Professional Documents
Culture Documents
SMP of BCS WS in Bloom Caster
SMP of BCS WS in Bloom Caster
SAFETY POINTS :
After zeroing the gross weight, place a known, significant weight (at least 50% of
the measuring range)
1. Take note of the displayed vaiue: if it is not correct, start the cali- bration
procedure pressing the key [S] and, keeping it pressed, pressing the key
[Enter]:
2. all LEDs are blinking; press the key [1], then confirm pressing [Enter]
3. Enter the value of the known weight using the numeric keys; check that the
programmed value is correct
4. Confirm the weight pressing the key [Enter]; the instrument ends the
program mode, and the correct weight is displayed;
Note:- If no weight has been programmed before pressing [Enter], the calibration
is unchanged; if a wrong weight has been entered, the calibration procedure has
to be repeated.