Draft for public consultation.

End Date : 2015-01-09 NA to I.S. EN 206:2014

1 Table NA.3 — Cements for which specific suitability is established

Composition (percentage by mass)

Main constituents
Designation in Minor
Description
I.S. EN 197-1 Blast-furnace Fly Ash additional
Clinker Limestone
slag (siliceous) constituents
K S V L or LL
Portland-slag
CEM II/B-S 65-79 21-35 0-5
cement
Portland- fly ash
CEM II/B-V 65-79 21-35 0-5
cement
CEM II /A-M Portland-
80-94 NOTE 1 NOTE 1 0-5
(S-L) or (S-LL) composite cement

CEM II /A-M Portland-


80-94 NOTE 1 NOTE 1 0-5
(S-V) composite cement

CEM II /A-M Portland-


80-94 NOTE 1 NOTE 1 0-5
(V-L) or (V-LL) composite cement

I
CEM II /B-M Portland-
65-79 NOTE 2 NOTE 2 0-5
(S-L) or (S-LL) composite cement
SA
CEM II /B-M Portland-
65-79 NOTE 2 NOTE 2 0-5
(S-V) composite cement

CEM II /B-M Portland-


65-79 NOTE 2 NOTE 2 0-5
(V-L) or (V-LL) composite cement

Blastfurnace
CEM III/A 35-64 36-65 0-5
cement
Blastfurnace
CEM III/B 20-34 66-80 0-5
cement
NOTE 1 The total percentage of the two main constituents other than clinker will lie in the range 6% - 20%.
N

NOTE 2 The total percentage of the two main constituents other than clinker will lie in the range 21% - 35%.

3 NA.2.3 Aggregates (subclause 5.1.3)

4 The subject of recycled aggregate is referred to in subclause 5.1.3(2) and 5.2.3.4 and Annex E and their
5 suitability for use in Ireland has yet to be established. Use of such aggregates should be by agreement of the
6 parties involved on a project by project basis

7 NOTE A flakiness index of Fl50 is recommended for flakiness for both natural normal weight and heavyweight
8 aggregates and for air cooled blast furnace slag and for coarse recycled aggregates (Tables E.1 and E.3)

9 NA.2.4 Admixtures (subclause 5.1.5)

10 No additional guidance provided.

11 NA.2.5 Basic requirements for composition of concrete - General (subclause 5.2.1)

12 Annex A of I.S. EN 206 provides details for initial testing to establish a concrete that satisfies all specified
13 requirements for fresh and hardened concrete.