Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

STAUS:

F D
PRELIMINARY DESIGNED

2500 1st Floor FOR APPROVAL


DETAILED DESIGN
4.20 m AS BUILT

F
NOTE:
1. All DIMENSION ARE IN MILIMETERS
EXCEPT INDICATED.
2. ALL LEVELS ARE IN METER EXCEPT
INDICATED.
3. CHARACTERISTIC CYLINDER
COMPRESSIVE STRENGTH OF
CONCRETE SHALL BE MINIMIUM OF
35MPa AT 28DAYS.
1455 2545 4. REINFORCEMENT STELL YIELD
STRENGTH TO BE A MINIMUM OF
- 400MPa FOR DEFORM BAR (DB).
2500

2500
- 235MPa FOR ROUNDED BAR (RB).
5. CLEAR COVER SHALL BE 35mm

GF UNLESS INDICATED OTHERWISE.

1400
0.00 m
D
TOP PC
-0.50 m
1 GF Stair Layout 2 1st Flight
4 A111 SCALE (1 : 60)
3 A111 SCALE (1 : 60)

4 3
D F
1500 2500 1500
No. Description Date
1st Floor 1st Floor
4.20 m 4.20 m 2545 1455

313
156

B2 (20x40) B2 (20x40)
2800

2800
PROJECT:

GF GF Residential Building
1400

B2 (20x40)
0.00 m 0.00 m REFERENCE DRAWINGS

DRAWN BY Author

TOP PC TOP PC DESIGN BY Designer

-0.50 m 3 2nd Flight -0.50 m CHECK BY Checker

A111 SCALE (1 : 60) 4 3rd Flight


APPROVE BY Approver
A111 SCALE (1 : 60)
SHEET NAME:

GF Stair Layout

SIZE: A3 DATE: 06/05/23

SHEET No: A111 TOTAL SHEET