1. PRODUCT CATALOGUE 3
2. PREVIOUS APPROVAL 79
3. WARRANTY CERTIFICATE 99
• Farenhyt Positioning
3nd Largest
brand in USA
First digital alarm First power Farenhyt FAS series Bought by Q1’2018
communicator expander for launched 1998 Honeywell Branding Change and
and receiver 1970 hungry new ADA 2000 Next Generation of Product
notification appliances
1993
• Disney Studios
• Bausch & Lomb
IFP-75B (Black)
IFP-75 (Red)
• 9A Power Supply
© 2016 by Honeywell International Inc. All rights reserved.
RFP-2100 / RFP-2100B
• Panel supports up to 2100 Points (159 sensors/159 devices per loop). All points can be sensors
• 9A Power Supply
SLC
SLC Expander
Repeater Panel
Note: 6815 expanders donot have predefined device count limit (63 Total SBUS Devices).Limit
© 2016 by Honeywell International Inc. All rights reserved.
IFP-2100 / IFP-2100B / RFP-2100 / RFP-2100B Overview
Key Features
# of SBUS 2 2
SBUS Backwards Y Y
Compatibility
Display 160-Char (4x40) N/A
Char Display
Company Internal Honeywell Confidential © 2017 by Honeywell International Inc. All rights reserved.
IFP-2100ECS / IFP-2100ECSB- Addressable Fire Alarm Control Panel and
Emergency Communication System
• Panel supports up to 2100 Points (159 sensors/159 devices per loop)
• Additional SLC can be added by 6815 cards
• Available in Red or Black cabinet
• 4 Line x 40 Character LCD display
• Two SBUSs
• Can be networked up to 32 panels via SK-NIC (network card)
• Support copper network, Single mode, Multimode fiber
connection option
• Eight FlexPuts
• 9A Power Supply
Key Features
IFP-2100ECS
Panel
IFP-2100ECSB
Addressable SLC Points 2100
# of Amplifiers 16
Networking
Copper Cable
Building 1 Building 2
Twisted Pair Copper Wire - must use the SK-NIC to provide up to 3000 feet of separation.
Building 1 Building 2
Fiber Optic Single Mode - must use the SK-NIC and SK-FSL for up to 30dB loss of signal separation. SKFSL
connects to the network using 9/125 micron single-mode fiber
Building 1 Building 2
Fiber Optic Multi-Mode - must use the SK-NIC and SK-FML for up to 8dB loss of signal separation. SKFML
connects to the network using 62.5/125 micron multi-mode fiber
WIDP-PULL-DA
WIDP-PULL-SA
WIDP-MONITOR WIDP-RELAY
MESH Network
WIDP-WGI
24VDC
Gateway is wired on the SLC loop
Conventional Sounder WIDP-RELAY
• Provides life safety detection for fire and CO with one device
- Uses Photoelectric, Heat, Light/Flame and CO to detect fire and significantly
reduce nuisance alarms
- Uses electrochemical sensor to detect carbon monoxide as a separate alarm
• Better Together
- Saves installation time and money
- Improves room aesthetics
• Plug In Design
• Plug In Design
* Always use the SBUS device calculator to confirm current draw and cable distance
* Always use the SBUS device calculator to confirm current draw and cable distance
• Mounting Options
- RPS-1000 Cabinet can mount 2 x 6815 SLC Expander
Parallel
RS-232
5880
• Flush mountable
IFP-2100 RPS-1000
6815XL
Fiber SK-F485C
SK-F485C
• 4 programmable circuits
- NAC (Notification Appliance Circuit)
- Constant Power
- Resettable Power
- Door Holder Power
- Sounder Base Power
6000 ft
6000 ft
Emergency Communications
• Can be mounted upto 6000Ft away from ECS Series panel and can be
conveniently located near the area of protection to reduce wiring
demands
ECS FACP ECS-50W
• Six wire connection to ECS System: Two wires for the voice bus and
SBUS
(4-conductor)
Four wires for the SBUS connections
VBUS
• Surface or Flush Mounted
(2-conductor
shielded)
• Available in Red or Black cabinet
• Can be mounted upto 6000Ft away from ECS Series panel and
can be conveniently located near the area of protection to
VBUS
reduce wiring demands
(2-conductor
shielded)
• Six wire connection to ECS System: Two wires for the voice
bus and Four wires for the SBUS connections
SBUS
(4-conductor)
Distributed Power!
VBUS
(2-conductor
shielded)
ECS-50W
VBUS
SLC 5895XL
ECS-CE4 6 Flexputs
ECS-125W
5496
ECS-CE4
4 NACs
ECS-LOC
5860
8 Flexputs
6815XL
SLC
The RA-2000 have the same height and flush mount depth as
the ECS-RPU so if the installation requires a fully functioning
LOC with annunciation the RA-2000 can be installed right next
RA-2000 ECS-RCU
to the ECS-RPU for a sleek installation which meets UL requirements
for LOC
© 2016 by Honeywell International Inc. All rights reserved.
65
Company Internal
Ordering Parts
• IFP-NET-3: Software and key (a key is required on each PC in system)
IFT-FFT
BACNET / Modbus
IFP-NET-3 Graphical
Monitoring Software
Gas Detection/
Flame Detection
© 2016 by Honeywell International Inc. All rights reserved.
S'
...j-..I-...--+
6]u-bqJl
a{atr6^€l
@ oLr.oJl ^z'
rr,rot- c6t5o.ry
.i!i rel & *,r i;lriJl &lS J..3r )pt $ t- 6+ r.-+ r6,s :J;liJl q^i
:tr-ill Jr! a-l
e r
'- ,Elr
"-_!t
.,rJ.ia-Y! cru
:,rtiLi:-Yl
r; lctidul ($r dj,.]l c,l-Jlj6jl 'iiL rlull {- isJti +Jii (HoN EY WELL) BY (farenhyt } .SJU ,j,J-ll Jlsl atln jt irl ;). eili
. lii.ll ...,.s SLD !!i. J+! C ul els !l.l,ll {i}!illr 3t+lll Jrl.rr. r 1-1-)"i,.11
ar-j-5ll lirl rr. iir- uLJl tukjJ { '-t n {i diii -1
r.1!l g" 4rt')l J"J.JI pp6 -l
e l eli.)ll e.I'ijl .rj. K.1-3
Project Name:ABHA Executive office extension and rehabilitation Contractor: Bashaer Al-benaa Contracting Co
Submittal Description:
BRAND: HONEYWELL
This letter is to state that Honeywell owns and operates factories in over 30 countries. Products are
manufactured under the brand name and logo of Honeywell Corporation in USA, Italy, United Kingdom,
Mexico, Canada, Japan, Korea, Taiwan, China, Australia, South Africa, Switzerland and the Netherlands.
Honeywell hereby confirms that all Honeywell brand products have been tested and in accordance by our
Global Quality Assurance Department under the direct control and leadership of our USA Head quarters to
ensure the products Quality and Performance.
The Standard warranty for Honeywell Farenhyt Fire Alarm is Three years against manufacturing defects from
the date of manufacture. Please reach out to the undersigned for any clarifications
Yours sincerely,
Jabri, Fahmi
Strategy and Marketing Director, Honeywell Security and Fire
Dated: 15 Oct 2018 Reference No. S/2018/146
This letter is to state that Honeywell owns and operates factories in over 30 countries. Products are
manufactured under the brand name and logo of Honeywell Corporation in USA, Italy, United Kingdom,
Mexico, Canada, Japan, Korea, Taiwan, China, Australia, South Africa, Switzerland and the Netherlands.
Honeywell hereby confirms that all Honeywell brand products have been tested and in accordance by our
Global Quality Assurance Department under the direct control and leadership of our USA Head quarters to
ensure the products Quality and Performance.
Further, Honeywell manufactures the following list of products in the countries as listed across it only:
Farenhyt 2100 point Addressable Fire Panel, 4 line LCD display with 40
characters per line, One SLC loop card inbuild, 159 Detectors and 159
Modules per loop, Additional Loop cards can be expanded through
USA
5815RMK (Remote mounting Kit which accomodates 2 SLC Cards (6815)),
Network upto 32 panels, inbuild eight on-board Flexput™ circuits,Built in
USB interface,for programming,Four programmable function keys,
IFP-2100HV 240VAC @ 50/60Hz, 2.8A , UL Listing and FM Approved, Black Cabinet
6815 SLC Loop Expander which supports 159 Detectors and 159 Modules USA
5815RMK Remote Mounting Kit USA
SK-NIC Network Interface Card USA
SK-FSL Network Interface Card USA
BAT-12550 BATTERY, 12 VOLT, 55 AH. VIETNAM
BATTERY BOX, HOLDS UP TO TWO BAT-12260 (26 AH) OR BAT-12550 (55
USA
BB-55F AH)
ECS- Amplifier 50/100 Watt Dual Channel / Back-up Amp -high Voltage 220vac USA
DUAL50WHV 50 Hz
BAT-12180-BP TWO (2) BAT-12180 (12V, 18AH) SHIPPED IN EACH BULK PACK VIETNAM
IFP-NET-3 Software and key (a key is required on each PC in system) USA
Installation packages includes Gateway interface, Cabinet, and 5824 USA
IFPN-GW-KIT Serial/Parallel printer interface
RA-2000 4 X 40 Display Remote Annunciator. Red USA
IDP-PHOTO Intelligent Addressable Photoelectric Detector MEXICO
B501 4" Mounting Base MEXICO
Intelligent Sounder Base High/low Volume Output W/ansi Temporal 3 Or MEXICO
B200S Temporal 4, Continuous, March Or Custom Tone
IDP-FIRE-CO Advanced Multi-Criteria Fire/CO Detector ITALY
RA100Z Remote LED. Mounts to single gang box. MEXICO
IDP-PULL-DA Addressable Manual Dual Action Pull Station MEXICO
Intelligent Photoelectric Replacement Smoke Detector remote test MEXICO
IDP-PHOTOR capable, for use with DNR (W) duct smoke detector
DNR InnovairFlex intelligent duct detector, non-relay, does not include head MEXICO
ST-5 Detector sampling tube, 4-8’ ducts MEXICO
P48-21-00 Replacement End Cap for Metal USA
RTS151KE Key-Activated Remote Test station MEXICO
IDP-BEAM Intelligent Addressable Beam Smoke Detector MEXICO
BEAMMMK Projected Beam Smoke Detector Multi-Mount Kit, Wall or Ceiling. MEXICO
BEAMLRK Projected Beam Smoke Detector Long Range Kit, Increases Distance. DE
RTS151 Remote Test Station. MEXICO
Intelligent Addressable Multicriteria Photoelectric Smoke Detectorc MEXICO
IDP-ACCLIMATE (Smoke with Thermal (Base Not Included)
9400X FAAST XT 4 CHANNEL MEXICO
761520.10 Pipe (ABS), length 3 m, 25 mm PU 10 pcs. Total 30 mts GREAT BRITAIN
761525.10 Sleeve (ABS) for 25 mm pipe PU 10 pcs. GREAT BRITAIN
761523.10 45° angle (ABS) for 25 mm PU 10 pcs. GREAT BRITAIN
761522.10 90° angle (ABS) for 25 mm PU 10 pcs. GREAT BRITAIN
761526.10 End cap (ABS) for 25 mm pipe PU 10 pcs. GREAT BRITAIN
761542.10 Suctions hose set for 25 mm GREAT BRITAIN
761524.10 T-piece (ABS) for 25 mm pipe PU 10 pcs. GREAT BRITAIN
IDP-CONTROL Addressable Control Module MEXICO
Intelligent Addressable Thermal Detector Fixed Temp 135 (Base Not MEXICO
IDP-HEAT Included)
Intelligent Addressable Fixed temperature and rate-of rise thermal MEXICO
IDP-HEAT-ROR detector (Rate-of-rise detection 15ºF/min (9ºC/min) (Base Not Included)
Intelligent Sounder Base High/low Volume Output W/ansi Temporal 3 Or MEXICO
B200S Temporal 4, Continuous, March Or Custom Tone
FSL100-UV UVIR flame detector RED, ATEX FM EN54 NETHERLANDS
S2000A Sensor cable MEXICO
Yours sincerely,
Jabri, Fahmi
Strategy and Marketing Director, Honeywell Security and Fire
S.No. Description Model No. QTY
FARENHYT BY HONEYWELL
Farenhyt 2100 point Addressable Fire Panel, 4 line, LCD display with 40
characters per line, One SLC, loop card in build, 159 Detectors and 159 Modules,
per loop, Additional Loop cards can be expanded, through 5815RMK (Remote
1 mounting Kit which, accommodates 2 SLC Cards (6815)) , Network upto, 32 HONEYWELL#IFP-2100HV 1
panels, in build eight on-board Flexput™, circuits, Built in USB interface for
programming, Four programmable function keys,
240VAC @ 50/60Hz, 2.8A , UL Listing and FM, Approved, Red Cabinet
4 X 20 Display Remote Annunciator (80-character
backlit LCD display ).Red, Larger keypad buttons
for system reset and silence , Five status LEDs for
2 HONEYWELL#RA-1000R 1
alarms, supervisory, trouble, silence and AC power
indications, Activated by user code or fire fighter
key
F E AT U R E S & B E N E F I T S
• RFP-2100 or • Four line LCD display • Network card allows • JumpStart • Supports up to four
RFP-2100B can be with 40 characters per copper network AutoProgramming® SWIFT wireless
used in a networked line connection with a feature for easy gateways. Each
system where at lease multi-mode or programming gateway can have up
• Available in a red or
one IFP-2100 is in the single-mode fiber to 49 wireless devices
black cabinet • Renewable license on
system connection option
downloading software • Supports Class B
• IFP-2100 or
• Network support for • Built-in dual phone helps inhibit (Style 4) and Class A
RFP-2100 can be
up to 32 Sites line, digital alarm unauthorized (Style 6 or Style 7
surface or flush
communicator/ programming configuration for SLC,
• Built-in support for up mounted
transmitter (DACT), IP and SBUS.
to 159 IDP/SK • Firmware can be
• Four programmable or optional cellular
detectors and 159 upgraded in the field • Built in USB interface
function keys technologies
IDP/SK modules or for programming
127 SD SLC devices
IFP-2100 / RFP-2100 Technical Specifications
SPECIFICATIONS ORDERING INFORMATION For a complete listing of all
Physical: IFP-2100 - Intelligent Fire Alarm Control Panel. compliance approvals and
certifications, please visit
Overall Dimensions: 26.4” H x 16.4" W x 4.11” D Red
www.farenhyt.com.
Weight: 45 lbs. IFP-2100B - Intelligent Fire Alarm Control
Color: Red or Black Panel. Black Microsoft, Windows, and
RFP-2100 - Remote Fire Alarm Panel without the Windows Logo are
Environmental Operating Temperature: 32°F to registered trademarks
120°F (0°C to 49°C) built in display. Red
or trademarks of
Humidity: 0 to 93% relative humidity (non- RFP-2100B - Remote Fire Alarm Panel without Microsoft Corporation.
condensing) built in display. Black
All other trademarks
SBUS ACCESSORIES are the property of their
ELECTRICAL: respective owners.
IFP-2100 Primary AC: 120 VAC @ 50/60 Hz, 5.0A RA-2000, RA-1000, RA-1000R, RA-100,
Total Accessory Load: 9A @ 24 VDC power-limited RA-2000GRAY - Remote annunciator. Four Line This document is not
LCD with 40 characters per line intended to be used for
Standby Current: 230 mA installation purposes. We
6815 - Signal Line Circuit (SLC) Expander for
Alarm Current: 415 mA try to keep our product
IDP/SK devices information up-to
Battery Charging Capacity: 17 to 55 AH
5815XL - Signal Line Circuit (SLC) Expander for date and accurate. We
Battery Size: 18 AH max. allowed in control panel SD devices cannot cover all specific
cabinet. Larger capacity batteries can be housed in applications or anticipate
RPS-1000 - Power Supply
RBB accessory cabinet. all requirements. All
5496 - NAC Expander
Six Conductor Wiring: Two voice bus & four SBUS specifications are subject
5824 - Serial/Parallel Module to change without notice.
FLEXPUT CIRCUITS 5880 - LED I/O Module
For Technical
Eight circuits that can be programmed 5865-3/-4 - LED Annunciator
Support, Please call
individually as: 5883 - Relay Interface 800-446-6444.
Notification Circuits: 3A per circuit @ 24 VDC,
power limited MISCELLANEOUS ACCESSORIES
Auxiliary Power Circuits: 3A per circuit @ 24 VDC, SKSS-3 - Software Suite. Provides
power limited. programming, upload/download and event
reporting
Initiation Circuit: 100 mA per circuit @ 24 VDC,
power-limited RBB - Remote Battery Box Cabinet. Use for
backup batteries up to 35 AH. Dim: 16" W x 10"
APPROVALS H x 6" D
NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA SK-SCK - Seismic Compliance Kit
72: Central Station; Remote Signalling; Local SK-NIC - Network Interface Card
Protective Signalling Systems; Auxiliary Protected SK-FML - Multi Mode Fiber Card
Premises Unit; & Water Deluge Releasing Service SK-FSL - Single Mode Fiber Card
Other Approvals: CELL-MOD - Cellular Communicator in Plastic
UL Listing; CSFM (pending); COA (pending); Enclosure
OSHPD (CA) (pending), FM (pending) CELL-CAB-SK - Cellular Communicator in
Metal Enclosure with lock and key
APPROVED RELEASING SOLENOIDS
Asco T8210A107 24 VDC 3 A max 0 Hz
Asco 8210G207 24 VDC 3 A max 0 Hz
COMPATIBLE DEVICES
See the data sheets listed below for a complete
listing of the IDP, SK, SWIFT or SD devices.
350361 - IDP Device Protocol data sheet
53623 - SK Device Protocol data sheet
350360 - SD Device Protocol data sheet
350615 & 350617 - SWIFT devices data sheet
Honeywell
12 Clintonville Road
Northford, CT 06472
800-328-0103 Doc 351602| Rev A | 01/17
www.farenhyt.com © 2017 Honeywell International Inc.
RA-1000 / RA-1000R
Remote Annunciator
The RA-1000 is a remote annunciator used to operate and program
IFP-series fire alarm control panels (FACP's). The RA-1000’s keypad and
display match the built-in annunciator of the IFP-1000 control panel.
The remote annunciator connects to the control panel via the RS-485
system bus. When the system is in normal operation and has AC power, the
Power LED is lit and all other LEDs are off. The other LEDs turn on as
alarms, supervisories, troubles, system silenced and AC power losses occur.
INSTALLATION
The RA-1000 can be surface or flush mounted. Use the optional trim ring
for surface mounts. When flush mounting an electrical box is optional. If RA-1000R /RA-1000
using an electrical box, use a 4S, single-gang, or double-gang box.
COMPATIBILITY
The RA-1000 is compatible with the following Farenhyt Series FACPs:
• IFP-2100 / IFP-2100ECS
• IFP-1000/ECS
• IFP-100/ECS
• IFP-300 / IFP-300ECS
• IFP-75
• IFP-50
F E AT U R E S & B E N E F I T S
• 80-character backlit • Initiate and end fire • Five Status LEDs for; • Support for
LCD display (4 lines drills with a single key alarms, supervisory, simultaneous use of
with 20 characters on press trouble, silence and AC multiple RA-1000s
each line) power indications
• View current status by • Wiring lengths up to
• Tactile/audible alarms, supervisories, • Available in red or gray 6000 ft. from the
feedback or troubles color FACP (depending on
wire gauge and
• RS-485 SBUS • On-board piezo • UL listed, complies
number of devices on
interface to panel sounder audibly with NFPA 72
SBUS)
indicates alarms,
• Larger keypad buttons • Accepts user codes or
troubles, and
for system reset and fire fighter’s key
supervisories
silence
RA-1000 Technical Specifications
For a complete listing of all
compliance approvals and
certifications, please visit
www.farenhyt.com.
Honeywell® is a
registered trademarks
of and Farenhyt™ is a
trademark of Honeywell
International, Inc.
For Technical
SPECIFICATIONS ORDERING INFORMATION Support, Please call
Dimensions: 9.1”W x 7.4”H x 1.5”D (23.1W x 18.8H x RA-1000R: Remote Annunciator. Four line LCD 800-446-6444.
3.8D cm) annunciator with 20 characters per line. Red.
RA-1000: Remote Annunciator. Four line LCD
ENVIRONMENTAL annunciator with 20 characters per line. Gray.
Operating Temperature: 32°F to 120°F (0°C to
49°C) OPTIONAL ACCESSORIES
Humidity: 10% to 93% relative humidity (non- 5860TR: Red Trim Ring. For surface mounting.
condensing) 5860TG: Gray Trim Ring. For surface mounting.
I56-6531-001
Farenhyt® Series Black
clude:
Control Panel
1. The sensor’s LEDs can operate in three ways—on, off, and blinking–and + + + +
2
+ +
2
2 – – –
they can be set to red, green, or amber. This is controlled by the panel. RA
1
RA
3
1
RA
1
3 3
2. The remote output may be synchronized to the LED operation or con-
trolled independent of the LEDs.
3. Devices are point addressable up to 159 addresses. (–)
Please refer to the operation manual for the UL listed control panel for specific (–) CLASS A OPTIONAL WIRING
operation. The photoelectric sensors require compatible addressable com- (+)
munications to function properly. Connect these sensors to listed-compatible
C0129-10
control panels only. TAMPER-RESISTANCE
Intelligent photoelectric smoke sensors include a tamper-resistant capability
SPACING that prevents their removal from the base without the use of a tool. Refer to
Honeywell recommends spacing sensors in compliance with NFPA 72. In low the base manual for details on making use of this capability.
air flow applications with smooth ceilings, space sensors 30 feet apart (9.1 m).
For specific information regarding sensor spacing, placement, and special ap-
plications, refer to NFPA 72 or the System Smoke Detector Application Guide,
available from Honeywell.
Duct Applications: IDP-PHOTO-W and IDP-PHOTO-IV are listed for use in
ducts. See Duct Smoke Detectors Applications Guide HVAG53 for details on pen-
dant mount applications. NOTE: Intelligent photoelectric smoke sensors are
also listed for use inside DNR(W) duct smoke detectors.
Preliminary 1 I56-6531-001
09/23/2019
TESTING 6. Reinstall the chamber cover/screen assembly by sliding the edge over the
Before testing, notify the proper authorities that the system is undergoing sensing chamber. Turn until it is firmly in place.
maintenance, and will temporarily be out of service. Disable the system to 7. Replace the cover using the LEDs to align the cover and then gently push-
prevent unwanted alarms. ing it until it locks into place.
All sensors must be tested after installation and periodically thereafter. Test- 8. Reinstall the detector.
ing methods must satisfy the Authority Having Jurisdiction (AHJ). Sensors
9. Test the detector as described in TESTING.
offer maximum performance when tested and maintained in compliance with
NFPA 72. 10. Reconnect disabled circuits.
The sensor can be tested in the following ways: 11. Notify the proper authorities that the system is back on line.
A. Functional: Magnet Test (P/N M02-04-01 or M02-09-00) SPECIAL NOTE REGARDING SMOKE DETECTOR GUARDS
This sensor can be functionally tested with a test magnet. The test magnet Smoke detectors are not to be used with detector guards unless the combina-
electronically simulates smoke in the sensing chamber, testing the sensor tion has been evaluated and found suitable for that purpose.
electronics and connections to the control panel.
1. Hold the test magnet in the magnet test area as shown in Figure 3. FIGURE 3: FEATURES OF THE PHOTO DETECTOR
2. The sensor should alarm the panel. Magnet
Two LEDs on the sensor are controlled by the panel to indicate sensor Test Base Alignment Notch
Marker
status. Coded signals, transmitted from the panel, can cause the LEDs to
blink, latch on, or latch off. Refer to the control panel technical documen-
tation for sensor LED status operation and expected delay to alarm.
Base
B. Smoke Entry Alignment
Sensitivity readings are available through the FACP. Refer to the manufac- Notch
LED
turer’s published instructions for proper use.
Magnet Test Marker LED
Additionally, canned aerosol simulated smoke (canned smoke agent) may C2021-00
be used for smoke entry testing of the smoke detector. Tested and ap-
FIGURE 4: CLEANING THE PHOTO DETECTOR
proved aerosol smoke products are:
Manufacturer Model
Sensor Cover
HSI Fire & Safety 25S, 30S (PURCHECK)
SDi SMOKE CENTURIAN, SOLOA4,
SMOKESABRE, TRUTEST Sensing Chamber
No Climb TESTIFIRE 2000 Cover Cover and Screen
Removal
When used properly, the canned smoke agent will cause the smoke detec- Tabs Sensing Chamber
tor to go into alarm. Refer to the manufacturer’s published instructions for
proper use of the canned smoke agent.
C2022-00
CAUTION
Canned aerosol simulated smoke (canned smoke agent) formulas will vary SPECIAL APPLICATION
by manufacturer. Misuse or overuse of these products may have long term When configured at the fire alarm control panel, this detector is capable of op-
adverse effects on the smoke detector. Consult the canned smoke agent manu- erating in a special application mode such that it has a higher sensitivity than
facturer’s published instructions for any further warnings or caution statements. is normally allowed by UL 268 for areas where early warning is important. In
this mode, the detector does not comply with the Cooking Nuisance Smoke
A sensor that fails any of these tests may need to be cleaned as described Test. Detectors (Sampling ports) set to the special application mode are not
under CLEANING, and retested. suitable for use in areas where cooking appliances may be used. If cooking
When testing is complete, restore the system to normal operation and notify appliances are used within the protected space, a normal application detector
the proper authorities that the system is back in operation. or normal application mode must be used for that area.
Special application mode is not for general use and the detector may be more
CLEANING prone to false alarms if used in unsuitable environments. While no list is
Before removing the detector, notify the proper authorities that the smoke all-inclusive, some examples of unsuitable environments for special applica-
detector system is undergoing maintenance and will be temporarily out of tion mode are areas with airborne particulate or aerosols including sawing,
service. Disable the zone or system undergoing maintenance to prevent un- drilling, and grinding operations, textile or agricultural processing, or areas
wanted alarms. with engines that are not vented to the outside. A complete list of aerosol and
1. Remove the sensor to be cleaned from the system. particulate sources is available in the Annex of NFPA 72.
2. Remove the sensor cover by pressing firmly on each of the four removal Suitable environments for special application mode could include early warn-
tabs that hold the cover in place. (See Figure 4.) ing for hospitals, museums, assisted living and other areas that do not have
3. Vacuum the screen carefully without removing it. If further cleaning is airborne particulate or aerosols.
required continue with Step 4, otherwise skip to Step 7. Refer to the fire alarm control panel documentation for information on how to
4. Remove the chamber cover/screen assembly by pulling it straight out. configure the detector for special application mode.
5. Use a vacuum cleaner or compressed air to remove dust and debris from
the sensing chamber.
Upon command from the FACP, the IDP-CONTROL will disconnect the
supervision and connect the external power supply across the load device.
The disconnection of the supervision provides a positive indication to the
IDP-CONTROL
panel that the control relay actually turned on. The external power supply
is always relay isolated from the SLC loop, so that a trouble condition
on the power supply will never interfere with the rest of the system.
INSTALLATION
The IDP-CONTROL mounts directly into a 4” square electrical box. The
box must have a minimum depth of 2-1/8”. A surface mount electrical
box (System Sensor® PN SMB500) is available from Honeywell.
COMPATIBILITY
The IDP-CONTROL is compatible with the following Farenhyt Series FACPs:
For Technical
Support, Please call
800-446-6444.
IDP-MONITOR-2
Installation
The IDP-MONITOR-2 mounts directly into a 4” square electrical box. The
box must have a minimum depth of 2-1/8”. A surface mount electrical box
(System Sensor® PN SMB500) is available from Honeywell.
COMPATIBILITY
The IDP-MONITOR-2 is compatible with the following Honeywell Farenhyt
Series FACPs:
• IFP-1000 / IFP-1000ECS
• IFP-300 / IFP-300ECS
• IFP-100 / IFP-100ECS
• IFP-75
• IFP-50
F E AT U R E S & B E N E F I T S
• Monitor two circuits, • Panel controlled • SEMS screws for easy • CSFM Listed
with unique status LED that wiring
• MEA Listed 457-99-E
addresses, flashes green in
• UL Listed Vol. V
simultaneously normal state and is
solid red in alarm
• Support for Class B
wiring • Rotary address
switches for fast
• Fully supervised
installation
IDP-Monitor-2 Technical Specifications
For a complete listing of all
compliance approvals and
certifications, please visit
www.farenhyt.com.
Honeywell® and
System Sensor® are
registered trademarks
of and Farenhyt™ is a
trademark of Honeywell
International, Inc.
For Technical
Support, Please call
PHYSICAL ORDERING INFORMATION 800-446-6444.
Dimensions: 4.5" H x 4" W x 1.3 D ( 11.4 x 10.2 x IDP-MONITOR-2: Dual Monitoring Module
3.2cm)
Shipping Weight: 6.3oz (196g) ACCESSORIES
SMB500: 4” Square Surface Mount Electrical Box
ELECTRICAL RATINGS
Operating Voltage: 15 – 32VDC
Maximum Current Draw: 6.4mA (LED on)
SLC Standby & Alarm Current: 750μA max @ 24
VDC (one communication every sec with 47k EOL)
End of Line Resistance: 47kW
ENVIRONMENTAL
Operating Temperature: 32º-120ºF (0ºC – 49ºC)
Humidity: 10 to 93% non-condensing)