门涵通图

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

T1=300

W=VARIES

H=VARIES
W1=W+2*300+200

CAST IN SUIT FLOOR SLAB

T2=300
CLASS 25/19 CONCRETE

CLASS 15/19 CONCRETE


WORKING FLOOR 50MM THICKNESS W2=W1+200

TYPICAL CROSS SECTION


OF SINGLE PORTAL CULVERT UNIT

S=100

W=VARIES W=VARIES

H=VARIES
W1=2W+S+200

W2=W1+200

TYPICAL CROSS SECTION


OF TWO CELLS PORTAL CULVERT UNIT

Y10-B06-250-TB
t

L=VARIES
Y10-B03-250-TB&BT

Y10-B04-250-TB&BT

Y10-B07-250-BT&TB
B=W1+2D*tan(30°)

Y10-B05-250-TT&BB

Y12-B02-250-TT
Y16-B01-250-BB

Y10-B08-250-BT
t D=1.5(H+T1) t

REPUBLIC OF MALAWI
ROADS AUTHORITY
Private Bag B346
Lilongwe STANDARD DRAINAGE DETAILS : BOYYOM SLAB FOR
PORTAL CULVERT
Y10-B13-250

500
Y10-B14-300

D*tan(30°) W1 D*tan(30°)

h=VARIES
Y10-B12-250-NF
Y10-B11-250-FF

Y10-B15-250-FF&NF
1000
Y10-B06-250-TB Y10-B07-250-BT&TB Y10-B08-250-BT

Y10-B10-250-NF
Y10-B09-250-FF

TYPICAL CUT OFF WALL

TYPICAL WING WALL

W+2*300 MORTAR (MIX 1:6)


IN FIRMLY AFTER PLACING
PORTAL UNITS AND BEFORE
BACKFILLING
100

25 25

Y10-B14-300

50
500

Y10-B13-250

DETAIL A
NOTES:
1.STRUCTURAL SYSTEM:
TYPICAL HEAD WALL PRECAST REINFORCED CONCRETE PORTAL CULVERT
SUPPORTED BY A IN-SITU REINFORCED CONCRETE
FLOOR SLAB.
2.50mm BLINDING (CONCRETE CLASS 15/19) MUST BE
CAST UNDER ALL FOOTINGS.
3.CONCRETE COVER OVER REINFORCEMENT:
FOOTINGS:40mm
WING WALL:25mm
HEAD WALL:25mm
CUT OF WALL:25mm
4.THE FOLLOWING CLASSES OF CONCRETE SHALL BE
USED:
BOTTOM SLAB:CLASS 25/19
WING WALL:CLASS 25/19
HEAD WALL:CLASS 25/19
CUT OF WALL:CLASS 25/19

REPUBLIC OF MALAWI
ROADS AUTHORITY
Private Bag B346
Lilongwe STANDARD DRAINAGE DETAILS : WING WALL AND CUT OFF
WALL AND HEAD WALL FOR PORTAL CULVERT

You might also like