4000110

09.2017

TA-Slider 750/1250
TA-Slider 750/1250 Plus

1
0°C - +50°C 32°F - +122°F (5-95%RH, non-condensing)

 0°C - +120°C 32°F - +248°F

-20°C - +70°C -4°F - +158°F (5-95%RH, non-condensing)

Input signal: 0-10 VDC


Output signal: 0-10 VDC
Speed: 3 s/mm (3, 4, 6, 8, 12 or 16 s/mm)
76.2 s/in (76.2, 101.6, 152.4, 203.2, 304.8 or 406.4 s/in)
Characteristic: Linear

C las s III EN 61000-4-5

Pollution degree 3 C ateg. 3 IEC 60730

230V 24V EN 60730


Plus version Plus version
with Relay without Relay

TA-Slider 750/1250 TA-Slider 750/1250 Plus


5.5”

8.3”
5.5”

8.2” 4.9”
11.3”
10.3”

0.3” 0.3”
2” 2”

13

IP54

2
M8 x 25
Max. 10 Nm
(88.5 in-lb)

1. 2.

 

3.

Click + 

3
100-240 V Example!

Off

TA-Slider 750/1250 TA-Slider 750/1250 Plus


24 V 100-240 V 24 V 100-240 V

DANGER! Off
Electric shock risk

Protection class I: H05VV-F or similar


Protection class III: LiYY or similar
Wire cross-section: 0.25-2.0 mm2
(30 AWG-14 AWG)

L = 100 mm (3.94 in.)


Grouding wire L = 120 mm (4.72 in.)

4
1. 2.

2.b (100-240 V) 2.c (100-240 V)

3. 4.

Max. 3 Nm
(26.5 in-lb)

5
5.

M3x8

Note: Only protection class I

6.

Max. 1.4 Nm
(12.4 in-lb)

6
Terminal Description
L24 Power supply 24 VAC/VDC
M* Neutral for power supply 24 VAC/VDC and signals
L Power supply 100-240 VAC
N Neutral for power supply 100-240 VAC
Yi Input signal for proportional control 0(4)..20 mA, 500 Ω
YV Input signal for proportional control 0(2)..10 VDC, 47 kΩ
Xi Output signal 0(4)..20 mA, max. resistance 700 Ω
XV Output signal 0(2)..10 VDC, max. 8 mA or min. load resistance 1.25 kΩ
Dw 3-point control signal for extending actuator spindle (24 VAC/VDC or 100-240 VAC)
Up 3-point control signal for retracting actuator spindle (24 VAC/VDC or 100-240 VAC)
B Connection for potential free contact (e.g. open window detection), max. 100 Ω, max. 10 m
(32.8 ft) cable or shielded
COM1, COM2 Common contacts of relays 1 & 2, max. 250 VAC, max. 5A @ 250 VAC on resistive
NC1, NC2 Normally closed contacts for relay 1 & 2
NO1, NO2 Normally open contacts for relay 1 & 2

24 V

0(2)-10 V 0(4)-20 mA
M M

L24 M Yi Yv Xv Dw Up L24 M Yi Yv Xv Dw Up

24 VAC/VDC 24 VAC/VDC
0 VAC/VDC 0 VAC/VDC
0(2)..10 VDC 0(4)..20 mA
0(2)..10 VDC 0(2)..10 VDC

3-point On-off
M M

L24 M Yi Yv Xv Dw Up L24 M Yi Yv Xv Dw Up

24 VAC/VDC 24 VAC/VDC
0 VAC/VDC 0 VAC/VDC

0(2)..10 VDC 0(2)..10 VDC

24 VAC/DC operating only with safety transformer according EN 61558-2-6

7
100-240 V

0(2)-10 V 0(4)-20 mA
M M

L24 M Yi Yv Xv Dw Up L N Dw Up L24 M Yi Yv Xv Dw Up L N Dw Up

0 VAC/VDC 0 VAC/VDC
0(2)..10 VDC 0(4)..20 mA
0(2)..10 VDC 0(2)..10 VDC

100-240 VAC 100-240 VAC

PE PE

3-point On-off
M M
L24 M Yi Yv Xv Dw Up L N Dw Up L24 M Yi Yv Xv Dw Up L N Dw Up

0
0 VAC/VDC 0 VAC/VDC

0(2)..10 VDC 0(2)..10 VDC

100-240 VAC 100-240 VAC

PE PE

24 VAC/DC operating only with safety transformer according EN 61558-2-6

8
Relay (TA-Slider 750/1250 Plus)

COM NC NO COM NC NO
B M Xi M 1 1 1 2 2 2

**

0(4)..20 mA
A
0 VAC/VDC*
*) Low voltage neutral
**) Ground connection required.
PE

BUS (TA-Slider 750/1250 Plus)

Ethernet (BACnet/IP, Modbus/TCP) RS 485 (BACnet MS/TP, Modbus RTU)

RJ 45 A B GND A’ B’

B
RS 485

Ethernet

GND

A B GND A’ B’

A A
RS 485

RS 485

B B

GND GND

Note: A, B, A’, B’ and GND terminals are


isolated from all other terminals.

9
Quick start

1. ON 2. >1 sec.

>5 sec.
“AUTO”

3. 4.

Micro USB

HyTune app

10
LED

LED

11
We reserve the right to introduce technical alterations without prior notice.

www.imi-hydronic.com