1506786-100 Ventilation Air Outlet Chimney Assy
1506786-100 Ventilation Air Outlet Chimney Assy
18 B
C C
17 B
4X B
19 20 21
D D
E 9 10 11
E
32X 32X 32X
1 B
F F
13 3X
B
2X 2
G G
12 3X
4 5 6 H
H
2X 2X 2X
14 6X
B
J J
K K
4 5 6
4X 4X 4X
15
L L
16
1
CHECKED
5. ALL FASTENERS HARDWARE (BOLTS, SCREWS, WASHERS, NUTS, CLAMPS, ETC) HAVE TO BE OF STAINLESS STEEL CDM L. PEDRINI 04-20-18
MATERIAL, CLASS A2 MINIMUM QUALITY (IF NOT ELSE SPECIFIED). LYT
VENTILATION AIR OUTLET
CHIMNEY ASSY
FIRST ANGLE PROJECTION CUSTOMER ENGR L.PEDRINI 04-20-18
6. ROW MATERIAL: 1556724-1
DO NOT SCALE DRAWING LAYOUT MFG
R -0.2 +0.5 NHA LEAD
7. PERFORATED METAL SHEET IS FOR REFERENCE ONLY, TO SHOW WHERE LINING HAS TO BE APPLIED. -0.5 +0.2 ENGR SIZE CAGE CODE DWG NO.
R
A0 66195 1506786
MODEL
IT IS THE SUPPLIER RESPONSIBILITY TO DEFINE THE FINAL METAL SHEET CUTTING.
CAD IDENT Released B.2 SCALE: 1:20 TOTAL WT: 1714 KG SHEET 1 OF 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
LIFTING RINGS
SEE NOTE 11
B B
>45 $ (2
X)
(2091 )
C C
D D
(2341 )
E DETAIL B E
3.
F
(2906 )
2. 3.
DETAIL
A-A
1.
E-E
F 2. F
SECTION VIEW
1.
DETAIL F 1 1
SCALE 1:10 2
REF REF
G REF G
6
TRANSPORT CONFIGURATION 6
REF
REF
5
5 3 REF
C-C
H REF REF 4 H
SECTION
SCALE 1:5 REF
4 6X
DETAIL B REF
SITE ASSEMBLY
K OPENINGS FOR K
SEE NOTE 10 SYPHON DRAIN
MUST LOOK AFT.
(2906 ) (1423 )
DETAIL G
SCALE 1:10 L
L WIRES REMOVED FOR CLARITY
NOTE 12
M M
NOTES:
P P
8. ALL ELEMENTS MOUNTED OUTSIDE THE SHAPE OF THE DUCT AND ALL HARDWARE
FOR SITE ASSEMBLY MUST BE PACKED (WATER RESISTANT) AND FASTENED INSIDE THE DUCT (IF POSSIBLE).
9. BEFORE TRANSPORTATION, UPPER SIDE OF THE DUCT MUST BE CLOSED WITH A PLASTIC SHEET TO AVOID
RAIN TO ENTER. USE PARTICULAR CARE IN THE AREA OF THE LIFTING EYEBOLTS.
10. USE ONLY 4 BOLTS AND PLACE ALL OTHERS BOLTS AND THE TUBING INSIDE THE DUCT FASTENED TO THE NET IN THIS COPYRIGHTED WORK AND THE INFORMATION HEREIN IS PROPRIETARY TO CATERPILLAR INC., SOLAR TURBINES
INCORPORATED, AND/OR SUBSIDIARIES OF EITHER. WITHOUT EXPRESS, WRITTEN PROPRIETOR PERMISSION, ANY
Q SUCH A WAY THEY DO NOT GET LOOSE OR DAMAGED. COPYING, DISCLOSURE, OR USE EXCEPT THAT FOR WHICH IT IS LOANED, IS PROHIBITED.
Q
P.O. BOX 85376
11. THE DUCT MUST BE LIFTED ONLY THROUG THE 2 FILTING RINGS. IT IS NOT ALLOWED TO HANG OTHER DUCTS UNDER SAN DIEGO, CALIFORNIA
92186-5376
THIS ONE DURING LIFTING. FAILURE TO HEED THE FOLLOWING INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR
DEATH. LIFTING ROPES SUPPLIED BY OTHERS.
1506780-10X
VAE DUCT VENTILATION AIR OUTLET
12. PIPES HAVE TO BE CONNECTED BOTTOM TO TOP, FROM THE ENCLOSURE TO THE CHIMNEY.
CHIMNEY ASSY
R 13. GASKET MUST BE LAY IN A CLOSED LOOP. NO INTERRUPTIONS ARE ALLOWED.
D-D
SIZE CAGE CODE DWG NO.
R
14. CENTRE OF GRAVITY IS PLACED IN THE CENTRE OF THE DUCT. SECTION A0 66195 1506786
SCALE: 1:20 TOTAL WT: 1714 KG SHEET 2 OF 2