Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Mahesh Dhivakar

From: RISVI@ERAM-INTERNATIONAL.COM <POMSAdmin@larsentoubro.com>


Sent: Thursday, March 31, 2022 2:09 PM
To: KUMARSWAMY ADIMULAM; ASHWIN GEORGE; prajeesh Mohanan; Saifuddin Mohammed; Sandeep Nalawade; Sivasankar Subbaraj; Alok Khare; Rajesh Mav; Anupam Nath; Deepak Prajapati; Arvind Shanbhogue;
Vimalkumar Gandhi; Saurabh Singh; Riyaz Pirkhan; Rajeev Kumar; Mahesh Kadam; Vijay Shinde; Pravin Dalvi; Shaker Salem Mohammed Al Khalifah; Arjun Mana
Cc: RISVI@ERAM-INTERNATIONAL.COM; admin@eram-international.com; harish@eram-international.com; lou.avegail@mesccables.com; alvin.patapat@mesccables.com; Arjun Mana; Arpana Bahl; Bhavesh Lakkad; Balasundar
Neerathilingam; MIP2Engg_mgmt; Vaibhav Thakur; MIPPKG-2 SCM OFFSHORE; MIP PKG-2 QA OFFSHORE; Vipul Jamdade; Deepak Prajapati; Harikrishnan B; Rahul More; Mahesh Dhivakar; Omkar Apte; Sameer Vardam;
Shweta Bhise; Parijat Dasgupta; Suchit Parab; Arjun Mana; Kunal Kale; ANSAR SHERIFF HUSSAIN SHERIFF
Subject: Inspection Carried out for MIPPKG2/NOI/1800 R0 by LIA ERAM for Instrument Cable (PO 7500092851) by MIDDLE EAST SPECIALIZED CABLES CO..

Dear Sir/Madam,

Please note that we have carried out inspection Notification No. MIPPKG2/NOI/1800 for Instrument Cable of MIDDLE EAST SPECIALIZED CABLES CO..

Inspection date From 27-03-2022 10:00:00 To 29-03-2022 16:00:00


PO Sr. No. ITP Sr. No. Stage Description
1-39 1B Material Test report for Conductor, Insulation, Jacket, shield , armour etc.
1-39 2A UL certificate for similar type of cable
1-39 2B Physical properties test for aged & unaged samples
1-39 2C a. Cold bend test on insulation b. Cold bend test on complete piece of cable
1-39 2D Vertical Tray Flame Retardance
1-39 2E Heat Shock test on Insulation & jacket
1-39 2F Flexibility & deformation test
1-39 2G Durability of indelible-Ink printing
1-39 2H Fire proof test
1-39 2I Hydrocarbon Oil Resistant test
1-39 2J Crushing and Water Absorption/Direct Burial, Moisture and Abrasion Resistance
1-39 2K Insulation Resistance Test at 600F
1-39 2L Sun light resistance
1-39 2M Smoke released (Emission) test for LS Property.
1-39 2N Halogen gas emission test for ZH Property.
1-39 2O PH & Conductivity test for ZH Property.
1-39 3A TO 3C Review of internal physical routine inspection report for 100% offered cables
1-39 4A Review of internal electrical routine inspection report for 100% offered cables
1-39 5A Construction, Dimension, Color, Identification, Cable Marking Cable Reel Marking, Drum length etc.
1-39 5B Unwinding the full drum, leaving 5-10mts for convenience in re-winding(2Drums Per Lot )
1-39 5C Visual check, End cap (both end) verification, Drum marking/labeling
1-39 5D Final test on offered cables as per approved ITP/FAT Procedure
1-39 6A Product Test Certificate & Certificate of Compliance to Purchase Order, Approved Specification / Datasheets
1-39 6B Saudi Aramco Inspection Checklist (SAIC) Verification
1-39 6D Packing and Preservation checks
1-39 6E Inspection Release Note for shipping
1-39 6F Manufacturer Record book

1
To view, kindly access below URL.

Inspection Call URL : Click Here

Thanks & Regards,

MOHAMMED RISVI
Saudi Arebia
For any Help in Quest system access, Kindly Contact to ProeTrack Support on (022-6705 5614/5617) or Proetracksupport@larsentoubro.com

Disclaimer:"This email and any files transmitted with it are intended solely for the use of the addressee(s) only and may contain confidential and/or privileged information. If you are not the addressee, then this message is not
intended for you and be advised that you have received this email in error and that any use, dissemination, forwarding, printing or copying of this email is strictly prohibited. In such case please notify the sender and delete this
email and any attachments with it from your system immediately. Receipt of this email by you shall not give rise to any liability on the part of L&T Hydrocarbon Engineering"

You might also like