Professional Documents
Culture Documents
CB 1658 Combined
CB 1658 Combined
CB 1658 Combined
K K
2
7 7.8 8.4 9 A301 12.6 14
J J
22' - 6" 15' - 8" 14' - 10" 54' - 0" 6' - 2"
H H
A1 A3
A2 A4
22' - 0"
B1 B3
B2 B4
C1
C2 F3
MECHANICAL
E1 E3 E5 F4
4980 F1
E2 E4 E6 F2 F5
G2 G4
G1 G3 G5
G6
G H G
NORTH
Department of Administration
11' - 0"
F 23 0000-06A F
4980.1
State of Wisconsin
9 11 9
A709 A590 A709
MAX
1' - 0"
4"
MIR
K.5
4800C.1
3' - 6" 3' - 6" 3' - 6" 3' - 6" 3' - 6" 1
17' - 6"
VESTIBULE
K.7
Madison, WI 53706
11' - 0"
A3C
E E
4800D.1
1
STAIR 6
4800C
D D
Department of Administration
Madison, WI
Sheet Title:
Revisions:
No. Date Description
BD 02/10/2021 BID DOCUMENT
B B
SYMBOL LEGEND SHEET KEYNOTES SPECIFICATION KEYNOTES GENERAL NOTES - FLOOR PLANS
AWXX INTERIOR ARCHITECTURAL GLAZED WALL 05 52 13.A01 1 - 1/2" DIA ROOF GUARDRAIL, GALVANIZED AND PAINTED 1 REFER TO G100 SERIES FOR LIFE SAFETY 10 REFER TO A820 SERIES FOR FOR INTERIOR 17 REFER T OAV (V SERIES) DRAWINGS AND
1-HOUR FIRE RATING LP LOW POINT OF TAPERED INSULATION 23 0000-06A AIR HANDLING UNIT (AHU) - SEE HVAC DRAWINGS INFORMATION. REFER T OVOLUME 2B FOR HTE A200 ARCHITECTURAL WALL (AW) ELEVATIONS, DOOR AND SPECIFICATIONSFOR ADDITIONAL SCOPE PERTAINING
SFXX INTERIOR STOREFRONT SYSTEM ABOVE SLAB OR DECK THRU A900 SERIES DRAWINGS OPENING TYPES AND TO GPC (GENERAL PRIME CONTRACTOR). GPC TO
2-HOUR FIRE RATING
2 REFER TO A001 SERIES FOR ARCHITECTURAL GENERAL DETAILS. COORDINATEWITH DIV. 26 INSTALLER AND AV
NON-RATED SMOKE BARRIER OR FRXX FIRE RESISTANT GLAZING SYSTEM ROOF PAVERS NOTES, ABBREVIATIONS, AND LEGENDS. 11 REFER TO Q130 SERIES DRAWINGS FOR LOCATION AND INSTALLER TO DETERMINE FULL SCOPE
PARTITION 3 REFER TO A100 SERIES FOR OVERALL BUILDING DETAILS OF ACCESS CONTROL. RESPONSIBILITIY AND COORDINATION OF INSTALLATION
FD FLOOR DRAIN - REFER TO DETAILS ON SHEET A750
AED1 - ZOLL AED SEMI-RECESSED WALL CABINET. GEOMETRY. 12 REFER TO V100 SERIES FOR LOCATION OF LED FLAT 18 REFER TO SHEET A630 FOR TYPICAL MOUNTING 0' 2' 4' 6'
FOR ELEVATED FLOOR DRAINS ROOF WALKWAY MAT Graphic
2 MODEL 8000-0814 OFCI 4 REFER TO A130 SERIES FOR ROOM FINISHES, MARKER PANELS. HEIGHTS.
AED2 - ZOLL AED STANDARD WALL CABINET. FS FLOOR SINK Scale
BOARDS, CORNER GUARD LOCATIONS AND WALL 13 REFER TO MEP DRAWINGS FOR LOCATION OF SLAB 19 MASONRY CONTROL JOINTS SEE 6/S541. CONTROL Scale: 1/4"=1'-0"
MODEL 8000-0817 OFCI EXPANSION JOINT PROTECTION. OPENINGS, PIPE PENETRATIONS, DRAINS, FLOOR JOINT LOCATIONS CONCEPTUALLY SHOWN,
TD TRENCH DRAIN COORDINATE FINAL SPECIFIC LOCATION WITH CMU DFD
BRACED FRAME 5 REFER TO A500 SERIES FOR TYPICAL ROOF DETAILS. CLEAN OUTS & ELECTRICAL FLOOR BOXES. Number 18H2H
TV FLAT PANEL MONITOR BLOCK COURSING. LOCATE CJ 4'-0" MIN. AWAY FROM
FB FLOOR BOX 6 REFER TO A630 FOR TYPICAL MOUNTING HEIGHT 14 REFER TO STRUCTURAL PLANS FOR LOCATIONS OF
CJ CONTROL JOINT DEPRESSED SLAB AND RAISED EQUIPMENT PADS. LINTEL BEARINGS, INTERSECTIONS OR CORNERS.
DETAILS AND ENLARGED TOILET ROOM PLANS AND Set
A FIRE EXTINGUISHER CABINET SEMI-RECESSED
ROOF SAFETY
TIE-BACK
MB MARKER BOARD
ELEVATIONS COORDINATE LOCATION. 20 REFER TO THE L SERIES WALL ELEVATION DRAWINGS Type CD A
FEC1 FOR THE LOCATION OF THE WALL MOUNTED CLOCKS.
7 REFER TO A750 SERIES FOR DRAWINGS MATERIAL 15 LOCATE THE DOOR FRAME 4" FROM FINISH FACEOF THE
PP PUSH PLATE ACTIVATION 21 REFER TO THE L SERIES WALL ELEVATION DRAWINGS
FE1 FIRE EXTINGUISHER - OFOI/ WALL BRACKED OFCI WALL INTERSECTION UNO. Date
7/20/2023 4:43:01 PM
1 2 3 4 5 6 7 8 9 10
M O Q M O Q
1 2 1.4 3 4 5 6 7 8 9 10
3 5
A602 A602 6
A602 6
134' - 0"
A602 Level 3
K K
05 12 13.A02
4 Sim 05 51 13.A07
A703
1 8' - 8" 05 12 13.A02
05 12 13.A19 1 2
EQ EQ EQ 05 73 00.A01 14' - 9 1/4"
A701
1' - 5 1/2" 4' - 0" 3' - 6" EQ EQ EQ EQ EQ
06 41 00.A02 8
A701
J 05 12 13.A02
A701
J
118' - 0" 1 118' - 0"
Level 2 Level 2
118' - 0"
9 EQUAL RISERS
P0E P0E P0E Level 2
P0E
2' - 5"
1 P0E 1
C3A
1
05 12 13.A08
5' - 2" 8' - 3 3/4"
2 EQUAL BAYS 3 EQUAL BAYS
H H
20 EQUAL RISERS
15' - 7"
.
2 EQUAL RISERS
1
7 6
A701
A701 A701 A1 A3
.
A2 A4
B1 B3
B2 B4
C1
100' - 0" 100' - 0" C2 F3
Level 1 Level 1 E1 E3 E5 F4
100' - 0" F1
E2 E4 E6 F2 F5
Level 1 G2 G4
G1 G3 G5
18' - 5" G6
6 EQUAL BAYS
G H G
STAIR 02 SECTION 03 STAIR 02 SECTION 02 5
A701
3
3 1/4" = 1'-0"
M Q
6' - 8" 7' - 4"
O2' - 2"
8 TREADS @ 11"
18 13 6
Department of Administration
AF 109
F F
5
A602
4' - 8"
12
State of Wisconsin
17 A704
1 A704
2 2.3 2.3
7
10' - 10"
1' - 6"
A704
R
4'
-8
"
3
'-8
"
4' - 8"
R4
A602
05 12 13.A08
20 16 11
A704 A704 A704
STAIR 02 LEVEL 02
2
D D
M 6 Q
1 TREAD
@ 11"
A602
Madison, Wisconsin
05 73 00.A08
2.3
2
2
C A704 C
9"
Madison, WI
3
R4
Sheet Title:
4' - 8"
'-8
A602
"
1.4 Revisions:
No. Date Description
BD 02/10/2021 BID DOCUMENT
1 06/09/2023 CB 1633
2 07/21/2023 CB 1658
B B
SYMBOL LEGEND SHEET KEYNOTES SPECIFICATION KEYNOTES GENERAL NOTES - STAIRS
AF 109 LINE INDICATES EDGE OF CONCRETE BELOW 05 12 13.A02 2" X 2" SQUARE STEEL POST (CATEGORY 1 AESS) WELDED TO STEEL 1 ALL FLOOR ELEVATIONS ARE TO TOP OF SLAB, UNLESS NOTED OTHERWISE
STRINGER (PT 3) 2 ALL STEEL TO BE PAINTED, UNLESS NOTED OTHERWISE
05 12 13.A08 HSS TUBE STEEL (CATEGORY 1 AESS) SEE STRUCTURAL. (PT-3) 3 REFER TO SPECIFICATIONS FOR (AESS) ARCHITECTURAL EXPOSED STRUCTURAL STEEL REQUIREMENTS
05 12 13.A19 2" X 1/2" STEEL INTERMEDIATE POST (CATEGORY 1 AESS) WELDED TO 4 REFER TO TERRAZZO MANUFACTURERS GUIDELINES FOR INSTALLING AND PRODUCING ALL TERRAZZO TREADS
CENTER OF STEEL STRINGER (PT-3) 5 ALL AXONOMETRIC VIEWS ARE FOR REFERENCE ONLY AND SHOULD NOT BE DIMENSIONED FOR CONSTRUCTION
6 ALL HANDRAILS ARE TO BE +3' - 0" ABOVE FINISH FLOOR
05 51 13.A07 1 1/2" DIA PAINTED STEEL HANDRAIL (PT3) 7 ALL GUARDRAILS TO BE +3' - 6" ABOVE FINISH FLOOR 0' 2' 4' 6'
05 73 00.A01 3/16" STAINLESS STEEL CABLES SPACED @ 3" O.C. TYPICAL Graphic
8 REFER TO PLAN VIEWS FOR ALL HORIZONTAL CONTROL DIMENSIONS
Scale Scale: 1/4"=1'-0"
05 73 00.A08 RETURN HANDRAIL TO GUARDRAIL POST 2 9 REFER TO SETCION VIEWS FOR ALL VERTICAL CONTROL DIMENSIONS
06 41 00.A02 3" X 3/4" CONTINUOUS WOOD TOP RAIL (WD1) BLIND FASTEN TO STEEL 10 REFER TO EXTERIOR ELEVATIONS FOR ALL EXTERIOR GLAZING TYPES
DFD
PLATE FROM UNDERSIDE @ 18" O.C. AS SHOWN 11 REFER TO A130 SERIES FOR FINISHES 18H2H
Number
Set
A Type CD A
Date
7/20/2023 4:22:01 PM
Issued 05/04/2021
Sheet
Number A602
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
K K
3 2
4 A612 A612
3
18
A705 A604 5
J J
R R
3700C.1
B6N
4' - 0"
R4 1 1
1 '- 1 A604
0"
B6N B6N
1' - 0"
17 12
A705 A705
2
4' - 0"
A604
H H
2
05 1201
13' - 8" 4' - 0"
16 14 TREADS @ 11" TYP
A705
8
A517
A1 A3
SIM A2 A4
STAIR 03 LEVEL 03
B1 B3
B2 B4
3 1/4" = 1'-0" C1
C2 F3
E1 E3 E5 F4
F1
E2 E4 E6 F2 F5
G2 G4
G1 G3 G5
G6
2
G 08 4435-01A 3 H G
8 3 A604
4 A705 A612 2 5 NORTH
A61216' - 6"
2700C.1
1
B6N
'-0
A604
"
Department of Administration
1
B6N
F 1 1 F
0"
B6N C3A
-
2
4'
R
A604
State of Wisconsin
2
2
2
2 6 7
A705 A705
05 51 13.A01
05 51 13.A07
3
5 05 73 00.A09
A604
2
A3D 1 A6D
1 1 B6N
B6N 2
A3D
4' - 0"
1
Madison, Wisconsin
2
A705
C STAIR 03 LEVEL 01 C
1
Madison, WI
1/4" = 1'-0"
Sheet Title:
STAIR 05 AXONOMETRIC
4
Revisions:
No. Date Description
BD 02/10/2021 BID DOCUMENT
1 09/24/2021 CB1067
2 05/19/2023 CB 1596
3 07/21/2023 CB 1658
B B
SYMBOL LEGEND SHEET KEYNOTES SPECIFICATION KEYNOTES GENERAL NOTES - STAIRS
AE128 PROVIDE 2 HOUR FIRE BARRIER SOFFIT AT UNDERSIDE OF STAIR 05 51 13.A01 SEALED CONCRETE FILLED PAN TREAD WITH ABRASIVE NOSING 1 ALL FLOOR ELEVATIONS ARE TO TOP OF SLAB, UNLESS NOTED OTHERWISE
05 51 13.A07 1 1/2" DIA PAINTED STEEL HANDRAIL (PT3) 2 ALL STEEL TO BE PAINTED, UNLESS NOTED OTHERWISE
05 51 13.A13 PAINTED STEEL STRINGER (PT3) 3 REFER TO SPECIFICATIONS FOR (AESS) ARCHITECTURAL EXPOSED STRUCTURAL STEEL REQUIREMENTS
4 REFER TO TERRAZZO MANUFACTURERS GUIDELINES FOR INSTALLING AND PRODUCING ALL TERRAZZO TREADS
05 73 00.A09 ATTACH HANDRAIL BRACKET TO FINISHED FACE OF WALL 3
5 ALL AXONOMETRIC VIEWS ARE FOR REFERENCE ONLY AND SHOULD NOT BE DIMENSIONED FOR CONSTRUCTION
05 1201 STRUCTURAL STEEL BEAM - REFER TO THE STRUCTURAL S110 DRAWINGS 6 ALL HANDRAILS ARE TO BE +3' - 0" ABOVE FINISH FLOOR
SERIES 7 ALL GUARDRAILS TO BE +3' - 6" ABOVE FINISH FLOOR 0' 2' 4' 6'
Graphic
08 4435-01A 90 MINUTE FIRE RATED STEEL WINDOW FRAME ASSEMBLY 8 REFER TO PLAN VIEWS FOR ALL HORIZONTAL CONTROL DIMENSIONS
Scale Scale: 1/4"=1'-0"
9 REFER TO SETCION VIEWS FOR ALL VERTICAL CONTROL DIMENSIONS
10 REFER TO EXTERIOR ELEVATIONS FOR ALL EXTERIOR GLAZING TYPES
DFD
11 REFER TO A130 SERIES FOR FINISHES 18H2H
Number
2
Set
A Type CD A
Date
7/20/2023 4:22:17 PM
Issued 05/04/2021
Sheet
Number A603
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
K K
J 5 4.3 4 J
T R 6 5 4.3 4
1 1 1
1
2 1 3 2
3 3
A604 A604 2 3 A604 A612
A604 A612
A612 A612 AE160
AE160
11' - 11"
A1 A3
3 EQUAL BAYS
A2 A4
05 51 13.A11 B1 B3
B2 B4
05 51 13.A07 C1
16' - 0"
C2 F3
2 05 51 13.A10 E1 E3 E5 F4
F1
E2 E4 E6 F2 F5
05 51 13.A16 G2 G4
8 G1 G3 G5
A709 G6
05 51 13.A01
G 2 H G
05 1201
A708
4 NORTH
A708
08 4413-05E
13 EQUAL RISERS
13' - 6 1/4" 4' - 11"
Department of Administration
6
F F
16' - 0"
1 A708
16
A843
15 EQUAL RISERS
State of Wisconsin
15 EQUAL RISERS
1
05 51 13.A10
.
A708
1 05 51 13.A13
15
A843 T p
io
n
cC
te 7
0
2
ytrih
g
18 EQUAL RISERS
3
A708
.
7 AE128
3
18' - 0"
A708
A515
9
A708
13 EQUAL RISERS
8 1
7' - 6 5/8"
A708
D D
Department of Administration
11' - 10 1/2" 3' - 2" 16' - 4 3/4"
3 EQUAL SPACES 4 EQUAL SPACES
Madison, Wisconsin
STAIR 03 SECTION 03 STAIR 03 SECTION 02 STAIR 03 SECTION 01
3 1/4" = 1'-0" 2 1/4" = 1'-0" 1 1/4" = 1'-0" C
C
Madison, WI
Sheet Title:
Revisions:
No. Date Description
BD 02/10/2021 BID DOCUMENT
1 05/19/2023 CB 1596
2 07/21/2023 CB 1658
B B
SYMBOL LEGEND SHEET KEYNOTES SPECIFICATION KEYNOTES GENERAL NOTES - STAIRS
AE128 PROVIDE 2 HOUR FIRE BARRIER SOFFIT AT UNDERSIDE OF STAIR 05 51 13.A01 SEALED CONCRETE FILLED PAN TREAD WITH ABRASIVE NOSING 1 ALL FLOOR ELEVATIONS ARE TO TOP OF SLAB, UNLESS NOTED OTHERWISE
AE160 THIS PORTION OF ROOF DECK IS TO BE REMOVABLE FOR ACCESSING 05 51 13.A07 1 1/2" DIA PAINTED STEEL HANDRAIL (PT3) 2 ALL STEEL TO BE PAINTED, UNLESS NOTED OTHERWISE
FUTURE PHASE. SEE STRUCTURAL FOR DIMENSIONS AND DETAILS 05 51 13.A10 5/8" DIA PAINTED STEEL ROD WELDED TO VERTICAL POSTS (PT3) 3 REFER TO SPECIFICATIONS FOR (AESS) ARCHITECTURAL EXPOSED STRUCTURAL STEEL REQUIREMENTS
4 REFER TO TERRAZZO MANUFACTURERS GUIDELINES FOR INSTALLING AND PRODUCING ALL TERRAZZO TREADS
05 51 13.A11 3" X 1/2" PAINTED STEEL GUARDRAIL WELDED TO VERTICAL POSTS (PT3)
5 ALL AXONOMETRIC VIEWS ARE FOR REFERENCE ONLY AND SHOULD NOT BE DIMENSIONED FOR CONSTRUCTION
05 51 13.A13 PAINTED STEEL STRINGER (PT3) 6 ALL HANDRAILS ARE TO BE +3' - 0" ABOVE FINISH FLOOR
05 51 13.A16 2" X 2" PAINTED STEEL STANCHION POST WELDED TO CENTER OF 7 ALL GUARDRAILS TO BE +3' - 6" ABOVE FINISH FLOOR 0' 2' 4' 6'
Graphic
STRINGER (PT3) 8 REFER TO PLAN VIEWS FOR ALL HORIZONTAL CONTROL DIMENSIONS
Scale Scale: 1/4"=1'-0"
05 1201 STRUCTURAL STEEL BEAM - REFER TO THE STRUCTURAL S110 DRAWINGS 9 REFER TO SETCION VIEWS FOR ALL VERTICAL CONTROL DIMENSIONS
SERIES 10 REFER TO EXTERIOR ELEVATIONS FOR ALL EXTERIOR GLAZING TYPES
DFD
08 4413-05E EXTRUDED AL. SILL EXTENSION BY CURTAIN WALL INSTALLER 11 REFER TO A130 SERIES FOR FINISHES 18H2H
1 Number
2
Set
A Type CD A
Date
7/20/2023 4:22:23 PM
Issued 05/04/2021
Sheet
Number A604
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
K K
J J
12 13 14 12 13 14 12 13 14 12 13 14 12 13 14 12 13.9 14
3 3 3 1 3 1 3 1 3 3
H A607 A607 A607 A607 A607 A607 A607 A607 A607 A607
H
A1 A3
A2 A4
B1 B3
B2 B4
C1
AB A
B A
B A
B AB A
B B
A C2 F3
10 E1 E3 E5 F1
F4
A706 E2 E4 E6 F2 F5
G2 G4
G1 G3 G5
G6
G H G
1 1/2"
0"
1' - 3"
C3C A189 C3C NORTH
10' - 0"
C3C C3C A189
AF 109 10' - 0"
5' - 4"
5' - 4"
C3C 2 10' - 0" 4' - 0" 2' - 0" 4' - 0"
2 2 2 2 2 05 51 13.A04 4' - 0" 2' - 0" 4' - 0"
4' - 0" 2' - 0" 4' - 0"
4' - 0"
4' - 0"
A607 A607 10' - 0" A607 A607 A607 0"
5' - 1"
5' - 1"
'-
1' - 1"
4' - 0" 2' - 0" 4' - 0" " 4
'-0
4' - 0"
R
R4
1' - 0 1/2"
C3C "
'-0
5 1/2"
DN UP UP
R4
2' - 0 1/2"
UP
3 TREADS @ 11"
4' - 2 1/2"
1' - 2"
9 TREADS @ 11"
DN
Department of Administration
10' - 0"
10 TREADS @ 11"
9 TREADS @ 11"
4' - 2"
8' - 3"
UP
8' - 3"
9' - 2"
F
6 TREADS @ 11"
05 51 13.A01
F R 3' -
8"
C.2 C.2 C.2 C.2 C.2 C.2
5' - 6"
13 TREADS @ 11"
1' - 4"
13 TREADS @ 11"
05 51 13.A07
13 TREADS @ 11"
UP
11' - 11"
11' - 11"
State of Wisconsin
11' - 11"
7 TREADS @ 11"
1' - 10"
6' - 5"
R 4 10 1/2"
05 51 13.A07
5' - 8 1/2"
5' - 8 1/2"
5' - 2 1/2"
05 73 00.A09 05 51 13.A13
"
"
'-0
2
'-0
05 73 00.A09 2
3' - 4"
R4
3
C3C C3C
C.6 C.6 C.6 C.6 C.6 C.6 C.6
UP
12' - 5"
DN 3
DN DN UP
4"
17' - 5"
3 C3C
0" - 0"
'- 4'
E
"
1
'-0
E R
4 R
2
7' - 5"
AF 109
6' - 11"
6' - 11"
7' - 2"
R4
14 2100-03A
9' - 1"
3900A.1 2900A.1 A192
14 2100-03A
14 2100-03A AF 114
DN 10' - 0"
D AF 109 D
AF 114
Department of Administration
Madison, Wisconsin
C C
Madison, WI
Sheet Title:
STAIR 05 @ LEVEL 01 TO 02 STAIR 05 @ LEVEL 01 TO 02 STAIR 05 @ LEVEL 00 to 01 STAIR 05 @ LEVEL 00 to 01
STAIR 05 @ LEVEL 04 STAIR 05 @ LEVEL 03 TO 04 STAIR 05 @ LEVEL 02 TO 03 UPPER 2 RUNS OF 3 RUN STAIR LOWER RUN OF 3 RUN STAIR UPPER RUN OF 3 RUN STAIR LOWER 2 RUNS OF 3 RUN STAIR
7 1/4" = 1'-0" 6 1/4" = 1'-0" 5 1/4" = 1'-0" 4 1/4" = 1'-0" 3 1/4" = 1'-0" 2 1/4" = 1'-0" 1 1/4" = 1'-0" Revisions:
No. Date Description
BD 02/10/2021 BID DOCUMENT
1 09/24/2021 CB1067
2 05/19/2023 CB 1596
3 07/21/2023 CB 1658
B B
SYMBOL LEGEND SHEET KEYNOTES SPECIFICATION KEYNOTES GENERAL NOTES - STAIRS
A189 LIFT & SHIFT ACCESS PANEL BY MANUFACTURER, SEE SPECIFICATION 09 05 51 13.A01 SEALED CONCRETE FILLED PAN TREAD WITH ABRASIVE NOSING 1 ALL FLOOR ELEVATIONS ARE TO TOP OF SLAB, UNLESS NOTED OTHERWISE
5429 05 51 13.A04 2" X 1" X 1/4" STEEL GATE FRAME (PT3) MITER CORNERS AND GRIND 2 ALL STEEL TO BE PAINTED, UNLESS NOTED OTHERWISE
A192 COORDINATE FRAMING OF THE CABINET UNIT HEATER WITH THE SMOOTH 3 REFER TO SPECIFICATIONS FOR (AESS) ARCHITECTURAL EXPOSED STRUCTURAL STEEL REQUIREMENTS
MECHANICAL CONTRACTOR. 2 05 51 13.A07 1 1/2" DIA PAINTED STEEL HANDRAIL (PT3) 4 REFER TO TERRAZZO MANUFACTURERS GUIDELINES FOR INSTALLING AND PRODUCING ALL TERRAZZO TREADS
AF 109 LINE INDICATES EDGE OF CONCRETE BELOW 5 ALL AXONOMETRIC VIEWS ARE FOR REFERENCE ONLY AND SHOULD NOT BE DIMENSIONED FOR CONSTRUCTION
05 51 13.A13 PAINTED STEEL STRINGER (PT3) 6 ALL HANDRAILS ARE TO BE +3' - 0" ABOVE FINISH FLOOR
AF 114 RIDEABLE LIFT MANUFACTURER TO PROVIDE ALL CODE COMPLIANT GATES, 05 73 00.A09 ATTACH HANDRAIL BRACKET TO FINISHED FACE OF WALL 7 ALL GUARDRAILS TO BE +3' - 6" ABOVE FINISH FLOOR 0' 2' 4' 6'
CAGING, HARDWARE AND SIGNAGE ASSOCIATED WITH WITH LIFT 3 Graphic
14 2100-03A RIDEABLE LIFT 8 REFER TO PLAN VIEWS FOR ALL HORIZONTAL CONTROL DIMENSIONS
Scale Scale: 1/4"=1'-0"
9 REFER TO SETCION VIEWS FOR ALL VERTICAL CONTROL DIMENSIONS
10 REFER TO EXTERIOR ELEVATIONS FOR ALL EXTERIOR GLAZING TYPES
DFD
11 REFER TO A130 SERIES FOR FINISHES 18H2H
2 Number
Set
A Type CD A
Date
7/20/2023 4:32:45 PM
Issued 05/04/2021
Sheet
Number A606
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
5
8 A609
K K
VESTIBULE
4800G
K.7
A3C
M10M
J STAIR 6 J
4 4800C
A609
4' - 0"
L 4 5
A609 8 A609
05 51 13.A01
2' - 9"
L.3 L.3 4' - 7 1/2"
A3D 3 TREADS @11"
05 51 13.A07
15 TREADS @11"
H H
13' - 9"
05 73 00.A07
5
2 K6N
4' - 0"
A623 B3Nt
3 TREADS @ 11"
R
5' - 1"
4'
-0
"
2' - 9"
A1 A3
4' - 0" A2 A4
05 73 00.A08 B1 B3
B2 B4
2
C1
4' - 0"
O E1 E3
C2
E5
F3
F4
F1
E2 E4 E6 F2 F5
4' - 11"
G2 G4
O
4' - 5 1/2"
"
R
R
-0
G1 G3 G5
4'
4'
4'
4' - 0"
G6
-0
-
1 1
R
0"
"
G A609 A609
H G
NORTH
C3D
Department of Administration
NTS 1/4" = 1'-0" 1/4" = 1'-0"
F K.5 K.7 L L.3 N K.5 K.7 L L.3 7.8 7.9 8 F
State of Wisconsin
1 4 5
A609 A609 A609
1
E E
8
05 51 13.A16
A708
4 EQUAL RISERS
05 51 13.A10
Department of Administration
4 EQUAL RISERS
4 EQUAL RISERS
Madison, Wisconsin
14' - 7"
4 EQUAL BAYS
.
C C
Madison, WI
.
Sheet Title:
134' - 0" 134' - 0" 134' - 0"
Level 3 Level 3 Level 3
05 1202
05 51 13.A13 Revisions:
No. Date Description
B B
SYMBOL LEGEND SHEET KEYNOTES SPECIFICATION KEYNOTES GENERAL NOTES - STAIRS
05 51 13.A01 SEALED CONCRETE FILLED PAN TREAD WITH ABRASIVE NOSING 1 ALL FLOOR ELEVATIONS ARE TO TOP OF SLAB, UNLESS NOTED OTHERWISE
05 51 13.A02 2" X 4" HSS (CATEGORY 1 AESS), RETURN TO STRINGER BEYOND 2 ALL STEEL TO BE PAINTED, UNLESS NOTED OTHERWISE
05 51 13.A07 1 1/2" DIA PAINTED STEEL HANDRAIL (PT3) 3 REFER TO SPECIFICATIONS FOR (AESS) ARCHITECTURAL EXPOSED STRUCTURAL STEEL REQUIREMENTS
4 REFER TO TERRAZZO MANUFACTURERS GUIDELINES FOR INSTALLING AND PRODUCING ALL TERRAZZO TREADS
05 51 13.A10 5/8" DIA PAINTED STEEL ROD WELDED TO VERTICAL POSTS (PT3)
5 ALL AXONOMETRIC VIEWS ARE FOR REFERENCE ONLY AND SHOULD NOT BE DIMENSIONED FOR CONSTRUCTION
05 51 13.A11 3" X 1/2" PAINTED STEEL GUARDRAIL WELDED TO VERTICAL POSTS (PT3) 6 ALL HANDRAILS ARE TO BE +3' - 0" ABOVE FINISH FLOOR
05 51 13.A13 PAINTED STEEL STRINGER (PT3) 7 ALL GUARDRAILS TO BE +3' - 6" ABOVE FINISH FLOOR 0' 2' 4' 6'
Graphic
05 51 13.A16 2" X 2" PAINTED STEEL STANCHION POST WELDED TO CENTER OF 8 REFER TO PLAN VIEWS FOR ALL HORIZONTAL CONTROL DIMENSIONS
Scale Scale: 1/4"=1'-0"
STRINGER (PT3) 9 REFER TO SETCION VIEWS FOR ALL VERTICAL CONTROL DIMENSIONS
05 73 00.A07 RETURN HANDRAIL TO WALL 10 REFER TO EXTERIOR ELEVATIONS FOR ALL EXTERIOR GLAZING TYPES
DFD
11 REFER TO A130 SERIES FOR FINISHES 18H2H
05 73 00.A08 RETURN HANDRAIL TO GUARDRAIL POST 2 Number
05 1202 STRUCTURAL STEEL POST - REFER TO THE STRUCTURAL DRAWINGS S110
Set
A
DRAWINGS SERIES
Type CD A
Date
7/20/2023 4:33:54 PM
Issued 05/04/2021
Sheet
Number A609
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
11 M
OPEN TO 05 73 00.A01 - 3/16" STAINLESS STEEL
05 12 13.A19 - POST B: 2" X 1/2" STEEL CABLES SPACED @ 3" O.C. TYPICAL
BELOW (CATEGORY 1 AESS) INTERMEDIATE POST
WELDED TO CENTER OF STEEL BELOW. (PT4) 05 12 13.A05 - 1/2" X 1/4" STEEL HANDRAIL
05 12 13.A08 - HSS TUBE STEEL (CATEGORY BRACKET (CATEGORY 1 AESS) WELDED
3 1/2"
06 41 00.A02 - 3" X 3/4" CONTINUOUS WOOD
TOP RAIL (WD1) MECHANICLLY FASTENED
TO STEL PLATE
05 12 13.A02 - POST A: 2" X 2" SQUARE
1" 06 41 00.A02 - 3" X 3/4" CONTINUOUS
STEEL (CATEGORY 1 AESS) POST WELDED
2"
PLAN DETAIL PLAN DETAIL AT RAILING POST NOT USED NOT USED NOT USED
25 1 1/2" = 1'-0" 20 1 1/2" = 1'-0" 15 10 5 05 73 00.A05 - DECORATIVE MTAL
11 HANDRAIL (PT4)
05 73 00.A05 - DECORATIVE MTAL
HANDRAIL (PT4) 05 73 00.A07 - RETURN HANDRAIL TO
05 73 00.A05 - DECORATIVE MTAL
1' - 11" 05 73 00.A05 - DECORATIVE MTAL WALL
05 12 13.A02 - POST A: 2" X 2" SQUARE HANDRAIL (PT4) 1
HANDRAIL (PT4)
3 1/2"
2" 11 1/2" 1/2" STEEL (CATEGORY 1 AESS) POST WELDED 06 41 00.A02 - 3" X 3/4" CONTINUOUS WOOD
11" 2" 3 1/2" TO STEEL STRINGER. PAINTED FINISH 06 41 00.A02 - 3" X 3/4" CONTINUOUS WOOD
06 41 00.A02 - 3" X 3/4" CONTINUOUS WOOD TOP RAIL (WD1) MECHANICLLY FASTENED
3" TOP RAIL (WD1) MECHANICLLY FASTENED
TOP RAIL (WD1) MECHANICLLY FASTENED TO STEEL PLATE
05 12 13.A05 - 1/2" X 1/4" STEEL TO STEL PLATE
TO STEL PLATE (CATEGORY 1 AESS) HANDRAIL BRACKET
H 2" R WELDED TO CENTER OF POST 05 12 13.A02 - POST A: 2" X 2" SQUARE 05 12 13.A02 - POST A: 2" X 2" SQUARE H
STEEL (CATEGORY 1 AESS) POST WELDED
1' - 0"
STEEL (CATEGORY 1 AESS) POST WELDED
1" TO STEEL STRINGER. PAINTED FINISH
TO STEEL STRINGER. PAINTED FINISH
2"
WELDED TO CENTER OF POST
2"
11 1/2"
05 12 13.A08 - HSS TUBE STEEL (CATEGORY
11"
OPEN TO 1 AESS) BELOW (PT4), SEE STRUCTURAL C C C C
BELOW
05 73 00.A01 - 3/16" STAINLESS STEEL 05 12 13.A02 - POST A: 2" X 2" SQUARE
STEEL (CATEGORY 1 AESS) POST WELDED 05 73 00.A01 - 3/16" STAINLESS STEEL 05 73 00.A01 - 3/16" STAINLESS STEEL
CABLES SPACED AT 3" O.C. TYPICAL
TO STEEL STRINGER. PAINTED FINISH CABLES SPACED AT 3" O.C. TYPICAL CABLES SPACED AT 3" O.C. TYPICAL
05 73 00.A01 - 3/16" STAINLESS STEEL
G 06 41 00.A02 - 3" X 3/4" CONTINUOUS WOOD 08 4413-04A - CURTAINWALL VERTICAL CABLES SPACED AT 3" O.C. TYPICAL G
TOP RAIL (WD1) MECHANICLLY FASTENED 05 73 00.A07 - RETURN HANDRAIL TO MEMBER
TO STEL PLATE WALL
1 08 8000-03E - INSULATED GLASS UNIT
TYPE IGU 5 - OKALUX GLASS
PLAN DETAIL PLAN DETAIL AT RAILING POST PLAN DETAIL AT RAILING POST PLAN DETAIL AT RAILING POST PLAN DETAIL AT RAILING POST
24 1 1/2" = 1'-0" 05 12 13.A04 - 1" X 1/2" STEEL
19 1 1/2" = 1'-0" 14 1 1/2" = 1'-0" 9 1 1/2" = 1'-0" 4 1 1/2" = 1'-0"
INTERMEDIATE POST PARALLEL TO THE
HANDRAIL (CATEGORY 1 AESS) WELDED 05 51 13.A16 - 2" X 2" PAINTED STEEL 05 73 00.A01 - 3/16" STAINLESS STEEL
9 TO CENTER OF STRINGER (PT-3) 05 51 13.A11 - 3" X 1/2" PAINTED STEEL
1/2"
STANCHION POST WELDED TO CENTER CABLES SPACED @ 3" O.C. TYPICAL
1/2"
2"
GUARDRAIL WELDED TO VERTICAL POSTS
Department of Administration
TO CENTER OF STRINGER (PT-3)
2" 3 1/2"
OF STRINGER (PT3) 05 73 00.A05 - DECORATIVE METAL
06 41 00.A02 - 3" X 3/4" CONTINUOUS SEE ELEVATIONS HANDRAIL (PT3)
F
WOOD TOP RAIL (WD1) BLIND FASTEN TO
F
STEEL PLATE FROM UNDERSIDE @ 18" O 05 73 00.A01 - 3/16" STAINLESS STEEL
08 4413-05E - EXTRUDED AL. SILL
2 1/2"1" 2" 3" 2" T O.C. AS SHOWN CABLES SPACED @ 3" O.C. TYPICAL
EXTENSION BY CURTAIN WALL INSTALLER
4"
2' - 0 19/256"
State of Wisconsin
2' - 0"
1' - 1 27/256"
CABLES SPACED AT 3" O.C. TYPICAL 06 41 00.A02 - 3" X 3/4" CONTINUOUS
EQ
EMBED ANGLE (CATEGORY 1 AESS) SEE
1' - 1"
1' - 1"
05 51 13.A16 - 2" X 2" PAINTED STEEL WOOD TOP RAIL (WD1) BLIND FASTEN TO STRUCTURAL. (PT-3)
05 12 13.A02 - POST A: 2" X 2" SQUARE
8"
6"
6"
2" 3 1/2" 2" 11 1/2" STEEL PLATE FROM UNDERSIDE @ 18"
STEEL (CATEGORY 1 AESS) POST WELDED OF STRINGER (PT3) O.C. AS SHOWN
EQ
TO STEEL STRINGER. PAINTED FINISH
4"
EDGE OF BEAM, BELOW
10"
3 1/2" 2"
05 12 13.A05 - 1/2" X 1/4" STEEL 05 73 00.A05 - DECORATIVE METAL
HANDRAIL (PT3)
Madison, WI 53706
1"
PLAN DETAIL PLAN DETAIL AT RAILING POST PLAN DETAIL AT RAILING POST PLAN DETAIL AT RAILING POST PLAN DETAIL AT RAILING POST
23 1 1/2" = 1'-0" 18 1 1/2" = 1'-0" 13 1 1/2" = 1'-0" 8 1 1/2" = 1'-0" 3 1 1/2" = 1'-0"
9 05 12 13.A01 - 2" X 1/2" STEEL
INTERMEDIATE POST PARALLEL TO THE 05 73 00.A05 - DECORATIVE METAL
HANDRAIL (PT3) 1
HANDRAIL(CATEGORY 1 AESS) WELDED
TO CENTER OF STRINGER (PT-3) 05 12 13.A05 - 1/2" X 1/4" STEEL HANDRAIL 05 73 00.A08 - RETURN HANDRAIL TO
Q 8" Q 05 73 00.A05 - DECORATIVE METAL
1 1/2"
TOP RAIL (WD1) MECHANICLLY FASTENED 06 41 00.A02 - 3" X 3/4" CONTINUOUS
HANDRAIL (PT3)
TO STEL PLATE WOOD TOP RAIL (WD1) BLIND FASTEN TO
D 3" STEEL PLATE FROM UNDERSIDE @ 18" D
R O.C. AS SHOWN
2"
1' - 4"
1 AESS) BELOW (PT4), SEE STRUCTURAL
2.3
2 1/2"
3"
1/2" 05 73 00.A03 - INVISAWARE RECEIVER
8 1/2"
2" 3 1/2" 2" 1' - 7" 2" 03 3300-01A - ARCHITECTURAL EXPOSED
3 1/2"
Department of Administration
3 1/2" 2"
05 51 13.A16 - 2" X 2" PAINTED STEEL 05 51 13.A16 - 2" X 2" PAINTED STEEL
05 51 13.A16 - 2" X 2" PAINTED STEEL
Madison, Wisconsin
05 12 13.A02 - POST A: 2" X 2" SQUARE STANCHION POST WELDED TO CENTER STANCHION POST WELDED TO CENTER FRY REGLET TDM 625-50
STEEL (CATEGORY 1 AESS) POST WELDED STANCHION POST WELDED TO CENTER
OF STRINGER (PT3) OF STRINGER (PT3)
1' - 0"
Madison, WI
WELDED TO CENTER OF POST 06 41 00.A02 - 3" X 3/4" CONTINUOUS
2" 2" 10 1/2" 2" 1/2" 1" 2" 3 1/2" 2" 1/2" (CATEGORY 1 AESS) (PT3)
WOOD TOP RAIL (WD1) BLIND FASTEN TO
Sheet Title:
05 73 00.A05 - DECORATIVE MTAL 9" STEEL PLATE FROM UNDERSIDE @ 18" 05 12 13.A09 - HSS TUBE STEEL WELD TO
HANDRAIL (PT4) O.C. AS SHOWN EMBED ANGLE (CATEGORY 1 AESS) SEE
STRUCTURAL. (PT-3)
PLAN DETAIL PLAN DETAIL AT RAILING POST PLAN DETAIL AT RAILING POST PLAN DETAIL AT RAILING POST PLAN DETAIL AT RAILING POST
22 1 1/2" = 1'-0" 17 1 1/2" = 1'-0" 12 1 1/2" = 1'-0" 7 1 1/2" = 1'-0" 2 1 1/2" = 1'-0"
Revisions:
No. Date Description
Q BD 02/10/2021 BID DOCUMENT
11 Q 1 07/21/2023 CB 1658
05 73 00.A01 - 3/16" STAINLESS STEEL
CABLES SPACED @ 3" O.C. TYPICAL
05 12 13.A05 - 1/2" X 1/4" STEEL HANDRAIL 05 73 00.A05 - DECORATIVE METAL
HANDRAIL (PT3) 05 73 00.A01 - 3/16" STAINLESS STEEL 05 12 13.A02 - 2" X 2" SQUARE STEEL POST
BRACKET (CATEGORY 1 AESS) WELDED
CABLES SPACED @ 3" O.C. TYPICAL (CATEGORY 1 AESS) WELDED TO STEEL
TO CENTER OF POST (PT3) 05 73 00.A01 - 3/16" STAINLESS STEEL
B R O CABLES SPACED @ 3" O.C. TYPICAL
STRINGER (PT 3) B
05 12 13.A09 - HSS TUBE STEEL WELD TO ROOF DRAIN LEADER, SEE PLUMBING
05 73 00.A05 - DECORATIVE METAL EMBED ANGLE (CATEGORY 1 AESS) SEE
05 12 13.A05 - 1/2" X 1/4" STEEL HANDRAIL
HANDRAIL (PT3) STRUCTURAL. (PT-3)
BRACKET (CATEGORY 1 AESS) WELDED
06 41 00.A02 - 3" X 3/4" CONTINUOUS WOOD
TO CENTER OF POST (PT3) 05 51 13.A16 - 2" X 2" PAINTED STEEL 09 2900 - GYPSUM BOARD
TOP RAIL (WD1) MECHANICLLY FASTENED
3 1/2"
TO STEL PLATE STANCHION POST WELDED TO CENTER
1" OF STRINGER (PT3)
05 12 13.A05 - 1/2" X 1/4" STEEL FRY REGLECT TDM 625-50
4"
05 12 13.A02 - 2" X 2" SQUARE STEEL POST 05 12 13.A08 - HSS TUBE STEEL Set
A 05 73 00.A01 - 3/16" STAINLESS STEEL (CATEGORY 1 AESS) WELDED TO STEEL 05 12 13.A19 - 2" X 1/2" STEEL (CATEGORY 1 AESS) SEE STRUCTURAL. Type CD A
CABLES SPACED AT 3" O.C. TYPICAL STRINGER (PT 3) INTERMEDIATE POST (CATEGORY 1 AESS) (PT-3)
Date
7/20/2023 4:23:02 PM
PLAN DETAIL PLAN DETAIL AT RAILING POST PLAN DETAIL AT RAILING POST PLAN DETAIL AT RAILING POST PLAN DETAIL AT RAILING POST Sheet
21 1 1/2" = 1'-0" 16 1 1/2" = 1'-0" 11 1 1/2" = 1'-0" 6 1 1/2" = 1'-0" 1 1 1/2" = 1'-0" Number A704
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
K K
J J
H H
G G
Department of Administration
05 51 13.A10 - 5/8" DIA PAINTED STEEL
2" 2 1/4"
2" 2 1/4"
State of Wisconsin
03 3300-01B - ARCHITECTURAL EXPOSED 03 3300-01B - ARCHITECTURAL EXPOSED
CONCRETE FACE OF BEAM, SEE STRUCT CONCRETE FACE OF BEAM, SEE STRUCT
11 1/4"
4"
6"
05 12 13.A02 - 2" X 2" SQUARE STEEL POST (PT3)
(CATEGORY 1 AESS) WELDED TO STEEL
1" 2"
2"
ROD WELDED TO VERTICAL POSTS (PT3)
1"
1' - 6"
PLAN DETAIL NOT USED PLAN DETAIL 05 73 00.A08 - RETURN HANDRAIL TO 2 NOT USED
18
AF 109 - LINE INDICATES EDGE OF
CONCRETE BELOW 13 05 51 13.A13 - PAINTED STEEL STRINGER 8 GUARDRAIL POST 3
1 1/2" = 1'-0" (PT3) 1 1/2" = 1'-0"
05 51 13.A01 - SEALED CONCRETE FILLED 05 51 13.A01 - SEALED CONCRETE FILLED
05 51 13.A01 - SEALED CONCRETE FILLED PAN TREAD WITH ABRASIVE NOSING PAN TREAD WITH ABRASIVE NOSING
05 51 13.A11 - 3" X 1/2" PAINTED STEEL
PAN TREAD WITH ABRASIVE NOSING GUARDRAIL WELDED TO VERTICAL POSTS
2" (PT3) 05 51 13.A07 - 1 1/2" DIA PAINTED STEEL 05 51 13.A11 - 3" X 1/2" PAINTED STEEL
1" 2" 10" 2" 2" 1/2" 1" HANDRAIL (PT3) GUARDRAIL WELDED TO VERTICAL POSTS
11"
05 51 13.A16 - 2" X 2" PAINTED STEEL 05 51 13.A07 - 1 1/2" DIA PAINTED STEEL
6"
1' - 3"
STANCHION POST WELDED TO CENTER HANDRAIL (PT3)
4"
05 51 13.A16 - 2" X 2" PAINTED STEEL
OF STRINGER (PT3) STANCHION POST WELDED TO CENTER 05 51 13.A16 - 2" X 2" PAINTED STEEL
STANCHION POST WELDED TO CENTER 05 73 00.A09 - ATTACH HANDRAIL
OF STRINGER (PT3) BRACKET TO FINISHED FACE OF WALL
05 51 13.A07 - 1 1/2" DIA PAINTED STEEL OF STRINGER (PT3)
HANDRAIL (PT3) 2
Department of Administration
05 51 13.A07 - 1 1/2" DIA PAINTED STEEL 05 51 13.A13 - PAINTED STEEL STRINGER
05 51 13.A13 - PAINTED STEEL STRINGER (PT3)
HANDRAIL (PT3) (PT3)
Madison, Wisconsin
05 51 13.A10 - 5/8" DIA PAINTED STEEL 2" 8 1/2" 11" C3C
ROD WELDED TO VERTICAL POSTS (PT3) 03 3300-01B - ARCHITECTURAL EXPOSED 1
05 51 13.A01 - SEALED CONCRETE FILLED
PAN TREAD WITH ABRASIVE NOSING CONCRETE FACE OF BEAM, SEE STRUCT
11 1/2"
C T T T T C
Madison, WI
05 51 13.A10 - 5/8" DIA PAINTED STEEL
ROD WELDED TO VERTICAL POSTS (PT3)
Sheet Title:
05 12 13.A09 - HSS TUBE STEEL WELD TO
EMBED ANGLE (CATEGORY 1 AESS) SEE
STRUCTURAL. (PT-3) 05 51 13.A01 - SEALED CONCRETE FILLED
PLAN DETAIL PLAN DETAIL PLAN DETAIL STAIR 05 PAN TREAD WITH ABRASIVE NOSING
PLAN DETAIL STAIR 05
17 1 1/2" = 1'-0" 12 1 1/2" = 1'-0" 7 1 1/2" = 1'-0" 2 1 1/2" = 1'-0" Revisions:
No. Date Description
BD 02/10/2021 BID DOCUMENT
05 51 13.A11 - 3" X 1/2" PAINTED STEEL 1 05/19/2023 CB 1596
GUARDRAIL WELDED TO VERTICAL POSTS 05 51 13.A01 - SEALED CONCRETE FILLED 2 07/21/2023 CB 1658
(PT3) PAN TREAD WITH ABRASIVE NOSING
05 51 13.A10 - 5/8" DIA PAINTED STEEL 05 51 13.A07 - 1 1/2" DIA PAINTED STEEL
1' - 0" 11"
ROD WELDED TO VERTICAL POSTS (PT3) HANDRAIL (PT3)
B 05 51 13.A07 - 1 1/2" DIA PAINTED STEEL 2" 8 1/2" 05 51 13.A11 - 3" X 1/2" PAINTED STEEL
B
HANDRAIL (PT3)
GUARDRAIL WELDED TO VERTICAL POSTS
(PT3)
05 12 13.A09 - HSS TUBE STEEL WELD TO
EMBED ANGLE (CATEGORY 1 AESS) SEE
STRUCTURAL. (PT-3) 05 51 13.A10 - 5/8" DIA PAINTED STEEL
05 51 13.A16 - 2" X 2" PAINTED STEEL ROD WELDED TO VERTICAL POSTS (PT3)
STANCHION POST WELDED TO CENTER
OF STRINGER (PT3)
2"
Set
A Type CD A
08 4413-01 - GLAZED ALUMINUM CURTAIN
WALL SYSTEM - CW1 Date
7/20/2023 4:23:08 PM
Issued 05/04/2021
PLAN DETAIL NOT USED PLAN DETAIL STAIR 05 NOT USED Sheet
16 1 1/2" = 1'-0" 11 6 1 1/2" = 1'-0" 1 Number A705
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
K K
J J
05 51 13.A11 - 1/2" X 2" PAINTED STEEL 05 51 13.A16 - 2" X 2" PAINTED STEEL
05 51 13.A11 - 1/2" X 2" PAINTED STEEL GUARDRAIL WELDED TO VERTICAL POSTS STANCHION POST WELDED TO CENTER
GUARDRAIL WELDED TO VERTICAL POSTS OF STRINGER (PT3)
H H
Department of Administration
PAN TREAD WITH ABRASIVE NOSING
118' - 0"
134' - 0"
Level 2
F Level 3 F
State of Wisconsin
05 51 13.A13 - PAINTED STEEL STRINGER
Department of Administration
STANCHION POST WELDED TO CENTER OF
EXTERIOR ELEVATIONS FOR GLASS STRINGER 05 51 13.A07 - 1 1/2" DIA PAINTED STEEL
TYPES HANDRAIL
Madison, Wisconsin
05 51 13.A18 - EXTEND GUARDRAIL 05 51 13.A16 - 2" X 2" PAINTED STEEL
HORIZONTALLY AND VERTICALLY DOWN, STANCHION POST WELDED TO CENTER OF
CONNECTED BACK TO GUARDRAIL POST. STRINGER
Madison, WI
4" MAX GUARDRAIL WELDED TO VERTICAL POSTS 05 51 13.A10 - 5/8" DIA PAINTED STEEL ROD
(PT3) 05 51 13.A09 - 1/2" X 1/4 " PAINTED STEEL
WELDED TO VERTICAL POSTS
3' - 6" TYPICAL
Sheet Title:
HANDRAIL BRACKET WELDED TO HANDRAIL
05 51 13.A07 - 1 1/2" DIA PAINTED STEEL 05 51 13.A10 - 5/8" DIA PAINTED STEEL ROD 05 51 13.A10 - 5/8" DIA PAINTED STEEL ROD
HANDRAIL (PT3) WELDED TO VERTICAL POSTS WELDED TO VERTICAL POSTS 05 51 13.A16 - 2" X 2" PAINTED STEEL
100' - 0" STANCHION POST WELDED TO CENTER OF
Level 1 STRINGER
Revisions:
No. Date Description
05 51 13.A16 - 2" X 2" PAINTED STEEL BD 02/10/2021 BID DOCUMENT
05 51 13.A16 - 2" X 2" PAINTED STEEL 1 07/21/2023 CB 1658
STANCHION POST WELDED TO CENTER STANCHION POST WELDED TO CENTER OF
OF STRINGER (PT3) STRINGER
05 51 13.A01 - SEALED CONCRETE FILLED 05 51 13.A10 - 5/8" DIA PAINTED STEEL ROD
PAN TREAD WITH ABRASIVE NOSING WELDED TO VERTICAL POSTS
1
Issued 05/04/2021
SECTION DETAIL SECTION DETAIL SECTION DETAIL SECTION DETAIL SECTION DETAIL Sheet
8 1 1/2" = 1'-0" 6 1 1/2" = 1'-0" 4 1 1/2" = 1'-0" 2 1 1/2" = 1'-0" 1 1 1/2" = 1'-0" Number A709
1 2 3 4 5 6 7 8 9 10