USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 1 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00
Effective Date:

Performance Qualification
Document for
Auto coating system
(V/PRD/ACS001)

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 2 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00
Sr. No. Description Page No.
1. PQ Document Pre- Approval 3
Validation/ Qualification Team.
2. 4-5
2.1 Training
3. Objective 6
4. Scope 6
5. Responsibilities 6

6. Equipment Description 7

Procedure
7. 7.1 Product Name 7-17
7.2 Operation Carried out
Verification of Standard Equipment/ Master Instrument used for
8. 18
qualification
9. Final Conclusion 19

10. PQ Document Post Approval 20

11. Qualification Certification 21

12. Document revision history 22

1. PQ Document Pre-Approval

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 3 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00

Responsibility Name Designation Signature & Date

Prepared By
(Production Dept.)

Checked By
(Engineering Dept.)

Checked By
(Production Dept.)

Review By
(Quality Assurance)

Review By
(Plant Head)

Approved By
(QA Head)

2. Validation/ Qualification Team

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 4 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00

Validation/ Qualification Team

Responsibility Name Designation Signature & Date

2.1
Train-
ing:
Production Dept. Training
to be
imparted
to all the
involved
person
Engineering Dept.
(Qualifi-
cation/
Valida-
tion
Quality Assurance team) in
Dept. the exe-
cution of
Perfor-
mance
qualifi-
cation document for Auto coating system.
Training Time: From ………… to ………….

Sr. No. Trainee Name Designation/ De- Employee code Sign / Date
partment

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 5 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00

Remarks:

Trainer Name:
Sign/ Date:
3. Objective:
3.1. To verify the Auto coating system performance with dummy /Trial/validation product as
intended and as per process parameters mentioned in Batch Manufacturing Record.
3.2. To record all relevant information and data observed during performance qualification.
3.3. To demonstrate that the results of the performance trials of the Auto Coating system
consistently meets the predetermine specifications under normal operating condition.
4. Scope:
The protocol describes the performance qualification parameters along with the procedure

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 6 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00
and acceptance criteria for Auto coating system (V/PRD/ACS001) installed in Coating-1
area (Room ID. No. F87) of Production department in Formulation Facility at USV private
limited, Vadodara.

5. Responsibilities:
Sr.
Department Responsibility
No.
 To prepare and check the Performance Qualification Protocol.
 To ensure operation, recording & check of performance data as
Production per the procedure outlined in this protocol.
1
Department
 To compile the documents required during Performance Qualifi-
cation.
 To check the Performance Qualification Protocol.
 To assist in ensuring the Performance activity during Perfor-
mance qualification.
2 Engineering  To check the data generated during Performance Qualifica-
tion.
 To assist in ensuring the Performance activity as per safety re-
quirement.
Quality  To perform the quality test as mention in this Protocol.
3
Control

Quality  To withdraw sample and to review the Performance Qualification


4 results and its compliance with respect to acceptance criteria.
Assurance

6. Equipment Description
Equipment Name : AUTO COATING SYSTEM
Equipment Code : V/PRD/ACS001
Location : Coating-1 (F87)
Capacity : 1850 Liter

Effectiveness for implementation of below listed SOP’s/documents shall be ensured

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 7 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00
before
start of the performance qualification activities.
Sr. Document No./ Verified By
Document Name Effective Date
No. SOP No. Sign/date

SOP for operation and cleaning of


1. VMF-SOP-0027
Autocoating system.

7. Procedure:
7.1. Product Name:
Product Name and Batch No.
1st Batch:
Product Name: ______________________________________________________________

Batch No.: ______________________

2nd Batch:
Product Name: ______________________________________________________________

Batch No.: ______________________

3rd Batch:
Product Name: ______________________________________________________________

Batch No.: ______________________

7.2. Operation Carried Out:


7.2.1. Performance Qualification Procedure:
Procedure for Film Coating:
1. Start the Auto coating system as per starting procedure (as par reference SOP).
2. Measure the Pan RPM of Automatic coating system with respect to set RPM using
calibrated tachometer.
3. Perform Gun validation and spray rate determination of peristaltic pump.

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 8 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00
4. Check inlet air temperature of Auto coating system with respect to set value.
5. Check exhaust air temperature of Auto coating system with respect to set value.
6. Measure the Peristaltic Pump RPM of Auto coating system with respect to set RPM
using calibrated tachometer.
7. Visually check the 100% discharging of coated tablet.
8. Record the observation of weight of tablets and calculate the weight gain.
9. Repeat the same process for the three consecutive dummy /Trial/validation batches.
10. Record the observation in respective table.

7.2.2. Sampling Plan: In process checks for tablet weight gain and appearance as per
respective BMR.

7.2.3. Acceptance Criteria and Target Value:

Acceptance Criteria and Target


Test Name Frequency
Value

Verification of Pan RPM It should be ± 1 RPM of set RPM Before start of the batch

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 9 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00

Verification of Appearance at As per specification in BMR and free


the end of Charging of tablets in from defects.
Three Batches/Lots
coating pan After Charging of tablets no any
physical damage observed.

Verification of coating parameter


Inlet Air Temperature It should be ± 5°C of set value

Exhaust Air Temperature Should not exceed its high set value

Peristaltic Pump RPM It should be ± 1 RPM of set RPM

Atomization Pressure It should be ± 0.6 bar of set value


As per specification in BMR and as
Weight Gain (% w/w) per requirement in case of dummy
batch

As per specification in BMR and free Three Batches/Lots


Verification of appearance and from defects in case of dummy tablets
Discharging at the end of
coating After discharging not a single tablet
should remain in coating pan
Direction of coating pan should be
clockwise in coating process
Verification of Direction of
coating pan Direction of coating pan should be
anti-clockwise in discharging process.

Before loading of core tablets in auto coating system perform Pan RPM and Gun validation
test as mention below.
7.2.4. Verification of Pan RPM:
Observation table for verification of Pan RPM
Tachometer ID No:_____________________

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 10 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00
Acceptance criteria: It should be ±1 RPM of set RPM.

Checked By
Sr. Batch/Lot Set Pan Observed Target Done
Date
No. No. RPM RPM value By
Prod. QA

7.2.5. Gun validation and spray rate determination of peristaltic pump.


Spray gun diameter: ____________________ No. of Spray Gun: _____________________

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 11 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00
Measuring cylinder ID: ___________________
Weighing balance ID: ____________________
Stop watch ID: _________________________

Spray Done Checked


Batch/ Spray Rate (g/min/gun) Total
Date pump By By
Lot No.
RPM 1 2 3 4 5 6 7 8 9 10 Prod QA

7.2.6. Verification of Appearance at the end of Charging of tablets in coating pan:


After Loading of Tablets in coating pan, visually check the tablet appearance

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 12 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00
Acceptance Criteria:
Appearance: As per specification in BMR and free from defects.
Charging: After Charging of tablets no any physical damage observed.

Appearance at the Checked By


end of Charging
Sr. No. Batch/ Lot No. Date Done By
of tablets (Ok/
Not Ok) Prod. QA

7.2.7. Observation table for verification of coating parameter:


Tachometer ID No:_____________________

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 13 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00
Acceptance Criteria:
Inlet Air Temp : ± 5 °C of set value.
Exhaust Air Temp : Should not be exceed its high set value.
Pump RPM : ± 1 RPM of set RPM.
Atomization Pressure : ±0.6 bar of set value.
Sr. Batch/ Target Done Checked By
Parameter Date Set Actual
No. Lot No. Value By Prod QA

Inlet Air
1
Temp. (°C)

Exhaust Air
2
Temp. (°C)

3 Pump RPM

Atomization
4
Pressure (bar)

7.2.8. Verification of Appearance and Discharging at the end of coating:

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 14 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00
Acceptance Criteria:
Appearance: As per specification in BMR and free from defects.
Discharging: After discharging not a single tablet should remain in coating pan.
Appearance
Discharging Checked By
Sr. Batch/ Lot at the end of Done
Date (Satisfactory/ Not
No. No. coating (Ok/ By
Satisfactory) Prod. QA
Not Ok)

7.2.9. Verification of Direction of Coating pan:

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 15 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00

Acceptance Criteria:
During Coating process: Direction of coating pan during Coating should be clockwise.

Direction of Checked By
Batch/ Lot
Date coating pan during Done By
No.
Coating
Prod. QA

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 16 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00

Acceptance Criteria:
During Discharging process: Direction of coating pan during Discharging should be anticlockwise.

Direction of Checked By
Batch/ Lot
Date coating pan during Done By
No.
Discharging
Prod. QA

7.2.10. Acceptance Criteria:

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 17 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00
Test Batch No. Batch No. Batch No.
Specifications
Parameter

Description

Average

Weight (mg) As per BMR


Thickness

(mm)

Length (mm)

Width (mm)

Weight Gain
(% w/w)

Checked by

Production Dept. Quality Assurance Dept.


8. Verification of Standard Equipment/ Master Instrument used for qualification:
1.1. The description, identification and validity of calibration (as applicable) of the test equip-
ments/ master instruments shall be listed in this section.

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 18 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00
1.2. Attach the copy of calibration certificates of these equipments (as applicable) with the
qualification report.

List of Standard Equipment/ Master Instrument used for qualification


Calibration
Instrument/ Recorded
Sr. Instrument Next
Equipment Calibration By
No. ID No. Traceability Due
Name Done Date (Sign/Date)
Date

Remarks:

Checked by

Production Dept. Quality Assurance Dept.


9. Final Conclusion:
-----------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 19 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00
-----------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------

Checked by

Production Dept. Quality Assurance Dept.


10. PQ Document Post Approval:

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 20 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00
Responsibility Name Designation Signature & Date

Compiled By
(Production Dept.)

Checked By
(Engineering Dept.)

Checked By
(Production Dept.)

Review By
(Quality Assurance)

Review By
(Plant Head)

Approved By
(QA Head)

11. Qualification Certification:

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 21 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00

QUALIFICATION CERTIFICATE
Performance Qualification of_______________________________

Equipment No.___________________________________________

Was conducted according to PQ Document No._________________

Performance Qualification Completed on______________________

And the Equipment is released for____________________________

_____________ _____________

HOD Production Dept. QA Head


Sign/Date Sign/Date

12. Document Revision History

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.
Form No: VEG-SOP-0001/10.6-01
CONFIDENTIAL-USV
USV PRIVATE LIMITED

Reference SOP No: GQA-SOP-0001


PERFORMANCE QUALIFICATION DOCUMENT FOR AUTO COATING Page No.: 22 of 22
SYSTEM
Document No.: V/PQ/PRD/ACS001-00
Document revision History
Sr. No. Date of Revision Revision No. Reason for Revision
(Effective date)

1 NA 00 New Protocol

USV Private Limited, Plot No 538 to 540, 597 to 625, GIDC Industrial Area - Savli, Taluka - Savli, Manjusar, Vadodara, Gujarat - Pincode - 391775.