Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

PROPOSED 3(Three)

STORIED
RESIDENTIAL
SCHEDULE OF COLUMN BUILDING
COLUMN FOUNDATION TO ABOVE GB. TO ABOVE GROUND FLOOR . TO
LEGEND GB. LEVEL GROUND FLOOR 1ST FLOOR
221" clear cover 221" clear cover 221" clear cover Nabinagar, B.Baria
8mmØ @ 5"~7"~5" c/c 8mmØ @ 5"~7"~5" c/c 8mmØ @ 5"~7"~5" c/c
12"

10"

10"
4-16mm Ø 4-16mm Ø 4-16mm Ø
12" 10" 10"
221" clear cover 221" clear cover 221" clear cover
8mmØ @ 5"~7"~5" c/c 8mmØ @ 5"~7"~5" c/c 8mmØ @ 5"~10"~5" c/c
14"

12"

12"
4-16mm+2-12mm Ø 4-16mm+2-12mm Ø 4-16mm+2-12mm Ø
12" 10" 10"
221" clear cover 221" clear cover 221" clear cover
8mmØ @ 5"~7"~5" c/c 8mmØ @ 5"~7"~5" c/c 8mmØ @ 5"~7"~5" c/c
14"

12"

12"
4-16mm+4-12mm Ø 4-16mm+4-12mm Ø 4-16mm+4-12mm Ø
14" 12" 12"
Provide 1 1 2" clear cover for all column above top of Grade beam.
Add. 1" ext. to each dimension of column
to provide 21 2" clear cover below G.B.
Provide D8mm Ø tie @ 5"~7''~5"c/c for all column.