Yonker Yk 8000c Multipara Monitor
Yonker Yk 8000c Multipara Monitor
Instructions
1
Responsibility Statement
Xuzhou Yong kang Electronic Technology Co., Ltd. for errors in this manual, installation error,
operator error without warranty of any kind, for incidental or consequential damages does not
assume any legal responsibility.
This manual contains content protected by copyright law. Copyright, without the prior written
permission of any part of this manual may be reproduced, photography, copy, or translated into
another language.
The Company only in the following circumstances that should be responsible for the instrument
reliability, security, and Performance, namely: assembly operations, expand, resize, performance
improvement and repair personnel authorized by the Company or institution; related electrical
equipment in line with national standards; follow the instructions in this manual to operate the
instrument.
Contents of this manual can be made to change without notice
Warning
If bears the responsibility to use this instrument in all hospitals or medical institutions can not
achieve a satisfactory maintenance schedule, it will cause abnormal instrument failure, and may
endanger human health.
Quality Assurance :
Free Services :
If Comply with the provisions of the Company Ordinance warranty service specified equipment
(1) If you exceed the scope of our warranty service equipment required by regulations, the
(2) Even during the warranty period, due to the following causes product needs repair
circumstances: human damage; grid voltage exceeds; The equipment specified range; irresistible
natural disasters
Yong kang companies in the following case (including but not limited to) caused by the direct,
indirect or final damage and delay irresponsible:
Components are removable, stretch, re-commissioning; replacement without permission
2
accessories Yong kang company or by a non-authorized personnel Yongkang maintenance
machines。
Return of goods
Return procedures
If you need to return to the Company, please follow the steps below:
1.Obtain a right of return. And contact our customer service department, told the product series
number, series number if non-legible, returns will not be accepted. Please include the model,
2.Shipping: Instruments shipped to the company's maintenance, users should bear the shipping
Corporate information
Registered Address: Room 404 No. 21 Building Yunlong District Xuzhou City
Production Address :East office seventh floor, and 508 room No. 21 Yunlong District ,Xuzhou
City
Service Address: East office seventh floor, and 508 room No. 21 Yunlong District ,Xuzhou City
Tel:0516-66670805 66670806
Fax :0516-82027233
Post :221004
Website :www.ykmedical.cn
Email : office@ykmedical.cn
3
Chapter One Product Overview
Brief introduction
This operation manual will be Specify for central monitor’s performance metrics, use, etc.
Operator must read this manual carefully to be able to properly use the central monitor, so that the
entire device has reached its required safety standards and performance indicators to better serve
you.
Safety requirements
Cautions:
Tevet Tip:
In order to make the central monitor can be safely grounded, the hospital must provide live,
neutral and ground complete power outlet.
Electrosurgical loop must be connected properly to prevent burns, and even life-threatening.
Not free to remove the central monitor cover, to prevent electric shock
Can only be used in accordance with various accessories specified by the manufacturer
With flammable anesthetic gases ,the Central Monitoring will not be used
Not on the central monitor for high temperature, high pressure, gas fumigation or liquid
immersion, cleaning or disinfecting central monitor before you must disconnect the power cord.
The product from the host computer (with standard keyboard and mouse), monitors, wired
network communication section, wireless network communication section, application software
This product can be from 1 to 64 with both supporting the use of monitors, central monitoring
system composed on heart rate, noninvasive blood pressure, oxygen, respiration, body temperature
and other parameters for centralized monitoring.
When you need product support, please contact with agents and distributors. Before you call,
please record the following information
Symptom or faulty component model;
Failure of ongoing operations and their users around the steps
4
If possible, please use the keyboard Prescript key interception of the screen, and open the
Windows system drawing tool that will paste the screen shot into Paint software, then save it as an
image file, as a fault report submitted to the maintenance engineer
. The model and serial number of the instrument
This manual is random with documents, should be placed near the instrument for easy viewing.
Before using this instrument, please read this manual carefully in order to correctly and safely use
the equipment to achieve its performance targets, while ensuring the safety of the operator and
patient.
5
Chapter Two Central Station Description
Parameter display: heart rate, respiratory rate, ST segment, PVCs, oxygen saturation, pulse
rate, noninvasive blood pressure, body temperature, carbon dioxide concentration, invasive
blood pressure;
Support the central station and bedside machine real bidirectional control;
Supports single, dual display;
Sound and light alarm, and text prompts.
Central network wireless or wired options, wireless monitoring network to better meet the clinical
needs.
6
Chapter Three Operating Instructions
3.1 The main interface
Central monitoring system provides basic monitoring functions in order to achieve multiple
patients at the same time monitoring, central monitoring system of guardianship main interface as
shown:
Central monitoring system can be divided into a custody arrangement 1~ 32, according to need to
select a different bed layouts.
The main interface displays a total of 1 to 32 monitoring pane, each pane is used to display the
monitor data coming from actual custody, as shown:
①Information prompt area
②Waveform area
③Parameter area
7
①
②
① Information prompt area :The top of the pane, shows the number of beds, patient name,
alarm information, and the current mode.Following is the comment of Information prompt area.
Beds: refers to the number of beds in patient care.
Patient Name: refers to the name of the patient currently being monitored
Alarm Information: Show the patient's alarm information, respectively, physiological alarms and
technical alarms. (The setting method, see "Alarm" chapter)
Current mode: The current display state. Such as: demo mode or measurement mode
In the maximum configuration, the system standard interface can be displayed in the waveform
area 2 ECG waveform, SpO2 plethysmography waves, breathing waveform. The waveform name
displayed on the left top of each channel waveform. ECG can choose according to requirements.
Heart Radio on the Road also shows the channel gain and heart wave filtering methods.
As picture :
8
③Parameter Area: Parameter area is located in the right side of the waveform area, and the
waveform is basically corresponds place. In the parameter area displays parameters: ECG
—Heart rate or pulse rate (Unit: stroke / min)
— Channels 1 and 2 ST segment analysis ST1, ST2 (Unit: mV mV) oxygen
saturation SpO2
— Oxygen saturation SpO2 (unit:%)
—Pulse rate (Unit: stroke / min)
NIBP
— In order from left to right are systolic, diastolic and mean pressure; (Unit: mmHg
mmHg or kPa kPa)
IBP
- Followed by systolic, diastolic and mean pressure; (Unit: mmHg mmHg or kPa
kPa)
RESP
-Respiration rate (Unit: times / min)
TEMP
3.3Menu
This Monitoring system is Flexible , monitoring the waveform sweep speed ect can be configured
by the user’s need .Opening the message alert bar left“ ”,Pop-up menu shown in Figure 3-1,
9
Figure 3-3 Menu
In the menu, select "Display beds" dialog box will pop up as shown:
At this point you can choose bed for custody, but if choose other bed ,the fixed monitoring pane
will display the selected number for guardianship. And the Guardianship Pane will be exchanged
For example: In the past number of beds is " bed1 ", and you want to choose "bed 3",after select
"bed 3", "bed 1" and "bed 3" guardianship window will be exchanged .
.As Picture :
10
Before Exchange bed:
Bed 1 Bed 3
11
In the menu, select "associated with the patient" dialog box will pop up as shown:
According dialog box to select the name , ID number, hospital number , social security number
and date of registration to check patient information.
Unspecified guardianship records: the role is to replace the patient information.
When monitoring pane has been monitoring the patient, if want to be associated with other
patients in same pane, the following dialog will appear:
Click the "OK" button, the system will automatically save unknown patient’s before date and
show below associated new patient. And complete the operation associated
"Cancel" to give up switching patient information.
12
3.3.3 Relieve patients associated
In the menu, select "associated with the patient" dialog box will pop up as shown:
Note :In the case of patient care can not be forced to relieve the patient association,
13
Figure 3-8 care Settings
SPO2 settings: Waveform Speed: four options available, "6.25", "12.5", "25" and "50"
When you select "Manual" mode, you need to click next to "Start / Stop blood
When you select "Auto" mode, the interval can be selected, options range from 1min
~ 480min.
Note
14
When select "Auto" mode, firstly you must manually start the measurement of blood
pressure, after which it will automatically monitor blood pressure measurement according to
time intervals.
RESP set: ① gain setting: There are "1/4X", "2/1X", "1X", "2X" and "4X" is optional.
② wave speed: "6.25", "12.5", "25" and "50" four kinds of velocity selection.
IBP set: ① IBP1 Indicators and IBP2 indicators: there were eight optional, namely: "ART",
②Wave speed: "6.25", "12.5", "25" and "50" four kinds of velocity selection.
③ IBP1 gain IBP2 Gain: there were 11 kinds Optional: -33 to 300; -26 ~ 240; -20 ~
180; -13 ~ 120; -11 to 100; -8 to 80; -6 ~ 60; -3 ~ 30; -2 to 18; -1 to 10; -1 to 6
CO2 setting: ① wave speed: "6.25", "12.5", "25" and "50" four kinds of velocity selection
Beds information: Monitor settings, information can also be set up beds, as picture:
15
1"General Parameters guardianship" as picture :
16
Figure 3-9-3 lists ECG monitoring blood pressure, blood oxygen
17
Figure 3-9-5 video channel ECG monitoring
18
Picture 3-9-7 6channel electrocardiograph monitoring
19
Picture 3-9-9 CO2 monitoring
Picture 3-9-8
3.3.4.2 Alarm Settings
Alarm limits of each parameter and technical alarm could be set. As picture:
Warning
In order to prevent delay treatment, please fully operate alarm settings for each patient. At
the same time, guarantee the alarm can send out alarm sound. Cautiously cancel "enable".
20
Picture 3-10 alarm settings
3.3.5 Intensive Monitoring
Open the menu of "Intensive Monitoring’’ in a monitoring pan, the interface will pop up a
concealable, scalable and printable information viewing area,as picture:
Intensive
Monitoring
Area
21
history information of the patient is being chosen as “dispel patient associations " when he
discharges from hospital, the information will be reserved. The system function can store
historical data of 20000 patients, which includes parameter info of the last day before the patient
discharges from hospital and recent 50 alarm information.
The following view will display when you open history overview:
History
Overview
Image
22
Similarly, click title "patient information" as shown in picture 3-12, you can switch to view of
patient basic information review, which including patient name, age, etc. This view could only
been viewed but not modified. Please click “patient management” to modify basic information of
patient. Please refer to picture 3-21“patient modification” for specific operation.
(2ECG review
Open ECG review of select title to unfold ECG review view, as picture 3-13:
23
“zoom scale button" dialog box as picture 3-16, users can operate "zoom" according to needs.
The right side of the interface has "print" and "zoom" option. The print manner is the same as
picture 3-14. "Zoom" can change view size.
Click “zoom” button in the top right corner of the above picture, the interface as following picture
3-15 will pop up.
B:If the choosing duration is shorter than current displaying one, the displaying scale will
not change. But in the data review view will appear a translucent form, the form identify the
time range of zooming. If you want to change the time, please click arrow marked button on the
lower row of the zoom view in order to dolly move this transparent form. The operation can
also be conducted by dragging translucent form directly with the mouse.
C : After assuring the time range for zooming (namely translucent form location), click
“confirm” button on the zoom form, then the curve within this duration will be displayed in full
screen, so as to complete the amplification curve operation.
D: Zoom view lock: Default condition of the button on the top right corner is unlocked (refer
to picture 3-15), at this time after completing the current zoom operation (namely after clicking
"confirm" button), the scale will automatically shut down. If you need to continue after this,
please click this button, the icon will turn to the shape of downward, now the zoom view is
locked.
This view will not close after each zoom operation until manually click”close” button.
If you click the "print" button on the right side, alarm list of current range will be printed and
exported to system tolerant printer. Print way is the same as picture 3-14
24
Picture3-16 NIB Preview view
This view shows all NIBP record of the current page within monitoring time scope, including
record time, systolic pressure, diastolic pressure, average pressure and value of pulse frequency.
If you click the "print" button on the right side, alarm list of current range will be printed and
exported to system tolerant printer. Print way is the same as picture 3-14
25
exported to system tolerant printer. Print way is the same as picture 3-14.
1.“quit”button:There will pop up window prompt after clicking to confirm whether you want
to exit the system. After confirmation, the system will stop all bed monitoring and save the data
into database, and then quit the system.
2.“about” button: After clicking, it will display information as the supplier of this system,
version number, boot time and running time, etc.
3.“volume”button:Prompt alarm volume. There will pop up the form after clicking, which
has setting functions as high, medium, low and mute.
26
Picture 3-19 newly added patient
Users could create new patient information is this dialog box.
②“modify”:as shown is picture
27
Choose the patient whose information needed to be modified to modify in this dialogue box.
③“delete”:as the following picture
5、
“date review”button:Open the view and choose a patient to review recorded information
of the specified patient. The content is the same as “history review” in “menu”. Refer to chapter
1.3.6 history review.
28
Picture 3-22 system setting
System Setting is divided into: general setup, data storage setting and color.
General setup:Conduct settings as unit set, ECG waveform network switch, presentation mode
switch, alarm volume switch and the shut down switch of the system and computer and printer
setting, hospital name and system name could be also modified according to special needs.
Data Storage:This setting is the store path of printed picture. Users can also set the storage path
according to special needs.
Color:Waveform color and parameter value color could be changed,as the following picture:
Picture 3-23 System setup on changing colors of waveform and parameter value
Move the mouse onto the colored box, click it and it will pop up a pane for changing colors, users
29
can change waveform color according to their own needs.
7、
“monitoring layout”button:Choose different bed layout according to your needs,
such as convention view of Bed No.8, view of Bed No.4(intensive care of Bed No.1).
8、
“bed management”button:To display all relative information of current beds, such
as bed name, monitoring condition, relative equipment and whether has bed view displaying.
Choose one bed, you could rename it and conduct “get to” specified bed view. As the following
picture:
Attention
Click "Communication window" or " bed" can order the beds according to the sequence or bed
numbers.
9、
“ intensive care”button:Open message view area, it will display intensive care view.
30
The content is the same as which of “intensive care” in “menu”. Refer to chapter 1.3.5
intensive care。
10、
“ alarming bed”button:Open message view area, it will list all current alarm beds
and corresponding alarm level, selected one of the beds, you could conduct "intensive care",
"set alarm", "get to" operation. If there is a bed occur to alarm under current system, the button
will show corresponding color upon alarm level . As the following picture:
31