CM-021-236-00

Field pipe assembly specification


1. Scope
This specification is applicable to absorption chiller pipe welding on the field.

2. Standard
No leak and the finish is good.
Refer to following A. to D. and document "Typical field assembly method CM-021-231"

3. Welder
The qualified person perform welding work.

4. Note
4-1. After finish the welding all pipe, perform leak test by installation manual.
4-2. If leak is found, modify it immediately. And leak test again.

A. Grooving

Pipe size Grooving

45+5o or-5o
0.5--2.4mm
0.02--0.1inch

20A -- 100A
3/4 inch
--4inch

30+5o or-5o
1.0--3.5mm
0.04--0.14inch

Over 100A
Over 4inch

1/2
B. Root spacing CM-021-236-00

2.0--4.0mm
0.08--0.16inch

C. Excess metal and overlap


under 3.5mm
under 0.14inch

under 2.5mm
under 0.1inch

D. Offset
x mm
x inch

PART Offset
Cooling water under 3.2mm
pipe under 0.13inch

under 2.5mm
Other pipes under 0.1inch