Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

SMP of BCS Weighing System in Turrent & Tundish at

Bloom Caster & BRC

SAFETY POINTS :

1. Ensure all PPEs are used


2. Always use proper tools for maintenance.
3. At least two persons should go together
4. Be attentive during move through Staircase/ladder. Ensure three points
contact during movement through staircase/ladder
5. Inform person in shift room before going to job for tracking purpose.
6. Always check for any leakage current, live electrical wire ,chance for
electrical
Hazard before starting jobs.

7. Ensure sufficient illumination at work place.


8. Ensure no water logging at working floors.
9. Don’t work on power line with wetted shoes
10. Look for the overhead cranes which are moving.
STEPS for Tare:

In order to suppress the tare weight,


1. Press the key [S] and, keeping it pressed, press the key [0]:
2. All LEDs are blinking; enter the number 1, then confirm pressing [Enter].
This operation is zeroing both gross and net weight.

STEPS for SPAN:

After zeroing the gross weight, place a known, significant weight (at least 50% of
the measuring range)
1. Take note of the displayed vaiue: if it is not correct, start the cali- bration
procedure pressing the key [S] and, keeping it pressed, pressing the key
[Enter]:
2. all LEDs are blinking; press the key [1], then confirm pressing [Enter]
3. Enter the value of the known weight using the numeric keys; check that the
programmed value is correct
4. Confirm the weight pressing the key [Enter]; the instrument ends the
program mode, and the correct weight is displayed;
Note:- If no weight has been programmed before pressing [Enter], the calibration
is unchanged; if a wrong weight has been entered, the calibration procedure has
to be repeated.