity will be
as per Site conditions at Design dry bulb
Sheet 07 Contractor to add corresponding relative temperature of 40 Deg C. However,
7.
of 11 humidity here Design relative humidity of 100% is
considered for Air compressor package
(Page 6, Row 24)
Noted & confirmed. The Capacity
indicated is Net capacity. For Internal
consumption, Vendor shall verify and
add margin as per Note 8 (Page 10).
Sheet 08 Contractor to indicate the net capacity here (i.e.
8.
of 11 capacity excluding the internal IA requirement).
Vendor to verify the above statement
ELGi reply – Mentioned in Data sheet
Petrokens response dt 05.06.2023:
Noted & closed
Noted. This is updated in the revised
Data sheet.
Sheet 08 Vendor to verify the above statement
9. Contractor to add 'Max. 5 microns'
of 11 ELGi reply – Noted
Petrokens response dt 05.06.2023:
Noted & closed
LSTK to recheck frequency variation shall be as
Sheet 10 Noted. This has been updated in Revised
10. per electrical design basis doc no. "KSMG-EPS-EL-
of 11 data sheet
DO-EDB-A-001".
11. Sheet 10 LSTK to ensure area classification shall be as per As per HAC Layout, Instrument Air
of 11 approved Hazardous area classification layout. compressor and dryer package is under
safe area. However, as per
Instrumentation design basis all field
Instruments/Junction Boxes shall be
certified to Zone 2, IIA/IIB, T3. Therefore,
retaining the area classification as it is.
COMMENT RESOLUTION SHEET (CRS)
CLIENT M/s Oil & Natural Gas Corporation Ltd. CLIENT JOB NO 9655
CLIENT PMC M/s Triune Energy Services Pvt. Ltd. SOPAN JOB NO 21007
LSTK CONTRACTOR M/s Sopan O&M Company Pvt. Ltd. DATE 18-05-2023
PROJECT Construction Of Early Production System At Kasomarigaon, Jorhat Asset
Data sheet for Instrument Air Compressor & Heatless Dryer Package - Tag
DOC NAME
number L-600
DOC NO KSMG-EPS-ME-DS-IAC-A-023 Rev 2

Sr. Reference
COMMENT/ OBSERVATION RESOLUTION/ ACTION
No. Clause No.
Vendor to verify the above statement
ELGi Reply – Noted
Petrokens response dt 05.06.2023:
Noted & closed.
Vendor to confirm and provide response.

ELGi Reply - All items which are inside


Add in Notes; Vender to note and confirm that all
Sheet 11 the compressor and dryer like Electrical,
12. instruments are meeting to Instrument Design
of 11 instrumentation & piping shall be as per
Basis doc no 9655-09-DB-001 Rev.1.
Manufacturer Std.
Petrokens response dt 05.06.2023:
Noted & closed.