AN5506-07 GPON Optical Network Unit User Manual (Version C) 365C

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

2 Equipment Mounting

4 Technical Specification
Wall mounting
Table_Product type and technical specifications

User Manual
Power Dimension
Type Weight (kg) Temperature (℃)
Consumption (W) (H×W×D) (mm)
AN5506-07-A 2.07 <25 43.5×440×190
AN5506-07-BH 2.35 <35 43.5×440×225 (with -30 to 55
AN5506-07 AN5506-07-BHD 2.37 <35 no mounting ears)

GPON Optical Network Unit 5 Description for Indicator LEDs


Code: MN000000365 Version: C
Indicator LED Color Status Description

Packing List ON The equipment is not working or is operating abnormally.


ACT Green Blinking The equipment is operating normally.
◆AN5506-07 × 1 ◆ Conformity certificate × 1 ◆ User manual × 1
OFF The equipment is not powered on.
◆DC Power Cable × 1 (AN5506-07BH/BHD) ◆ Earth ground cable × 1
ON One or more voice interfaces are off-hook.
◆AC Power Cable × 1 (AN5506-07A/BH/BHD) POTS Green
OFF No voice interface is off-hook.

Product Description PON Green


ON The registration on OLT is completed. Note:
OFF The registration on OLT is not completed.
The wall-mounting dimension for the AN5506-07-A is 360mm×100mm.
1 Product Introduction The receive optical power of the optical transceiver is below
ON
LOS Red the sensitivity value. According to the recess distance of the AN5506-07, install the four
The AN5506-07 GPON Optical Network Unit is an MDU (Multi-Dwelling Unit), Step1
providing Ethernet interface and telephone interface. Targeting at users in OFF The receive optical power of the optical transceiver is normal. mount-to-wall installation components provided in the AN5506-07
package on the wall.

1
residential communities and enterprises, the AN5506-07 GPON offers information, The port is connected to the user terminals without data

3 5
ON
communication and entertainment services, including data, voice and video. transmission.
Step2 Align the recesses on the AN5506-07’s bottom panel with the screws
Orange
(left) Blinking
The port is connected to the user terminals with data on the wall and fix them up gently.
FE1 to FE16 transmission.
OFF The port is not connected to the user terminals.
Step3 Take your hands off the AN5506-07 slowly and make sure the
equipment is mounted on the wall with the support of the screws.
Green ON The port is connected to the user terminals.
(right) OFF The port is not connected to the user terminals.

2 Product Types Product Installation


The AN5506-07 has three different types. The codes of the equipment vary with 1 Preparation Cabinet mounting
the voice interface and power supply mode. When unpacking the AN5506-07, please check that all items on the list are present
Table_Product types and interface quantities and not damaged. If any item is missing or has been damaged, please contact local
offices of FiberHome immediately.
Product Type Ethernet Interface Voice Interface Power Supply Mode
Before installing the AN5506-07, please read the following thoroughly.
AN5506-07-A 16 — AC
The installation location must be free of water, moisture and must be properly
AN5506-07-BH 16 16 (hybrid wiring mode) AC / DC
grounded for lightning protection.
AN5506-07-BHD 16 16 (dedicated interface mode) AC / DC
The selected installation position enables the connection between the AN5506-07
and the outside. For example, there should be sufficient outlet space for power
3 Product Functions cables and network cables.
The AN5506-07 supports the following functions: The installation position guarantees adequate air flow to facilitate heat dissipation.
Uses GPON uplink that is compliant with the ITU-T G.984 series of standards. The installation position provides good earth grounding conditions.
Supports IGMP Snooping and IGMP Proxy. 2 Equipment Mounting
Supports the STP / RSTP protocol.
The AN5506-07 can be secured on a stable plane like an office desk, mounted on
Supports the line loopback detection of Ethernet interfaces on the Client side.
the wall, or installed in a 19-inch / 21-inch cabinet.
Supports the DHCP Option82 to report the physical location information of the
Ethernet interface. Horizontal mounting
Supports the PPPoE+ function for the precise user identification.
Supports H.248, MGCP and SIP protocols, VBD mode fax/T.38 fax/MODEM
services and multiple coding modes including G.711,G.723 and G.729. Note:
Supports the configuration of Ethernet interface rates, working modes, Use the adaptor mounting ears to install the AN5506-07 in a 21-inch cabinet.
auto-negotiation mode and PAUSE flow control.
Supports IP address filtering in line with ACL rules to suppress unknown unicast, Step1 Take out the floating nuts and screws provided in the package. Install
broadcast and multicast messages. the floating nuts to the appropriate horizontal positions in the cabinet.
Supports L2 wire speed forwarding.

2 4 6
Supports the AES-128 algorithm for data encryption of downlink data in the Step2 Align the screw holes of the mounting ears on both sides of the
GPON system. AN5506-07 with the floating nuts and push them slowly until they are
Provides performance statistics on the Ethernet interfaces. Step1 Take out the AN5506-07 from the carton. Four self-adhesive pads are close to each other. Then install the screws into the screw holes of
Performs various QoS functions: supports global configuration of queue priority the floating nuts and tighten them.
attached to the four corners on the bottom of the device before delivery.
and flexible mapping of 802.1p value of packets.
Supports SP, WRR and SP+WRR scheduling modes: configures the weight of Step3 Take your hands off the AN5506-07 slowly and make sure the
Step2 Gently place the AN5506-07 on a stable surface that guarantees
the scheduling queue so as to guarantee the quality of VoIP, IPTV and other key ventilation on both the left and right sides. equipment is mounted in the cabinet with the support of the screws.
services when conducting multi-services.
Equipment Installation FAQs
3 Cable and Wire Connection Q: All indicator LEDs are extinguished after power-on.
A: 1) Check whether the power cable is correctly connected.
Fiber
AN55 Home
16-01
2) Check whether the power switch on the equipment’s front panel is in the
ON position.
Q: The equipment fails to work.
A: 1) If the equipment works abnormally, check whether the power is connected
External dry contact normally or the voltage is within specifications.
2) If the equipment is overheated, check the surroundings, the ventilation and
the fan.
OLT Q: The LOS indicator LED is ON.
Equipment grounding A: 1) Check the received optical power levels with an optical power meter.
ODN
Excessively low receive optical power may indicate the fiber is faulty.
ODF distribution frame 2) Check whether the optical fiber is connected normally to the appropriate interface.
3) The received optical power at the ONU exceeds the normal powerrange (the
optical power is too low or overload).
4) The ONU optical module is aged or damaged.
5) Check whether the equipment at the central office end is operating normally.
Q: PON indicator LED is OFF.
A: 1) The optical fiber connectors may not be securely connected. Check whether
the optical fibers are connected normally and whether the optical power is
below specifications;
2) The connectors may be dusty. Clean the connectors with cotton balls dampened
Hybrid with alcohol.
wiring mode 3) The ONU cannot register to the OLT or the registration fails, check the ONU

8
Dedicated authentication and authorization configuration.
interface mode
Q: POTS indicator LED is ON in on-hook state.
Data The 1st, 2nd A: 1) One or more POTS line is shorted. Check for shorted lines;;
3rd and 6th wires Voice
distribution frame 2) The fourth and fifth lines of the RJ-45 interface are voice signal lines and cannot
distribution frame be connected with computers of the opposite end. Otherwise, shorting will occur.
220V mains supply
The 4th
and 5th wires
The 7th and 8th wires

Brown 0V

Computer -48V
Blue DC
power supply
Yellow- / green
Telephone GND

Table_Voice cable wiring scheme


Computer Telephone Pin No. Wire Color User Side Interface Pin No. Wire Color User Side Interface
1 White 9 Red
1 9
35 Blue 43 Blue
2 White 10 Red
2 10
Table_ Definitions of the pins on the external dry 36 Orange 44 Orange
contact alarm socket 3 White 11 Red
3 11
37 Green 45 Green
RJ45 Pin No. Alarm Definition RJ45 Pin No. Alarm Definition
4 White 12 Red
4 12
1 Pin grounding 5 — 38 Brown 46 Brown
2 6 External alarm input 5 White 13 Red FiberHome Telecommunication Technologies Co., Ltd.
Battery capacity 0 5 13
39 Blue- / white 47 Blue- / white
3 — 7 Battery capacity1 Address: No. 6 Dongxin Rd., Hongshan Dist., Wuhan, China.
6 White 14 Red
Mains supply 6 14

7
4 8
Battery capacity 2 40 Orange- / white 48 Orange- / white Zip code: 430074
power-off alarm
7 White 15 Red
41 Green- / white
7
49 Green- / white
15 Website: http://www.fiberhomegroup.com
8 White 16 Red
8 16
42 Brown- / white 50 Brown- / white

You might also like