NORTHERN RAILWAY
Head Quarters Office
Baroda House
New Delhi
No. 224-Elect /TUPT. XX Dated:12.11.2021
Sr. Divl .Elect Engineer/Chg
N. Rly. New Delhi.
Sr. Divl Elect Engineer/G
N. Rly, Ambala, Firozepur, Lucknow, Moradabad.
Dy. Chief Elect. Engineer
Jagadhri Workshop. Alambagh Lucknow,
‘Sub:-Modification Sheet no. | RDSO/PE/MS/TL/0083-2021(REV-0) for
modification for shifting of residual current breaker with over-current
(RCBO) positioning in set of panels for LHB Non-AC EOG/HOG Coaches.
Ref: - RDSO letter no. EL/7.1.108/SBC/355 dated 12.08.2021
Find enclosed herewith a copy of Subjected Modification Sheet issued by RDSO
for your kind information and necessary action,
Jeio—.
"4
eekly
Dy. Chief Elect. Engineer/Chg.
DA: As above.svete — te tree
xqeerensforen te sr TT
Tele: +91-522-2465739
Fax: +91-522-2465717 na: att
irmeve@gmail.com Government of india- Ministry of Rallways
ome a esearch, Designs & Standards Organization, LUCKNOW —
ee 226011
EL/7.1.108/SBC/355 Date 12.08.2021
Wer Fer Rega soiree
Beam Sak Mears Aaa Ree AAAS 6 Mae | SHO MD CHO, MGT, 144 602 (FTA)
11, ate ere, 7A aE 400 14
[aemertores, fg 00 098 wai aa Gal aria cath aR weeeINIDO
EH GS aif sonra
qi tee Saedt Ga sieeve 700 071 ater Rae, TRE 773 001
Gar tae. Wale ETOH WRT 110 00 Taare otter Rat ra 902 006
wea tad, Hee A GH Gl — 400 007 iene Hore ta, ia, rere 764 O17
waa tee wee, Hae 00 020 gar we a, SATS 482 001
or We Sea Trea Ara, wera 700 043
aaa Fak eign Fea Foren Sere, ewe [ete wer tel 7 wet te Prova Reecare
bas 101 500 071
Se Ea a Rie ea GR [att her ee Fo eH
751 023 (581) args, veer ws gach 500 020
Sem tae ESREe ame GRITS, | sisi ot Rae, FReTEgE 496 004
Eevee 217 033
‘Sub: Modification sheet no. RDSO/PE/MSITL/0083-2021 (
of residual current breaker with over-current (RCBO) p¢
Non AC EOG/HOG Coaches.
Ref: ) Railway Board's letter No. 2009/Elect(G)/109/14 dtd. 01.03.2021.
ji) NER letter No. L/55/Performance/MCP dated 20.01.2021
[ sitet Rea, ure ere, Wig 600 003
Rev-0) for modification for shifting
ing in set of panels for LHB
Vide letter under reference above, Railway Board has advised RDSO to examine the
issue raised by NE Railway vide reference (i).
by NER under reference (ii) above and
33-2021 (Rev-0) for modification for shifting of
{RCBO) positioning in set of panels for LHB Non AC
your information and further necessary action
ne
(itendrd Yadav)
DSE/MRVC
For Director General /PS & EMUPage 1 of 4 | EL/7.1.108/SBC/Non AC LHB coaches Modification Sheet No. RDSO/PE/MS/TLIO/0E
‘Aug, 2024 2021(Rev.0)
vom
ANT WOR
Net Hare
GOVERNMENT OF INDIA
MINISTRY OF RAILWAYS
RESEARCH DESIGN AND STANDARD ORGANISATION
MANAK NAGAR LUCKNOW - 226011
POWER SUPPLY & EMU DIRECTORATE
MODIFICATION FOR SHIFTING OF RESIDUAL CURRENT BREAKER WITH OVER-
CURRENT (RCBO) POSITIONING IN SET OF PANELS FOR LHB NON AC EOG/HOG
COACHES.
MODIFICATION SHEET NO. RDSO/PE/MS/TL/0083-2021 (Rev 0)
‘sn | DATE OF AMENDMENT
AMENDMENT No.
PAGE NO. REASON FOR AMENDMENTJ Page 2 of 4 | EL/7.1,108/SBCiNon AC LHB coach
MODIFICATION FOR SHi
CURRENT (RCBO}
'es | Modification Sheet No. RDSO/PE/MS/TLION
Aug, 2021 | 2021(Rev.0)
IFTING OF RESIDUAL CURRENT BREAKER WITH OVER-
) POSITIONING IN SET OF PANELS FOR LHB NON AC EOGIHOG
COACHES.
1s
Objective: Shifting of RCBO location in Set of panels from underslung cubicle (HV
box) to onboard cubical (LV box),
His
STORY: Railway Board vide letter no. 2009/Elect (G)/109/14 dated 01.03.2021
has instructed to examine the issue raised by NE Railway regarding shifting of
RCBO from underslung cubicle (HV box) to onboard cubical (LV box). RCBO is
located in undersiung cubicle (HV box), therefore, it is not possible to reset it after
Spurious tripping during enroute running of the train. It is also observed that reset is
only possible, when the train stops at next upcoming stoppage with condition that
underslung cubicle (HV box) is on other side of the platform
‘The proposal of NE railway has been examined and found to be justified to shift
RCBO location in set of panels from undersiung cubicle (HV box) to onboard
Cubical (LV box). Based on the above, this modification has been prepared to
eliminate the enroute problem of maintenance issue of RCBO
Location of RCBO: At present RCBO is located in underslung HV cubicle.
t
Undersiung cubicle (HV. Section ‘A’
Prepared by
Checked byVi
EU7.1.108/SBCINon AC LHB coaches
Aug, 2021
Modification Sheet No. RDSO/PE/MS/TLIO/083-
Aug, 2024(Rev.0)
4 Shifting of RCBO in set of panels from undersiung cubicle (HV box) to
onboard cubical (LV box):
44 Changed location of RCBO i.e. in Onboard LV panel:- in this condition while
Tunning the rolling stock, if RCBO- get tripped it is possible to reset it, due to its
location in onboard cubical (LV box).
42
Adding of one rotary switch 10A, 4pole, ON/OFF for mobile charging socket. This
provision is made in compliance to Railway Board letter no.
2000/Eleo(G)/113/4/Safety dated 19.06.2014.
4.3 Sifting of RCBO to be carried out as per RCF drawing No. CC72082 (Annexure-1)..
4.4 COMPARISION OF RCBO POSITIONING IN HV cubicle & LV PANEL
EXISTING POSITION (BEFORE MODIFICATION)
Fuse for Mobile
charging socket3 [m= 40f4 | EL/7.1.108/SBC/Non AC LHB coaches PEI
Modification Sheet No.
| ____Aug, 2021 2021 (Rev.0) ice acadlaiaal
AFTER MODIFICATION POSITION REFERENCE DRAWING NO, CC72082
RCBO in onboard
(LV) panel
Bem:
Underslung (HV) cubical ‘Onboard (LV) cubical
4.5 Following componentsiItems relocated/added during modification:
‘a. ROBO is relocated from underslung (HV) panel to On board (LV) panel.
be Rotary switch, 410A, 4pole, ON/OFF for mobile charging socket is added.
depots/ coaching workshops holding of Non AC LHB
eS
DirectorIMRVCfeels] «] «| fe 4] 4] #