Professional Documents
Culture Documents
Huawei CQI Parameter Improvement Topic
Huawei CQI Parameter Improvement Topic
MOD
CELLALGOSWITCH:LOCALCELLID=X,DLSCHSWITCH=FreqSelSwit
ch-1;
When the switch is off, when the PUCCH power control detects DTX,
the eNB does not process the SINR measured in the DTX state; when
the switch is on, when the PUCCH power control detects DTX, the
eNB still processes the measured SINR, and generates a successful
control command word and sends it to UE. This parameter only
applies to FDD and TDD.
MOD
CELLALGOSWITCH:LOCALCELLID=X,ULPCALGOSWITCH=Pucch
PcDtxSinrSwitch-1;
This parameter represents the CQI cycle adaptive switch. If set to ON,
the CQI period is configured adaptively according to the air interface
load of the cell; if it is set to OFF, the CQI period is configured by
UserCqiPeriod. This parameter only applies to FDD and TDD.
When the CQI cycle adaptive switch is turned off, a fixed configuration
is used. This parameter indicates the CQI cycle in the fixed
configuration, and only takes effect when the CQI cycle adaptive
switch is turned off. When the UserCqiPeriod configuration value is
2ms, for TDD cells, the value of the cell automatic modification is
5ms. This parameter only applies to FDD and TDD.
MOD
CELLCQIADAPTIVECFG:LOCALCELLID=X,CQIPERIODADAPTIVE=
OFF,USERCQIPERIOD=ms160;
This parameter controls the aperiodic CQI resource configuration and
aperiodic CQI reporting trigger of the handover user. This parameter is
set to ON, and aperiodic CQI resources are configured in the
handover command. For users without periodic CQI configuration, an
aperiodic CQI report is triggered when there is a downlink service after
the handover is completed; this parameter is set to OFF, and it is not
configured in the handover command. For aperiodic CQI resources,
the aperiodic CQI configuration is performed after the handover is
completed. This parameter only applies to FDD and TDD.
MOD
CELLCQIADAPTIVECFG:LOCALCELLID=X,HOAPERIODICCQICFG
SWITCH=ON;
MOD
CELLCQIADJALGO:LOCALCELLID=X,CQIOPTSWITCH=PUSCH_C
QI_FALSE_DETECTION_SW-1;
MOD
CELLCQIADJALGO:LOCALCELLID=X,CQIOPTSWITCH=PUCCH_C
QI_FALSE_DETECTION_SW-1;
The smaller this parameter is set, the faster the PUCCH power
adjustment, but the higher the probability of billiard adjustment; the
larger the parameter is set, the slower the PUCCH power adjustment,
but the lower the probability of billiard adjustment.
MOD CELLPCALGO:LOCALCELLID=X,PUCCHPCPERIOD=1;
The smaller this parameter is set, the smaller the PUCCH power of
users in this cell is, and the smaller the PUCCH interference to other
users in this cell and the users in neighboring cells; The greater the
PUCCH interference with neighboring cell users.
MOD
CELLPCALGO:LOCALCELLID=X,PUCCHPCTARGETSINROFFSET=
10;
MOD
CELLPDCCHALGO:LOCALCELLID=X,PDCCHSYMNUMSWITCH=E
CFIADAPTIONON;
MOD CELLULPCCOMM:LOCALCELLID=X,P0NOMINALPUCCH=-
115;
When the switch is turned on, the UE is triggered to enter the DRX
state, the UE will save more power, and the network performance
impact is limited by the DRX parameter configuration. This parameter
does not take effect when dynamic DRX (only applicable to LTE) is
enabled.
MOD DRX:DRXALGSWITCH=OFF;
CQI reliability optimization switch: When the switch is on, more falsely
detected CQIs can be identified in interference scenarios and filled
with historical CQI values; when the switch is off, the falsely detected
CQIs will not be identified. This parameter only applies to FDD and
TDD.
MOD
CELLALGOSWITCH:LOCALCELLID=X,DETECTIONALGOSWITCH=
CqiReliableSwitch-1;
There are four options for the MIMO mode adaptation type parameter
in the multi-antenna eNodeB, including:
Open loop adaptive mode: The terminal only reports RANK and CQI,
but does not report PMI.