INDEX

1. PRODUCT CATALOGUE 3

2. PREVIOUS APPROVAL 79

3. WARRANTY CERTIFICATE 99

4. COUNTRY OF ORIGIN 101

5. MATERIALS LIST 104

6. DATA SHEET 106


Farenhyt Sales and Application Training
1
1
Honeywell Farenhyt product line
• Silent Knight History

• Farenhyt Positioning

• Farenhyt Key Markets and Verticals

• Farenhyt Global References

• Next Generation of Farenhyt Addressable FACPs

• Farenhyt SLC Devices and Detectors

• Farenhyt SBUS Devices

• Farenhyt Emergency Communication Systems & FFT

• Graphical Monitoring Software

• Farenhyt Key features and Benefits

• Farenhyt Tools and Resources


© 2016 by Honeywell International Inc. All rights reserved.
Company Internal
2
2
SILENT KNIGHT History

3nd Largest
brand in USA

First analog / First integrated


First UL listed addressable FACP Bought by addressable FACP
Founded DACT for fire with built-in DACT Pittway with ECS
1966 1985 1997 1999 2013

First digital alarm First power Farenhyt FAS series Bought by Q1’2018
communicator expander for launched 1998 Honeywell Branding Change and
and receiver 1970 hungry new ADA 2000 Next Generation of Product
notification appliances
1993

© 2016 by Honeywell International Inc. All rights reserved.


Company Internal
SK-Farenhyt Branding Change

© 2016 by Honeywell International Inc. All rights reserved.


Company Internal
Farenhyt Key Markets and Verticals

Commercial Offices Malls Education

Healthcare Facilities Hospitality Residential Buildings

© 2016 by Honeywell International Inc. All rights reserved.


5
Global Prestigious References

• General Motors • Home Depot

• Macy’s • Wyndham Hotels

• Ford Motor Company • Sony

• Eastman Kodak • Sears

• Disney Studios
• Bausch & Lomb

• Federal Reserve Bank


• University of Georgia

• Linens ‘n’ Things


• University of Idaho
• Atlanta Civic Center

© 2016 by Honeywell International Inc. All rights reserved.


Manufacturing Location – Panels/ Acc’s – Northford, USA

© 2016 by Honeywell International Inc. All rights reserved.


Manufacturing Location – Detectors/Devices – Juarez, Mexico

Detectors, modules, Audio Visual devices, Pull stations

© 2016 by Honeywell International Inc. All rights reserved.


HONEYWELL - CONFIDENTIAL
Next Generation Farenhyt Addressable Fire Panel Product Line up

Fire Alarm Controls Fire Alarm Controls w/ECS

IFP-2100B (Black) IFP-2100ECSB (Black)


IFP-2100 (Red) IFP-2100ECS (Red)

IFP-300B (Black) IFP-300ECSB (Black)


IFP-300 (Red) IFP-300ECS (Red)

IFP-75B (Black)
IFP-75 (Red)

© 2016 by Honeywell International Inc. All rights reserved.


9

Addressable Fire Alarm Systems

© 2016 by Honeywell International Inc. All rights reserved.


IFP-2100 / IFP-2100B- Addressable Fire Alarm Control Panel
• Panel supports up to 2100 Points (159 sensors/159 devices per loop). All points can be sensors

• Additional SLC can be added by installing 6815 SLC expanders

• 5815RMK Red Remote Mounting Cabinet


- can mount 2 x 6815 SLC Expanders

• Available in Red or Black cabinet

• 8 Flexput™ I/O circuits (3 Amps per Circuit) and can be programmed


individually as
- Notification circuits / Auxiliary power circuit / Initiation Circuit

• 4 Line x 40 Character LCD display

• Two SBUSs. Support SWIFT Wireless

• Can be networked up to 32 panels via SK-NIC (network card).

• Support copper network, Single mode, Multimode fiber connection option

• 9A Power Supply
© 2016 by Honeywell International Inc. All rights reserved.
RFP-2100 / RFP-2100B
• Panel supports up to 2100 Points (159 sensors/159 devices per loop). All points can be sensors

• Additional SLC can be added by 6815 cards

• Available in Red or Black cabinet

• Two SBUSs. Support SWIFT Wireless

• Can be networked up to 32 panels via SK-NIC (network card)

• Support copper network, Single mode, Multimode fiber connection option

• 8 Flexput™ I/O circuits (3 Amps per Circuit) and can be programmed


individually as
- Notification circuits / Auxiliary power circuit / Initiation Circuit

• 9A Power Supply

© 2016 by Honeywell International Inc. All rights reserved.


SBUS Application Example – 5 Floor Building Example
SBUS

SLC

SLC Expander

Repeater Panel

Example ( All 2100 points can be


sensors)
- 1 x IFP-2100 + 2 x 6815s
▪ 2 SLC
- 5 x 5815RMK (2 x 6815s each)
▪ 10 x SLCs
- 1 x 5815RMK (1 x 6815s each)
▪ 1 x SLCs
- 13 SLCs x 159 sensors = 2067
- 2100 sensors max

Note: 6815 expanders donot have predefined device count limit (63 Total SBUS Devices).Limit
© 2016 by Honeywell International Inc. All rights reserved.
IFP-2100 / IFP-2100B / RFP-2100 / RFP-2100B Overview

Key Features

Panel IFP-2100 RFP-2100


IFP-2100B RFP-2100B
Addressable SLC Points 2100 2100

IDP Protocol 2100 Mixed 2100 Mixed Up to 2100 total


points per
Power Supply 9A 9A IFP-2100!
# of NACs 8 (FlexPuts) 8 (FlexPuts)

# of SBUS 2 2

SBUS Backwards Y Y
Compatibility
Display 160-Char (4x40) N/A
Char Display

Company Internal Honeywell Confidential © 2017 by Honeywell International Inc. All rights reserved.
IFP-2100ECS / IFP-2100ECSB- Addressable Fire Alarm Control Panel and
Emergency Communication System
• Panel supports up to 2100 Points (159 sensors/159 devices per loop)
• Additional SLC can be added by 6815 cards
• Available in Red or Black cabinet
• 4 Line x 40 Character LCD display
• Two SBUSs
• Can be networked up to 32 panels via SK-NIC (network card)
• Support copper network, Single mode, Multimode fiber
connection option
• Eight FlexPuts
• 9A Power Supply

Emergency Communication System


• Support up to 16 * ECS-50W or ECS-DUAL50W or ECS-INT50W Addressable Amplifiers for a Max of
2000W per system
• Configure the 8 ECS buttons with 15 recordable one minute messages
• 128 audio circuits can be mapped with 64 Audio Switches
• Support up to 15 ECS-RPU (Remote Paging Unit)s or ECS-LOC (Local Operator Console) in
combination. ECS-RCU meets the UL requirements of a LOC
© 2016 by Honeywell International Inc. All rights reserved.
IFP-2100ECS / IFP-2100ECSB Overview

Key Features

IFP-2100ECS
Panel
IFP-2100ECSB
Addressable SLC Points 2100
# of Amplifiers 16

Total Amp Power 2000W

# of Speaker Circuits 128

# of Mapped Audio Switches 64


# of Recordable Messages 15
# of ECS Buttons 8
# of ECS-RPU 15
# of ECS-LOC 15
ECS-RPU
ECS-DUAL50W
Listed for Low Frequency (520Hz)
ECS-INT50W Only
Company Internal Honeywell Confidential © 2017 by Honeywell International Inc. All rights reserved.
Emergency Communication System with Fire Alarm Control Panel Schematic

© 2016 by Honeywell International Inc. All rights reserved.


17

Networking

© 2016 by Honeywell International Inc. All rights reserved.


IFP-2100 Networking
• Up to 32 IFP-2100 & RPS-2100 panels can be networked in any combination
SK-NIC
Mounts inside the panel
*External mounting requires SK-NIC-KIT and this kit
includes the network card when ordered

Copper Cable

SK-NIC SK-NIC SK-NIC SK-NIC

Building 1 Building 2

Twisted Pair Copper Wire - must use the SK-NIC to provide up to 3000 feet of separation.

© 2016 by Honeywell International Inc. All rights reserved.


IFP-2100 Networking
• Up to 32 IFP-2100 & RPS-2100 panels can be networked in any combination

Single Mode Fiber


SK-FSL SK-FSL

Building 1 Building 2

Fiber Optic Single Mode - must use the SK-NIC and SK-FSL for up to 30dB loss of signal separation. SKFSL
connects to the network using 9/125 micron single-mode fiber

© 2016 by Honeywell International Inc. All rights reserved.


IFP-2100 Networking
• Up to 32 IFP-2100 & RPS-2100 panels can be networked in any combination

Multi Mode Fiber


SK-FML SK-FML

Building 1 Building 2

Fiber Optic Multi-Mode - must use the SK-NIC and SK-FML for up to 8dB loss of signal separation. SKFML
connects to the network using 62.5/125 micron multi-mode fiber

© 2016 by Honeywell International Inc. All rights reserved.


IFP-2100 Networking
• Hybrid Network – mix copper and fiber (single & multi mode) media as per project specification

Single Mode Fiber


Building 1 Max 30db loss using 9/125 fiber Building 2

Copper Cable Copper Cable


Max 3000 feet Max 3000 feet

Multi Mode Fiber


Building 4 Building 3
Max 8db loss using 62.5/125 fiber

© 2016 by Honeywell International Inc. All rights reserved.


22

Signaling Line Circuit - SLC

© 2016 by Honeywell International Inc. All rights reserved.


SLC Wiring Requirements – Page 113 IFP-2100ECS Manual

© 2016 by Honeywell International Inc. All rights reserved.


IDP Detector Part Numbers
• IDP-ACCLIMATE - Addressable Multi Photoelectric Smoke W Thermal (Base Not Included)
• IDP-PHOTO-T - Addressable Photoelectric Smoke Detect. W/ Thermal (Base Not Included)
• IDP-BEAM - Addressable Beam Smoke Detector
• IDP-BEAM-T - Addressable Beam Smoke Detector with Test Feature
• IDP-FIRE-CO - Addressable Fire & Co Combination Detector (Base Not Included)
• IDP-HEAT - Addressable Thermal Detector Fixed Temp 135F (57 degrees Celsius) (Base Not Included)
• IDP-HEAT-HT - Addressable Variable Detector High Temp 135F – 190F (57 – 88 degrees Celsius)
• IDP-HEAT-ROR - Addressable Thermal Detector (Rate of Rise) 15 degree F/Min (9 degree C/Min)
• IDP-PHOTO - Addressable Photoelectric Smoke Detector. (Base Not Included)
• IDP-PHOTOR - Intelligent Photoelectric Smoke Detector – Remote Test Capable (DNR)

Note: Rotary Address Switches for Addressing


© 2016 by Honeywell International Inc. All rights reserved.
IDP Base and Accessory Options
• B501 - Intelligent 4 Inch Base (Made in US)
• B501. - Intelligent 4 Inch detector base, without flange (Made in India )
• B210LP - 6 Inch Base
• B210LPBP – Bulk pack of 10 x B210LP bases
• B224BI - IDP Isolator Base
• B224RB - IDP Relay Base
• B200S - Intelligent Sounder Base High/low Volume Output W/ansi Temporal 3 Or Temporal 4, Continuous, March Or
Custom Tone
• B200S-LF - Intelligent Low Frequency Sounder Base W/ansi Temporal 3 Or Temporal 4, Continuous, March Or Custom
Tone
• B501BP - Bulk pack of 10 x B501 bases
• BCK-200B - Black detector cover conversion kit (Bulk pack qty. 10)
• DNR - InnovairFlex intelligent duct detector, non-relay, does not include head
• DNRW - InnovairFlex duct detector, non-relay, does not include head, watertight

© 2016 by Honeywell International Inc. All rights reserved.


IDP Module Part Numbers
• IDP-CONTROL - Addressable Supervised Control Module
• IDP-RELAY - Addressable Relay Module W/ 2 Isolated Sets Of Form C Contacts
• IDP-RELAYMON-2 - Dual Input/dual Output Module
• IDP-MINIMON - Addressable Mini Monitor Module, Supervised, Single Contact
• IDP-MONITOR - Addressable Monitor Module, Supervised, Single Contact
• IDP-MONITOR-2 - Addressable Monitor Module, Supervised W/ 2 Initiating Circuits
• IDP-PULL-DA - Addressable Pull Station, Dual Action, Key Reset
• IDP-PULL-SA - Addressable Pull Station, Single Action, Key Reset
• IDP-ZONE - Addressable 2-wire Zone Interface Module
• IDP-ISO - Isolator Module
• SMB500 - 4” Square Surface Mount Electrical Box for use with IDP modules

© 2016 by Honeywell International Inc. All rights reserved.


IDP Module Part Numbers
• IDP-CONTROL-6 - Addressable 6 Circuit Supervised Control Module
• IDP-MONITOR-10 - Addressable Monitor Module, Supervised, 10 Points
• IDP-RELAY-6 - Addressable Relay Module W/ 6 Form C Relays
• IDP-ZONE-6 - Addressable 2-wire Zone Interface W/ 6-zone Inputs
• ISO-6 Six - Position Line Isolator Mod. Isolates Short Circuits on SLC Loop

IDP-ACB IDP-MONITOR-10 IDP-CONTROL-6 IDP-RELAY-6 IDP-ZONE-6 ISO-6

© 2016 by Honeywell International Inc. All rights reserved.


SWIFT Wireless 2.0 (Smart Wireless Integrated Fire Technology)
WIDP-HEAT-ROR
WIDP-ACCLIMATE

▪ Compatible with SWIFT 2.0 wireless offering


▪ Frequency Range (902MHz – 928MHz)
▪ Four gateways / 49 wireless devices each
▪ Total of 196 Devices WIDP-PHOTO

▪ Each wireless devices acts like a repeater


▪ 4x CR123A Batteries required per device
▪ Battery UL listed for 2 year of minimum operation
WIDP-WGI
MESH Network WIDP-HEAT
Gateway is wired on the SLC loop

WIDP-PULL-DA
WIDP-PULL-SA

WIDP-MONITOR WIDP-RELAY

© 2016 by Honeywell International Inc. All rights reserved.


SWIFT Wireless 2.0 WIDP-ACCLIMATE
WIDP-HEAT-ROR

In order to determine to signal strength and


system viability an audit of the site needs to be
conducted using the W-USB key, SWIFT Tools
and some field devices. WIDP-PHOTO

Your laptop will act as the gateway and will test


the signal strength to the devices to ensure the
system will work 100%
MESH Network WIDP-HEAT
SWIFT Wireless Videos
https://www.youtube.com/watch?v=iM7tDYZnfg0&index=4&list=PLD98
FZk95VNJS5rlHQU_YU5IXvwE91i0r
https://www.youtube.com/watch?v=9fBhaCiub6A&list=PLD98FZk95VNJ
S5rlHQU_YU5IXvwE91i0r&index=7
https://www.youtube.com/watch?v=2PZstvX68b4&index=8&list=PLD98
FZk95VNJS5rlHQU_YU5IXvwE91i0r
WIDP-PULL-DA
https://www.youtube.com/watch?v=HqXY48iHRZs&index=9&list=PLD9
WIDP-PULL-SA
8FZk95VNJS5rlHQU_YU5IXvwE91i0r
https://www.youtube.com/watch?v=D-
Jd5T_UYmI&index=10&list=PLD98FZk95VNJS5rlHQU_YU5IXvwE91i0r
https://www.youtube.com/watch?v=V68jmTIQSDU&list=PLD98FZk95V
NJS5rlHQU_YU5IXvwE91i0r&index=11
WIDP-MONITOR WIDP-RELAY
…and many more via our YouTube channel, have a look!
© 2016 by Honeywell International Inc. All rights reserved.
SWIFT Wireless 2.0
WIDP-PULL-DA
WIDP-PULL-SA
WIDP-ACCLIMATE

▪ Conventional Sounder Solution

MESH Network

WIDP-WGI
24VDC
Gateway is wired on the SLC loop
Conventional Sounder WIDP-RELAY

PSU Power Fault Monitor

WIDP-MONITOR Conventional Power Supply

© 2016 by Honeywell International Inc. All rights reserved.


IDP-FIRE-CO Addressable Combination Fire & CO Detector
• CO is released through the incomplete burning of various fuels, CO is a
colorless, odorless and deadly gas that is virtually impossible to detect
with the Human Senses

• Provides life safety detection for fire and CO with one device
- Uses Photoelectric, Heat, Light/Flame and CO to detect fire and significantly
reduce nuisance alarms
- Uses electrochemical sensor to detect carbon monoxide as a separate alarm

• Better Together
- Saves installation time and money
- Improves room aesthetics

• Separates audible signal for fire or CO alarm when used with


B200S/B200S-LP (Intelligent sounder base)

© 2016 by Honeywell International Inc. All rights reserved.


Solutions for CO Applications - OLD
Mini-horn for General Evacuation Smoke detector on sounder base Carbon Monoxide detector

© 2016 by Honeywell International Inc. All rights reserved.


Solutions for CO Applications - NEW
IDP-FIRE-CO W/B200S

© 2016 by Honeywell International Inc. All rights reserved.


Three Low Frequency Choices For a Complete Solution
• Low Frequency Sounders

• Low Frequency Tones through Speaker

• Low Frequency Sounder Base

© 2016 by Honeywell International Inc. All rights reserved.


Low Frequency Sounder Specifications
• Model number: HR-LF , HW-LF

• Operates on NAC circuit (12 or 24 VDC/FWR)

• Dual Listed-Wall or Ceiling

• Universal Mounting Plate

• Plug In Design

• Listed to UL, FM and CSFM

© 2016 by Honeywell International Inc. All rights reserved.


Low Frequency Sounder Strobe Specifications

• Model number: P2RH-LF , P2WH-LF

• Operates on NAC circuit (24 VDC/FWR)

• High CD: 135,150,177 and 185

• Dual Listed- Wall or Ceiling

• Universal Mounting Plate

• Plug In Design

• Listed to UL, FM and CSFM


© 2016 by Honeywell International Inc. All rights reserved.
Design Considerations
• Current Draw Comparison
Model # 135 150 177 185
P2RH Temporal High 245mA 259mA 290mA 297mA
P2RH Temporal Medium 235mA 253mA 288mA 297mA
P2RH Temporal Low 232mA 251mA 282mA 292mA

P2RH-LF Temporal 3 277mA 292mA 325mA 344mA

• Low Frequency Sounders Use More Energy


- Generate square wave at 520Hz
- Uses NAC to power self contained circuit that drives speaker (NOT Piezo)

• Will Require More NAC Power Supplies in Design

© 2016 by Honeywell International Inc. All rights reserved.


Low Frequency Sounder Base

• Single Station / Multi-Station

- B200S-LF/B200SR-LF Low Frequency Sounder

- Current Draw Comparison

▪ B200S Aux Power Alarm Current Draw 35mA


▪ B200S-LF Aux Power Alarm Current Draw 140mA

▪ B200SR Aux Power Alarm Current Draw 35mA


▪ B200SR-LF Aux Power Alarm Current Draw 125mA

© 2016 by Honeywell International Inc. All rights reserved.


SBUS Communication Bus

© 2016 by Honeywell International Inc. All rights reserved.


SBUS
• Serial RS-485 Communication Bus

• Distributed Intelligence is a differentiator

• 4-Conductors used for Communication between FACP and accessories


- Two for power
- Two for data in and out

• Allows accessories to be distributed and placed where they are needed

• Each device is addressed with dip switches for supervision

• SBUS is power and distance limited

© 2016 by Honeywell International Inc. All rights reserved.


SBUS Wiring Distance
Wiring Distance SBUS Modules to FACP
Total worst case Current Draw
22 Gauge 18 Gauge 16 Gauge 14 Gauge
(amps)

0.100 1852 ft 4688 ft 6000 ft 6000 ft

0.200 926 2344 3731 5906

0.300 617 1563 2488 3937

0.400 463 1172 1866 2953

0.500 370 938 1493 2362

0.600 309 781 1244 1969

0.700 265 670 1066 1687

0.800 231 586 933 1476

0.900 206 521 829 1312

1.00 185 469 746 1181

* Always use the SBUS device calculator to confirm current draw and cable distance

© 2016 by Honeywell International Inc. All rights reserved.


SBUS Device Current Draw – Page 48 IFP-2100ECS Manual

* Always use the SBUS device calculator to confirm current draw and cable distance

© 2016 by Honeywell International Inc. All rights reserved.


SBUS Devices
6815 SLC Expander
• Used to expand SLC device capacity (159 Detectors & 159
Modules per SLC)

• Extend the SLC expander outside the panel in field by


installing in below mounting options .Connects to the
SBUS and communicates via RS485

• Mounting Options
- RPS-1000 Cabinet can mount 2 x 6815 SLC Expander

- 5815RMK Red Remote Mounting Cabinet – can mount 2 x


6815 SLC Expanders
SBUS Current Draw 0.78 amps
- 5815RMKB Black Remote Mounting Cabinet – can mount 2 x
6815 SLC Expanders

- SK-NIC-KIT Remote Mounting Kit Cabinet – can mount 2 x


6815 SLC Expanders

© 2016 by Honeywell International Inc. All rights reserved.


SBUS Devices
5824 Serial / Parallel Gateway Module
• Allows connection to a standard dot matrix track printer

• Also use RS-232 port to connect to PC which runs IFP-NET-3


(graphical monitoring software)

• Or use the RS-232 port to connect to connect to IP Gateway to


SBUS Current Draw 0.40 amps connect to IFP-NET-3

Parallel

RS-232

© 2016 by Honeywell International Inc. All rights reserved.


SBUS Devices 5880 LED / IO Module

• Traditional LED Mimic Panel


• Drives 40 programmable open collector LED outputs
- Ex: Zone 1 activates, Light up LED 1
• Provides 8 supervised dry contact inputs for system or
alarm monitoring functions
- Normally open, conventional inputs
- Conventional Pull stations
SBUS Current Draw 0.250 amps - Monitor Waterflow
- Monitor Tamper

5880

© 2016 by Honeywell International Inc. All rights reserved.


5883 Relay Interface Board
• Does not connect to the SBUS

• 10 general purpose Form C relays used to control


any device that requires a dry contact closure

• The interface board is activated by an open collector


input from a controlling device such as a 5880 LED
driver module. Instead of activating LED output, it
can activate these relays

• Up to four 5883s can be connected to the 5880 LED


driver module

SBUS Current Draw 0.220 amps


• Relays rated at 5.0A @ 30 VDC or 250 VAC resistive

© 2016 by Honeywell International Inc. All rights reserved.


SBUS Devices
5865-3 LED Annunciator
• Connects to the SBUS
• 15 Zones (1 fire and 1 fault per zone)
• 15 Fire RED LED on left
• 15 Fault YELLOW LED on right
• Up to eight 5865s can be used on one panel

SBUS Current Draw 0.200 amps

5865-4 LED Annunciator


• Connects to the SBUS
• 15 Zones (1 fire and 1 fault per zone)
• 15 Fire LED RED LED on left
• 15 Fault LED YELLOW LED on right
• Reset and Silence input switches that are activated with fire
fighter key
• Up to eight 5865s can be used on one panel

© 2016 by Honeywell International Inc. All rights reserved.


RA-1000 / RA-1000R Remote Annunciator

• 80-character backlit LCD display (4 lines with 20


characters each)

• Larger keypad buttons for system reset and silence

• Five status LEDs for alarms, supervisory, trouble,


silence and AC power indications
SBUS Current Draw 0.120 amps
• Activated by user code or fire fighter key

• Up to 31 RA-1000 s per system for IFP-2100 panels

• Available in Red or Gray color

© 2016 by Honeywell International Inc. All rights reserved.


RA-2000 / IFP-2000GRAY Remote Annunciator

• 160 Character Display ((4 lines with 40 characters


each)

• 4 programmable function keys which can be


customized to do many functions
▪ Example – Press Key to activate outputs, disable
specific points during testing or maintenance

• Larger keypad buttons for system reset, silence, Event


SBUS Current Draw 0.120 amps acknowledge and Fire drill

• Flush mountable

• Available in Red or Gray color

© 2016 by Honeywell International Inc. All rights reserved.


SK-F485C SBUS Fiber Converter

• The SK-F485C converts the SBUS (RS-485) wire data


to fiber and back to SBUS wire data for extending the
SBUS over a long distance

• Eliminates the risk of lightning damage caused by


running copper wire between buildings

• The SK-F485C does not take up an SBUS address.

• Cannot be used for VBUS


SBUS Current Draw 0.125 amps

© 2016 by Honeywell International Inc. All rights reserved.


SK-F485C SBUS Fiber Converter (Application Example)

Main Building Warehouse

IFP-2100 RPS-1000

6815XL

Fiber SK-F485C
SK-F485C

© 2016 by Honeywell International Inc. All rights reserved.


5496 Intelligent Power Supply
• Support 6 amps of 24 VDC power with 4 notification circuits,
rated at 3 Amps each

• Built-in synchronization for appliances from Gentex, Faraday,


AMSECO, System Sensor, and Wheelock

• 4 programmable circuits
- NAC (Notification Appliance Circuit)
- Constant Power
- Resettable Power
- Door Holder Power
- Sounder Base Power

• Each circuit can be independently mapped, controlled and


supervised so in case of trouble it will indicate to Main FACP

• Each power supply works independently to sync its outputs

• Battery Charging Capacity: 7.0 – 35.0 AH

© 2016 by Honeywell International Inc. All rights reserved.


RPS-1000 Intelligent Power Supply
• Support 6 amps of 24 VDC power with 6 Flexputs™ circuits, rated at
3 amps each

• 6 programmable Flexputs™ rated at 3A each, total load of 6A


- NAC (Notification Appliance Circuit)
- Constant Power
- Resettable Power
- Door Holder Power
- Sounder Base Power
- Conventional Input

• Each circuit can be independently mapped

• 2 x Form C Programmable Relays Rated @ 2.5A 24VDC

• Distributed power allows shorter NAC wiring runs

• Each power supply works independently to sync its outputs

• SBUS Repeater (1 Amps SBUS)

• Max Battery Charging 35Ah (internal 2 x 18Ah batteries) Bigger


batteries externally mounted (RBB cabinet)

© 2016 by Honeywell International Inc. All rights reserved.


RPS-1000 Intelligent Power Supply

• SBUS repeater reconditions SBUS for extended distances

6000 ft

6000 ft

© 2016 by Honeywell International Inc. All rights reserved.


55

Emergency Communications

© 2016 by Honeywell International Inc. All rights reserved.


IFP-2100ECS / IFP-2100ECSB- Addressable Fire Alarm Control
Panel and Emergency Communication System
• Panel supports up to 2100 Points (159 Detectors &159 Modules per loop)
• Additional SLC (Loops) can be added by 6815 cards
• Available in Red or Black
• 4 Line x 40 Character LCD display
• Two SBUSs
• Can be networked up to 32 panels via SK-NIC (network card)
- Copper Media, Fiber Optic Media (Single and Multimode)
• 9A Power Supply
• Eight Flexputs

Emergency Communication System


• Support up to 16 * ECS-50W or ECS-DUAL50W or ECS-INT50W Addressable Amplifiers for a Max of
2000W per system
• 15 recordable one-minute messages that can be mapped to eight ECS buttons
• Support up to 15 ECS-RCUs or ECS-LOC in combination. ECS-RCU meets the UL requirements of a
LOC (Local Operator Console)

© 2016 by Honeywell International Inc. All rights reserved.


Amplifiers – ECS-50W • 50 Watts Total

• 4 speaker circuits out of the box rated at 50 watts each expandable to 8


using the ECS-CE4

• Selectable for 25 or 70.7 VRMS operation

• Can be mounted upto 6000Ft away from ECS Series panel and can be
conveniently located near the area of protection to reduce wiring
demands
ECS FACP ECS-50W
• Six wire connection to ECS System: Two wires for the voice bus and
SBUS
(4-conductor)
Four wires for the SBUS connections

• Has own power supply and battery backup

VBUS
• Surface or Flush Mounted
(2-conductor
shielded)
• Available in Red or Black cabinet

4 more circuits using ECS-CE4 circuit expander


* Mounts inside the amplifier

© 2016 by Honeywell International Inc. All rights reserved.


ECS Amplifiers - ECS-DUAL50W
• 50/100 Watt Dual Channel Amplifier

• 8 built-in speaker circuits rated at 50W each


• Can be 8 class A or 8 class B

• ECS-CE4 - CANNOT be used to expand circuits

• UL listed to produce 520Hz tone when used with compatible


ECS FACP ECS-DUAL50W speakers
SBUS
(4-conductor) • Selectable for 25 or 70.7 VRMS operation

• Can be mounted upto 6000Ft away from ECS Series panel and
can be conveniently located near the area of protection to
VBUS
reduce wiring demands
(2-conductor
shielded)
• Six wire connection to ECS System: Two wires for the voice
bus and Four wires for the SBUS connections

• Has own power supply and battery backup

• Surface or Flush Mounted

• Available in Red or Black cabinet


© 2016 by Honeywell International Inc. All rights reserved.
ECS Amplifiers - ECS-DUAL50W
• Amplifier can be configured as follows:
- 100 watts total
- 50 watts with 50 watts backup
- 100 watts with 50 watts backup using ECS-50WBU
- Dual channel using 50 watts for each channel with 50 watts
backup using the ECS-50WBU (IFP-2100 ONLY)

ECS FACP ECS-DUAL50W ECS-50W ECS-50W

SBUS
(4-conductor)

Distributed Power!

VBUS
(2-conductor
shielded)

© 2016 by Honeywell International Inc. All rights reserved.


ECS Amplifiers - ECS-INT50W / EVS-INT50W
• 50 Watts Total

• One speaker circuit rated at 50 watts

• UL listed to produce 520 Hz low frequency tone

• Can be mounted inside the new IFP2100ECS


using the ECS-AMPMT mounting kit (sold
separately) *

*if installed then you lose the space to install two


6815 SLC Expanders

© 2016 by Honeywell International Inc. All rights reserved.


Distributed Intelligence = Design Flexibility
IFP-2100ECS 5880
w/ECS options
SBUS

ECS-50W
VBUS

SLC 5895XL

ECS-CE4 6 Flexputs
ECS-125W

5496

ECS-CE4
4 NACs
ECS-LOC

5860
8 Flexputs

6815XL
SLC

© 2016 by Honeywell International Inc. All rights reserved.


Emergency Communication Modules
ECS-LOC

- Local Operating Console


- 4 x 40 Annunciator
- Supervised Microphone
- 8 Emergency Message Buttons (15 Recordable
Messages)
- Four Programmable Function Keys
- On-Board Supervised Microphone
- 64 Mappable Speaker circuits
- 40 Mappable audio switches
- Up to 15 in combination with ECS-LOCs for IFP-
2100ECS panels
- Connects to control panel via 4-wire SBUS and 2-wire
VBUS
- Available in Red or Black Color

© 2016 by Honeywell International Inc. All rights reserved.


Company Internal
Emergency Communication Modules
ECS-LOC2100

- Local Operating Console


- 4 x 40 Annunciator
- Supervised Microphone
- 8 Emergency Message Buttons (15 Recordable Messages)
- Four Programmable Function Keys
- On-Board Supervised Microphone
- 128 Mappable Speaker circuits
- 64 Mappable audio switches
- Up to 15 in combination with ECS-LOCs for IFP-2100ECS panels
- Connects to control panel via 4-wire SBUS and 2-wire VBUS
- Available in Red or Black Color

© 2016 by Honeywell International Inc. All rights reserved.


Company Internal
Emergency Communication Modules
ECS-RPU

- Remote Paging Unit


- Supervised Microphone
- 8 Emergency Message Buttons
- 16 Mappable Audio Switches
- Up to 15 in combination with ECS-LOCs for IFP-2100ECS panels
- Connects to control panel via 4-wire SBUS and 2-wire VBUS

ECS-RPU with RA-2000

The RA-2000 have the same height and flush mount depth as
the ECS-RPU so if the installation requires a fully functioning
LOC with annunciation the RA-2000 can be installed right next
RA-2000 ECS-RCU
to the ECS-RPU for a sleek installation which meets UL requirements
for LOC
© 2016 by Honeywell International Inc. All rights reserved.
65

IFP-Net-3 (Graphical Monitoring Workstation)

Company Internal

© 2016 by Honeywell International Inc. All rights reserved.


IFP-Net-3 (Graphical Monitoring Workstation)
• IFP-Net is a Microsoft® Windows® based graphic user interface linking selected fire alarm control
panels together to a PC to easily monitor them.
• The PC operator would receive real-time information about a system with details showing right
where the event is occurring

Features and Benefits


• The IFP-Net-3 used to monitor upto 200 Honeywell Farenhyt Fire Alarm Panels over IP network
• Auto navigation automatically locates and zooms to the device related to an alarm or event based
on the priority of the event
• Dynamically generated sizable key map
• History Manager records operator, event, and response (with time and date stamp) to disk
• Floor plans can be zoomed in and out to any level

Ordering Parts
• IFP-NET-3: Software and key (a key is required on each PC in system)

• IFPN-GW-KIT: Installation packages includes Gateway interface, Cabinet, and


5824 Serial/ Parallel printer interface

© 2016 by Honeywell International Inc. All rights reserved.


67

FFT Fire Fighter Telephone System

© 2016 by Honeywell International Inc. All rights reserved.


Fire Fighter Telephone System
• The IFP-FFT Fire Fighter Telephone System provides supervision, annunciation,
and control for local and remote telephone handsets

• IFP-FFT Fire Fighter Telephone system provides control and annunciation to 72


remote telephone jacks

• A maximum of 10 Fire Fighter Remote Handsets active at the same time to


communicate over the telephone circuit connected to the IFP-FFT

• System Status LEDs

• Supports two FFT-24 zone expanders

© 2016 by Honeywell International Inc. All rights reserved.


Company Internal
Fire Fighter Telephone System – Architecture

IFT-FFT

© 2016 by Honeywell International Inc. All rights reserved.


Fire Fighter Telephone System - Wiring

Maximum wiring resistance 40ohms

© 2016 by Honeywell International Inc. All rights reserved.


Company Internal
71

Farenhyt Key Features and Benefits

© 2016 by Honeywell International Inc. All rights reserved.


Farenhyt Key Features and Benefits
Key Features Benefits
Ready out-of-the-box for easy installation Intelligent Fire alarm control panel and Emergency communication system are combined in
one cabinet which saves you money on installation and maintenance
Distributed SLC’s (Loop Card) in Field through In Farenhyt, the SLC loop cards can be distributed in the field and connected to main panel
SBUS through SBUS (RS-485 Bus) which significantly reduces project Cabling cost
The IFP-2100 Panel supports up to 2100 addressable Points (159 sensors/159 devices per
Point Flexibility loop). All 2100 points can be sensors which increases flexibility and cost savings in large
projects
Upto 32 nodes supporting over 67,200 points on a single peer to peer network with 64,000
watts of power for ECS applications. Supports both cooper wire and fibre optic network
Expandability
cabling. The IFP-NET-3 Graphic Monitoring software is used to monitor upto 200 panels in a
network with BACnet and Modbus support for seamless BMS integration
Patented Flexput circuits (Flexible Input or output circuit) that can be conveniently
Patented Flexput I/O circuits programmed to be used for Notification Appliance circuits, Auxiliary power (Constant Power,
Door Holder Power, Sounder Base Power) or as a conventional input circuit
Build in SWIFT wireless capability Compatible with SWIFT wireless devices provides Installation flexibility
Run jumpstart auto programming when Installation is complete to quickly add all detectors
JumpStart auto programming and modules to the system. This allows for Faster commissioning and Saves Installation
time
IDP-FIRE-CO (Addressable Combination Fire The IDP-FIRE-CO multifunctional device eliminates the need for a separate CO detector,
and CO Sensor) with B200S Intelligent Sounder Smoke Detector, Mini Horn, Monitor Modules, and all of the associated wiring and junction
Base boxes which saves costs and improved Aesthetics in applications like Hotel Rooms
Manufactured in North America with 20 years of FAS design and Manufacturing Expertise,
Quality & Reliability Farenhyt products have among the lowest warranty claims in the Industry. Systems proven
through extensive projects in North America
© 2016 by Honeywell International Inc. All rights reserved.
73

The Power of Connected

© 2016 by Honeywell International Inc. All rights reserved.


A/V Devices

Fire Fighter Telephone


Wide Area

ADA & Signage

BACNET / Modbus

IFP-NET-3 Graphical
Monitoring Software
Gas Detection/
Flame Detection
© 2016 by Honeywell International Inc. All rights reserved.
S'
...j-..I-...--+
6]u-bqJl
a{atr6^€l
@ oLr.oJl ^z'
rr,rot- c6t5o.ry

rly i-!l q.ll


ut
{m,mm""s
J.;!l ilr_r.ll &1- iiE- 't+Jl 6;x ct i:l :!-;-,;r-.iJl
ij*s+ll 6rj.ii-! iF Jl irJt^ir-)l cru.$l lsJ.i :fJl,.i;!"Yl
JrJl e+Jl -lLJl i52i ;J_1t----j.Jl
JJi.Li uFr
79.$..t J tr 6J. J.r! ,+.1
:6,lJl #!fll JJ suB/ELEc-010-REV.00 :d!fl| .i /O9l1;.-)3t ei3
2022
:k+ C.;J. rJiJl LJ. t-rr- C. di+31 JJsr .)}ll 'i-JJ a!,)
eDrylr JD-1l +:iulr i j,.r)l {. td t- llill (!rll Jlil rj.+r iL-.ri., .-'6.- Jir lJi (17-5-1)
.j+l! lill"l {- i*} :rJil .-l !r+ir !.|.a il,.iijl rlci:-Y! .,;E rl &.]Ell rrrjr Jr-jj i.,l'r 6!J irll rSJ rsr i-J] asi
t s-,,iJ .r-i-r jiLn rl]n 6E J,J- Jrlrl F:: r:, cjpj ,..$jr lj (17,5-2)
q iriu.llr J,qa! u5!l 'sr Jl ,lDi)r}rl\rl Jr..lr.r i.l,-JlllJlr i:JlLiil 5ti, lr.lill 'rl4
.!i,Li l5r ..aLLLJl slE .J,r J. Ul-,;Ji-tlt
t{-r.i-l-;r J ',-!ul a-l (-n lr d sr,i-rJJr & irJ,- JiJ3) iI cni-lr.

&Jr,ll JrU dE (28-46-00) .nr

.i!i rel & *,r i;lriJl &lS J..3r )pt $ t- 6+ r.-+ r6,s :J;liJl q^i
:tr-ill Jr! a-l
e r
'- ,Elr
"-_!t

.,rJ.ia-Y! cru
:,rtiLi:-Yl
r; lctidul ($r dj,.]l c,l-Jlj6jl 'iiL rlull {- isJti +Jii (HoN EY WELL) BY (farenhyt } .SJU ,j,J-ll Jlsl atln jt irl ;). eili
. lii.ll ...,.s SLD !!i. J+! C ul els !l.l,ll {i}!illr 3t+lll Jrl.rr. r 1-1-)"i,.11
ar-j-5ll lirl rr. iir- uLJl tukjJ { '-t n {i diii -1
r.1!l g" 4rt')l J"J.JI pp6 -l
e l eli.)ll e.I'ijl .rj. K.1-3

reLJll ;t-rll s gJlJ. e! F-ill !j. ti.i-4


Jl+ll ej.i jlr: "dk i r$ -5
.)ls! i.-tl" .:_,i'-, -g

6tJ.Sll Jrl+ .s 1$ll ot-J,I3b e3..j'i lrlJJi +- sll dsii,Jl +ri -7

a$, tu1' J Jl ell.J )r i-;rJl 6t!-)ll ($ r,l"e I .lnL.s.'.3+ E


. ;cl9)l
&-rr_r ! #rii;rtcl Jl eli-, J i-..:ll cil;slll .$ r.3'J
E
.JiU- ,J riiJl .rt].l"i-, .iti-l-r.Jl..r;r- C.6$. c..il:tuJ L!--$Li ii+l.r- c,,i J.)r! J.S.Jl i.*'iil .'lj. JL '. i' :f-,Lii-Yl {'i

,ru*YB \,,,,/ 'Ltl-)t -*u 7-t


24-l @l?tejal
:g-r"r.i"Jt -nr. g.1i

All datei to be entered in format: ddlmm/yyyy


.FIRE ALARM l-- 1of1
Submittal Reference #: 2121-02- MS-ELE-FAS-14 Date: 23/05/2022

Project Name:ABHA Executive office extension and rehabilitation Contractor: Bashaer Al-benaa Contracting Co

Altanfeethi Project Manager: ENG/ Youssef Al-Harby Consultant: Saudconsult Services Co

Submittal Details (by the Contractor)


Type of Submittal:
☒ Material ☐ Shop Drawings ☐ Design Drawings ☐ Test Report ☐ Manufacturer’s Data
☐ Method Statement ☐ Prequalification ☐ As- Built Drawings ☐ Sample ☒ Catalogues
☐ Others:
Discipline:
☐ Architectural ☐ Civil/ Structure ☐ Mechanical ☐ Electrical ☒ Project Controls ☐ General

Submittal Description:

# Description Revision # Date Copies

1 FIRE ALARM SYSTEM 00 23/05/2022 Soft copy

BRAND: HONEYWELL

SUPPLIER: POWER SOURCE EST

For the Contractor: Designation: Signature& Stamp:

Documents Review (by Consultant Team)


☐ Accepted ☐ Rejected

Reviewed by: Date: Signature:

Technical Review (by Consultant Team)


☐ A: Approved ☐ B: Approved as Noted ☐ C: Revise & Resubmit ☐ D: Rejected

Accepted conditionally as following


Provide compliance statement sheet to comply with project specification section 28 46 00
Update riser diagram as per discussion on the meeting 24/05/2022
Submit a warranty certificate & country of origin

Reviewed by: Date: Signature:


Approved by: Engr.Ashraf Helal Date: 24-05-2022 Signature: Ashraf Helal
Approval shall not relieve Contractor of his liabilities under the Contract or constitute authorization of any change to Contract Documents.

TECHNICAL SUBMITTAL FORM


I
ffi llE- . r
! !0 I
,
,-l \
EE !l r I I
trDtrtr
iI7'
II
EOO 3t
5I; iI
E} E
Tb
+
N t
N.
\
li
E' 5
l0 iil<
aE
I3
* ,a a
t
6
E
ir T;rl
a
I s ! a
E
3 !
I E
2
2
,
J
e
I
E
aq
t5
e
i
&
a
"t EE
?r a
ii
22
E
!
t EE
4 el
t
4E
id
t-
-
6
5l
a- I 3s
3 g B
a
Ec
Etr I
I 6 IE
ca 'd
!l
!
= I s {- a
g
I
I
F
i f,
e
rd 1 II d
i;E
t5;
r, E: H E
i fr
T !Bi
=
3E P
g 3 E
\ 3
i
I BI t{t h:s
a
I
I -t
EI
a
4
E rl
I
i
;q
I l
I
ii I E
E,E t !
! EJE EO , I
a65i I 8\
isisi;:;EE
I'5E
Eo $
I;
Ii
T
I N itE E
Dated: 1 Oct 2020 Reference No. S/2018/223

To Whom It May Concern:

This letter is to state that Honeywell owns and operates factories in over 30 countries. Products are
manufactured under the brand name and logo of Honeywell Corporation in USA, Italy, United Kingdom,
Mexico, Canada, Japan, Korea, Taiwan, China, Australia, South Africa, Switzerland and the Netherlands.
Honeywell hereby confirms that all Honeywell brand products have been tested and in accordance by our
Global Quality Assurance Department under the direct control and leadership of our USA Head quarters to
ensure the products Quality and Performance.

The Standard warranty for Honeywell Farenhyt Fire Alarm is Three years against manufacturing defects from
the date of manufacture. Please reach out to the undersigned for any clarifications

Yours sincerely,

Jabri, Fahmi
Strategy and Marketing Director, Honeywell Security and Fire
Dated: 15 Oct 2018 Reference No. S/2018/146

To Whom It May Concern:

Country of Origin Certificate

This letter is to state that Honeywell owns and operates factories in over 30 countries. Products are
manufactured under the brand name and logo of Honeywell Corporation in USA, Italy, United Kingdom,
Mexico, Canada, Japan, Korea, Taiwan, China, Australia, South Africa, Switzerland and the Netherlands.
Honeywell hereby confirms that all Honeywell brand products have been tested and in accordance by our
Global Quality Assurance Department under the direct control and leadership of our USA Head quarters to
ensure the products Quality and Performance.

Further, Honeywell manufactures the following list of products in the countries as listed across it only:

Product code Description COO

Farenhyt 2100 point Addressable Fire Panel, 4 line LCD display with 40
characters per line, One SLC loop card inbuild, 159 Detectors and 159
Modules per loop, Additional Loop cards can be expanded through
USA
5815RMK (Remote mounting Kit which accomodates 2 SLC Cards (6815)),
Network upto 32 panels, inbuild eight on-board Flexput™ circuits,Built in
USB interface,for programming,Four programmable function keys,
IFP-2100HV 240VAC @ 50/60Hz, 2.8A , UL Listing and FM Approved, Black Cabinet
6815 SLC Loop Expander which supports 159 Detectors and 159 Modules USA
5815RMK Remote Mounting Kit USA
SK-NIC Network Interface Card USA
SK-FSL Network Interface Card USA
BAT-12550 BATTERY, 12 VOLT, 55 AH. VIETNAM
BATTERY BOX, HOLDS UP TO TWO BAT-12260 (26 AH) OR BAT-12550 (55
USA
BB-55F AH)
ECS- Amplifier 50/100 Watt Dual Channel / Back-up Amp -high Voltage 220vac USA
DUAL50WHV 50 Hz
BAT-12180-BP TWO (2) BAT-12180 (12V, 18AH) SHIPPED IN EACH BULK PACK VIETNAM
IFP-NET-3 Software and key (a key is required on each PC in system) USA
Installation packages includes Gateway interface, Cabinet, and 5824 USA
IFPN-GW-KIT Serial/Parallel printer interface
RA-2000 4 X 40 Display Remote Annunciator. Red USA
IDP-PHOTO Intelligent Addressable Photoelectric Detector MEXICO
B501 4" Mounting Base MEXICO
Intelligent Sounder Base High/low Volume Output W/ansi Temporal 3 Or MEXICO
B200S Temporal 4, Continuous, March Or Custom Tone
IDP-FIRE-CO Advanced Multi-Criteria Fire/CO Detector ITALY
RA100Z Remote LED. Mounts to single gang box. MEXICO
IDP-PULL-DA Addressable Manual Dual Action Pull Station MEXICO
Intelligent Photoelectric Replacement Smoke Detector remote test MEXICO
IDP-PHOTOR capable, for use with DNR (W) duct smoke detector
DNR InnovairFlex intelligent duct detector, non-relay, does not include head MEXICO
ST-5 Detector sampling tube, 4-8’ ducts MEXICO
P48-21-00 Replacement End Cap for Metal USA
RTS151KE Key-Activated Remote Test station MEXICO
IDP-BEAM Intelligent Addressable Beam Smoke Detector MEXICO
BEAMMMK Projected Beam Smoke Detector Multi-Mount Kit, Wall or Ceiling. MEXICO
BEAMLRK Projected Beam Smoke Detector Long Range Kit, Increases Distance. DE
RTS151 Remote Test Station. MEXICO
Intelligent Addressable Multicriteria Photoelectric Smoke Detectorc MEXICO
IDP-ACCLIMATE (Smoke with Thermal (Base Not Included)
9400X FAAST XT 4 CHANNEL MEXICO
761520.10 Pipe (ABS), length 3 m, 25 mm PU 10 pcs. Total 30 mts GREAT BRITAIN
761525.10 Sleeve (ABS) for 25 mm pipe PU 10 pcs. GREAT BRITAIN
761523.10 45° angle (ABS) for 25 mm PU 10 pcs. GREAT BRITAIN
761522.10 90° angle (ABS) for 25 mm PU 10 pcs. GREAT BRITAIN
761526.10 End cap (ABS) for 25 mm pipe PU 10 pcs. GREAT BRITAIN
761542.10 Suctions hose set for 25 mm GREAT BRITAIN
761524.10 T-piece (ABS) for 25 mm pipe PU 10 pcs. GREAT BRITAIN
IDP-CONTROL Addressable Control Module MEXICO
Intelligent Addressable Thermal Detector Fixed Temp 135 (Base Not MEXICO
IDP-HEAT Included)
Intelligent Addressable Fixed temperature and rate-of rise thermal MEXICO
IDP-HEAT-ROR detector (Rate-of-rise detection 15ºF/min (9ºC/min) (Base Not Included)
Intelligent Sounder Base High/low Volume Output W/ansi Temporal 3 Or MEXICO
B200S Temporal 4, Continuous, March Or Custom Tone
FSL100-UV UVIR flame detector RED, ATEX FM EN54 NETHERLANDS
S2000A Sensor cable MEXICO

Yours sincerely,

Jabri, Fahmi
Strategy and Marketing Director, Honeywell Security and Fire
S.No. Description Model No. QTY

FARENHYT BY HONEYWELL
Farenhyt 2100 point Addressable Fire Panel, 4 line, LCD display with 40
characters per line, One SLC, loop card in build, 159 Detectors and 159 Modules,
per loop, Additional Loop cards can be expanded, through 5815RMK (Remote
1 mounting Kit which, accommodates 2 SLC Cards (6815)) , Network upto, 32 HONEYWELL#IFP-2100HV 1
panels, in build eight on-board Flexput™, circuits, Built in USB interface for
programming, Four programmable function keys,
240VAC @ 50/60Hz, 2.8A , UL Listing and FM, Approved, Red Cabinet
4 X 20 Display Remote Annunciator (80-character
backlit LCD display ).Red, Larger keypad buttons
for system reset and silence , Five status LEDs for
2 HONEYWELL#RA-1000R 1
alarms, supervisory, trouble, silence and AC power
indications, Activated by user code or fire fighter
key

3 TRIM RING FOR USE W/ 5860R & RA-1000R, RED HONEYWELL#5860TR 1

Intelligent Addressable Photoelectric Smoke Detector (Ivory Color) (Base Not


4 HONEYWELL#IDP-PHOTO-IV 80
Included)

5 4” standard flangeless mounting base (Ivory Color) HONEYWELL#B501-IV 80

6 Intelligent Addressable Supervised Control Module HONEYWELL#IDP-CONTROL 8

7 Supervised, Single Contact HONEYWELL#IDP-MONITOR 10


Farenhyt Series

Scalable Analog/Addressable Fire


Alarm Control System
IFP-2100 /RFP-2100
The IFP-2100 (red) and IFP-2100B (black) are intelligent analog/
addressable Fire Alarm Control Panels (FACP). The basic IFP-2100
panel contains one built in signaling line circuit (SLC), which can
support 159 IDP/SK sensors and 159 IDP/SK modules or 127 SD
devices per loop. Additional SLC loops can be added using the model
6815 SLC expander for System Sensor devices to increase the overall
point capacity to 2100 or model 5815XL for Hochiki devices to increase
the overall point capacity to a maximum to 2032 points per panel.

IFP-2100 has the interconnection capability for up to 32 panels. The


system has two modes of operation, multiple panels covering one larger
building, or multiple independent buildings. The RFP-2100 (red) or RFP-
2100B (black) can be used in a networked system where at least one IFP-
2100 is in the system. It is the same as the IFP-2100 without the display.
IFP-2100B
IFP-2100 has eight on-board Flexput™ circuits that can be configured
for auxiliary power, notification outputs, or for conventional smoke
detector inputs (Class A or Class B). The FACP also has a Built in
dual phone line digital alarm communicator/transmitter (DACT),
IP or optional cellular technologies, Form C trouble relay, and two
programmable Form C relays. IFP-2100 has powerful features such
as detector sensitivity, day/night thresholds, drift compensation,
pre-trouble maintenance alert, and calibration trouble alert.

The IFP-2100 supports a variety of devices, including RA-


2000, RA-1000 or RA-100 remote annunciator, 5824 serial/
parallel printer interface module (for printing system reports),
RPS-1000 power module, and IDP, SK or SD devices.

F E AT U R E S & B E N E F I T S
• RFP-2100 or • Four line LCD display • Network card allows • JumpStart • Supports up to four
RFP-2100B can be with 40 characters per copper network AutoProgramming® SWIFT wireless
used in a networked line connection with a feature for easy gateways. Each
system where at lease multi-mode or programming gateway can have up
• Available in a red or
one IFP-2100 is in the single-mode fiber to 49 wireless devices
black cabinet • Renewable license on
system connection option
downloading software • Supports Class B
• IFP-2100 or
• Network support for • Built-in dual phone helps inhibit (Style 4) and Class A
RFP-2100 can be
up to 32 Sites line, digital alarm unauthorized (Style 6 or Style 7
surface or flush
communicator/ programming configuration for SLC,
• Built-in support for up mounted
transmitter (DACT), IP and SBUS.
to 159 IDP/SK • Firmware can be
• Four programmable or optional cellular
detectors and 159 upgraded in the field • Built in USB interface
function keys technologies
IDP/SK modules or for programming
127 SD SLC devices
IFP-2100 / RFP-2100 Technical Specifications
SPECIFICATIONS ORDERING INFORMATION For a complete listing of all
Physical: IFP-2100 - Intelligent Fire Alarm Control Panel. compliance approvals and
certifications, please visit
Overall Dimensions: 26.4” H x 16.4" W x 4.11” D Red
www.farenhyt.com.
Weight: 45 lbs. IFP-2100B - Intelligent Fire Alarm Control
Color: Red or Black Panel. Black Microsoft, Windows, and
RFP-2100 - Remote Fire Alarm Panel without the Windows Logo are
Environmental Operating Temperature: 32°F to registered trademarks
120°F (0°C to 49°C) built in display. Red
or trademarks of
Humidity: 0 to 93% relative humidity (non- RFP-2100B - Remote Fire Alarm Panel without Microsoft Corporation.
condensing) built in display. Black
All other trademarks
SBUS ACCESSORIES are the property of their
ELECTRICAL: respective owners.
IFP-2100 Primary AC: 120 VAC @ 50/60 Hz, 5.0A RA-2000, RA-1000, RA-1000R, RA-100,
Total Accessory Load: 9A @ 24 VDC power-limited RA-2000GRAY - Remote annunciator. Four Line This document is not
LCD with 40 characters per line intended to be used for
Standby Current: 230 mA installation purposes. We
6815 - Signal Line Circuit (SLC) Expander for
Alarm Current: 415 mA try to keep our product
IDP/SK devices information up-to
Battery Charging Capacity: 17 to 55 AH
5815XL - Signal Line Circuit (SLC) Expander for date and accurate. We
Battery Size: 18 AH max. allowed in control panel SD devices cannot cover all specific
cabinet. Larger capacity batteries can be housed in applications or anticipate
RPS-1000 - Power Supply
RBB accessory cabinet. all requirements. All
5496 - NAC Expander
Six Conductor Wiring: Two voice bus & four SBUS specifications are subject
5824 - Serial/Parallel Module to change without notice.
FLEXPUT CIRCUITS 5880 - LED I/O Module
For Technical
Eight circuits that can be programmed 5865-3/-4 - LED Annunciator
Support, Please call
individually as: 5883 - Relay Interface 800-446-6444.
Notification Circuits: 3A per circuit @ 24 VDC,
power limited MISCELLANEOUS ACCESSORIES
Auxiliary Power Circuits: 3A per circuit @ 24 VDC, SKSS-3 - Software Suite. Provides
power limited. programming, upload/download and event
reporting
Initiation Circuit: 100 mA per circuit @ 24 VDC,
power-limited RBB - Remote Battery Box Cabinet. Use for
backup batteries up to 35 AH. Dim: 16" W x 10"
APPROVALS H x 6" D
NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA SK-SCK - Seismic Compliance Kit
72: Central Station; Remote Signalling; Local SK-NIC - Network Interface Card
Protective Signalling Systems; Auxiliary Protected SK-FML - Multi Mode Fiber Card
Premises Unit; & Water Deluge Releasing Service SK-FSL - Single Mode Fiber Card
Other Approvals: CELL-MOD - Cellular Communicator in Plastic
UL Listing; CSFM (pending); COA (pending); Enclosure
OSHPD (CA) (pending), FM (pending) CELL-CAB-SK - Cellular Communicator in
Metal Enclosure with lock and key
APPROVED RELEASING SOLENOIDS
Asco T8210A107 24 VDC 3 A max 0 Hz
Asco 8210G207 24 VDC 3 A max 0 Hz

COMPATIBLE DEVICES
See the data sheets listed below for a complete
listing of the IDP, SK, SWIFT or SD devices.
350361 - IDP Device Protocol data sheet
53623 - SK Device Protocol data sheet
350360 - SD Device Protocol data sheet
350615 & 350617 - SWIFT devices data sheet

For more information


www.farenhyt.com

Honeywell
12 Clintonville Road
Northford, CT 06472
800-328-0103 Doc 351602| Rev A | 01/17
www.farenhyt.com © 2017 Honeywell International Inc.
RA-1000 / RA-1000R
Remote Annunciator
The RA-1000 is a remote annunciator used to operate and program
IFP-series fire alarm control panels (FACP's). The RA-1000’s keypad and
display match the built-in annunciator of the IFP-1000 control panel.

The remote annunciator connects to the control panel via the RS-485
system bus. When the system is in normal operation and has AC power, the
Power LED is lit and all other LEDs are off. The other LEDs turn on as
alarms, supervisories, troubles, system silenced and AC power losses occur.

INSTALLATION
The RA-1000 can be surface or flush mounted. Use the optional trim ring
for surface mounts. When flush mounting an electrical box is optional. If RA-1000R /RA-1000
using an electrical box, use a 4S, single-gang, or double-gang box.

COMPATIBILITY
The RA-1000 is compatible with the following Farenhyt Series FACPs:

• IFP-2100 / IFP-2100ECS

• IFP-1000/ECS

• IFP-100/ECS

• IFP-300 / IFP-300ECS

• IFP-75

• IFP-50

F E AT U R E S & B E N E F I T S
• 80-character backlit • Initiate and end fire • Five Status LEDs for; • Support for
LCD display (4 lines drills with a single key alarms, supervisory, simultaneous use of
with 20 characters on press trouble, silence and AC multiple RA-1000s
each line) power indications
• View current status by • Wiring lengths up to
• Tactile/audible alarms, supervisories, • Available in red or gray 6000 ft. from the
feedback or troubles color FACP (depending on
wire gauge and
• RS-485 SBUS • On-board piezo • UL listed, complies
number of devices on
interface to panel sounder audibly with NFPA 72
SBUS)
indicates alarms,
• Larger keypad buttons • Accepts user codes or
troubles, and
for system reset and fire fighter’s key
supervisories
silence
RA-1000 Technical Specifications
For a complete listing of all
compliance approvals and
certifications, please visit
www.farenhyt.com.

Microsoft, Windows, and


the Windows Logo are
registered trademarks
or trademarks of
Microsoft Corporation.

Honeywell® is a
registered trademarks
of and Farenhyt™ is a
trademark of Honeywell
International, Inc.

This document is not


intended to be used for
installation purposes. We
try to keep our product
information up-to
date and accurate. We
cannot cover all specific
applications or anticipate
all requirements. All
specifications are subject
to change without notice.

For Technical
SPECIFICATIONS ORDERING INFORMATION Support, Please call
Dimensions: 9.1”W x 7.4”H x 1.5”D (23.1W x 18.8H x RA-1000R: Remote Annunciator. Four line LCD 800-446-6444.
3.8D cm) annunciator with 20 characters per line. Red.
RA-1000: Remote Annunciator. Four line LCD
ENVIRONMENTAL annunciator with 20 characters per line. Gray.
Operating Temperature: 32°F to 120°F (0°C to
49°C) OPTIONAL ACCESSORIES
Humidity: 10% to 93% relative humidity (non- 5860TR: Red Trim Ring. For surface mounting.
condensing) 5860TG: Gray Trim Ring. For surface mounting.

ELECTRICAL: AGENCY LISTINGS AND APPROVALS


Operating Voltage: 24VDC • MEA Approved
Standby Current: 20mA
• CSFM Approved
Alarm Current: 25mA
Wiring Distance: 6,000 ft max. from FACP • FM Approved
(depending on wire gauge and number of devices • UL listed
on the SBUS)
Max per System: IFP-50 or IFP-75 (8); IFP-100/
ECS or IFP-1000/ECS (12); IFP-300/ECS (16);
IFP-2100/ECS (31)

For more information


Learn more about Honeywell’s Farenhyt Series and
other products available by visiting
www.farenhyt.com>

Honeywell Security & Fire


12 Clintonville Road
Northford, CT 06472 Doc 350071| Rev F | 12/17
800-328-0103 © 2017 Honeywell International Inc.
Intelligent Bases Standard, Relay, Isolator, Sounder, and Low-Frequency Sounder Bases
General
To meet local code and application requirements, NOTIFIER® offers
standard 4" and 6" bases, as well as, specialty base designs includ-
ing relay, isolator, sounder and low frequency sounder options for
the new 900 Series of addressable detectors as well as previous
generations.
The standard 4" and 6" bases offer a plug-in detector base intended
for use in intelligent systems, with screw terminals identified with a
(+ and –). The 4" base offers a compact design while the 6" base
provides compatibility with a wider range of junction boxes.
B300-6 Standard B200S-WH
The specialty bases support application driven requirements. These 6” Base (White) Sounder Base (White)
bases employ a separate mounting plate that installs on various
junction box sizes to eliminate unsightly surface-mount boxes. The
mounting plate enables pre-wiring of all connections to speed and
simplify installation.
Relay bases provide one form-C contact relay for control of auxiliary
functions, such as door closure and elevator recall. The relay can
operate in two different modes (short and long delay). The activation
time for the short delay is 60-100 milliseconds, while the activation
time for the long delay is 6-10 seconds. A shunt with pin headers,
located on the base PC board, is used to set the delay timing.
Isolator bases allow the Signaling Line Circuit (SLC) loop to operate
under fault conditions created from a short circuit preventing an B501-WHITE Flangeless B501-BL Flangeless
entire communication loop from being disabled. The base isolates 4” Base (White) 4” Base (Black)
the section of the loop containing the short circuit from the remain-
der of the circuit and automatically restores when the fault is cor-
rected. Specifications
Sounder and low frequency sounder bases are designed for new NOTE: Specifications applies to all model variants “A”, “-BL”, “-LF”, “-IV”,
and existing dwelling unit applications. They offer maximum flexibil- -WH, -WHITE. See Product Line Information for detailed model descrip-
ity in installation, configuration, and operation to meet or exceed UL tion.
268 and UL 464 requirements. The low frequency sounder bases Diameter
are designed to meet the NFPA 72 sleeping space requirement to
produce a fundamental frequency of 520 Hz +/- 10% with a square • B501-WHITE: 4" (10.16 cm) diameter.
wave or its equivalent. Studies show that a lower frequency, cen- • B300-6: 6.1" (15.49 cm) diameter.
tered around 520 Hz, is the most ideal to wake sleeping occupants, • B224BI, B224RB: 6.2" (15.748 cm) diameter.
even those with mild to severe hearing loss.
• B200S, B200SR, B200SCOA: 6.875" (17.46 cm) diameter.
The B200SR sounder and -LF sounder bases (B200SR-WH/ Wire gauge:
B200SR-IV/B200SR-LF-WH/B200SR-LF-IV) are fully compatible
with existing B501BH Series sounder base installations. The device • B224BI, B224RB: 14 to 24 AWG.
enables users to select one of two B501-supported tones (ANSI • B300-6, B210LP, B501, B200S, B200SR, B200SCOA: 12 to 24
Temporal 3 or Continuous) through a jumper. AWG
The B200S sounder and -LF sounder bases (B200S-WH/B200S-IV/ Temperature range:
B200S-LF-WH/B200S-LF-IV) adopt the same address as the detec- • B224BI, B224RB, B200S, B200SR, B200SCOA: 32°F to 120°F
tor, but use a unique device type on the loop. The Fire Alarm Control (0°C to 49°C).
Panel (FACP) can use that address to command an individual
• B300-6, B210LP, B501: -4°F to 150°F (-20°C to 66°C).
sounder — or a group of sounders — to activate. The command set
from the FACP can be tailored to multiple event-driven tone outputs Humidity range: 10% to 93% RH, non-condensing.
allowing selection of volume (75 or 85 dBA), tone (ANSI Temporal 3, System temperature and humidity ranges: This system meets
ANSI Temporal 4, or March Time) and group. In addition, some NFPA requirements for operation at 0°C to 49°C (32°F to 120°F);
FACPs will enable custom tone patterns. The B200S series sounder and at a relative humidity (non-condensing) of 85% at 30°C (86°F)
bases recognize the System Sensor synchronization protocol. This per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC.
enables them to be used as a component of the general evacuation However, the useful life of the system’s standby batteries and the
signal — along with other System Sensor AV appliances — when electronic components may be adversely affected by extreme tem-
connected to a power supply or FACP output capable of generating perature ranges and humidity. Therefore, it is recommended that
the System Sensor synchronization pulses. this system and all peripherals be installed in an environment with a
nominal room temperature of 15°C to 27°C (60°F to 80°F).

DN-60054:K • 7/18/2018 — Page 1 of 3


Electrical Ratings Product Line Information
FOR B300-6 SERIES BASES: INTELLIGENT BASES
Operating voltage: 15 to 32 VDC NOTE: “A” suffix indicates ULC Listed model.
Standby current: 170 µA maximum NOTE: “-IV” suffix indicates Ivory color model.
NOTE: “-BL” suffix indicates Black color model.
FOR B501 SERIES BASES:
NOTE: “-WH” and “-WHITE” suffix indicates White color model.
Operating voltage: 15 to 32 VDC
B210LP: Flanged mounted base.
Standby current: 150 µA maximum
B210LPA: Same as B210LP; ULC listed.
FOR B200 SERIES BASES:
B210LPBP: Bulk pack of B210LP, contains 10.
External supply voltage: 16 to 33 VDC (FWR)
B300-6: White, 6” base, standard flanged low-profile mounting base.
Standby current:
B300A-6: Same as B300-6, ULC listed.
500 µA maximum.
B300-6-BP: Bulk pack of B300-6, package contains 10;.
Alarm current:
B300-6-IV: Ivory,6” base, standard flanged low-profile mounting
• B200S(A)(-IV)(-WH) base.
– 35 mA maximum at high-volume setting
B300A-6-IV: Ivory, 6” standard flanged low-profile mounting base,
– 15 mA maximum at low-volume setting ULC listed.
• B200S-LF(-IV)(-WH) High-volume setting: B501-WHITE: White, 4” standard European flangeless mounting
– 70 mA maximum @ 33.0 VDC base. UL/ULC listed.
– 90 mA maximum @ 24.0 VDC B501-WHITE-BP: Bulk pack of B501-WHITE contains 10.
– 140 mA maximum @16.0 VDC B501-BL: Black, 4” standard European flangeless mounting base.
• B200S-LF(-IV)(-WH) Low-volume setting: UL/ULC listed.
– 15 mA maximum @ 33.0 VDC B501-IV: Ivory color, 4” standard European flangeless mounting
– 20 mA maximum @ 24.0 VDC base. UL/ULC listed.
– 25 mA maximum @ 16.0 VDC B224RB-WH: White, relay base.
• B200SR(A)(-IV)(-WH) B224RB-IV: Ivory, relay base.
– 35 mA maximum
B224RBA-WH: White, relay base, ULC listed.
• B200SR-LF(-IV)(-WH)
B224RBA-IV: Ivory, relay base, ULC listed.
– 65 mA maximum @ 33.0 VDC
– 90 mA maximum @ 24.0 VDC B224BI-WH: White, isolator detector base.
– 125 mA maximum @16.0 VDC B224BI-IV: Ivory isolator detector base.
• B200SCOA(-IV)(-WH) B224BIA-WH: White, isolator detector base, ULC listed.
– 40mA Max (DC) B224BIA-IV: Ivory isolator detector base, ULC listed.
– 70mA Max (FWR) B200S-WH: White, Intelligent addressable sounder base capable of
SLC operating voltage: 15 to 32 VDC producing sound output in high or low volume with ANSI Temporal 3,
ANSI Temporal 4, continuous tone, marching tone, and custom tone.
SLC standby current: See applicable sensor specification.
Uses FlashScan® protocol.
Sound output:
B200S-IV: Ivory, Intelligent addressable sounder base capable of
• B200S(A)(-LF)(-IV)(-WH), high-volume*: Greater than 85 dBA producing sound output in high or low volume with ANSI Temporal 3,
minimum. ANSI Temporal 4, continuous tone, marching tone, and custom tone.
• B200S(A)(-LF)(-IV)(-WH), low-volume*: Greater than 75 dBA Uses FlashScan® protocol.
minimum. B200SA-WH: Same as B200S-WH, ULC listed.
• B200SR(A)(-LF)(-IV)(-WH)*: Greater than 85 dBA minimum. B200SA-IV: Same as B200S-IV, ULC listed.
• B200SCOA(-IV)(-WH), high-volume**: Greater than 87 dBA mini-
mum. B200SCOA-WH: White, Intelligent, programmable sounder base in
English/French (required in Canada for ULC applications with SO
• B200SCOA(-IV)(-WH), low-volume**: Greater than 85 dBA mini- Series detector applications.
mum
*Measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone)
B200SCOA-IV: Ivory Intelligent, programmable sounder base in
**Measured in a ULC anechoic room at 10 feet, 24 Volts continuous tone) English/French (required in Canada for ULC applications with SO
Series detector applications, ULC listing.
FOR B224BI, B224RB (A) (-IV) (-WH):
B200S-LF-WH: White, Low Frequency Intelligent, programmable
Operating voltage: 15 to 32 VDC (powered by SLC) sounder base. Produces a fundamental frequency of 520 Hz +/-
Standby ratings: <450 µA maximum @ 24 VDC 10% with a square wave or its equivalent; designed to meet the
NFPA 72 sleeping space requirement.
Set time (B224RB(A)(-IV)(-WH) only): short delay 60-100 millisec-
onds; long delay 6-10 seconds B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable
sounder base. Produces a fundamental frequency of 520 Hz +/-
Reset time (B224RB(A)(-IV)(-WH) only): 20 milliseconds maximum 10% with a square wave or its equivalent; designed to meet the
Relay characteristics (B224RB(A)(-IV)(-WH) only): two-coil latch- NFPA 72 sleeping space requirement.
ing relay; one Form-C contact; ratings (UL/CSA): 0.9 A @ 125 VAC,
0.9 A @ 110 VDC, and 3.0 A @ 30 VDC

Page 2 of 3 — DN-60054:K • 7/18/2018


B200SR-WH: White, Intelligent sounder base capable of producing M02-04-00: Test magnet.
sound output with ANSI Temporal 3 or continuous tone. Intended for M02-09-00: Test magnet with telescoping handle.
retrofit applications.
CK300: White, detector color kit. Pack of 10.
B200SR-IV: Ivory, Intelligent sounder base capable of producing
sound output with ANSI Temporal 3 or continuous tone. Intended for CK300-IR: White, detector color kit for use with FPTI and FCO
retrofit applications. Series detectors. Pack of 10.
B200SRA-WH: Same as B200SR-WH, ULC listed. CK300-IV: Ivory, detector color kit. Pack of 10.
B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listed. CK300-IR-IV: Ivory, detector color kit for use with FPTI and FCO
Series detectors. Pack of 10.
B200SR-LF-WH: White, Low Frequency Intelligent, programmable
sounder base. Produces a fundamental frequency of 520 Hz +/- CK300-BL: Black, detector color kit. Pack of 10.
10% with a square wave or its equivalent; designed to meet the CK300-IR-BL: Black, detector color kit for use with FPTI and FCO
NFPA 72 sleeping space requirement. Intended for retrofit applica- Series detectors. Pack of 10.
tions.
B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable Agency Listings and Approvals
sounder base. Produces a fundamental frequency of 520 Hz +/-
10% with a square wave or its equivalent; designed to meet the The listings and approvals below apply to intelligent bases as noted.
NFPA 72 sleeping space requirement. Intended for retrofit applica- In some cases, certain modules or applications may not be listed by
tions. certain approval agencies, or listing may be in process. Consult fac-
tory for latest listing status.
MOUNTING KITS AND ACCESSORIES • UL/ULC Listed: S1115
TR300: White, replacement flange for B210LP(A), B300(A)-6 bases. • FM Approved
TR300-IV: Ivory, replacement flange for B210LP(A), B300(A)-6-IV • CSFM: 7300-1653:0109, 7300-1653:0126, 7300-1653:0213,
bases. 7300-1653:0236
RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Mounts to a
U.S. single-gang electrical box. For use with B501(A) and B300(A)-
6.

Junction Box Selection Guide


4.0" Sq.
Single Double
Base Models 3.5" Oct. 4.0" Oct. 4.0" Sq. with 3.0" 50 mm 60 mm 70 mm 75 mm
Gang Gang mud ring
B200S, B200SR,
Yes Yes Yes Yes Yes Yes No No No No
B200SCOA
B501 No No Yes No No Yes Yes Yes Yes No
B210LP, B300-6 Yes No Yes Yes Yes Yes No No No No
B224BI, B224RB Yes Yes Yes Yes Yes Yes No No No No
NOTE: Box depth contingent on base and wire size.
Refer to National Electric Code or applicable local codes for appropriate recommendations.
NOTE: Applies to all model variants “A”, “-BL”, “-LF”, “-IV”, “-WH”, and “-WHITE”. See Product Line Information for detailed model description.

This document is not intended to be used for installation purposes.


We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
NOTIFIER FlashScan®, NOTIFIER® and System Sensor® are regis-
12 Clintonville Road tered trademarks of Honeywell International Inc.
Northford, CT 06472 ©2018 by Honeywell International Inc. All rights reserved.
203.484.7161 Unauthorized use of this document is strictly prohibited.
www.notifier.com Country of Origin: Mexico
INSTALLATION AND MAINTENANCE INSTRUCTIONS

I56-6531-001
Farenhyt® Series Black

IDP-PHOTO-W and IDP-PHOTO-IV 12 Clintonville Road, Northford, CT 06472-1610


Phone: 203-484-7161 Fax: 203-484-7118
Intelligent Photoelectric Smoke Sensors www.Farenhyt.com
SPECIFICATIONS
Operating Voltage Range: 15 to 32 VDC
Operating Current @ 24 VDC: 200 uA (one communication every 5 seconds with green LED blink on communication)
Maximum Alarm Current: 2 mA @ 24 VDC (one communication every 5 seconds with red LED solid on)
Maximum Current: 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED solid on)
Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range: 32°F to 122°F (0°C to 50°C)
Air Velocity: 0 to 4000 ft./min. (0 to 1219.2 m/min.)
Height: 2.0˝ (51 mm) installed in B300-6 Base
Diameter: 6.2˝ (156 mm) installed in B300-6 Base; 4.1˝ (104 mm) installed in B501 Base
Weight: 3.4 oz. (95 g)
Isolator Load Rating: 0.0063*
*Please refer to your isolator base/module manual for isolator calculation instructions.

UL 268 listed for Open Air Protection. WIRING GUIDE


UL268A listed for Duct Applications. All wiring must be installed in compliance with the National Electrical Code,
This sensor must be installed in compliance with the control panel system applicable local codes, and any special requirements of the Authority Having
installation manual. The installation must meet the requirements of the Au- Jurisdiction. Proper wire gauges should be used. The installation wires should
thority Having Jurisdiction (AHJ). Sensors offer maximum performance when be color-coded to limit wiring mistakes and ease system troubleshooting. Im-
installed in compliance with the National Fire Protection Association (NFPA); proper connections will prevent a system from responding properly in the
see NFPA 72. event of a fire.
Remove power from the communication line before installing sensors.
GENERAL DESCRIPTION
1. Wire the sensor base (supplied separately) as shown in the wiring
Models IDP-PHOTO-W and IDP-PHOTO-IV are plug-in type smoke sensors that
diagram. (See Figure 2.)
combine a photoelectronic sensing chamber with addressable-analog commu-
nications. 2. Set the desired address on the sensor address switches. (See Figure 1.)
The sensors transmit an analog representation of smoke density over a com- 3. Install the sensor into the sensor base. Push the sensor into the base while
munication line to a control panel. Rotary dial switches are provided for set- turning it clockwise to secure it in place.
ting the sensor’s address. (See Figure 1.) 4. After all sensors have been installed, apply power to the control panel and
activate the communication line.
FIGURE 1. ROTARY ADDRESS SWITCHES:
5. Test the sensor(s) as described in the TESTING section of this manual.
6 7 89 6 7 8 9
5 10 5 CAUTION
4 11 4
3 12 3 Dust covers provide limited protection against airborne dust particles during
2 13 2
1 0 1514 10 shipping. Dust covers must be removed before the sensors can sense smoke.
TENS ONES C0162-00 Remove sensors prior to heavy remodeling or construction.
Two LEDs on the sensor are controlled by the panel to indicate sensor status.
An output is provided for connection to an optional remote LED annunciator FIGURE 2. WIRING DIAGRAM:
(P/N RA100Z).
Remote CAUTION: Do not loop wire under
Honeywell Farenhyt panels offer different feature sets across different models. Annunciator terminal 1 or 2. Break wire run to
As a result, certain features of the photoelectric sensors may be available on + - supervise connections.
some control panels, but not on others. These devices support IDP protocol
mode. The possible features available if supported by the control panel in- (+)
UL Listed Compatible

clude:
Control Panel

1. The sensor’s LEDs can operate in three ways—on, off, and blinking–and + + + +
2
+ +
2
2 – – –
they can be set to red, green, or amber. This is controlled by the panel. RA
1
RA
3
1
RA
1
3 3
2. The remote output may be synchronized to the LED operation or con-
trolled independent of the LEDs.
3. Devices are point addressable up to 159 addresses. (–)
Please refer to the operation manual for the UL listed control panel for specific (–) CLASS A OPTIONAL WIRING
operation. The photoelectric sensors require compatible addressable com- (+)
munications to function properly. Connect these sensors to listed-compatible
C0129-10
control panels only. TAMPER-RESISTANCE
Intelligent photoelectric smoke sensors include a tamper-resistant capability
SPACING that prevents their removal from the base without the use of a tool. Refer to
Honeywell recommends spacing sensors in compliance with NFPA 72. In low the base manual for details on making use of this capability.
air flow applications with smooth ceilings, space sensors 30 feet apart (9.1 m).
For specific information regarding sensor spacing, placement, and special ap-
plications, refer to NFPA 72 or the System Smoke Detector Application Guide,
available from Honeywell.
Duct Applications: IDP-PHOTO-W and IDP-PHOTO-IV are listed for use in
ducts. See Duct Smoke Detectors Applications Guide HVAG53 for details on pen-
dant mount applications. NOTE: Intelligent photoelectric smoke sensors are
also listed for use inside DNR(W) duct smoke detectors.

Preliminary 1 I56-6531-001
09/23/2019
TESTING 6. Reinstall the chamber cover/screen assembly by sliding the edge over the
Before testing, notify the proper authorities that the system is undergoing sensing chamber. Turn until it is firmly in place.
maintenance, and will temporarily be out of service. Disable the system to 7. Replace the cover using the LEDs to align the cover and then gently push-
prevent unwanted alarms. ing it until it locks into place.
All sensors must be tested after installation and periodically thereafter. Test- 8. Reinstall the detector.
ing methods must satisfy the Authority Having Jurisdiction (AHJ). Sensors
9. Test the detector as described in TESTING.
offer maximum performance when tested and maintained in compliance with
NFPA 72. 10. Reconnect disabled circuits.
The sensor can be tested in the following ways: 11. Notify the proper authorities that the system is back on line.
A. Functional: Magnet Test (P/N M02-04-01 or M02-09-00) SPECIAL NOTE REGARDING SMOKE DETECTOR GUARDS
This sensor can be functionally tested with a test magnet. The test magnet Smoke detectors are not to be used with detector guards unless the combina-
electronically simulates smoke in the sensing chamber, testing the sensor tion has been evaluated and found suitable for that purpose.
electronics and connections to the control panel.
1. Hold the test magnet in the magnet test area as shown in Figure 3. FIGURE 3: FEATURES OF THE PHOTO DETECTOR
2. The sensor should alarm the panel. Magnet
Two LEDs on the sensor are controlled by the panel to indicate sensor Test Base Alignment Notch
Marker
status. Coded signals, transmitted from the panel, can cause the LEDs to
blink, latch on, or latch off. Refer to the control panel technical documen-
tation for sensor LED status operation and expected delay to alarm.
Base
B. Smoke Entry Alignment
Sensitivity readings are available through the FACP. Refer to the manufac- Notch
LED
turer’s published instructions for proper use.
Magnet Test Marker LED
Additionally, canned aerosol simulated smoke (canned smoke agent) may C2021-00
be used for smoke entry testing of the smoke detector. Tested and ap-
FIGURE 4: CLEANING THE PHOTO DETECTOR
proved aerosol smoke products are:
Manufacturer Model
Sensor Cover
HSI Fire & Safety 25S, 30S (PURCHECK)
SDi SMOKE CENTURIAN, SOLOA4,
SMOKESABRE, TRUTEST Sensing Chamber
No Climb TESTIFIRE 2000 Cover Cover and Screen
Removal
When used properly, the canned smoke agent will cause the smoke detec- Tabs Sensing Chamber
tor to go into alarm. Refer to the manufacturer’s published instructions for
proper use of the canned smoke agent.
C2022-00
CAUTION
Canned aerosol simulated smoke (canned smoke agent) formulas will vary SPECIAL APPLICATION
by manufacturer. Misuse or overuse of these products may have long term When configured at the fire alarm control panel, this detector is capable of op-
adverse effects on the smoke detector. Consult the canned smoke agent manu- erating in a special application mode such that it has a higher sensitivity than
facturer’s published instructions for any further warnings or caution statements. is normally allowed by UL 268 for areas where early warning is important. In
this mode, the detector does not comply with the Cooking Nuisance Smoke
A sensor that fails any of these tests may need to be cleaned as described Test. Detectors (Sampling ports) set to the special application mode are not
under CLEANING, and retested. suitable for use in areas where cooking appliances may be used. If cooking
When testing is complete, restore the system to normal operation and notify appliances are used within the protected space, a normal application detector
the proper authorities that the system is back in operation. or normal application mode must be used for that area.
Special application mode is not for general use and the detector may be more
CLEANING prone to false alarms if used in unsuitable environments. While no list is
Before removing the detector, notify the proper authorities that the smoke all-inclusive, some examples of unsuitable environments for special applica-
detector system is undergoing maintenance and will be temporarily out of tion mode are areas with airborne particulate or aerosols including sawing,
service. Disable the zone or system undergoing maintenance to prevent un- drilling, and grinding operations, textile or agricultural processing, or areas
wanted alarms. with engines that are not vented to the outside. A complete list of aerosol and
1. Remove the sensor to be cleaned from the system. particulate sources is available in the Annex of NFPA 72.
2. Remove the sensor cover by pressing firmly on each of the four removal Suitable environments for special application mode could include early warn-
tabs that hold the cover in place. (See Figure 4.) ing for hospitals, museums, assisted living and other areas that do not have
3. Vacuum the screen carefully without removing it. If further cleaning is airborne particulate or aerosols.
required continue with Step 4, otherwise skip to Step 7. Refer to the fire alarm control panel documentation for information on how to
4. Remove the chamber cover/screen assembly by pulling it straight out. configure the detector for special application mode.
5. Use a vacuum cleaner or compressed air to remove dust and debris from
the sensing chamber.

Please refer to insert for the Limitations of Fire Alarm Systems


FCC STATEMENT DEVICE AND SYSTEM SECURITY
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, Before installing this product ensure that the
and (2) this device must accept any interference received, including interference that may cause undesired operation. tamper seal on the packaging is present and
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits unbroken and the product has not been tampered
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio with since leaving the factory. Do not install this
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there product if there are any indications of tampering.
is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, If there are any signs of tampering the product
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following should be returned to the point of purchase.
measures: It is the responsibility of the system owner to
– Reorient or relocate the receiving antenna. ensure that all system components, i.e. devices,
– Increase the separation between the equipment and receiver. panels, wiring etc., are adequately protected to
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. avoid tampering of the system that could result
– Consult the dealer or an experienced radio/TV technician for help. in information disclosure, spoofing, and integrity
violation.
Honeywell® is a registered trademark of Honeywell International, Inc.
Preliminary 2 I56-6531-001
©2019 Honeywell. 09/23/2019
IDP-CONTROL
Addressable Notification Module
The IDP-CONTROL is an addressable notification module for use with
Honeywell Farenhyt Series fire alarm control panels (FACPs). The IDP-
CONTROL gives you the flexibility to add notification circuits wherever
they are needed on an Farenhyt FACP signaling line circuit (SLC) loop.

The IDP-CONTROL provides supervised monitoring of wiring to load


devices that require an external power supply to operate, such as bells,
horns, and strobes. It is capable of Class B and Class A supervision.

Upon command from the FACP, the IDP-CONTROL will disconnect the
supervision and connect the external power supply across the load device.
The disconnection of the supervision provides a positive indication to the
IDP-CONTROL
panel that the control relay actually turned on. The external power supply
is always relay isolated from the SLC loop, so that a trouble condition
on the power supply will never interfere with the rest of the system.

INSTALLATION
The IDP-CONTROL mounts directly into a 4” square electrical box. The
box must have a minimum depth of 2-1/8”. A surface mount electrical
box (System Sensor® PN SMB500) is available from Honeywell.

COMPATIBILITY
The IDP-CONTROL is compatible with the following Farenhyt Series FACPs:

• IFP-2100 / IFP-2100ECS / RFP-2100


• IFP-2000 / IFP-2000ECS / RPS-2000
• IFP-1000 / IFP-1000ECS
• IFP-300 / IFP-300ECS
• IFP-100 / IFP-100ECS
• IFP-75
• IFP-50
F E AT U R E S & B E N E F I T S
• Flexible solution for • Polling LED visible • MEA Listed 386-02-E
adding notification through the cover Vol. II
circuits where needed plate
• Support for Class B • Rotary address
(style Y) or Class A switches for fast
(style Z) wiring installation
• Panel controlled • SEMS screws for easy
status LED that wiring
flashes green in
• UL Listed
normal state and is
solid red in alarm • CSFM Listed
IDP-CONTROL Technical Specifications
For a complete listing of all
PHYSICAL compliance approvals and
certifications, please visit
Dimensions: 4.5" H x 4"W x 1.25" D www.farenhyt.com.
Shipping Weight: 6.3oz (196g)
Microsoft, Windows, and
ELECTRICAL RATINGS the Windows Logo are
registered trademarks
Operating Voltage: 15 to 32VDC or trademarks of
Standby & Alarm Current: 350 μA Microsoft Corporation.
End-of-Line Resistance: 47kW
Honeywell® and
SLC Loop Impedance: 40W System Sensor® are
registered trademarks
ENVIRONMENTAL of and Farenhyt™ is a
Operating Temperature: 32º-120ºF (0ºC – 49ºC) trademark of Honeywell
International, Inc.
Humidity: 10 to 93% non-condensing)
This document is not
ORDERING INFORMATION intended to be used for
installation purposes. We
IDP-CONTROL: Notification module
try to keep our product
information up-to
ACCESSORIES date and accurate. We
SMB500: 4” Square Surface Mount Electrical Box cannot cover all specific
CB500: Module Barrier. Used to separate power applications or anticipate
all requirements. All
limited and non-power limited wiring in a junction
specifications are subject
box. to change without notice.

For Technical
Support, Please call
800-446-6444.

For more information


Learn more about Honeywell’s Farenhyt Series
and other products available by visiting
www.farenhyt.com

Honeywell Security & Fire


12 Clintonville Road
Northford, CT 06472 Doc 350293 | Rev H | 12/17
800-328-0103 © 2017 Honeywell International Inc.
IDP-MONITOR-2
Addressable Dual Monitor Module
The IDP-MONITOR-2 is an addressable monitor module with two initiating
circuits for use with Honeywell Farenhyt Series fire alarm control panels
(FACPs). The IDP-MONITOR-2 acts as an interface to contact devices,
such as waterflow switches and pull stations.

The IDP-MONITOR-2 supports Class B supervised wiring to the load device.


Conventional 4-wire smoke detectors can be monitored for alarm and
trouble conditions.

Because the IDP-MONITOR-2 is capable of monitoring two separate Class


B circuits, it is ideal for waterflow tamper switch and flow switch monitoring.

IDP-MONITOR-2
Installation
The IDP-MONITOR-2 mounts directly into a 4” square electrical box. The
box must have a minimum depth of 2-1/8”. A surface mount electrical box
(System Sensor® PN SMB500) is available from Honeywell.

COMPATIBILITY
The IDP-MONITOR-2 is compatible with the following Honeywell Farenhyt
Series FACPs:

• IFP-2100 / IFP-2100ECS / RFP-2100

• IFP-2000 / IFP-2000ECS / RPS-2000

• IFP-1000 / IFP-1000ECS

• IFP-300 / IFP-300ECS

• IFP-100 / IFP-100ECS

• IFP-75

• IFP-50

F E AT U R E S & B E N E F I T S
• Monitor two circuits, • Panel controlled • SEMS screws for easy • CSFM Listed
with unique status LED that wiring
• MEA Listed 457-99-E
addresses, flashes green in
• UL Listed Vol. V
simultaneously normal state and is
solid red in alarm
• Support for Class B
wiring • Rotary address
switches for fast
• Fully supervised
installation
IDP-Monitor-2 Technical Specifications
For a complete listing of all
compliance approvals and
certifications, please visit
www.farenhyt.com.

Microsoft, Windows, and


the Windows Logo are
registered trademarks
or trademarks of
Microsoft Corporation.

Honeywell® and
System Sensor® are
registered trademarks
of and Farenhyt™ is a
trademark of Honeywell
International, Inc.

This document is not


intended to be used for
installation purposes. We
try to keep our product
information up-to
date and accurate. We
cannot cover all specific
applications or anticipate
Typical Wiring for IDP-Monior-2 Module, NFPA Style B all requirements. All
specifications are subject
to change without notice.

For Technical
Support, Please call
PHYSICAL ORDERING INFORMATION 800-446-6444.
Dimensions: 4.5" H x 4" W x 1.3 D ( 11.4 x 10.2 x IDP-MONITOR-2: Dual Monitoring Module
3.2cm)
Shipping Weight: 6.3oz (196g) ACCESSORIES
SMB500: 4” Square Surface Mount Electrical Box
ELECTRICAL RATINGS
Operating Voltage: 15 – 32VDC
Maximum Current Draw: 6.4mA (LED on)
SLC Standby & Alarm Current: 750μA max @ 24
VDC (one communication every sec with 47k EOL)
End of Line Resistance: 47kW

ENVIRONMENTAL
Operating Temperature: 32º-120ºF (0ºC – 49ºC)
Humidity: 10 to 93% non-condensing)

For more information


Learn more about Honeywell’s Farenhyt Series and
other products available by visiting
www.farenhyt.com

Honeywell Security & Fire


12 Clintonville Road
Northford, CT 06472 Doc 350289 | Rev G| 11/17
800-328-0103 © 2017 Honeywell International Inc.