1 2 3

RB I RB I

E E

2
3

3
1

1
2# -16Ø Main 2# -16Ø Main 2# -16Ø Main 2# -16Ø Main 2# -16Ø Main 2# -16Ø Main
2# -12Ø Extra 2# -12Ø Extra 2# -12Ø Extra 2# -12Ø Extra

1'
12'-3"
RB I

RB I
RB I
2# -16Ø Main 2# -12Ø EXTRA 2# -16Ø Main 2# -16Ø Main 2# -12Ø EXTRA 2# -16Ø Main
2# -16Ø Main 2# -16Ø Main

2
3

3
1

1
L/4=3'-1.5'' L/2=6'-3'' L/4=3'-1.5'' L/4=3'-0'' L/2=6'-0'' L/4=3'-0''
L=12'-6'' L=12'0''
RB I RB I
SECTION A-A
D D
2# -16Ø Main 2# -16Ø Main 2# -16Ø Main 2# -16Ø Main 2# -16Ø Main 2# -16Ø Main
2# -12Ø Extra 1# -12Ø Extra 2# -12Ø Extra 2# -12Ø Extra 1# -12Ø Extra 2# -12Ø Extra

1'

1'

1'

1'

1'

1'
1# -12Ø Extra 2# -12Ø Extra 1# -12Ø Extra 1# -12Ø Extra 2# -12Ø Extra 1# -12Ø Extra
9'' 2# -16Ø Main 9'' 2# -16Ø Main 9'' 2# -16Ø Main 9'' 2# -16Ø Main 9'' 2# -16Ø Main 9'' 2# -16Ø Main

ROOF Beam RB ROOF Beam RB ROOF Beam RB ROOF Beam RB ROOF Beam RB ROOF Beam RB
C/S 1 - 1 C/S 2 - 2 C/S 3 - 3 C/S 1 - 1 C/S 2 - 2 C/S 3 - 3
RB I RB I RB I RB I RB I RB I
RB I

17'-2"
RB I

RB I

RB I RB I
ROOF BEAM DETAILS
C C
A A REINFORCEMENT REINFORCEMENT
MAIN BAR EXTRA BAR
6'-11"
RB I

RB I

NAME SIZE
TOP BOTTOM TOP BOTTOM
RB I

RB I

B B

RB I 0'9''X1'0'' 2# -16Ø 2# -16Ø 2# -12Ø 2# -12Ø


RB I

5'-1"

RB I

A A

13'-5" 12'-9"
1 2 3
ROOF BEAM LAYOUT

REV DATE NOTES ORIENTATION PROJECT:-


GBV PLANNERS AND BUILDERS
PROPOSED RESIDENTIAL BUILDING AT CDM
GRADE OF CONCRETE M20 (1:1.5:3 ) CONFORMING TO IS456-2000 DOOR NO.48A,RAMASWAMY COMPLEX,
STEEL GRADE FE500 Fy = 500 N/mm2
PATTAMANGALA STREET,
CLEAR COVER TO REINFORCEMENT
BEAM - 25 MM
TITLE:- MAYILADUTHURAI,
COLUMN - 40 MM
ROOF BEAM LAYOUT & DETAILS PINCODE-609001.
W

SLAB - 20 MM
E
N

DEVELOPMENT LENGTH IN MM MOBILE: +91 9842378586


LDT = DEVELOPMENT LENGTH IN TENSION (=47Ø)
E-MAIL : raghugbv@gmail.com
W

LDC = DEVELOPMENT LENGTH IN COMPRESSION (=38Ø)


Ø=BAR DIAMETER DWG NO: DATE: SHEET NO:
THIS DRAWING SHOULD BE READ IN CONJUCTION WITH OTHER
SE

ARCHITECTURAL AND STRUCTURAL DRAWING


SW
S
SD -7 03 -06-2023 1 OF 1
REINFORCEMENT DETAIL IN COLUMN AS PER IS456 2000