1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

ALL SHEETS ARE THE REVISIONS


DATUM
SAME REVISION STATUS ZONE LTR DESCRIPTION DATE APPROVED
A LOCATION -INITIAL RELEASE 08-17-17 L.PEDRINI A
REVISED.REMOVED
A DETAIL D.ADDED 04-20-18 L.PEDRINI
1623159-12
ROLLED TO -101.
1496683-101 WAS -100,
B 1623159-70 WAS -12. 10-18-22 M.VIGANO
7 ADDED 2071654-100 AND
B 2046223-101. B
8 B

18 B

C C
17 B

4X B

19 20 21
D D

E 9 10 11
E
32X 32X 32X

1 B

F F

13 3X

B
2X 2
G G

12 3X
4 5 6 H
H
2X 2X 2X

14 6X

B
J J

K K

4 5 6

4X 4X 4X
15

L L
16

3 4 1485058 BOLT,HEX,M10-1.5MMX 30MM,A2 21


4 1454750 LOCKWASHER,SPLIT,M10,304 SS 20
4 5 6 B 4 1455385 WASHER,FLAT,M10X 20 MMX 1.6 MM 19
3 2046223-101 PIPE ASSY,VENT,GAS 18
2X 2X 2X
M 1 2071654-100 BRACKET,VENT,NG 17 M
1 N/A GASKET, 30x6MM L=8520,PVC, ADHESIVE SEE NOTE 6 16
1 N/A GASKET, 30x6MM L=7900,PVC, ADHESIVE SEE NOTE 6 15
6 964418C1 UNION,TUBE,CPRSN,1.0 14
B
3 1623159-70 TUBE,1.00 OD,T:UNION,F:UNION 13
9 1559398-100 KIT,HDWR,CLAMP,1'' 12
32 1484047 BOLT,HEX,M6-1.0MMX 20MM,A2,304 11
N N
32 1454748 LOCKWASHER,SPLIT,M6,304 SS 10
32 980438C1 WASHER,FLAT,M6X 18.59X 1.48 9
1 1496685-200 DUCT,HOOD,VENT 8
1 1496685-100 DUCT,HOOD,VENT 7
8 1485076 BOLT,HEX,M12-1.75MMX 50MM,A2 6
8 1454751 LOCKWASHER,SPLIT,M12,304 SS 5
P NOTES: 8 1461193 WASHER,FLAT,M12X 34.0 MMX 2.5 4
P
1 1507234-100 SILENCER,INL,STRAIGHT 3
1. ALL PIPING AND TUBING OPENINGS MUST BE CONVENIENT SEALED TO AVOID DIRT ENTERING DURING 2 1496684-1 BRACKET,EXH DUCT,40X40X20MM 2
STORAGE AND TRANSPORTATION. B 1 1496683-101 DUCT,HOOD,VENT 1
QTY QTY QTY PART NOMENCLATURE OR MATERIAL FIND
ZONE
2. ALL BOLTING HARDWARE AND PIPING/TUBING FITTINGS HAVE TO BE PULLED TO THE RULES OF ART, IF MOUNTED. REQD REQD REQD NUMBER DESCRIPTION SPECIFICATION NO.
B
-101 ASSY NO. PARTS LIST
3. DUCT LINING NOT SHOWED. UNLESS OTHERWISE SPECIFIED THIS COPYRIGHTED WORK AND THE INFORMATION HEREIN IS PROPRIETARY TO CATERPILLAR INC., SOLAR TURBINES INCORPORATED, AND/OR SUBSIDIARIES OF
EITHER. WITHOUT EXPRESS, WRITTEN PROPRIETOR PERMISSION, ANY COPYING, DISCLOSURE, OR USE EXCEPT THAT FOR WHICH IT IS LOANED, IS PROHIBITED.
Q DIMENSIONS ARE IN MILLIMETERS Q
4. EACH ELEMENT MUST HAVE AN IDENTIFICATION LABEL FOR SITE ASSEMBLY. USE FIRST THE CODE OF THE PART GENERAL TOLERANCES:
DATA
CONTROL
RELEASE
STAMP
CONTRACT NO. P.O. BOX 85376
OR THE ASSEMBLY, IF NOT AVAILABLE THE FN IDENTIFICATION CODE WITH THE DRAWING NUMBER. LEVEL SAN DIEGO, CALIFORNIA
ISO 2768-MK 11/22/22 DRAWN 92186-5376
TATA TECH 04-20-18

1
CHECKED
5. ALL FASTENERS HARDWARE (BOLTS, SCREWS, WASHERS, NUTS, CLAMPS, ETC) HAVE TO BE OF STAINLESS STEEL CDM L. PEDRINI 04-20-18
MATERIAL, CLASS A2 MINIMUM QUALITY (IF NOT ELSE SPECIFIED). LYT
VENTILATION AIR OUTLET
CHIMNEY ASSY
FIRST ANGLE PROJECTION CUSTOMER ENGR L.PEDRINI 04-20-18
6. ROW MATERIAL: 1556724-1
DO NOT SCALE DRAWING LAYOUT MFG
R -0.2 +0.5 NHA LEAD
7. PERFORATED METAL SHEET IS FOR REFERENCE ONLY, TO SHOW WHERE LINING HAS TO BE APPLIED. -0.5 +0.2 ENGR SIZE CAGE CODE DWG NO.
R
A0 66195 1506786
MODEL
IT IS THE SUPPLIER RESPONSIBILITY TO DEFINE THE FINAL METAL SHEET CUTTING.
CAD IDENT Released B.2 SCALE: 1:20 TOTAL WT: 1714 KG SHEET 1 OF 2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

TRANSPORTATION AND SITE ASSEMBLY INFORMATION


A

LIFTING RINGS
SEE NOTE 11
B B

>45 $ (2
X)

(2091 )

C C

D D

(2341 )

E DETAIL B E

3.

F
(2906 )
2. 3.
DETAIL
A-A
1.
E-E
F 2. F
SECTION VIEW
1.

DETAIL F 1 1
SCALE 1:10 2
REF REF
G REF G
6
TRANSPORT CONFIGURATION 6
REF
REF
5

5 3 REF

C-C
H REF REF 4 H
SECTION
SCALE 1:5 REF
4 6X

DETAIL B REF

DETAIL G SCALE 1:2


2X NATURAL GAS VENT
J (2381.1 ) J

SITE ASSEMBLY
K OPENINGS FOR K
SEE NOTE 10 SYPHON DRAIN
MUST LOOK AFT.

(2906 ) (1423 )
DETAIL G
SCALE 1:10 L
L WIRES REMOVED FOR CLARITY

NOTE 12

M M

1. NATURAL GAS VENT LINE 1


N NOTE 13 N
2. NATURAL GAS VENT LINE 2
3. NATURAL GAS VENT LINE 3

NOTES:
P P
8. ALL ELEMENTS MOUNTED OUTSIDE THE SHAPE OF THE DUCT AND ALL HARDWARE
FOR SITE ASSEMBLY MUST BE PACKED (WATER RESISTANT) AND FASTENED INSIDE THE DUCT (IF POSSIBLE).

9. BEFORE TRANSPORTATION, UPPER SIDE OF THE DUCT MUST BE CLOSED WITH A PLASTIC SHEET TO AVOID
RAIN TO ENTER. USE PARTICULAR CARE IN THE AREA OF THE LIFTING EYEBOLTS.

10. USE ONLY 4 BOLTS AND PLACE ALL OTHERS BOLTS AND THE TUBING INSIDE THE DUCT FASTENED TO THE NET IN THIS COPYRIGHTED WORK AND THE INFORMATION HEREIN IS PROPRIETARY TO CATERPILLAR INC., SOLAR TURBINES
INCORPORATED, AND/OR SUBSIDIARIES OF EITHER. WITHOUT EXPRESS, WRITTEN PROPRIETOR PERMISSION, ANY

Q SUCH A WAY THEY DO NOT GET LOOSE OR DAMAGED. COPYING, DISCLOSURE, OR USE EXCEPT THAT FOR WHICH IT IS LOANED, IS PROHIBITED.
Q
P.O. BOX 85376
11. THE DUCT MUST BE LIFTED ONLY THROUG THE 2 FILTING RINGS. IT IS NOT ALLOWED TO HANG OTHER DUCTS UNDER SAN DIEGO, CALIFORNIA
92186-5376
THIS ONE DURING LIFTING. FAILURE TO HEED THE FOLLOWING INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR
DEATH. LIFTING ROPES SUPPLIED BY OTHERS.
1506780-10X
VAE DUCT VENTILATION AIR OUTLET
12. PIPES HAVE TO BE CONNECTED BOTTOM TO TOP, FROM THE ENCLOSURE TO THE CHIMNEY.
CHIMNEY ASSY
R 13. GASKET MUST BE LAY IN A CLOSED LOOP. NO INTERRUPTIONS ARE ALLOWED.

D-D
SIZE CAGE CODE DWG NO.
R
14. CENTRE OF GRAVITY IS PLACED IN THE CENTRE OF THE DUCT. SECTION A0 66195 1506786
SCALE: 1:20 TOTAL WT: 1714 KG SHEET 2 OF 2