SWITCHER PROCESSOR PACK

MVS-6000-C

MULTI FORMAT SWITCHER PROCESSOR


MVS-6000

MKS-6470 MKS-8110G MKS-8161M MKS-8442G


MKS-8450G HK-PSU04 BZS-6250 BZS-6300
BZS-6420 BZS-6540M BZS-6550M

OPERATION MANUAL [English]


1st Edition
communications. Operation of this equipment in a residential
WARNING area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
To reduce the risk of fire or electric shock, expense.
do not expose this apparatus to rain or
You are cautioned that any changes or modifications not
moisture. expressly approved in this manual could void your authority to
operate this equipment.
To avoid electrical shock, do not open the
cabinet. Refer servicing to qualified All interface cables used to connect peripherals must be
personnel only. shielded in order to comply with the limits for a digital device
pursuant to Subpart B of Part 15 of FCC Rules.
THIS APPARATUS MUST BE EARTHED. This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must
AVERTISSEMENT accept any interference received, including interference that
may cause undesired operation.
Afin de réduire les risques d’incendie ou
d’électrocution, ne pas exposer cet For the customers in Canada
This Class A digital apparatus complies with Canadian
appareil à la pluie ou à l’humidité.
ICES-003.

Afin d’écarter tout risque d’électrocution,


Pour les clients au Canada
garder le coffret fermé. Ne confier
Cet appareil numérique de la classe A est conforme à la
l’entretien de l’appareil qu’à un personnel norme NMB-003 du Canada.
qualifié.
This symbol is intended to alert the user to the
CET APPAREIL DOIT ÊTRE RELIÉ À LA presence of important operating and
maintenance (servicing) instructions in the
TERRE. literature accompanying the appliance.

WARNING: THIS WARNING IS APPLICABLE FOR USA


WARNUNG ONLY.

Um die Gefahr von Bränden oder If used in USA, use the UL LISTED power cord specified
below.
elektrischen Schlägen zu verringern, darf DO NOT USE ANY OTHER POWER CORD.
dieses Gerät nicht Regen oder Feuchtigkeit
ausgesetzt werden. Plug Cap Parallel blade with ground pin
(NEMA 5-15P Configuration)
Cord Type SJT, three 16 or 18 AWG wires
Um einen elektrischen Schlag zu Length Minimum 1.5m (4 ft .11in.), Less than 2.5 m (8 ft .3 in.)
vermeiden, darf das Gehäuse nicht Rating Minimum 10A, 125V
geöffnet werden. Überlassen Sie
Wartungsarbeiten stets nur qualifiziertem Using this unit at a voltage other than 120V may require the
use of a different line cord or attachment plug, or both. To
Fachpersonal. reduce the risk of fire or electric shock, refer servicing to
qualified service personnel.
DIESES GERÄT MUSS GEERDET
WERDEN. WARNING: THIS WARNING IS APPLICABLE FOR OTHER
COUNTRIES.
For the customers in the U.S.A. 1. Use the approved Power Cord (3-core mains lead) /
This equipment has been tested and found to comply with the Appliance Connector / Plug with earthing-contacts that
limits for a Class A digital device, pursuant to Part 15 of the conforms to the safety regulations of each country if
FCC Rules. These limits are designed to provide reasonable applicable.
protection against harmful interference when the equipment is 2. Use the Power Cord (3-core mains lead) / Appliance
operated in a commercial environment. This equipment Connector / Plug conforming to the proper ratings (Voltage,
generates, uses, and can radiate radio frequency energy and, Ampere).
if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio

2
If you have questions on the use of the above Power Cord / Angewandte Normen:
Appliance Connector / Plug, please consult a qualified service • EN60950-1: Sicherheitsbestimmungen
personnel. • EN55103-1: Elektromagnetische Verträglichkeit
(Störaussendung)
• EN55103-2: Elektromagnetische Verträglichkeit
AVERTISSEMENT
(Störfestigkeit)
1. Utilisez un cordon d’alimentation (câble secteur à 3 fils)/
Für die folgenden elektromagnetischen Umgebungen: E4
fiche femelle/fiche mâle avec des contacts de mise à la terre
(kontrollierter EMV-Bereich, z.B. Fernsehstudio).
conformes à la réglementation de sécurité locale applicable.
2. Utilisez un cordon d’alimentation (câble secteur à 3 fils)/
fiche femelle/fiche mâle avec des caractéristiques For the customers in Europe (optional boards and
nominales (tension, ampérage) appropriées. HK-PSU04 only)
This product with the CE marking complies with the EMC
Pour toute question sur l’utilisation du cordon d’alimentation/ Directive issued by the Commission of the European
fiche femelle/fiche mâle ci-dessus, consultez un technicien du Community.
service après-vente qualifié. Compliance with this directive implies conformity to the
following European standards:
• EN55103-1: Electromagnetic Interference (Emission)
WARNUNG • EN55103-2: Electromagnetic Susceptibility (Immunity)
1. Verwenden Sie ein geprüftes Netzkabel (3-adriges This product is intended for use in the following
Stromkabel)/einen geprüften Geräteanschluss/einen Electromagnetic Environment: E4 (controlled EMC
geprüften Stecker mit Schutzkontakten entsprechend den environment, ex. TV studio).
Sicherheitsvorschriften, die im betreffenden Land gelten.
2. Verwenden Sie ein Netzkabel (3-adriges Stromkabel)/einen
Geräteanschluss/einen Stecker mit den geeigneten Pour les clients en Europe (cartes optionnelles et
Anschlusswerten (Volt, Ampere). HK-PSU04 uniquement)
Ce produit portant la marque CE est conforme à la Directive
Wenn Sie Fragen zur Verwendung von Netzkabel/ sur la compatibilité électromagnétique (EMC) émise par la
Geräteanschluss/Stecker haben, wenden Sie sich bitte an Commission de la Communauté européenne.
qualifiziertes Kundendienstpersonal. La conformité à cette directive implique la conformité aux
normes européennes suivantes:
• EN55103-1 : Interférences électromagnétiques (émission)
For the customers in Europe (MVS-6000 only) • EN55103-2 : Sensibilité électromagnétique (immunité)
This product with the CE marking complies with both the EMC Ce produit est prévu pour être utilisé dans l’environnement
Directive and the Low Voltage Directive issued by the électromagnétique suivant: E4 (environnement EMC contrôlé,
Commission of the European Community. ex. studio de télévision).
Compliance with these directives implies conformity to the
following European standards:
• EN60950-1: Product Safety Für Kunden in Europa (nur optionale Zusatzkarten und
• EN55103-1: Electromagnetic Interference (Emission) HK-PSU04)
• EN55103-2: Electromagnetic Susceptibility (Immunity) Dieses Produkt besitzt die CE-Kennzeichnung und erfüllt die
This product is intended for use in the following EMV-Richtlinie der EG-Kommission.
Electromagnetic Environment: E4 (controlled EMC Angewandte Normen:
environment, ex. TV studio). • EN55103-1: Elektromagnetische Verträglichkeit
(Störaussendung)
• EN55103-2: Elektromagnetische Verträglichkeit
Pour les clients en Europe (MVS-6000 uniquement) (Störfestigkeit)
Ce produit portant la marque CE est conforme à la fois à la Für die folgende elektromagnetische Umgebung: E4
Directive sur la compatibilité électromagnétique (EMC) et à la (kontrollierter EMV-Bereich, z.B. Fernsehstudio).
Directive sur les basses tensions émises par la Commission
de la Communauté Européenne.
La conformité à ces directives implique la conformité aux For the customers in Europe
normes européennes suivantes: The manufacturer of this product is Sony Corporation, 1-7-1
• EN60950-1 : Sécurité des produits Konan, Minato-ku, Tokyo, Japan.
• EN55103-1 : Interférences électromagnétiques (émission) The Authorized Representative for EMC and product safety is
• EN55103-2 : Sensibilité électromagnétique (immunité) Sony Deutschland GmbH, Hedelfinger Strasse 61, 70327
Ce produit est prévu pour être utilisé dans l’environnement Stuttgart, Germany. For any service or guarantee matters
électromagnétique suivants: E4 (environnement EMC please refer to the addresses given in separate service or
contrôlé, ex. studio de télévision). guarantee documents.

This apparatus shall not be used in the residential area.


Für Kunden in Europa (nur MVS-6000)
Dieses Produkt besitzt die CE-Kennzeichnung und erfüllt die
EMV-Richtlinie sowie die Niederspannungsrichtlinie der EG-
Kommission.

3
Pour les clients en Europe
Le fabricant de ce produit est Sony Corporation, 1-7-1 Konan,
Minato-ku, Tokyo, Japon.
Le représentant autorisé pour EMC et la sécurité des produits
est Sony Deutschland GmbH, Hedelfinger Strasse 61, 70327
Stuttgart, Allemagne. Pour toute question concernant le
service ou la garantie, veuillez consulter les adresses
indiquées dans les documents de service ou de garantie
séparés.

Ne pas utiliser cet appareil dans une zone résidentielle.

Für Kunden in Europa


Der Hersteller dieses Produkts ist Sony Corporation, 1-7-1
Konan, Minato-ku, Tokyo, Japan.
Der autorisierte Repräsentant für EMV und Produktsicherheit
ist Sony Deutschland GmbH, Hedelfinger Strasse 61, 70327
Stuttgart, Deutschland. Bei jeglichen Angelegenheiten in
Bezug auf Kundendienst oder Garantie wenden Sie sich bitte
an die in den separaten Kundendienst- oder
Garantiedokumenten aufgeführten Anschriften.

Dieser Apparat darf nicht im Wohnbereich verwendet werden.

For the customers in Europe, Australia and New Zealand


WARNING
This is a Class A product. In a domestic environment, this
product may cause radio interference in which case the user
may be required to take adequate measures.

Pour les clients en Europe, Australie et Nouvelle-Zélande


AVERTISSEMENT
Il s’agit d’un produit de Classe A. Dans un environnement
domestique, cet appareil peut provoquer des interférences
radio, dans ce cas l’utilisateur peut être amené à prendre des
mesures appropriées.

Für Kunden in Europa, Australien und Neuseeland


WARNUNG
Dies ist eine Einrichtung, welche die Funk-Entstörung nach
Klasse A besitzt. Diese Einrichtung kann im Wohnbereich
Funkstörungen verursachen; in diesem Fall kann vom
Betreiber verlangt werden, angemessene Maßnahmen
durchzuführen und dafür aufzukommen.

4
Table of Contents
Overview ............................................................................... 6
Features ..................................................................................... 6
Overview of the MVS-6000 Series Components ...................... 7
Location and Function of Parts .......................................... 8
Front Panel ................................................................................8
Rear Panel..................................................................................9
Example System Configuration ........................................ 11
MVS-6000 System Configuration...........................................11
Flow of Video Signals.............................................................12
Power Supply Unit Status Indicators ............................... 13
Specifications ..................................................................... 13
MVS-6000 Multi Format Switcher Processor......................... 13
MKS-6470 DME Board Set .................................................... 14
MKS-8110G 17-Input Board................................................... 14
MKS-8161M Monitor Output Board ...................................... 15
MKS-8442G Frame Memory Board ....................................... 15
MKS-8450G Format Converter Board.................................... 15
HK-PSU04 Power Supply Unit............................................... 15

Table of Contents 5
• Chroma key and color vector keys in each keyer
Overview • FineKeyTM, and key borders up to 8H
• Color mixable matte generator available for both key fill
and key borders
The MVS-6000-C Switcher Processor Pack is a high-
performance, multi-function processor for use in an Simultaneous output of two programs
MVS-6000 Multi Format Switcher system. It has a wide Each M/E bank is able to handle two simultaneous
range of application, being usable in live production program outputs, with the ability to apply any of the four
systems in studios and ENG/OB vans as well as in keys to program output. This gives the system the ability
postproduction editing systems. to handle a wide range of operating situations, for example
simultaneous transmission of two programs.
Features
Powerful preview functions
Multi format support The system supports simultaneous output of look-ahead
previews (next preview) and key previews, and also
The MVS-6000 system is available in two configurations: transition previews.
a multi-format SD/HD configuration and an SD-only
configuration. The SD-only configuration can be upgraded
to the multi-format configuration. Extended frame memory functions
• SD/HD multi format configuration • Two-input, eight-output frame memory
1080i/59.94, 1080i/50, 720P/59.94, 720P/50, 480i/ • Maintains all MVS-8000G/8000GSF frame memory
59.94, 576i/50 functions: freeze function, mask function, reposition
• SD-only configuration function, and image composition function
480i/59.94, 576i/50 • Approximately 5.4 GB large capacity memory
• Includes animation function
Key resizer functions • Interface connection for external hard disk drive
provided
• Magnify, shrink, move, change aspect ratio
• Two resizer channels are provided per M/E bank.
• Snapshots and keyframes Two channels of DME available
• Crop, Border By installing an optional DME board, you can apply DME
• Mosaic, Defocus wipes and processed keys and a wide variety of other DME
functions as if they were native switcher functions. All
Format converter functions DME functions can be controlled from the center control
panel of the MVS-6000 system.
• Input side format converter
Up-converter, down-converter, cross-converter
Eight channels Backup power supply can be installed
• Output side format converter By installing the optional HK-PSU04 Power Supply Unit,
Up-converter, down-converter, cross-converter together with the power supply unit preinstalled at the
Maximum two channels (requires at least one optional factory, this provides a backup system. This reduces the
MKS-8450G board) risk of power supply problems, and increases the reliability
of live operations.
Highly expandable system configuration
By combining option boards, you can configure the High-performance color correction
optimum system for your requirements, selecting the Installation of the optional MKS-8442G Frame Memory
number of inputs and outputs, and the number of M/E Board and BZS-6420 Color Corrector Software provides
banks. The system’s flexibility guarantees its ability to high-performance, two-channel color correction
meet future expansion requirements. functionality.

High-performance keyers Simple P/P (Program/Preset) functions


Each M/E bank is equipped with four high-performance Simple mix/effect functions can be added by installing the
keyers that provide the following standard functions. BZS-6250 Simple P/P Software option.
• Ability to apply transitions to keyers independently of The BZS-6250 option supports the following functions.
the background • Two keyers

6 Overview
• Background transitions and key transitions MKS-8442G Frame Memory Board
• Background DME wipe This is a frame memory board. One board can be installed
in the MVS-6000.
Overview of the MVS-6000 Series
Components MKS-8450G Format Converter Board
This is a format converter board. One board can be
installed in the MVS-6000.
MVS-6000 Multi Format Switcher
Processor
HK-PSU04 Power Supply Unit
This is the main unit cabinet of the MVS-6000 multi
format switcher processor unit (EIA 4RU size). This is a backup power supply unit. The MVS-6000 is
By default the main unit alone supports SD only, but it can equipped with a power supply unit preinstalled at the
be upgraded to multi-format HD/SD by installing an factory, and installing another unit provides a fully
optional software upgrade. redundant power supply.
• An M/E bank installed as standard; can be extended to
two M/E banks. BZS-6250 Simple P/P Software
• 15 inputs installed as standard; can be extended to 49
This is software which enables simple Program/Preset
inputs.
functions on the MVS-6000.
• 24 inputs installed as standard.
• Color corrector software (option) can be installed.
• A frame memory option board can be installed. BZS-6300 Additional M/E Software
• Up to one format converter board (option) can be This is software to enable the standard MVS-6000 with
installed. 8 inputs and 2 outputs. one M/E bank to be used as a two M/E system.
• A power supply unit fitted as standard.

The following options can be installed, depending on the BZS-6420 Color Corrector Software
system. This is software which enables high-performance color
correction of two channels. It supports both HD and SD.
Board Name Maximum The optional MKS-8442G Frame Memory Board must be
installable number installed to use this software.
of boards
MKS-6470 DME Board Set 1
BZS-6540M Switcher Upgrade Software
MKS-8110G 17-Input Board 2
This is software to upgrade a standard MVS-6000 (for SD;
MKS-8161M Monitor Output Board 1
with one M/E bank) to support multi-format switching.
MKS-8442G Frame Memory Board 1
MKS-8450G Format Converter Board 1
BZS-6550M Switcher Upgrade Software
HK-PSU04 Power Supple Unit 1
This is software to enable an M/E bank of the MVS-6000
(for SD; with one M/E bank) enabled by BZS-6300 to
MKS-6470 DME Board Set support multi-format switching.
This is an option board set to provide two-channel DME
functions. In the MVS-6000, one set can be installed.

MKS-8110G 17-Input Board


This is a 17-input board. The MVS-6000 has 15 inputs
fitted as standard, and by installing 17 inputs at a time with
this board, a maximum of 49 inputs (with two boards
added) can be reached.

MKS-8161M Monitor Output Board


This is an HD/SD eight-output board for monitoring input
signals. (This output board only carries out reclocking of
the input signal, and no other processing.) One board can
be installed in the MVS-6000.

Overview 7
Location and Function of Parts

Front Panel

POWER A, B switches and status indicators

POWER A, B switches and status indicators


The POWER switches turn the unit on and off. The unit is
powered on when the POWER switches are on the “ ? ”
side, and powered off when the POWER switches are on
the “a” side. The status indicators light in green when the
unit is powered on.
Depending on the configuration of your unit when
shipped, the HK-PSU04 Power Supply Unit may not be
installed. In this case, only the POWER A switch is
available. There is no POWER B switch. The unit does not
operate until either of the two power switches (A and B) is
on.
When the HK-PSU04 is installed, operation continues as
long as one power supply is normal.

Notes
• When installing the HK-PSU04 in your unit, be sure to
contact your Sony service representative.
• If a status indicator does not light when you turn a
POWER switch on, there may be a fault in the power
circuits. Turn the POWER switch off and contact your
Sony service representative.

8 Location and Function of Parts


Rear Panel

qfOUTPUTS 1 to 24 and FC 1, 2 connectors


qdMONITOR OUT 25 to 32 connectors
qsPRIMARY INPUTS 1 to 49 connectors 1-AC IN A and B connectors

2U terminal

qaREF INPUT connectors 3FM DEVICE connector


0DATA connector 4GPI connector
9FM DATA connector 5REMOTE 1 to 4 connectors
8CTRL connector 6DME CTRL connector
7DME DATA connector

a - AC IN (AC power input) A and B connectors Define the types of the connected devices on the center
(3-pin) control panel.
Connect to 100 to 240 V AC power supply with the
optional AC power cords. f DME CTRL (Digital multi effect control)
Depending on the configuration of your unit when connector (RJ-45 compliant) (MKS-6470)
shipped, the HK-PSU04 Power Supply Unit may not be Connect to an Ethernet* switch.
installed. In that case, the AC IN B connector is not used. The MVS-6000 system’s center control panel is connected
in the same way to the Ethernet switch to form a network
Note for exchange of signals between the devices.
For information about installing an HK-PSU04 Power This network is used primarily to control the various
Supply Unit, contact your Sony service representative. devices from the center control panel of the MVS-6000
system.
b U (signal ground) terminal
Connect to the system ground. g DME DATA (Digital multi effect data) connector
(RJ-45 compliant) (MKS-6470)
c FM (frame memory) DEVICE connector Connect to an Ethernet* switch.
(IEEE1394 compliant) The MVS-6000 system’s center control panel is connected
This connector is for attaching an external hard disk drive in the same way to the Ethernet switch to form a network
for frame memory. for exchange of signals between the devices.

For details of hard disk drives that can be used with the h CTRL (control) connector (RJ-45 compliant)
MVS-6000 system, consult your Sony service Connect to an Ethernet* switch.
representative. The MVS-6000 system’s center control panel is connected
in the same way to the Ethernet switch to form a network
d GPI (General Purpose Interface) connector (D-sub for exchange of signals between the devices.
25-pin) This network is used primarily to control the various
Connect to external devices for input and output of trigger devices from the center control panel of the MVS-6000
signals. Up to eight inputs and eight outputs are possible, system.
with input and output conditions set on the center control
panel. i FM DATA (frame memory data) connector (RJ-45
compliant)
e REMOTE 1 to 4 connectors (D-sub 9-pin, RS-422A Connect to an Ethernet* switch. This is a dedicated LAN
compliant) connector for image data.
These connectors are used to control the auxiliary bus of
the MVS-6000 series from external devices, or to operate j DATA connector (RJ-45 compliant)
the MVS-6000 from editing control systems such as the Connect to an Ethernet* switch.
BVE-9100.

Location and Function of Parts 9


The MVS-6000 system’s center control panel is connected k REF INPUT (reference video input) connectors
in the same way to the Ethernet switch to form a network (BNC-type)
for exchange of signals between the devices. If you wish to synchronize this unit to an external reference
This network is used primarily for exchange of various signal, input the reference signal. For an HDTV system,
types of data (key frame effects, snapshots, etc.) and still input an HD tri-level sync signal, black burst signal, or
pictures of frame memory. analog sync signal. For an SDTV system, input a black
burst signal or analog sync signal.
CAUTION The two connectors have a loop-through configuration.
• When you connect the FM DATA connector, DATA Signal input to one connector can be output from the other
connector, CTRL connector, DME CTRL connector, connector. If you will not be using the loop-through
and DME DATA connector of the unit to peripheral output, be sure to terminate the unused connector with the
devices, use a shielded-type cable to prevent supplied 75Ω terminator.
malfunction due to radiation noise.
• For safety, do not connect the connector for peripheral l PRIMARY INPUTS 1 to 49 connectors (BNC-type)
device wiring that might have excessive voltage to the These connectors can be used to input up to 49 serial
following port(s). digital video signals.
- FM DATA (frame memory data) connector The number of these connectors (slots) depends on the
- CTRL (control) connector number of MKS-8110G boards that are installed in the
- DATA connector unit.
- DME CTRL (digital multi effect control) connector These connectors allow you to connect with an
- DME DATA (digital multi effect data) connector MVE-8000A Multi Format DME Processor.
Follow the instructions for the above port(s).
m MONITOR OUT connectors 25 to 32 (BNC-type)
* For information about Ethernet switches that can be used in an MVS-6000 (MKS-8161M)
system, contact your Sony service representative.
These are used for auxiliary output to a primary input
monitor or external device. These outputs are useful for
ATTENTION outputting a primary input signal with as little delay as
Par mesure de sécurité, ne raccordez pas le connecteur possible.
pour le câblage de périphériques pouvant avoir une tension
excessive aux ports suivants. n OUTPUTS 1 to 24 connectors (BNC-type)
- FM DATA connecteur These connectors output serial digital signals. You can
- CTRL connecteur assign them freely as program output, preview output,
- DATA connecteur AUX output, and so on.
- DME CTRL connecteur Outputs 1, 2, 13 to 16 are each constituted by two BNC-
- DME DATA connecteur type connectors, and outputs 3 to 12, 17 to 24 are each
Suivez les instructions pour les ports ci-dessus. constituted by one BNC-type connector.
Make output assignments on the MVS-6000 system center
VORSICHT control panel.
Aus Sicherheitsgründen nicht mit einem Peripheriegerät-
Anschluss verbinden, der zu starke Spannung für diese Refer to the User’s Guide for information about signals
Buchse haben könnte. that may be assigned.
- Buchse FM DATA
- Buchse CTRL FC1 and 2 (slot 2) connectors (BNC-type): MVS-6000
- Buchse DATA (MKS-8450G)
- Buchse DME CTRL The connectors output signals converted with the format
- Buchse DME DATA converter function.
Folgen Sie den Anweisungen für die oben aufgeführten Assign the outputs on the center control panel of the MVS-
Buchsen. 6000 system.

For more information about Ethernet switch connectors,


see “MVS-6000 System Configuration” (page 11).

For detailed information about setting up the Ethernet


switch, refer to the documentation supplied with the
switch.

10 Location and Function of Parts


Example System Configuration

MVS-6000 System Configuration

VTR DDR Audio Mixer

MKS-2700 Device
Control Unit
MVS-6000 Multi Format
Switcher Processor

Reference
video signal b)
BKS-R Series

IXS Series
MKS-8010B System
Reference Control Unit
video signal b)

Reference video signal b)

Reference video signal b) MVE-8000A-C


DME Processor Pack c)

BVE-9100 Editing
Ethernet switch a) Ethernet switch a) Control System

Cable with BNC-type connectors

Cross cable

a) It is recommended that the CTRL and DATA LAN networks be b) Terminate with the supplied 75Ω terminators.
configured by connecting separate Ethernet switches for each c) With MKE-8021A installed.
LAN.

Example System Configuration 11


Flow of Video Signals

Monitor

MVE-8000A-C DME
Processor Pack d)

Reference video signal c)

Monitor
100 to 240 V AC power supply a)

VTR

MVS-6000 Multi Format


Switcher Processor

Monitor

Camera,
VTR, Reference video signal c)
routing
switcher
100 to 240 V AC power supply b)

Video input signal, Video output signal

AC power supply

a) For the AC power cord of the MVE-8000A, refer to the MVE- c) Terminate with the supplied 75Ω terminators.
8000A Operation Manual. d) With MKE-8021A installed.
b) For the AC power cord of this unit, see page 14.

12 Example System Configuration


Power Supply Unit Status Specifications
Indicators
The following specifications show the reference
performance for this unit and individual option boards/
The power supply unit status indicators show the status of units.
the power supply unit during operation and when the unit
is powered on. Whenever a power error is detected, it is Design and specifications are subject to change without
reflected immediately by the indicator. notice.

Meaning of status indicator displays


MVS-6000 Multi Format Switcher
Indicator Status Description Steps to take Processor
color
Green Lit Operating normally −
Red Lit Power supply unit fan Exchange the
General
fault fan unit Power requirements
− Not lit Power supply unit Exchange the 100 to 240 V ±10% AC, 50/60 Hz
fault power unit Current consumption
100 V: 7 A, 240 V: 3 A
Note Peak inrush current
When the unit is powered on, the status indicators may (1) Power ON, current probe method: 42
light momentarily in red and a whining sound may be A (100 V), 45 A (240 V)
heard. This is not a malfunction. Power all of the installed (2) Hot switching inrush current,
power supply units on. measured in accordance with
European standard EN55103-1: 36 A
(230 V)
Operating temperature
5ºC to 40ºC (41ºF to 104ºF)
Performance guaranteed temperature
10ºC to 35ºC (50ºF to 95ºF)
Storage temperature
−20ºC to +60ºC (−4ºF to +140ºF)
Operating humidity
10% to 90%
Dimensions (w/h/d, excluding projections)
482×176×520 mm (19×7×201/2 inches)
Mass Approx. 26 kg (57 lb 5.1 oz) (when
equipped with all installable option
boards and option power supply unit)

Remote control connectors


CTRL RJ-45, Complies with 100Base-TX
standard
DATA RJ-45, Complies with 100Base-TX
standard
REMOTE 1, 2, 3, 4
D-sub 9-pin, female
Comply with RS-422A standard
Data transfer rate: 38.4 Kbps
GPI D-sub 25-pin, female
TTL inputs: 8
Relay contact outputs: 4 (30 V AC/DC,
0.1 A)
Open collector outputs: 4

Power Supply Unit Status Indicators / Specifications 13


Reference input
Note
REF INPUT BNC type, 75Ω with loop-through output Always verify that the unit is operating properly before
HDTV system: HD tri-level sync/SDTV use. SONY WILL NOT BE LIABLE FOR DAMAGES
analog black burst/SDTV analog sync OF ANY KIND INCLUDING, BUT NOT LIMITED
SDTV system: Analog black burst/ TO, COMPENSATION OR REIMBURSEMENT ON
analog sync ACCOUNT OF THE LOSS OF PRESENT OR
Return loss –40 dB PROSPECTIVE PROFITS DUE TO FAILURE OF
THIS UNIT, EITHER DURING THE WARRANTY
Frame memory input and output PERIOD OR AFTER EXPIRATION OF THE
FM DATA RJ-45, complies with 100Base-TX WARRANTY, OR FOR ANY OTHER REASON
standard WHATSOEVER.
FM DEVICE Complies with IEEE1394
MKS-6470 DME Board Set
Video input
Inputs 15 (BNC-type) Power requirements
Signal format SMPTE292M/SMPTE259M-C DC 12 V DC
Signal level 0.8 Vp-p ±10% Power consumption
Signal transfer rate Max. 100 W
1.5 Gbps/270 Mbps Dimensions (w/d)
Return loss −15 dB DVP-49 board: 317×380mm (12 1/2×15
Cable length HDTV system: 100 m (5C-FB cable, inches)
BELDEN1694 or equivalent) CA-54 board: 317×380mm (12 1/2 ×15
SDTV system: 200 m (5C-FB cable, inches)
BELDEN1694 or equivalent) Mass 3 kg (6 lb 9.8 oz)
Accessories supplied
Operation and Installation Guide (1)
Video output (supplied only when product is
Outputs 24 (BNC-type) purchased separately)
1, 2, 13 to 16: BNC 2 outputs
3 to 12, 17 to 24, FC1, FC2: BNC 1
outputs MKS-8110G 17-Input Board
Signal format SMPTE292M/SMPTE259M-C
Signal level 0.8 Vp-p ±10% General
Signal transfer rate
1.5 Gbps/270 Mbps Power requirements
Return loss –15dB 12 V DC
Power consumption
Max. 10 W
AC input Dimensions (w/d)
AC IN A, B 3-pin AC connector 274×94 mm (107/8×33/4 inches)
Mass Approx. 1 kg (2 lb 3.3 oz)
Accessories supplied
75Ω terminator (1) Input
Brackets (4) Inputs 17 (BNC-type)
Support angles (2) Signal format SMPTE292M/SMPTE259M-C
Screws (+B4×10) (8) Signal level 0.8 Vp-p ±10%
Screws (+PSW4×10) (8) Signal transfer rate
Operation Manual (1) 1.5 Gbps/270 Mbps
Installation Manual (1) Return loss −15 dB
Cable length HDTV system: 100 m (5C-FB cable,
BELDEN1694 or equivalent)
Accessories not supplied SDTV system: 200 m (5C-FB cable,
AC power cord (for USA and Canada only) (125 V 10 A BELDEN1694 or equivalent)
2.4 m (8 ft)) (Part No.: 1-551-812-31)
AC power cord (for Europe only) (250 V 10 A 2.4 m
(8 ft)) (Part No.: 1-782-929-12)

14 Specifications
Accessories supplied (supplied only when product is purchased
Operation and Installation Guide (1) separately)
(supplied only when product is purchased separately)
HK-PSU04 Power Supply Unit
MKS-8161M Monitor Output Board Power requirements
Input power: 100 to 240 V ±10% AC,
General 50/60 Hz
Output power: 12 V DC ±0.3 V
Power requirements
Current consumption
12 V DC
10 to 5 A
Power consumption
Secondary power supply
Max. 10 W
Max. 60 A
Dimensions (w/d)
Dimensions (w/h/d)
274×94 mm (107/8×33/4 inches)
94×83×396 mm (33/4×33/8×155/8 inches)
Mass Approx. 1 kg (2 lb 3.3 oz)
Mass Approx. 3 kg (6 lb 9.8 oz)
Accessories supplied
Output Operation and Installation Guide (1)
Outputs 8 (BNC-type), each with 2 outputs (supplied only when product is
Signal format SMPTE292M/SMPTE259M-C purchased separately)
Signal level 0.8 Vp-p ±10%
Signal transfer rate
1.5 Gbps/270 Mbps
Return loss –15 dB

Accessories supplied
Operation and Installation Guide (1)
(supplied only when product is purchased separately)

MKS-8442G Frame Memory Board


Power requirements
12 V DC
Power consumption
Max. 100 W
Dimensions (w/d)
317×380 mm (121/2×15 inches)
Mass Approx. 2 kg (4 lb 6.5 oz)
Accessories supplied
Operation and Installation Guide (1)
(supplied only when product is
purchased separately)

MKS-8450G Format Converter Board


Power requirements
12 V DC
Power consumption
Max. 50 W
Dimensions (w/d)
317×380 mm (12 1/2×15 inches)
Mass Approx. 1.5 kg (3 lb 4.9 oz)
Accessories supplied
Operation and Installation Guide (1)

Specifications 15
The material contained in this manual consists of information
that is the property of Sony Corporation and is intended solely
for use by the purchasers of the equipment described in this
manual.
Sony Corporation expressly prohibits the duplication of any
portion of this manual or the use thereof for any purpose other
than the operation or maintenance of the equipment described
in this manual without the express written permission of Sony
Corporation.
.

Sony Corporation
MVS-6000 Printed in Japan
(SY) 2009.03 13
4-144-243-01 (1) Printed on recycled paper. © 2009