Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Controller Configuration Tool (CCT) Catalog Page

Code No. LIT-1900386


Software Release 10.2
Issued December 15, 2015
Refer to the QuickLIT website for the most up-to-date version of this document.

The Controller Configuration Tool (CCT) is used to configure, simulate, A Commissioning mode-only version of the CCT software is available
and commission the Field Equipment Controllers (FECs), Advanced for individuals having only commissioning tasks (for example, balancing
Application Field Equipment Controllers (FACs), Network Control contractors). The Configuration and Simulation modes are disabled in
Engines (NCEs), Input/Output Modules (IOMs), and Variable Air Volume the CCT Commissioning mode-only software.
(VAV) Modular Assembly (VMA16s). You can also configure N2 VMAs
using the System Selection Wizard or using pre-built applications that Refer to the CCT Installation Instructions (LIT-12011529) and the
cover the most common VMA configurations. Controller Tool Help (LIT-12011147) for details.

CCT operates in three modes that provide key functionality for your Features
system: Configuration, Simulation, and Commissioning. • capability to customize standard control system logic that is created
from simple system selection trees
The Configuration mode allows you to select a wide variety of
• consistent user interface across the Configuration, Simulation, and
mechanical and control logic options through system selection trees
Commissioning modes, with the option of using perspectives to
for typical air handling, terminal unit, central plant, and VAV box
customize the UI display
mechanical systems. When required, you can customize the standard
logic provided by the system selection process to meet your specialized • flexible connection capabilities for loading and commissioning
control logic requirements. To use the Controller Tool Help to assist controllers; ability to download, upload, and upgrade multiple
you as you make selections in the System Selection Tree, press F1. controllers at once

The Simulation mode allows you to review the application logic as if


you were commissioning the system. You can make adjustments to Figure 1: CCT
setpoints, inputs, or sensors during a simulation session to validate the
logic before assigning the configuration to a specific controller.
Files can be downloaded to the FECs through different network
connection points. You can connect using a Wireless Commissioning
Converter (MS-BTCVT-1) or BACnet® router (TL-BRTRP-0) between
your laptop and the MS/TP bus, using a USB adapter with ZigBee®
driver for your laptop computer when using the ZFR wireless system,
or using the Ethernet Passthru mode.
The Commissioning mode allows you to validate the sensor and control
point interfaces, and to adjust key setpoints and setup parameters after
you download these controllers.
For VAV applications, CCT includes an optional box flow test to
automatically exercise all the VAV boxes to ensure correct mechanical
installation and proper configuration of the key flow setup parameters.
In addition, the Commissioning mode has a Balancer view for VAV
applications that guides you through the typical steps of setting the flow
constants.
Selection Chart
The ZFR Checkout Tool (ZCT) is available to validate the wireless Table 1: Selection Chart
connectivity and health of your wireless mesh network. Code Number Description
MS-CCT-0 CCT media for both the full and
commissioning-only versions.

Controller Configuration Tool (CCT) Catalog Page 1


CCT Technical Specifications
Table 2: Controller Configuration Tool (CCT) System Requirements
Recommended Computer Intel® Core™ 2 Duo E6700 or better (Intel Core 2 Duo E4300 minimum)

20 GB free hard disk available (600 MB minimum)

DVD drive
Recommended Memory Computer Platforms: 2 GB RAM recommended (1 GB RAM minimum)
Supported Operating System (OS) and Database Windows® 8.1 Pro and Windows 8.1 Enterprise Editions (32-bit or 64-bit)
Software 1
Supports Microsoft® SQL Server® 2014 Express (32-bit or 64-bit) with SP1, Microsoft SQL Server 2012
Express with SP2 (32-bit or 64-bit), or Microsoft SQL Server 2008 R2 Express with SP3 (32-bit or 64-bit)

Note: A 32-bit operating system only supports a maximum of 4 GB memory. For best performance, use a
64-bit operating system.

The OS and software must both be 32-bit or 64-bit.


Windows 7 Professional, Enterprise, and Ultimate Editions with SP1 (32-bit or 64-bit)
1
Supports Microsoft SQL Server 2014 Express (32-bit or 64-bit) with SP1, Microsoft SQL Server 2012
Express with SP2 (32-bit or 64-bit), or Microsoft SQL Server 2008 R2 Express with SP3 (32-bit or 64-bit)

Note: A 32-bit operating system only supports a maximum of 4 GB memory. For best performance, use a
64-bit operating system.

The OS and software must both be 32-bit or 64-bit.


Required Web Browser Software for Metasys® Client Windows Internet Explorer® version 9, 10, and 11
Computers
Note: In Internet Explorer 11, select the Use Microsoft compatibility lists option, found under Tools >
Compatibility View Settings, to ensure that websites appear and function correctly.

Note: Web browser software is required if you want to view the Controller Tool Help (LIT-12011147) online.
However, you can also access this help system as a PDF from the software.
Network Communication for CCT Client Computer Ethernet network interface card 10/100 Mbps (100 Mbps network recommended)
Software Optionally Installed During CCT Install Microsoft .NET Framework version 3.5 with SP1 or 3.5.1

Microsoft SQL Server 2008 Express software with SP2


Additional Requirements (Order Separately) Bluetooth® Commissioning Converter (MS-BTCVT-1)

Laptop with Bluetooth® wireless communications or a computer with a USB Bluetooth converter

USB Dongle with ZigBee® Driver (ZFR-USBHA-0) provides a wireless connection through the CCT to allow
wireless commissioning of the wirelessly enabled FEC and VMA16 field controllers. Also allows use of the
ZCT in CCT.

Adobe® Reader® software

Note: A PDF reader software is required for the Print function in CCT.
Optional Hardware Any network or local printer supported by the qualified Windows operating system

1 To use SQL Server 2014 SP1 with Metasys products, you must install Microsoft cumulative update package 1 (KB3067389) for SQL Server 2014 SP1. To
download the update package, visit https://support.microsoft.com/en-us/kb/3067839/.

Building Efficiency
507 E. Michigan Street, Milwaukee, WI 53202
Johnson Controls® is a registered trademark of Johnson Controls, Inc.
All other marks herein are the marks of their respective owners.© 2015 Johnson Controls, Inc.

Published in U.S.A. www.johnsoncontrols.com