Client: FGW Date: 15 Sep 21

Project: Pitt Street Prepared: NA


Deflection and Capacity Check for Simply Supported - Uniformly Checked: GW
Subject:
Distributed Job No: 21088

Calculation of breaking load at the disc slots


Input Parameters
Characteristic tensile value of stone (Mean
Modulus of Rupture - Soaked) (σRtk) 3.40 Mpa

Permissible wind load converted from ULS -ve


wind 1.1kpa*0.718 0.79 kpa

Thickness of stone (tst) 50 mm


Drilled hole diameter for disc(Øhole) 60 mm
Contact depth of the disc (ld) 20 mm
Length of Pin 40 mm
Spall angle based on assumed cone failure 35 Degree
surface of (αspall)

Stress concentration factor 2.4


Safety factor at stone fixing / achorage location
from ASTM STP 996 for COV < 10% (SFanc) 7.5

Length of stone Panel 1.5 m


Hieght of stone Panel 0.75 m
Load Per Anchor as per design (P) 111.07 N
Allowable stress in the disc region 0.45 Mpa

Analysis
Moment = PxId= 1110.6563 Nmm
Stess= 𝜎_𝑚𝑎𝑥=6𝑀/ 0.9996 Mpa
〖𝑏𝑑〗 ^2
NOT OK
𝑀_𝑚𝑎𝑥= 〖𝜙𝑓 _𝑦 𝑆 〗 _𝑥⇒𝑆_𝑥=𝑀_𝑚𝑎𝑥/(𝜙𝑓_𝑦 )

NOT OK
Client: FGW Date: 15 Sep 21
Project: Pitt Street Prepared: NA
Deflection and Capacity Check for Simply Supported - Uniformly Checked: GW
Subject:
Distributed Job No: 21088

Calculation of breaking load at the dowel hole


Input Parameters
Characteristic tensile value of stone (Mean
Modulus of Rupture - Soaked) (σRtk) 3.40 Mpa

Thickness of stone (tst) 50 mm


Drilled hole diameter for 7 mm pin(Øhole) 2 mm
Contact depth of the pin dowel(ld) 20 mm
Spall angle based on assumed cone failure 35 Degree
surface of 55 ° (αspall)
0.61 Radian
Stress concentration factor for cylindrical hole to
take into account the additional prying action
1.6
induced by a resilient sleeve (or epoxy)
𝑀_𝑚𝑎𝑥= 〖
Safety factor at stone fixing / achorage location
from ASTM STP 996 for COV < 10% (SFanc) 7.5
Load Per Anchor as per design (P) 0.32 kN

Analysis

65.89 N

0.07 kN NOT OK
Client: FGW Date: 15 Sep 21
Project: Pitt Street Prepared: NA
Deflection and Capacity Check for Simply Supported - Uniformly Checked: GW
Subject:
Distributed Job No: 21088

Calculation of Disc anchorage strength


Input Parameters
Characteristic tensile value of stone (Mean
Modulus of Rupture - Soaked) (σRtk) 3.40 Mpa

Permissible wind load converted from ULS -ve


wind 3.25kpa 2.17 kpa

Safety factor at stone fixing / achorage location


from ASTM STP 996 for COV < 10% (SF anc) 7.5

Distance between centre of supports assuming


simply supported beam (L) 500 mm

Thickness of stone (tst) 50 mm


Disc slot width (tk) 8 mm
Dimensional tolerance - width 1 mm
Dimensional tolerance - Depth 2 mm
Fin thickness(tf) 20 mm
Depth of the fin (Hf) 31 mm
Effective depth of the fin (Hf.eff) 29 mm
Disc clearance distance to the rail or bracket(C)
2 mm
Depth of rail contact 27 mm 𝑀_𝑚𝑎𝑥= 〖𝜙𝑓 _𝑦 𝑆 〗 _𝑥⇒𝑆_𝑥=𝑀_𝑚𝑎𝑥/(𝜙𝑓_𝑦 )
Length of strap anchor (Lanc) 125 mm
Spall angle ° (αspall) 35 14.9958492358

0.61
Effective kerf's depth (deff) 15.00 not correct
Stone width, dimension parallel to Disc (B) 1000.00 mm
Effective contact width of strap anchor(Beff) 167.83 mm
Effective stress concentration factor(Keff) 2.40
Allowable stress in the kerf region 0.45 Mpa
Analysis
σ_𝑒𝑓𝑓=𝐵_𝑒𝑓𝑓/𝐵
Support contact parameter 0.17

〖 3∗𝑃 〗 _𝑝𝑒𝑟∗𝐿∗𝐶= 6510.00


22182.88

〖 2∗σ 〗 _𝑒𝑓𝑓∗𝑡_𝑓^2= 134.27

Maximum tensile stress in the Disc region 512.88

0.51 Mpa NOT OK


Client: FGW Date: 15 Sep 21
Project: Pitt Street Prepared: NA
Deflection and Capacity Check for Simply Supported - Uniformly Checked: GW
Subject:
Distributed Job No: 21088

Calculation of Disc anchorage strength


Input Parameters
Characteristic tensile value of stone (Mean
Modulus of Rupture - Soaked) (σRtk) 3.40 Mpa

Permissible wind load converted from ULS -ve


wind 1.1kpa*0.718 0.79 kpa

Safety factor at stone fixing / achorage location


from ASTM STP 996 for COV < 10% (SF anc) 7.5

Distance between centre of supports assuming


simply supported beam (L) 200 mm

Thickness of stone (tst) 50 mm


Disc slot thickness (tk) 4 mm
Dimensional tolerance - width 1 mm
Dimensional tolerance - Depth 2 mm
Fin thickness(tf) 22.00 mm
Depth of the fin (Hf) 20 mm
Effective depth of the fin (Hf.eff) 18.00 mm
Disc clearance distance to the rail or bracket(C)
2 mm 40mm dia
Depth of rail contact 16.00 mm 𝑀_𝑚𝑎𝑥= 〖𝜙𝑓 _𝑦 𝑆 〗 _𝑥⇒𝑆_𝑥=𝑀_𝑚𝑎𝑥/(𝜙𝑓_𝑦 )
Length of strap anchor (Lanc) 30 mm
Spall angle ° (αspall) 35 2.59543415939

0.61
Effective disc's depth (deff) 2.60 not correct
Stone width, dimension parallel to Disc (B) 1500.00 mm
Effective contact width of strap anchor(Beff) 37.41 mm
Effective stress concentration factor(Keff) 2.40
Allowable stress in the kerf region 0.45 Mpa
Analysis
σ_𝑒𝑓𝑓=𝐵_𝑒𝑓𝑓/𝐵
Support contact parameter 0.02

〖 3∗𝑃 〗 _𝑝𝑒𝑟∗𝐿∗𝐶= 947.76


3539.15

〖 2∗σ 〗 _𝑒𝑓𝑓∗𝑡_𝑓^2= 24.14

Maximum tensile stress in the Disc region 446.01

0.45 Mpa The Capacity is OK


Client: Date: 2 Aug 18
Project: 80 Collins St, Glass Box Prepared: NA
Deflection and Capacity Check for Simply Supported - Load Increasing Checked: AH
Subject:
Uniformly to Center Job No: 99999

SIMPLY SUPPORTED - TRIANGULAR UNIFORM DISTRIBUTED LOAD


Input Parameters
Span (l) 3.00 m
Load width (Lw) 1.45 m
Load Share 0.09
Live Load (LL) 1.40 kPa
Live Load (w) 0.18 kN/m
Dead Load (DL) 0.00 kPa
Dead Load 0.00 kN/m
Dead Load (Self Weight) 0.00 kN/m
Yield Strength (ɸFy) 75.0 MPa

Analysis
Service Reaction (Rs) 0.14 kN
Ultimate Reaction (Ru) 0.21 kN

𝑀_𝑚𝑎𝑥=(𝑤𝑙^2)/12

Service Moment (Ms) 0.14 kNm


Ultimate Moment (Mu) 0.21 kNm

𝑀_𝑚𝑎𝑥= 〖𝜙𝑓 _𝑦 𝑆 〗 _𝑥⇒𝑆_𝑥=𝑀_𝑚𝑎𝑥/(𝜙𝑓_𝑦 )

Required Section Modulus (Sreq) 2.74 ×103 mm3


Provided Section Modulus (Sprovided) 12.00 ×103 mm3 Section Capacity OK

Deflection Check
For Live Load and Dead Load
Load Combination 1.0 DL + 1.0 LL

Δ_𝑚𝑎𝑥=(𝑤𝑙^4)/120𝐸𝐼

Modulus (E) 200000 MPa


Moment of Inertia (I) 260000 mm4
Max Deflection (DL+LL) (Δmax) 2.37 mm
Allowable Deflection (Span/250) (ΔAllowable) 12.00 mm The deflection is OK

For Live Load Only


Load Combination 1.0 LL
Max Deflection (LL) (Δmax) 2.37 mm
Allowable Deflection (Span/500) (ΔAllowable) 6.00 mm The deflection is OK

Strength Utilisation Ratio 0.23


Servicibility Utilisation Ratio 0.40
Maximum Utilisation Ratio 0.40 Live Load Deflection Governs
Client: Date: 2 Aug 18
Project: 80 Collins St, Glass Box Prepared: NA
Deflection and Capacity Check for Simply Supported - Concentrated Load Checked: AH
Subject:
at Midspan Job No: 99999

SIMPLY SUPPORTED - ONE POINT LOAD MIDSPAN


Input Parameters
Span (l) 6.00 m
Live Load (P) 68.00 kN
Dead Load (DL) 91.00 kN
Dead Load (Self Weight) 0.32 kN/m
Yield Strength (ɸFy) 315.0 MPa

Analysis
Service Reaction (Rs) 79.50 kN
Ultimate Reaction (Ru) 105.60 kN

𝑀_𝑚𝑎𝑥=𝑃𝑙/4

Service Moment (Ms) 238.50 kNm


Ultimate Moment (Mu) 316.80 kNm

𝑀_𝑚𝑎𝑥= 〖𝜙𝑓 _𝑦 𝑆 〗 _𝑥⇒𝑆_𝑥=𝑀_𝑚𝑎𝑥/(𝜙𝑓_𝑦 )

Required Section Modulus (Sreq) 1005.71 ×103 mm3


Provided Section Modulus (Sprovided) 569.00 ×103 mm3 Section Capacity Fails
Actual stress on mullion (Ultimate) 556.77 Mpa NOT OK
Deflection Check
For Live Load and Dead Load
Load Combination 1.0 DL + 1.0 LL

Δ_𝑚𝑎𝑥 =(𝑃𝑙^3)/48𝐸𝐼

Modulus (E) 200000 MPa


Moment of Inertia (I) 86400000 mm4
Max Deflection (DL+LL) (Δmax) 41.41 mm
Allowable Deflection (Span/250) (ΔAllowable) 24.00 mm Fails in deflection

For Live Load Only


Load Combination 1.0 LL
Max Deflection (LL) (Δmax) 17.71 mm
Allowable Deflection (Span/500) (ΔAllowable) 12.00 mm Fails in deflection

Strength Utilisation Ratio 1.77


Servicibility Utilisation Ratio 1.73
Maximum Utilisation Ratio 1.77 Bending Moment Governs
Client: Date: 2 Aug 18
Project: 80 Collins St, Glass Box Prepared: NA
Checked: AH
Subject: Deflection and Capacity Check for Simply Supported - Concentrated Load
Job No: 99999

SIMPLY SUPPORTED - ONE POINT LOAD


Input Parameters
Span (l) 5.80 m
Distance to Load (a) 1.90 m
Live Load (P) 0.50 kN
Dead Load (DL) 2.00 kN
Dead Load (Self Weight) 0.32 kN/m
Yield Strength (ɸFy) 315.0 MPa

Analysis
Service Reaction (Rs,1) 1.68 kN
Service Reaction (Rs,2) 0.82 kN
Ultimate Reaction (Ru,1) 2.12 kN
Ultimate Reaction (Ru,2) 1.03 kN

𝑀_𝑚𝑎𝑥=𝑃𝑎𝑏/𝑙

Service Moment (Ms) 3.19 kNm


Ultimate Moment (Mu) 4.02 kNm

𝑀_𝑚𝑎𝑥= 〖𝜙𝑓 _𝑦 𝑆 〗 _𝑥⇒𝑆_𝑥=𝑀_𝑚𝑎𝑥/(𝜙𝑓_𝑦 )

Required Section Modulus (Sreq) 12.78 ×103 mm3


Provided Section Modulus (Sprovided) 569.00 ×103 mm3 Section Capacity OK

Deflection Check
For Live Load and Dead Load
Load Combination 1.0 DL + 1.0 LL
Δ_𝑚𝑎𝑥 =(𝑃𝑎𝑏(2𝑙−𝑎) √(3𝑎(2𝑙−𝑎)))/27𝑙𝐸𝐼

Modulus (E) 200000 MPa


Moment of Inertia (I) 86400000 mm4
Max Deflection (DL+LL) (Δmax) 0.49 mm
Allowable Deflection (Span/250) (ΔAllowable) 23.20 mm The deflection is OK

For Live Load Only


Load Combination 1.0 LL
Max Deflection (LL) (Δmax) 0.10 mm
Allowable Deflection (Span/500) (ΔAllowable) 11.60 mm The deflection is OK

Strength Utilisation Ratio 0.02


Servicibility Utilisation Ratio 0.02
Maximum Utilisation Ratio 0.02 Bending Moment Governs
Project
Description 32-Martin Place

Item Deflection & Stress check for Simply


Description Supported

Prepared by Noman Date 6-Aug-23

Checked by Arash Page No. 1

Capacity & Deflection of Beam UDL Acting At Length L


INPUT
Span= 4 m
Ws/LL= 1.8 kN/m
DL= 0 kN/m
Height of Load= 3.4 m
Ms= 3.44 kNm
Mu= 5.16 kNm
Fy= 250 Mpa

ANALYSIS

M=
M= Sfy
S= M
Fy
S= 20.64 x103mm3

Deflection Check
Load Combination= Ws
n= 0.85 (Check----)
m= 0.85

Max Deflection= 0.77 mm (D+L) E= 200000 Mpa


Allowable Def. L/250 I= 1.7E+07 mm4
16 mm
The deflection is OK

Allowable Def. For Live Load Only


Max Deflection= 0.77 mm
Allowable Def.= (L/250)
16 mm
The deflection is OK

Hence, 125 X 6 is ok having S= 76


Utilisation Ratio 0.27

Therefore, Bending Moment Governs The design


*E25^2*(2*(E26^3)-(6*E26^2)+E26(4+E25^2)-E25^2)

0.04799 Overall Deflection Governs The design


0.04799 Live load Deflection Governs The design
0.2715649 Bending Moment Governs The design
Project
Descriptio 32-Martin Place
n

Item
Descriptio Deflection & Stress check for Simply Supported
n

Prepared
by Noman Date 6-Aug-23

Checked Page No.


by Arash 1

Moment Capacity & Deflection of SS Beam for Point Load at Distance 'a'
INPUT
Span= 4 m
Ws/LL= 3.06666667 kN/m
DL= 0 kN/m
DL(Wt of member)= 0 kN/m
Distance of Load= 3.4 m
Ms= 1.56 kNm
Mu= 2.35 kNm
Fy= 300 Mpa

M= Sfy
S= M
Fy
S= 7.82 x103mm3

Deflection Check
Load Combination= 1.0 DL+ 0.65 LL

E= 200000 Mpa
I= 16700000 mm3
Max Deflection= 0.07 mm (D+L)
Allowable Def. L/250
16 mm
The deflection is OK

Allowable Def. For Live Load Only


Max Deflection= 0.11 mm (D+L)
Allowable Def. L/250
16 mm
The deflection is OK

Hence, 460 UB 74 is ok having S= 1460


Utilisation Ratio 0.01

Therefore, Live load Deflection Governs The design


Client: Date: 2 Aug 18
Project: 80 Collins St, Glass Box Prepared: NA
Deflection and Capacity Check for Simply Supported - Symmetric Checked: AH
Subject:
Concentrated Loads at Two Points Job No: 99999

SIMPLY SUPPORTED - SYMMETRIC TWO POINT LOAD


Input Parameters
Span (l) 4.60 m
Distance to Load (a) 1.15 m
Live Load (P) 1.00 kN
Dead Load (DL) 3.00 kN
Dead Load (Self Weight) 0.32 kN/m
Yield Strength (ɸFy) 300.0 MPa

Analysis
Service Reaction (Rs) 4.00 kN
Ultimate Reaction (Ru) 5.10 kN

𝑀_𝑚𝑎𝑥=𝑃𝑎
Service Moment (Ms) 4.60 kNm
Ultimate Moment (Mu) 5.87 kNm

𝑀_𝑚𝑎𝑥= 〖𝜙𝑓 _𝑦 𝑆 〗 _𝑥⇒𝑆_𝑥=𝑀_𝑚𝑎𝑥/(𝜙𝑓_𝑦 )

Required Section Modulus (Sreq) 19.55 ×103 mm3


Provided Section Modulus (Sprovided) 40.50 ×103 mm3 Section Capacity OK

Deflection Check
For Live Load and Dead Load
Load Combination 1.0 DL + 1.0 LL

Δ_𝑚𝑎𝑥 =𝑃𝑎/24𝐸𝐼(3𝑙^2−4𝑎^2)

Modulus (E) 200000 MPa


Moment of Inertia (I) 1800000 mm4
Max Deflection (DL+LL) (Δmax) 0.03 mm
Allowable Deflection (Span/250) (ΔAllowable) 18.40 mm The deflection is OK

For Live Load Only


Load Combination 1.0 LL
Max Deflection (LL) (Δmax) 0.01 mm
Allowable Deflection (Span/500) (ΔAllowable) 9.20 mm The deflection is OK

Strength Utilisation Ratio 0.48


Servicibility Utilisation Ratio 0
Maximum Utilisation Ratio 0.48 Bending Moment Governs
Client: Date: 2 Aug 18
Project: 80 Collins St, Glass Box Prepared: NA
Deflection and Capacity Check for Simply Supported - Partially Distributed Checked: AH
Subject:
Load at One End Job No: 99999

SIMPLY SUPPORTED - PARTIALLY DISTRIBUTED LOAD AT END


Input Parameters
Span (l) 3.20 m
Width of UDL (a) 1.50 m
Load Share 0.42
Load Width (Lw) 1.60 m
Live Load (LL) 1.50 kPa
Live Load (w) 1.01 kN/m
Dead Load (DL) 0.00 kN/m
Dead Load (Self Weight) 0.00 kN/m
Yield Strength (ɸFy) 55.7 MPa

Analysis

𝑅_1=𝑤𝑎/2𝑙(2𝑙−𝑎) 𝑅_2=(𝑤𝑎^2)/2𝑙

Service Reaction (Rs,1) 1.16 kN


Service Reaction (Rs,2) 0.35 kN
Ultimate Reaction (Ru,1) 1.74 kN
Ultimate Reaction (Ru,2) 0.53 kN

𝑀_𝑚𝑎𝑥=(𝑤𝑎^2)/2 (1−𝑎/2𝑙)^2

Maximum Moment when x = 1.15 m


Service Moment (Ms) 0.66 kNm
Ultimate Moment (Mu) 0.99 kNm

𝑀_𝑚𝑎𝑥= 〖
𝜙𝑓 _𝑦 𝑆 〗 _𝑥⇒𝑆_𝑥=𝑀_𝑚𝑎𝑥/(𝜙𝑓_𝑦 )

Required Section Modulus (Sreq) 17.76 ×103 mm3


Provided Section Modulus (Sprovided) 24.30 ×103 mm3 Section Capacity OK

Deflection Check
For Live Load and Dead Load
Load Combination 1.0 DL + 1.0 LL

Δ_𝑚𝑎𝑥 (𝑤ℎ𝑒𝑛 𝑥=𝑅_1/𝑤<𝑎)=𝑤𝑥/24𝑙𝐸𝐼 (𝑎^2 (2𝑙−𝑎)^2−2 〖


𝑎𝑥 〗^2 (2𝑙−𝑎)+ 〖
𝑙𝑥 〗^3 )

Modulus (E) 200000 MPa


Moment of Inertia (I) 1090000 mm4
Max Deflection (DL+LL) (Δmax) 2.73 mm
Allowable Deflection (Span/250) (ΔAllowable) 12.80 mm The deflection is OK

For Live Load Only


Load Combination 1.0 LL
Max Deflection (LL) (Δmax) 2.73 mm
Allowable Deflection (Span/500) (ΔAllowable) 6.40 mm The deflection is OK

Strength Utilisation Ratio 0.73


Servicibility Utilisation Ratio 0.43
Maximum Utilisation Ratio 0.73 Bending Moment Governs
Client: Date: 2 Aug 18
Project: 80 Collins St, Glass Box Prepared: NA
Checked: AH
Subject: Deflection and Capacity Check for Cantilever - Uniformly Distributed Load
Job No: 99999

CANTILEVER - UNIFORM DISTRIBUTED LOAD


Input Parameters
Span (l) 4.08 m
Load width (Lw) 1.74 m
Load Share 1.00
Live Load (LL) 2.27 kPa
Live Load (w) 3.94 kN/m
Dead Load (DL) 0.00 kPa
Dead Load 0.00 kN/m
Dead Load (Self Weight) 0.00 kN/m
Yield Strength (ɸFy) 300.0 MPa

Analysis
Service Reaction (Rs) 16.09 kN
Ultimate Reaction (Ru) 24.13 kN

𝑀_𝑚𝑎𝑥=(𝑤𝑙^2)/2

Service Moment (Ms) 32.82 kNm


Ultimate Moment (Mu) 49.23 kNm

𝑀_𝑚𝑎𝑥= 〖𝜙𝑓 _𝑦 𝑆 〗 _𝑥⇒𝑆_𝑥=𝑀_𝑚𝑎𝑥/(𝜙𝑓_𝑦 )

Required Section Modulus (Sreq) 164.09 ×103 mm3


Provided Section Modulus (Sprovided) 43.90 ×103 mm3 Section Capacity Fails

Deflection Check
For Live Load and Dead Load
Load Combination 1.0 DL + 0.65 LL

Δ_𝑚𝑎𝑥=(𝑤𝑙^4)/8𝐸𝐼

Modulus (E) 200000 MPa


Moment of Inertia (I) 1650000 mm4
Max Deflection (DL+LL) (Δmax) 269.00 mm
Allowable Deflection (Span/150) (ΔAllowable) 27.20 mm Fails in deflection

For Live Load Only


Load Combination 1.0 LL
Max Deflection (LL) (Δmax) 413.85 mm
Allowable Deflection (Span/500) (ΔAllowable) 8.16 mm Fails in deflection

Strength Utilisation Ratio 3.74


Servicibility Utilisation Ratio 50.72
Maximum Utilisation Ratio 50.72 Live Load Deflection Governs
Client: Date: 2 Aug 18
Project: 80 Collins St, Glass Box Prepared: NA
Deflection and Capacity Check for Cantilever - Concentrated Load Away Checked: AH
Subject:
from End Job No: 99999

CANTILEVER - ONE POINT LOAD AWAY FROM END


Input Parameters
Span (l) 1.80 m
Distance to Load (a) 0.60 m
Live Load (P) 3.60 kN
Dead Load (DL) 0.00 kN
Dead Load (Self Weight) 0.00 kN/m
Yield Strength (ɸFy) 315.0 MPa

Analysis
Service Reaction (Rs) 3.60 kN
Ultimate Reaction (Ru) 5.40 kN

𝑀_𝑚𝑎𝑥=𝑃(𝑙−𝑎)

Service Moment (Ms) 4.32 kNm


Ultimate Moment (Mu) 6.48 kNm

𝑀_𝑚𝑎𝑥= 〖𝜙𝑓 _𝑦 𝑆 〗 _𝑥⇒𝑆_𝑥=𝑀_𝑚𝑎𝑥/(𝜙𝑓_𝑦 )

Required Section Modulus (Sreq) 20.57 ×103 mm3


Provided Section Modulus (Sprovided) 569.00 ×103 mm3 Section Capacity OK

Deflection Check
For Live Load and Dead Load
Load Combination 1.0 DL + 1.0 LL
Δ_𝑚𝑎𝑥 =(𝑃𝑏^2)/6𝐸𝐼(2𝑙+𝑎)

Modulus (E) 200000 MPa


Moment of Inertia (I) 2080000 mm4
Max Deflection (DL+LL) (Δmax) 8.72 mm
Allowable Deflection (Span/60) (ΔAllowable) 30.00 mm The deflection is OK

For Live Load Only


Load Combination 1.0 LL
Max Deflection (LL) (Δmax) 8.72 mm
Allowable Deflection (Span/500) (ΔAllowable) 3.60 mm Fails in deflection

Strength Utilisation Ratio 0.04


Servicibility Utilisation Ratio 2.42
Maximum Utilisation Ratio 2.42 Live Load Deflection Governs
Client: Date: 2 Aug 18
Project: 80 Collins St, Glass Box Prepared: NA
Checked: AH
Subject: Deflection and Capacity Check for Cantilever - Concentrated Load at End
Job No: 99999

CANTILEVER - ONE POINT LOAD AT END


Input Parameters
Span (l) 0.50 m
Live Load (P) 0.00 kN
Dead Load (DL) 5.75 kN
Dead Load (Self Weight) 0.00 kN/m
Yield Strength (ɸFy) 315.0 MPa

Analysis
Service Reaction (Rs) 5.75 kN
Ultimate Reaction (Ru) 6.90 kN

𝑀_𝑚𝑎𝑥=𝑃𝑙)

Service Moment (Ms) 2.88 kNm


Ultimate Moment (Mu) 3.45 kNm

𝑀_𝑚𝑎𝑥= 〖𝜙𝑓 _𝑦 𝑆 〗 _𝑥⇒𝑆_𝑥=𝑀_𝑚𝑎𝑥/(𝜙𝑓_𝑦 )

Required Section Modulus (Sreq) 10.95 ×103 mm3


Provided Section Modulus (Sprovided) 569.00 ×103 mm3 Section Capacity OK

Deflection Check
For Live Load and Dead Load
Load Combination 1.0 DL + 1.0 LL

Δ_𝑚𝑎𝑥 =(𝑃𝑙^3)/3𝐸𝐼

Modulus (E) 200000 MPa


Moment of Inertia (I) 229000 mm4
Max Deflection (DL+LL) (Δmax) 5.23 mm
Allowable Deflection (Span/150) (ΔAllowable) 3.33 mm Fails in deflection

For Live Load Only


Load Combination 1.0 LL
Max Deflection (LL) (Δmax) 0.00 mm
Allowable Deflection (Span/500) (ΔAllowable) 1.00 mm The deflection is OK

Strength Utilisation Ratio 0.02


Servicibility Utilisation Ratio 1.57
Maximum Utilisation Ratio 1.57 Overall Deflection Governs