Construction Requirements as per Fire Life Safety Code (FLS):
Project: Hilmi Sir Building, Plot No. 867 Phase 5
Building Height: 37.5 mts
No of Floors: 9 no’s
Occupancy:
Ground Floor: Mercantile
Typical and Penthouse: Hotel/Apartment Building
Construction Type: Type 2 (222)
Construction element Rating (hr)
Exterior bearing walls Supporting more than one floor, columns or 2 other bearing walls Supporting one floor only 2 Supporting a roof only 1 Interior bearing walls Supporting more than one floor, columns or 2 other bearing walls Supporting one floor only 2 Supporting a roof only 1 Columns Supporting more than one floor, columns or 2 other bearing walls Supporting one floor only 2 Supporting a roof only 1 Beams, girders, Trusses and Arched Supporting more than one floor, columns or 2 other bearing walls Supporting one floor only 2 Supporting a roof only 1 Floor/ Ceiling assemblies 2 Roof/ Ceiling assemblies 1