Partida 37

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Detector

ZFK8

217
40
L (mm)

Zirconia Oxygen Analysers Standard applications High temperature applications


35
Detector
Detector
ZFK8
ZFK8

Standard guide tube Dual flange guide tube for high temperature

Simple, fast, robust and QAL1 certified


- high temperature ZFKH probe Detector
- high temperature alloy tube ZFK8

170 190 Approx. L


Ideal for combustion control in boilers,

Ø 42.7
Detector

Ø 30
incinerators and furnaces ZFK8

Lowering CO₂, SOx, and NOx emissions


while saving energy High particulate applications

217
Guide tube with back purge ZTA ejector module
O2 Principle 40
L (mm) 500 750 1000 1500
The analyser makes use of the property of zirconium
oxide that conducts oxygen ion when heated. The 35
analyser can obtain O₂ concentration by sensing the
electromotive force generated by the difference of O₂
concentration between air and the sample gas.
Flow guide tube Ceramic filter
Heater Flange
Direct tube for high particulate
Reference gas

Output
Sample
gas
IP66 IP67 Electrode Zirconia element
Extractive applications
Converter Converter
ZKMA ZKMB Flow Through Cell (FTC)

Easily replaceable zirconia element Direct tube for high particulate with deflector

Detecto
Flow guide tube ZFK8

Detector ZFK8
Specifications
Target
Principle
O2 in incombustible gas
Insertion type zirconia sensor
Model selection
Range 0 … 2 … 50 vol% O2 (user configurable)
Repeatability ±0.5% FS Select the required modules combination according to the process conditions using below table.
Linearity ±2% FS
Process conditions Modules selection
Response time
4s…7s Application
(for 90%) Temperature Dust Tube Detector
Output signal 4–20 mA DC or 0–1 V DC example material backpurge Tube type Tube code (*) type

 points, SPST-NO contact: H/L limit alarm, during mainte-


6 Gas boiler ≤ 600 °C ≤ 0,1 g/Nm3 No Standard guide tube 631B562-0#
Bypass by Weather Contact output
nance, during blowdown, during calibration, analyser error ≤ 5 g/Nm3 Yes Guide tube with backpurge 631B563-0#
Protection cover CTK SS316 ZFK8
ZTA ejector Contact input  volt-free contacts: selection from 7 items
3 ≤ 600 °C Yes Direct tube for high particulate 631B673-0#
≤ 25 g/Nm3
Display Backlit LCD Biomass, Oil, Yes Direct tube for high particulate with deflector 631B677-0#
Communication RS-485 Modbus® or HART Coal boiler ≤ 0,2 g/Nm3 No Dual flange guide tube for high temperature 631B685-0#
Features  ombustion efficiency display, blowdown,
C /Incinerator ≤ 5 g/Nm3 Yes Dual flange guide tube for high temperature with backpurge 631B684-0#
Optional functions ≤ 1000 °C SS310
auto calibration, selector valve, flowmeter Yes Direct tube for high temperature and high particulate 631B675-0#
■ Longest lifetime sensor ≤ 25 g/Nm3 ZFKH
Yes Direct tube for high temperature and high particulate with deflector 631B678-0#
■ Easily replaceable zirconia element reducing maintenance cost Detecting a break of the thermocouple for heater control
in the sensor unit, the analyser stop the power supply Incinerator / ≤ 0,2 g/Nm3 No Guide tube for very high temperature 631B682-0#
■ User friendly
≤ 1300 °C Kanthal
Safety functions
to the detector Furnace / ≤ 5 g/Nm3 Yes Guide tube for very high temperature with backpurge 631B683-0#
■ No instrument air required The power supply to the detector may also be stopped Glass / ≤ 800 °C SS310 Yes ZTA ejector module ZTA2
by external input in an emergency ≤ 0,5 g/Nm3 ZFK8
■ No Flue gas extraction required
Metal industry ≤ 1500 °C SiC Yes ZTA ejector module ZTA1
The key lock function prevents operational errors
■ Fast response (4–7 seconds)
(*) The last digit of the tube code is dedicated to the tube insertion length as per below list:
Converter
Panel mount or pipe mount Notes
■ Predictive and advanced diagnostics
installation '3' =
'1' = 300mm '2' = 500mm '4' = 1000mm 'Z' = special length -> consult Fuji
Cable length 750mm
■ IP66 or IP67 enclosure between converter ≤ 100m
■ RS-485 or HART communication and detector (1) In case of very humid gas, keep the flange hot enough to prevent condensation
Power supply (2) In case of highly corrosive gas, please consult Fuji for special materials
100–120 V AC or 200–240 V AC, 50/60 Hz
voltage (3) If the gas flow is lower than 5 m/s, use ejector module instead of flow tube

30 31