Professional Documents
Culture Documents
CM 021 236 00
CM 021 236 00
2. Standard
No leak and the finish is good.
Refer to following A. to D. and document "Typical field assembly method CM-021-231"
3. Welder
The qualified person perform welding work.
4. Note
4-1. After finish the welding all pipe, perform leak test by installation manual.
4-2. If leak is found, modify it immediately. And leak test again.
A. Grooving
45+5o or-5o
0.5--2.4mm
0.02--0.1inch
20A -- 100A
3/4 inch
--4inch
30+5o or-5o
1.0--3.5mm
0.04--0.14inch
Over 100A
Over 4inch
1/2
B. Root spacing CM-021-236-00
2.0--4.0mm
0.08--0.16inch
under 2.5mm
under 0.1inch
D. Offset
x mm
x inch
PART Offset
Cooling water under 3.2mm
pipe under 0.13inch
under 2.5mm
Other pipes under 0.1inch
2/2