Professional Documents
Culture Documents
Qi 2016 J. Electrochem. Soc. 163 C131
Qi 2016 J. Electrochem. Soc. 163 C131
Society
OPEN ACCESS
In this work, the influence of water immersion post-treatment, with consideration of temperature and pH values, on trivalent chromium
conversion coating morphologies, compositions and corrosion protection has been investigated, using high-resolution transmission
electron microscopy, energy-dispersive X-ray spectroscopy and electrochemical impedance spectroscopy. Compared to the coating
formed without the water immersion post-treatment, the post-treatment in the deionized water bath at 40◦ C evidently reduced the
concentrations of fluorine-containing constituents and increased the extent of oxides/hydroxides across the coating. Consequently, the
enhanced corrosion protection property was investigated in the post-treated coatings during full immersion in naturally-aerated NaCl
solution with mass fraction of 3.5%. In terms of water pH effects, the coatings displayed comparable thicknesses after post-treatment
in the as-prepared deionized water bath (pH 5) and neutral water bath (pH 7); However, a considerable shrinkage was observed in
the caustic water bath (pH 9). It was found that the resultant corrosion resistance of the coatings was greatest after post-coating
treatment in the water bath of pH 5 and the least for pH 9. Inductively coupled plasma-atomic emission spectroscopy was used to
trace small amounts of Zr and Cr elements in the used water baths. A robust chemical titration, adding 1, 5-diaminonaphthalene into
the used water baths, revealed that Cr species were only in trivalent form.
© The Author(s) 2016. Published by ECS. This is an open access article distributed under the terms of the Creative Commons
Attribution 4.0 License (CC BY, http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse of the work in any
medium, provided the original work is properly cited. [DOI: 10.1149/2.0221605jes] All rights reserved.
Manuscript submitted November 30, 2015; revised manuscript received January 7, 2016. Published January 15, 2016.
For AA2024 aluminum alloy, the presence of copper and mag- agents, is a promising process in providing an eco-friendly solution.
nesium elements increases the alloy susceptibility to localized In this sense, understanding the influencing parameters of the water
corrosion.1 Therefore, chromate conversion coatings were used to im- bath post-treatment on the corrosion protection performance is of great
prove the surface resistance against corrosion by a dipping process.2 importance for an eco-friendly coating process.
However, the toxic hexavalent chromate species in chromate con- In the present study, high-resolution transmission electron mi-
version coatings are an ecological concern and, hence, the chromate croscopy, associated with energy-dispersive X-ray spectroscopy, and
conversion coating process has been highly regulated by legislation electrochemical impedance spectroscopy have been used to investi-
such as the Restriction of Hazardous Substances (RoHS).3 gate the effects of temperature and pH values of the deionized water
In this regard, trivalent chromium conversion (TCC) coatings are bath on the coating morphology, composition and corrosion protection
a promising alternative due to the low toxicity of trivalent chromium performance.
species.4 Such coating process on AA2024 alloy, driven by the in-
creased pH, consists of surface activation by fluorine attack and coat-
ing initiation around second-phase particle and lateral growth on the Experimental
macroscopic alloy surface.5-7 The freshly-formed coatings have many Specimens and preparations.—AA2024-T351 alloy (supplied by
hydrated channels and the post-treatment in air for 24h can reduce the Airbus, U.K.) specimens with dimensions of 30 × 24 mm were first
coating porosity to enhance the corrosion protection while maintaining cleaned with acetone, ethanol and deionized water, and then mechan-
the hydrated structure.8 In terms of coating structure, Zr-and Cr-rich ically polished from 400 up to a 4000 grit finish. The etching and
oxides comprise the outer layer above a fluoroaluminate layer.9,10 No- desmutting pre-treatment proceeds as follows: (i) etching in NaOH
tably, a significant amount of fluoride constituent at the coating base solutions of mass fraction 5% at 60◦ C for 60 s and (ii) desmutting
was found and it correlated with the locally enhanced corrosion of in HNO3 solution of volume fraction 50% at room temperature for
aluminum substrate,6 which was assigned with the fluorine attack.11 30 s. All the pre-treatments were followed rinsing with deionized
Fluoride accumulation, especially after prolonged conversion treat- water and drying in a cool-air stream.
ment, is a composition challenge for the optimal coating process to After such pre-treatments, the alloy specimens were coated in
provide sufficient corrosion resistance. SurTec 650 chromitAL bath (SurTec Corp) at pH 3.9 and 40◦ C for
After the conversion treatment in the trivalent chromium-based 120, 300 and 600 s, followed by immersion in the deionized water
solution, immediate tap-water rinsing for 120 s has been used to offer bath (∼200 ml) for 120 s. For the parameters of the deionized water
reproducible structure and performance, for reasons that currently bath, the temperature ranged from 20◦ C (cold water) to 40◦ C (warm
remain unclear.5,12 Furthermore, the use of more basic tap water (pH water). The pH value of as-received deionized water at 40◦ C was
6.8) was critical to stabilize the hydroxide constituents in the coating approximately 5 and the pH levels of 7 and 9 of the warm water
compared with ultrapure water (pH 5.8).5 In this sense, the post- bath were created by addition of NaOH droplets with mass fraction
coating treatment in a water bath to replace the water rinsing process of 1%. Subsequently, the specimens were rinsed by deionized water,
is expected to play a similar role in stabilizing the coatings.6 In this dried in a cool-air stream and left in the laboratory for 24 h before the
regard, the stabilization mechanism was possibly related to a sealing experimental tests. The specimen codes for the coatings without water
process in reducing the coating defects, which has been revealed immersion treatment, immersion in the cold water and immersion in
in an anodic film after boiled water post-treatment.12,13 In terms of the warm water are I, II and III, respectively.
the Cr(VI) species formed in the air-aged TCC coatings on AA2024 In order to investigate the chemistry of Cr species, the chemical
alloys,5,14 the water immersion post-treatment, by adding reducing titration methodology was used as detailed by Rochester et al.15 Com-
pared to the Cr(III) species, the reagent of 1, 5-diaminonaphthalene
(1, 5-DPL) is highly sensitive to the presence of Cr(VI) species to
∗ Electrochemical Society Member. generate the violet-purple complex, being a robust titration test for
z
E-mail: alexanderinmanchester@gmail.com Cr(VI). In the present study, the solution of 5 g / 1, 5-DPL (97%,
C132 Journal of The Electrochemical Society, 163 (5) C131-C138 (2016)
50
48
47
Thickness / nm
46
44
43
42 42
40
(a) (c)
50
(b)
45
44 44
Thickness / nm 40
35
34
(d)
30
pH 5 pH 7 pH 9
Water pH effects
Figure 5. (a,b,c) Transmission electron micrographs and (d) corresponding thickness plots of the TCC coatings formed for 300 s in a dilute SurTec 650 bath at
40◦ C, with dependence on the pH values of the warm deionized water in the immersion post-treatment.
A mass fraction of ∼5% fluorine was measured in the coating solution of mass fraction 3.5% (indicated by the arrow, Figure 8b). It
without the water immersion post-treatment. Furthermore, the atomic pertained to the chloride ion effects, for example, either a diffusion
ratios of fluorine relative to the combined metals of Al, Zr and Cr process within a chloride layer on the surface of bare alloy23 or the
were 0.04, 0.05 and 0.15 for the specimens after treatments III, II and faradaic process of the localized corrosion.24
I, respectively. It revealed a significant decrease of fluorine-rich com- In terms of specimens II (Table II), the charge-transfer resistance,
ponents after the water immersion treatment, especially for the 40◦ C Rp , revealed an increased magnitude of ∼15 times in the coating
condition, attributed to the enhanced diffusion kinetics of free fluorine formed for 300 s compared to that of the bare alloy (∼3.3 × 103
ions away from the coating region.19 In addition to the improved fluo- cm2 ). By contrast, a small decrease of charge-transfer resistance was
rine content, the oxygen mass fractions of 40 and 30% were measured evident in the coating formed for 600 s, which could be attributed to
in the coatings after treatments III and I, respectively, and the corre- the presence of fluorine enrichment at the coating base.6 For the coat-
sponding atomic ratios of oxygen with respect to the combined metals ing resistances (Rcoat ), the increased values from 45 cm2 (120 s) up
were 3.4 and 2.4, respectively. For the surface chemistry of anodic to 153 cm2 (600 s) were associated with thickening of the coating
film, Alexander et al.20 used the variable-angle XPS and medium- with prolonged conversion treatment. For the capacitance property,
energy ion scattering (MEIS) to reveal a hydroxyl-rich surface region Figure 9b shows one time constant around ∼101 Hz for the bare
of thickness that varied linearly with the total oxide thickness. The alloys, while two visible time constants (∼101 and 104 Hz) were pre-
formation of a hydroxyl-rich outermost layer was associated with the sented for the coated specimens. The constant phase elements (CPEs)
gel-like materials at the film/electrolyte interface. In this regard, the were used to represent the non-ideal capacitance because their phase
higher oxygen constituents in the TCC coated alloy matrix, being angles were less than 90◦ . In terms of the coating region (Qcoat and
in the form of oxides and hydroxides,21 suggested a more hydrated ncoat ), the higher value of Qcoat (1.2 × 10−5 sn /( cm2 )) and lower ho-
coating after water treatment. mogeneity ratio of ncoat (0.81) in the coating formed for 120 s revealed
the most heterogeneous coating on the alloy surface. It is associated
Electrochemical behavior.—The influencing parameters of the with the influence of protruded particles on the coating deposition
water bath immersion post-treatment on the corrosion protection, process,6 and the prolonged conversion treatment improved the coat-
provided by the TCC coatings, were investigated by electrochemi- ing homogeneity on the particles and the matrix as evidenced by the
cal impedance spectroscopy (EIS) in naturally-aerated NaCl solution improved capacitances of coated region. For the coating/substrate in-
of mass fraction 3.5%. The equivalent circuit models in Figure 7 were terface (Qdl and ndl ), the coated specimens show decreased values of
used to interpret the impedance responses and the fitting results are Qdl , indicating improved capacitance properties. This was assigned
shown in Tables II, III and IV. The impedance modulus- and phase to the relatively thicker alumina layer after the prolonged conver-
angle-frequency plots in Figures 8, 9 and 10 display the electrochem- sion treatment, consistent with the general positive shift of the OCP
ical behavior of the coatings with dependence on water temperature evolution during immersion in the trivalent chromium bath.6,25
and pH variance. The open-circuit potentials prior to the EIS scans Table III shows the equivalent circuit values of TCC coatings after
were all around −600 mVSCE , consistent with the literature.22 No- treatment III (40◦ C), where the alloys after conversion treatment for
tably, the low-frequency inductive part emerged as evidenced by the 600 s displayed the best corrosion protection. The resistances of the
positive phase angles for bare alloy during full immersion in NaCl coating region (Rcoat ) revealed a smaller extent of improvement than
Journal of The Electrochemical Society, 163 (5) C131-C138 (2016) C135
HADDF
Al
Figure 7. Equivalent circuit model of (a) R(QR) for the bare alloy and (b)
R(Q(R(QR))) for the coating system on the alloys, where Re , Rcoat and Rp rep-
resented the electrolyte resistance, the resistance of coating defects or channels
and the charge-transfer resistance respectively. The time constant elements
were represented by CPE symbols.
O
after the same conversion treatment with post-treatment II. For exam-
ple, the resistances of the coating defects in the coating formed for
300 s after post-treatments II and III were 116 and 298 cm2 re-
spectively. For the charge-transfer resistance (Rp ), the coating formed
for 600 s (∼1 × 105 cm2 ) revealed an increase of ∼3 times com-
pared to such coated specimens II (∼4 × 104 cm2 ). In terms of
Cr the capacitance (Qcoat and Qdl ), the treatment III revealed a great role
in stabilizing the outer and inner coating layers as evidenced by de-
creases in those values. For example, the coatings formed for 600 s
with post-treatment III had capacitance values (Qcoat and Qdl ) of ∼7.3
× 10−6 and 4.4 × 10−6 sn /( cm2 ) respectively, while ∼8.6 × 10−6
and 6.4 × 10−6 sn /( cm2 ) for the specimen after post-treatment II.
Thus, the water immersion post-treatment III (40◦ C) for the freshly-
formed coating after injecting in the trivalent chromium bath for 600
s revealed significant improvement of the corrosion protection prop-
Zr erties.
The influence of the pH value of the warm water bath (40◦ C) on
the corrosion protection of TCC coatings formed for 600 s was also
investigated, as shown in Figure 10 with the fitting results presented
in Table IV. With increasing pH value from 5, 7 to 9, the resistances
of the coating defects (Rcoat ) and the charge-transfer resistance (Rp )
decreased, possibly attributed to the condensation effect of the basic
solution on the hydrated coatings. Interestingly, the capacitance values
of Qdl were reduced from ∼4.4 × 10−6 to 2.1 × 10−6 sn /( cm2 ),
F which means that the inner layer became more intact and stable to
maintain the larger capacitance property. By contrast, the outer layer
Figure 6. TEM/EDS mapping of the coatings formed for 300 s, followed by displayed a considerable deterioration as evidenced by the increased
the post-treatment in the water bath (pH 5, 40◦ C), where the outlined red square value of Qcoat from ∼7.4 × 10−6 to 14.3 × 10−6 sn /( cm2 ).
represented the outer layer for the elemental analyses in Table I. In summary, the higher atomic ratios of oxygen in the coat-
ing layer with respect to the combined metal components produced
more hydrated coatings after post-treatment in the warm water bath.
Table I. TEM/EDS analyses of elemental concentration by weight in the outer coating layer, where the coating was prepared in the trivalent
chromium bath for 300 s, followed by immersion post-treatment in a warm water bath (40◦ C, pH 5).
Weight % C O F S Al Cu Zr Cr
Specimen I 3.8 ± 0.6 30.9 ± 0.7 2.3 ± 0.2 0.7 ± 0.1 3.0 ± 0.2 1.1 ± 0.1 50.5 ± 0.3 7.7 ± 0.2
Specimen II 31.2 ± 7.4 35.0 ± 4.5 0.5 ± 0.1 0.6 ± 0.1 4.4 ± 0.6 0.2 ± 0.1 24.8 ± 2.6 3.0 ± 0.9
Specimen III 15.8 ± 3.8 37.3 ± 1.5 0.3 ± 0.1 0.6 ± 0.1 4.5 ± 0.4 0.5 ± 0.1 37.0 ± 1.9 4.1 ± 0.3
C136 Journal of The Electrochemical Society, 163 (5) C131-C138 (2016)
Table II. Parameters of the TCC coatings/alloy systems obtained on the base of the equivalent circuits, where the coatings were post-treated in
the cold water bath (20◦ C, 120 s). The bare alloys were named as ‘0 s’.
Re , cm2 Rcoat , cm2 Rp , cm2 Qdl , sn /( cm2 ) ndl Qcoat , sn /( cm2 ) ncoat
0s 14 (±1) - 3351 (±340) 2.8 (±0.6)E-4 0.92 (±0.02) - -
120 s 16 (±1) 45 (±3) 16325 (±390) 7.8 (±0.6)E-6 0.94 (±0.02) 1.2 (±0.1)E-5 0.81 (±0.02)
300 s 13 (±1) 116 (±3) 53826 (±306) 7.1 (±0.2)E-6 0.94 (±0.02) 7.2 (±0.1)E-6 0.88 (±0.02)
600 s 16 (±1) 153 (±2) 42086 (±322) 6.4 (±0.1)E-6 0.94 (±0.02) 8.6 (±0.1)E-6 0.88 (±0.02)
Table III. Parameters of the TCC coatings/alloy systems obtained from the fittings of the experimental EIS data according to the equivalent circuit
R(Q(R(QR))), where the coatings were post-treated in the warm water bath (40◦ C, 120 s).
Re , cm2 Rcoat , cm2 Rp , cm2 Qdl , sn /( cm2 ) ndl Qcoat , sn /( cm2 ) ncoat
120 s 13 (±1) 36 (±2) 25321 (±315) 6.0 (±0.2)E-6 0.94 (±0.02) 1.2 (±0.1)E-5 0.87 (±0.02)
300 s 14 (±1) 298 (±2) 33345 (±262) 3.4 (±0.2)E-6 0.94 (±0.02) 7.2 (±0.1)E-6 0.89 (±0.02)
600 s 14 (±1) 212 (±3) 93084 (±305) 4.4 (±0.2)E-6 0.98 (±0.01) 7.3 (±0.1)E-6 0.89 (±0.02)
Table IV. Parameters of the TCC coatings/alloy systems obtained from the fittings of the EIS data, where the coatings were formed for 600 s and
then immersed in the water bath (40◦ C) for 120 s. The effect of the pH-dependent corrosion protection property was investigated.
Re , cm2 Rcoat , cm2 Rp , cm2 Qdl , sn /( cm2 ) ndl Qcoat , sn /( cm2 ) ncoat
pH 5 14 (±1) 212 (±3) 93084 (±305) 4.4 (±0.2)E-6 0.98 (±0.01) 7.4 (±0.1)E-6 0.89 (±0.02)
pH 7 13 (±1) 112 (±2) 46420 (±312) 6.1 (±0.3)E-6 0.91 (±0.01) 7.6 (±0.3)E-6 0.88 (±0.02)
pH 9 15 (±1) 101 (±2) 25924 (±305) 2.1 (±0.1)E-6 1 (±0.1) 1.4 (±0.4)E-5 0.86 (±0.02)
10
5 Bare alloy 120 s-TCC
5
120 s-TCC 10 300 s-TCC
300 s-TCC 600 s-TCC
600 s-TCC
4
10 10
4
2
2
3
10 10
3
2 2
10 10
1 1 (a)
10 (a) 10
-2 -1 0 1 2 3 4 -2 -1 0 1 2 3 4
10 10 10 10 10 10 10 10 10 10 10 10 10 10
Log Frequency / Hz Log Frequency / Hz
-40
-20
-20
0
Bare alloy 0
20 120 s-TCC
120 s-TCC
300 s-TCC 300 s-TCC
40 20 600 s-TCC
600 s-TCC
60 40
-2 -1 0 1 2 3 4 -2 -1 0 1 2 3 4
10 10 10 10 10 10 10 10 10 10 10 10 10 10
Log Frequency / Hz Log Frequency / Hz
Figure 8. (a) Impedance modulus-frequency and (b) phase angle-frequency Figure 9. (a) Impedance modulus-frequency and (b) phase angle-frequency
plot for the bare and coated alloys during full immersion in naturally-aerated plots for the coated alloys during full immersion in naturally-aerated NaCl
NaCl solution of mass fraction 3.5%, where the coatings were formed for 120, solution of mass fraction 3.5%, where the coatings were formed for 120, 300
300 and 600 s after post-treatment II. and 600 s after post-treatment III.
Journal of The Electrochemical Society, 163 (5) C131-C138 (2016) C137
4
10 Concentration (mg/l) Zr Cr
2
Log |Z| / Ohm cm
-40 Water bath analysis.—As-prepared and used water baths (20 and
40◦ C) in post-coating treatments of the coatings after conversion treat-
ment for 300 s were analyzed by ICP-AES. Table V shows a small
-20 amount of Zr and Cr species in both used water baths, where the cold
water bath used in the post-coating treatment II produced a higher
level of Zr and Cr. This behavior may result from the physical absorp-
0 tion of Zr and Cr anions on the fresh coating surface.22 In this regard,
Skeldon et al.29 used ion beam analysis to reveal the contamination
20 or incorporation of electrolyte anions in the surface of a barrier-type
-2 -1 0 1 2 3 4
anodic film with dependence on the preferential adsorption of differ-
10 10 10 10 10 10 10 ent anions. Similarly, Zr and Cr species in the Cr(III)-based solution
Log Frequency / Hz were suggested to physically adsorb on the coating-solution interface,
and then, the post-coating treatment in the water bath can remove the
Figure 10. (a) Impedance modulus-frequency and (b) phase angle-frequency anion contaminations away from the coating-water interface into the
plots for the coated alloys during full immersion in naturally-aerated NaCl
water bath.
solution of mass fraction 3.5%, where the TCC coatings were formed for
600 s after post-treatments III (40◦ C) with dependence on pH 5, 7 and 9. Concerning the presence of Cr(VI) species in freshly-formed coat-
ing on Al,21 the possibility of Cr(VI) species in the samples present
was studied using a chemical titration test.15 The 1, 5-DPL-containing
Furthermore, the warm water bath encouraged the free fluorine dif- droplets were added into the as-prepared and used water baths (20
fusion away from the coating to decrease fluorine-containing con- and 40◦ C) and the resultant solution displayed the absence of a violet-
stituents and to stabilize the freshly-formed coating.19 In terms of purple color, suggesting that Cr species in the used water baths were
the temperature-dependent coating thickness, it correlates with the not in hexavalent form. This is in agreement with a previous report
gel-like nature of the trivalent chromium conversion coating, which of the undetectable Cr(VI) species in the freshly-formed coatings on
shrinks sufficiently at low temperature2.6 As a consequence, the coat- AA2024 alloys by Raman spectroscopy.14
ing after post-treatment in the warm water bath (40◦ C) showed a
reduction of coating defects (Rcoat ) compared to the specimens after Conclusions
treatment II (20◦ C). Furthermore, the post-treatment of immersion in
the warm water can also produce an improved inner coating layer, 1. The coating after post-treatment in the deionized water at 40◦ C
especially in the coating formed for 600 s, as evidenced by the two revealed a significant reduction of F-rich constituents and an
times increase in the charge-transfer resistances than that after cold increased extent of oxides/hydroxides. Therefore, the enhanced
water post-treatment. corrosion protection properties were investigated.
In terms of pH effects, the hydrated TCC coating was regarded as 2. The caustic water bath (pH 9) led to a considerable coating shrink-
a gel-like film with the nanosized channels being influenced by the age, deteriorating the corrosion protection property. By contrast,
effects of the pH variance in the water bath8 . The pH effect profile was the as-prepared deionized water and neutral water bath can pro-
similar to the pH-dependent silicate growth, assigned to the competi- vide appreciable thickness and better corrosion resistances.
tion between condensation, hydration and dissolution process in the 3. The coating formed for 600 s, followed by the post-treatment
aqueous solution.27,28 Considering the negligible effect of trivalent of immersion in the deionized water bath (40◦ C, pH 5) for 120
chromium coating dissolution in the deionized water, the competi- seconds revealed an optimal corrosion protection property for the
tion between hydration and condensation determines the TCC coating AA2024-T351 alloy.
thickness. By contrast, the ∼20% reduced thickness of the coatings 4. The 1, 5-DPL-containing droplets added into the used water bath
formed for 300 s was observed in the case of pH 9, while thicknesses in the post-coating treatments revealed that Cr species in the
at pH 5 and 7 were relatively stable at ∼44 nm. The condensation water bath, egressing from the coating-water interface, were only
effect after immersion in a caustic water bath (pH 9) is more signif- trivalent chromium species.
C138 Journal of The Electrochemical Society, 163 (5) C131-C138 (2016)