INFLATABLE LIFERAFT Pages: 1 of 1
FREQUENCY OF NAP, WP, GI AND FS TESTS FOR LIFERAFT

SERVICING INTERVALS TYPES OF TESTS

End of 1 yea WP Test


End of 2 year WP Test
End of 3 year WP Test
End of 4 year WP Test
End of 5 year GI Test
End of 6 year WP Test
End of 7 year WP Test
End of 8 year WP Test
End of 9 year WP Test
End of 10 year Gl Test+FS
11 to 14 year NAP Test+FS
15 year GI Test+NAP +FS
16 to 19 year NAP Test+FS
20 year GI Test+NAP +FS
A 10% over-Load suspending test shall be carried out for 5 minutes in service interval of every 2 years from
the 2nd service. If this Test has been done for the Davit-Launched liferaft, it is unnecessary to carry out FS
test from 11 Year.

NAP - Necessary Additional Pressure test WP - Working Pressure (compressed air)


GI - Gas Inflation (fitted gas) FS - Floor Seam