ENGINEERING   

DESIGN MANUAL   

   
   

 
When you need a solution for retaining walls and other landscape projects, nothing stacks up quite like Verti‐Block.  Unique 
in size, shape, and flexibility of use, Verti‐Block is an ideal solution for residential and commercial projects.  Verti‐Block 
interlocks with unique male‐and‐female design.  You will get unmatched strength with more flexibility for landscape 
applications.  The interlocking nature of Verti‐Block allows you to create curves while remaining structurally sound.  Verti‐
Block is available in a range of shapes to accommodate all of your landscape and design needs. 

MAIL:  PO BOX 2347, SANDY, UTAH, 84091 

PLANT:  16500 SOUTH 500 WEST, BLUFFDALE, UTAH, 84065 

P:  801‐571‐2028  F:  801‐606‐7786 

Verti‐Crete, LLC ® 2010 ©.  All Rights Reserved      1
 
 
Engineering Design Manual
• REINFORCED WALLS
                                       
 
 

Table Of Contents 

TECHNICAL DATA & SPECIFICATIONS ...................................................................................................................... 3­7 
PART 1:  GENERAL .............................................................................................................................................................................. 3 
PART 2:  MATERIALS ......................................................................................................................................................................... 4 
PART 3:  CONSTRUCTION OF RETAINING WALL ............................................................................................................. 5‐6 
PART 4:  QUALITY ASSURANCE ..................................................................................................................................................... 7 
 

CHART FOR SYNTEEN GEOGRID ............................................................................................................................... 8­14 
30° INTERNAL ANGLE OF FRICTION .......................................................................................................................................... 8 
35° INTERNAL ANGLE OF FRICTION ................................................................................................................................... 9‐11 
40° INTERNAL ANGLE OF FRICTION ................................................................................................................................ 12‐14 
 
DRAWINGS ..................................................................................................................................................................... 15­17 
INDIVIDUAL BLOCK DETAILS ..................................................................................................................................................... 15 
RETAINING WALL SECTION ........................................................................................................................................................ 16 

GEOGRID CONNECTION DETAILS ............................................................................................................................................. 17 

   

Verti‐Crete, LLC ® 2010 ©.  All Rights Reserved      2
 
Engineering Design Manual
• REINFORCED WALLS
                                       
 

Technical Data & Specifications 

PART 1:  GENERAL 

1.01   Scope of Work  
A. Work includes furnishing and installing precast concrete retaining wall blocks to the lines and 
grades allocated within the specified construction drawings herein. 
B. The contractor is solely responsible for the means and methods of construction as well as safety of 
workers and of the public.   
 
1.02   Reference Standards  
A. ASTM C39:  Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens. 
B. ASTM C94:  Standard Test Method for Ready‐Mixed Concrete. 
C. ASTM C136:  Standard Test Method for Sieve Analysis of Fine and Coarse Aggregate. 
D. ASTM C1372:  Standard Test Method for Segmental Retaining Wall Units.  
E. ASTM D698:  Standard Test Method for Laboratory Compaction Characteristics of Soil Using 
Standard Effort. 
F. ASTM D1557:  Standard Test Method for Laboratory Compaction Characteristics of Soil Using 
Modified Effort. 
G. ASTM D4632:  Standard Test Method for Grab Breaking Load and Elongation of Geotextiles. 
H. ASTM D6638:  Standard Test Method for Determining Connection Strength Between Geosynthetic 
Reinforcement and Segmental Concrete Units. 
I. ASTM D6916:  Standard Test Method for Determining the Shear Strength Between Segmental 
Concrete Units.  
J. NCMA’s Design Manual for Segmental Retaining Walls (2nd Edition). 
 
1.03   Delivery, Storage, and Handling  
A. Contractor shall check the materials upon delivery to assure proper material has been received. 
B. Contractor shall prevent excessive mud, wet concrete, and like substances from adhering to the 
Verti‐Block units.  
C. Contractor shall protect the materials from damage.  Damaged material shall not be incorporated in 
the wall or surrounding reinforced soil embankments. 
D. Exposed faces of precast concrete retaining wall blocks shall be reasonably free of large chips, 
cracks, or stains when viewed from a distance of 10 feet.  
 
  
   

Verti‐Crete, LLC ® 2010 ©.  All Rights Reserved      3
 
Engineering Design Manual
• REINFORCED WALLS
                                       
 
 
Technical Data & Specifications 

PART 2:  MATERIALS 

2.01   Wall Units  
A. Precast concrete retaining wall blocks shall be Verti‐Block units as produced by a licensed Verti‐
Block manufacturer.   
B. Exterior precast concrete block dimensions shall be uniform and consistent.  Maximum dimensional 
tolerances shall be within 1 percent excluding the architectural surface.  Maximum width (face to 
back) dimensional deviation including the architectural surface shall be 1 inch.  
C. Exposed face shall be finished as specified.  Other surfaces to be smooth form type.  Dime‐size bug 
holes on the block face may be patched to blend into the remainder of the block face.   
D. Concrete for precast blocks shall have a minimum of 28‐day compressive strength of 4,000 psi 
(pounds per square inch). 
E. Reinforcing steel (if used) shall be Grade 60.  Minimum clear cover to reinforcement shall be 1.5 
inches.   
F.  The face pattern shall be selected from the manufacturer’s standard molds.  The color of each block 
unit shall be natural gray (precast concrete).  A concrete stain may be field applied to color the 
block units if specified by the Owner. 
 
2.02  Gravel Base and Drainage Pipe 
A. Leveling Pad shall consist of compacted (1 inch minus) fractured gravel base.  
B. Drainage Backfill material shall be washed stone and shall be placed to a minimum of 1 foot width 
behind the back of the wall and shall extend vertically from the gravel base to an elevation 4 inches 
below the top of the wall. 
C. Backfill material shall be approved by the geotechnical engineer.  Native site excavated soils may be 
compacted in place if approved unless otherwise specified in the drawings.  Unsuitable soils with a 
PL greater than 6, organic soils, and frost susceptible soils shall not be used within a 1 to 1 influence 
area. 
D. Non‐woven geotextile cloth shall be placed between the gravel base and native retained soil. 
E. Where additional fill is needed, Contractor shall submit sample and specification to Engineer for 
approval. 
 
2.03   Drainage 
A. Internal and external drainage shall be a perforated 6 inch drain pipe. 
 
2.04   Geotextile Fabric 
A. Provide a geotextile filter for separation from backfill at the tails of the blocks.  The geotextile shall 
be a needle punched non‐woven fabric with a minimum grab tensile strength of 120 pounds 
(Reference ASTM D4632).  The geotextile may cover the entire back face of the blocks or may be cut 
into strips to cover the gaps between tail units with a minimum of 6 inches of overlap over the 
concrete tail on both sides. 
 
 

Verti‐Crete, LLC ® 2010 ©.  All Rights Reserved      4
 
Engineering Design Manual
• REINFORCED WALLS
                                       
 

Technical Data & Specifications 

PART 3:  CONSTRUCTION OF RETAINING WALL 

3.01    Excavation 
A. Excavate as required to the lines and grades shown on construction drawings for installation of the 
retaining wall.  Excavate to the base level for a sufficient distance behind the face to permit 
installation of the base.   
B. Slope or shore excavation as necessary for safety and for conformance with applicable OSHA 
requirements. 
 
3.02    Foundation and Soil Preparation 
A. On‐site foundation soil shall be examined by the Geotechnical Engineer to ensure that the bearing 
foundation soil strength meets or exceeds assumed design conditions and strength.  Soil not 
meeting the required strength shall be removed and replaced with acceptable, compacted material.  
B. Level the gravel base to lines and grades demonstrated on the construction plans.  Native 
foundation soil shall be compacted to 95 percent of the maximum dry density (ASTM D698, 
Standard Proctor) or 90 percent of modified proctor to ensure a hard and level surface on which 
the first set of blocks may be suitable replacement fill.  
C. Prepare and smooth the granular material to ensure complete contact of the first course with the 
base.  The surface of granular base may be dressed with finer aggregate to aid leveling, provided 
that the thickness of dressing layer should not exceed 3 times the maximum particle size used.  
Native soil compacted in place as each course is set.  
D. Contractor may substitute concrete for granular base material.  Concrete may be placed full 
thickness or as a topping to level the base.  If used as a topping, the concrete shall have a minimum 
thickness of 3 inches. 
 
3.03    Unit Installation 
A. Place the first course of standard wall block units directly on the compacted (1 inch minus) 
fractured gravel base.  Ensure full contact between adjacent blocks so they fit tightly together.  
Check all blocks for uniform alignment and level placement.  
B. Fill and compact the unity core and all voids between and within the blocks with clean (1 inch 
minus) gravel to lock firmly into place.  Continue to check for level and alignment between all 
blocks.  
C. Place clean native soil behind the units in maximum loose lifts of 8 inches and compact.  Compact all 
backfill to a minimum of 95 percent of the maximum dry density (ASTM D698, Standard Proctor).  
For cohesive soils, the moisture content at the time of compaction should be adjusted to within ‐2 
and +3 percent of optimum.  Place backfill in successive lifts until level with the top of the facing 
unit.   
D. Remove and sweep off all excess aggregate and other materials from the top of the blocks before 
continuing on the next block course.   
 
 
 
 
Verti‐Crete, LLC ® 2010 ©.  All Rights Reserved      5
 
Engineering Design Manual
• REINFORCED WALLS
                                       
 

Technical Data & Specifications 

PART 3 (Continued):  CONSTRUCTION OF RETAINING WALL 

 
E. Install geogrid reinforcing fabric of the length and type shown on the construction drawings.  Orient 
the strength axis of the reinforcing fabric perpendicular to the length of the wall.  Extend the 
reinforcing fabric to the face of the block.  Protect fabric from equipment damage. 
F. Install next course of precast concrete retaining wall blocks to bond on top of the base row.  
Position blocks to be offset from seams of blocks on lower course.  Blocks shall be placed at a 
2_3/16 inch setback and recessed over the alignment hoop.  Check each block for proper alignment 
and level.  Pull geogrid reinforcing fabric taut prior to placing backfill materials.  Continue to unit fill 
and backfill behind each course of units.  Place a minimum of 8 inches loose fill material over 
geogrid reinforcing fabric prior to compaction.  Hand‐operated place and compaction equipment 
shall be used around the block and within 3 feet of the wall to achieve consolidation.  
G. Continue to install subsequent courses of blocks in a like manner to elevations shown on the 
construction plans.  Construct wall in level stages, placing the units at each course for the entire 
length of the wall, if possible.  Unit fill and backfill shall be placed to the level of the top of the facing 
block unit before placing the next course.  
H. Final grade above and below the retaining wall shall provide for positive drainage and prevent 
ponding.  Protect completed wall from other construction.  Do not operate large equipment or store 
materials above the wall that exceed the design surcharge loads.  All walls shall be installed in 
accordance with local building codes and requirements.   
 
3.04    Geotextile Filter   
A. See Wall Installation instructions. 
   

Verti‐Crete, LLC ® 2010 ©.  All Rights Reserved      6
 
Engineering Design Manual
• REINFORCED WALLS
                                       
 

Technical Data & Specifications 

PART 4:  QUALITY ASSURANCE 

4.01    Construction Quality Control  
A. The contractor is responsible to ensure that all installation and materials meet the quality specified 
in the construction drawings.  
B. The contractor shall verify that installation is in accordance with the specifications and 
construction drawings.  
 
4.02    Quality Assurance  
A. The owner is responsible to engage testing and inspection service to provide independent quality 
construction assurance.   
B. Compaction testing shall be done a minimum of every 1 foot of vertical fill and every 100 lineal feet 
along the wall.  
C. Testing shall be done at a variety of locations to cover the entire backfill zone.  
D. The independent inspection professional should perform sufficient testing and observation to 
verify that wall installation substantially conforms to the design drawings and specifications.   
   

Verti‐Crete, LLC ® 2010 ©.  All Rights Reserved      7
 
Engineering Design Manual
• REINFORCED WALLS
                                       
 
Silty Soil.   
Internal Angle of Friction = 30° 
No Back Slope.  No Surcharge.  
           
Top of  Embed‐ Geogrid 
Gravel  Reinforcement Course.  Grids are installed on top of the course listed.  Course numbering starts at the 
Wall  ment     Quantity, yd2 per 
Base  base of the wall.  Lengths are in feet, measured from the face of the block. 
Elevation  Depth  ft of wall length 
Course 
above  Below  SF55/
Depth  Course  1  2  3  4  5  6  7  8  9  10  11  12  SF35 
grade  Grade  SF65 
5'  1’  6”  Type  None                                        

Length                                      0  0 
 
7'  1’  6”  Type  None                                        
         Length                                      0  0 

9'  1’  6”  Type  SF35  SF35  SF35  SF35                               


         Length  6  6.5  8  9                          0  3.28 

11'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35                            


         Length  7.5  7.5  8  9  10.5                       0  4.72 

13'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35  SF35                         

         Length  8.5  8.5  8.5  9.5  12  12                    0  6.56 

15'  1'  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35                      

         Length  10  10  10  10  10.5  12  13                 1.11  7.28 

17'  1'  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35                   

         Length  11  11  11  11  11  12  13  14.5              1.22  9.28 

19'  1'  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35                

         Length  12  12  12  12  12  12  13  14.5  15.5           1.33  11.44 

20'‐11"  1'‐1"  6"  Type  SF65  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35             

         Length  13.5  13.5  13.5  13.5  13.5  13.5  13.5  14.5  15.5  17        1.50  14.22 

22'‐10"  1'‐2"  6"  Type  SF65  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35          

         Length  14.5  14.5  14.5  14.5  14.5  14.5  14.5  14.5  15.5  17  18     1.61  16.89 

24'‐9"  1'‐3"  6"  Type  SF65  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35       

         Length  16  16  16  16  16  16  16  16  16  17  18  19.5  3.56  18.50 
All information in the above chart was prepared by Verti‐Block ™ for estimating and preliminary design.  Although the information is conceived to be 
correct, Verti‐Block ™ is not responsible for use of this data in actual project construction.   A registered Professional Engineer must use the actual 
conditions of the proposed project site to design and meet construction requirements.  The end user is solely held liable to apply appropriate use of 
this information.  All Verti‐Block ™ Wall System Specifications are to be followed.  Wall heights greater than 24’ 9” are achievable. 
Additional Notes:         1.      Unit weight soil is assumed to be 120 pcf.  
2. Minimum factors of safety are 1.5 for sliding, 1.5 for overturning, and 2.5 for bearing capacity. 
rd
3. Designs are in general accordance with NCMA’s Design Manual for Segmental Retaining Walls (2  edition). 
4. Global stability has not been addressed in these charts.  
5. The wall design shall address both internal and external drainage and shall be evaluated by the Professional 
Engineer who is responsible for the final wall design. 
6. Geogrid types listed are manufactured by Synteen Technical Fabrics, Inc.  Use of other manufacturers may be 
acceptable and must be evaluated by the Professional Engineer who is responsible for the final wall design. 
7. Backfill material must be compacted as directed by the Project Engineer. 

Verti‐Crete, LLC ® 2010 ©.  All Rights Reserved      8
 
Engineering Design Manual
• REINFORCED WALLS
                                       
 
Well Graded Sand, Sand and Gravel.   
Internal Angle of Friction = 35°   
No Back Slope.  No Surcharge. 
   
Top of  Embed‐ Geogrid 
Gravel  Reinforcement Course.  Grids are installed on top of the course listed.  Course numbering starts at the 
Wall  ment     Quantity, yd2 per 
Base  base of the wall.  Lengths are in feet, measured from the face of the block. 
Elevation  Depth  ft of wall length 
Course 
above  Below  SF55/
Depth  Course  1  2  3  4  5  6  7  8  9  10  11  12  SF35 
grade  Grade  SF65 
5'  1'  6"  Type  None                                        
         Length                                      0  0 

7'  1'  6"  Type  None                                        


   Length                                      0  0 

9'  1'  6"  Type  None                                        


         Length                                      0  0 

11'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35                            


         Length  8  8  8  9  10                       0  4.78 

13'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35  SF35                         

         Length  8.5  8.5  8.5  8.5  10  11                    0  6.11 

15'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35  SF35  SF35                      

         Length  10  10  10  10  10  11  12                 0  8.11 

17'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35                   

         Length  11  11  11  11  11  11  12  13              0  10.11 

19'  1'  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35                

         Length  12  12  12  12  12  12  12  13  14           1.33  11.00 

20'‐11"  1'‐1"  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35             

         Length  13.5  13.5  13.5  13.5  13.5  13.5  13.5  13.5  14.5  15.5        1.50  13.83 

22'‐10"  1'‐2"  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35          

         Length  14.5  14.5  14.5  14.5  14.5  14.5  14.5  14.5  14.5  15.5  16.5     1.61  16.44 

24'‐9"  1'‐3"  6"  Type  SF65  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35       

         Length  16  16  16  16  16  16  16  16  16  16  16.5  17  1.78  19.72 
All information in the above chart was prepared by Verti‐Block ™ for estimating and preliminary design.  Although the information is conceived to be 
correct, Verti‐Block ™ is not responsible for use of this data in actual project construction.   A registered Professional Engineer must use the actual 
conditions of the proposed project site to design and meet construction requirements.  The end user is solely held liable to apply appropriate use of 
this information.  All Verti‐Block ™ Wall System Specifications are to be followed.  Wall heights greater than 24’ 9” are achievable. 
Additional Notes:         1.      Unit weight soil is assumed to be 120 pcf. 
2. Minimum factors of safety are 1.5 for sliding, 1.5 for overturning, and 2.5 for bearing capacity. 
rd
3. Designs are in general accordance with NCMA’s Design Manual for Segmental Retaining Walls (2  edition). 
4. Global stability has not been addressed in these charts.  
5. The wall design shall address both internal and external drainage and shall be evaluated by the Professional 
Engineer who is responsible for the final wall design. 
6. Geogrid types listed are manufactured by Synteen Technical Fabrics, Inc.  Use of other manufacturers may be 
acceptable and must be evaluated by the Professional Engineer who is responsible for the final wall design. 
7. Backfill material must be compacted as directed by the Project Engineer. 

Verti‐Crete, LLC ® 2010 ©.  All Rights Reserved      9
 
Engineering Design Manual
• REINFORCED WALLS
                                       
 
Well Graded Sand, Sand and Gravel.   
Internal Angle of Friction = 35°   
No Back Slope.  250 psf Surcharge.  
   
Top of  Embed‐ Geogrid 
Gravel  Reinforcement Course.  Grids are installed on top of the course listed.  Course numbering starts at the 
Wall  ment     Quantity, yd2 per 
Base  base of the wall.  Lengths are in feet, measured from the face of the block. 
Elevation  Depth  ft of wall length 
Course 
above  Below  SF55/
Depth  Course  1  2  3  4  5  6  7  8  9  10  11  12  SF35 
grade  Grade  SF65 
5'  1’  6”  Type  None                                        

      Length                                      0  0 
 
7'  1’  6”  Type  None                                        

      Length                                      0  0 
 
9'  1’  6”  Type  SF35  SF35  SF35  SF35                         

Length  6  6.5  7.5  8.5                    0  3.17 


 
11'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35                            

      Length  7.5  7.5  8.5  9.5  10                       0  4.78 


 
13'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35  SF35                         

      Length  8.5  8.5  8.5  8.5  10  11                    0  6.11 

15'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35  SF35  SF35                      

      Length  10  10  10  10  10  11  12                 0  8.11 

17'  1'  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35                   

      Length  11  11  11  11  11  11  12  13              1.22  8.89 

19'  1'  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35                

      Length  12  12  12  12  12  12  12  13  14.5           1.33  11.06 

20'‐11"  1'‐1"  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35             

      Length  13.5  13.5  13.5  13.5  13.5  13.5  13.5  13.5  14.5  15.5        1.50  13.83 

22'‐10"  1'‐2"  6"  Type  SF65  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35          

      Length  14.5  14.5  14.5  14.5  14.5  14.5  14.5  14.5  14.5  15.5  16.5     1.61  16.44 

24'‐9"  1'‐3"  6"  Type  SF65  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35       

      Length  16.5  16.5  16.5  16.5  16.5  16.5  16.5  16.5  16.5  16.5  16.5  17.5  1.83  20.28 
All information in the above chart was prepared by Verti‐Block ™ for estimating and preliminary design.  Although the information is conceived to be 
correct, Verti‐Block ™ is not responsible for use of this data in actual project construction.   A registered Professional Engineer must use the actual 
conditions of the proposed project site to design and meet construction requirements.  The end user is solely held liable to apply appropriate use of 
this information.  All Verti‐Block ™ Wall System Specifications are to be followed.  Wall heights greater than 24’ 9” are achievable. 
Additional Notes:         1.      Unit weight soil is assumed to be 120 pcf. 
2. Minimum factors of safety are 1.5 for sliding, 1.5 for overturning, and 2.5 for bearing capacity. 
rd
3. Designs are in general accordance with NCMA’s Design Manual for Segmental Retaining Walls (2  edition). 
4. Global stability has not been addressed in these charts.  
5. The wall design shall address both internal and external drainage and shall be evaluated by the Professional 
Engineer who is responsible for the final wall design. 
6. Geogrid types listed are manufactured by Synteen Technical Fabrics, Inc.  Use of other manufacturers may be 
acceptable and must be evaluated by the Professional Engineer who is responsible for the final wall design. 
7. Backfill material must be compacted as directed by the Project Engineer. 

Verti‐Crete, LLC ® 2010 ©.  All Rights Reserved      10
 
Engineering Design Manual
• REINFORCED WALLS
                                       
 
Well Graded Sand, Sand and Gravel.  
Internal Angle of Friction = 35°   
2:1 Back Slope.  No  Surcharge. 
   
Top of  Embed‐ Geogrid 
Reinforcement Course.  Grids are installed on top of the course listed.  Course numbering starts at the 
Wall  ment 
Gravel     Quantity, yd2 per 
Base  base of the wall.  Lengths are in feet, measured from the face of the block. 
Elevation  Depth  ft of wall length 
Course  SF55/ 
above  Below 
Depth  Course  1  2  3  4  5  6  7  8  9  10  11  12  SF65/  SF35 
grade  Grade 
SF80

5'  1’  6”  Type  None                                        

      Length                                      0  0 
7'  1’  6”  Type  None                                        

      Length                                      0  0 
 
9'  1’  6”  Type  SF35  SF35  SF35  SF35                         

Length  6  7  8.5  10                    0  3.50 


 
11'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35                            

      Length  7.5  7.5  8.5  10  11.5                       0  5.00 


 
13'  1'  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35                         

      Length  8.5  8.5  8.5  10  11.5  13                    0.94  5.72 

15'  1'  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35                      

      Length  10  10  10  10  11.5  13  15                 1.11  7.72 

17'  1'  6"  Type  SF65  SF35  SF35  SF35  SF35  SF35  SF35  SF35                   

      Length  11  11  11  11  11.5  13  14.5  16.5              1.22  9.83 

19'  1'  6"  Type  SF65  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35                

      Length  12  12  12  12  12  13  15  16.5  17.5           1.33  12.22 

20'‐11"  1'‐1"  6"  Type  SF65  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35             

      Length  13.5  13.5  13.5  13.5  13.5  13.5  15  16.5  18  19.5        3.00  13.67 

22'‐10"  1'‐2"  6"  Type  SF80  SF55  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35          

      Length  14.5  14.5  14.5  14.5  14.5  14.5  15  16.5  18  19.5  21     4.83  14.83 

24'‐9"  1'‐3"  6"  Type  SF80  SF55  SF55  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35       

      Length  16.5  16.5  16.5  16.5  16.5  16.5  16.5  16.5  18  19.5  21  22.5  7.33  16.33 
All information in the above chart was prepared by Verti‐Block ™ for estimating and preliminary design.  Although the information is conceived to be 
correct, Verti‐Block ™ is not responsible for use of this data in actual project construction.   A registered Professional Engineer must use the actual 
conditions of the proposed project site to design and meet construction requirements.  The end user is solely held liable to apply appropriate use of 
this information.  All Verti‐Block ™ Wall System Specifications are to be followed.  Wall heights greater than 24’ 9” are achievable. 
Additional Notes:         1.      Unit weight soil is assumed to be 120 pcf. 
2. Minimum factors of safety are 1.5 for sliding, 1.5 for overturning, and 2.5 for bearing capacity. 
rd
3. Designs are in general accordance with NCMA’s Design Manual for Segmental Retaining Walls (2  edition). 
4. Global stability has not been addressed in these charts.  
5. The wall design shall address both internal and external drainage and shall be evaluated by the Professional 
Engineer who is responsible for the final wall design. 
6. Geogrid types listed are manufactured by Synteen Technical Fabrics, Inc.  Use of other manufacturers may be 
acceptable and must be evaluated by the Professional Engineer who is responsible for the final wall design. 
7. Backfill material must be compacted as directed by the Project Engineer. 

Verti‐Crete, LLC ® 2010 ©.  All Rights Reserved      11
 
Engineering Design Manual
• REINFORCED WALLS
                                       
 
Gravel. 
Internal Angle of Friction = 40°   
No Back Slope.  No  Surcharge.  
   
Top of  Embed‐ Geogrid 
Gravel  Reinforcement Course.  Grids are installed on top of the course listed.  Course numbering starts at the 
Wall  ment     Quantity, yd2 per 
Base  base of the wall.  Lengths are in feet, measured from the face of the block. 
Elevation  Depth  ft of wall length 
Course 
above  Below 
Depth  Course  1  2  3  4  5  6  7  8  9  10  11  12  SF55  SF35 
grade  Grade 

5'  1’  6”  Type  None                                        

      Length                                      0  0 
 
7'  1’  6”  Type  None                                        

      Length                                      0  0 
 
9'  1’  6”  Type  None                         

Length                    0  0 
     
11'  1'  6"  Type  None                            

      Length                       0  0 
     
13'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35  SF35                         

      Length  8.5  8.5  8.5  8.5  9  10                    0  5.89 

15'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35  SF35  SF35                      

      Length  10  10  10  10  10  10  11                 0  7.89 

17'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35                   

      Length  11  11  11  11  11  11  11  12              0  9.89 

19'  1'  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35                

      Length  12  12  12  12  12  12  12  12  13           0  12.11 

21"  1'  6"  Type  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35             

      Length  13.5  13.5  13.5  13.5  13.5  13.5  13.5  13.5  13.5  14        0  15.06 

21'‐11"  1'‐1"  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35          

      Length  14.5  14.5  14.5  14.5  14.5  14.5  14.5  14.5  14.5  14.5  15     1.61  16.17 

23'‐9"  1'‐3"  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35       

      Length  16  16  16  16  16  16  16  16  16  16  16  16  1.78  19.56 
All information in the above chart was prepared by Verti‐Block ™ for estimating and preliminary design.  Although the information is conceived to be 
correct, Verti‐Block ™ is not responsible for use of this data in actual project construction.   A registered Professional Engineer must use the actual 
conditions of the proposed project site to design and meet construction requirements.  The end user is solely held liable to apply appropriate use of 
this information.  All Verti‐Block ™ Wall System Specifications are to be followed.  Wall heights greater than 24’ 9” are achievable. 
Additional Notes:         1.      Unit weight soil is assumed to be 120 pcf. 
2. Minimum factors of safety are 1.5 for sliding, 1.5 for overturning, and 2.5 for bearing capacity. 
rd
3. Designs are in general accordance with NCMA’s Design Manual for Segmental Retaining Walls (2  edition). 
4. Global stability has not been addressed in these charts.  
5. The wall design shall address both internal and external drainage and shall be evaluated by the Professional 
Engineer who is responsible for the final wall design. 
6. Geogrid types listed are manufactured by Synteen Technical Fabrics, Inc.  Use of other manufacturers may be 
acceptable and must be evaluated by the Professional Engineer who is responsible for the final wall design. 
7. Backfill material must be compacted as directed by the Project Engineer. 

Verti‐Crete, LLC ® 2010 ©.  All Rights Reserved      12
 
Engineering Design Manual
• REINFORCED WALLS
                                       
 
Gravel. 
Internal Angle of Friction = 40°   
No Back Slope.  250 psf Surcharge.  
   
Top of  Embed‐ Geogrid 
Gravel  Reinforcement Course.  Grids are installed on top of the course listed.  Course numbering starts at the 
Wall  ment     Quantity, yd2 per 
Base  base of the wall.  Lengths are in feet, measured from the face of the block. 
Elevation  Depth  ft of wall length 
Course 
above  Below 
Depth  Course  1  2  3  4  5  6  7  8  9  10  11  12  SF55  SF35 
grade  Grade 

5'  1’  6”  Type  None                                        

      Length                                      0  0 
 
7'  1’  6”  Type  None                                        

      Length                                      0  0 
 
9'  1’  6”  Type  SF35  SF35  SF35  SF35                         

Length  6  6  7  8                    0  3.00 
 
11'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35                            

      Length  7.5  7.5  7.5  8  9                       0  4.39 


 
13'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35  SF35                         

      Length  8.5  8.5  8.5  8.5  9  10                    0  5.89 

15'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35  SF35  SF35                      

      Length  10  10  10  10  10  10  11                 0  7.89 

17'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35                   

      Length  11  11  11  11  11  11  11  12              0  9.89 

19'  1'  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35                

      Length  12  12  12  12  12  12  12  12  13           1.33  10.78 

21"  1'  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35             

      Length  13.5  13.5  13.5  13.5  13.5  13.5  13.5  13.5  13.5  14        1.50  13.56 

21'‐11"  1'‐1"  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35          

      Length  14.5  14.5  14.5  14.5  14.5  14.5  14.5  14.5  14.5  14.5  15     1.61  16.17 

23'‐9"  1'‐3"  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35       

      Length  16  16  16  16  16  16  16  16  16  16  16  16  1.78  19.56 
All information in the above chart was prepared by Verti‐Block ™ for estimating and preliminary design.  Although the information is conceived to be 
correct, Verti‐Block ™ is not responsible for use of this data in actual project construction.   A registered Professional Engineer must use the actual 
conditions of the proposed project site to design and meet construction requirements.  The end user is solely held liable to apply appropriate use of 
this information.  All Verti‐Block ™ Wall System Specifications are to be followed.  Wall heights greater than 24’ 9” are achievable. 
Additional Notes:         1.      Unit weight soil is assumed to be 120 pcf. 
2. Minimum factors of safety are 1.5 for sliding, 1.5 for overturning, and 2.5 for bearing capacity. 
rd
3. Designs are in general accordance with NCMA’s Design Manual for Segmental Retaining Walls (2  edition). 
4. Global stability has not been addressed in these charts.  
5. The wall design shall address both internal and external drainage and shall be evaluated by the Professional 
Engineer who is responsible for the final wall design. 
6. Geogrid types listed are manufactured by Synteen Technical Fabrics, Inc.  Use of other manufacturers may be 
acceptable and must be evaluated by the Professional Engineer who is responsible for the final wall design. 
7. Backfill material must be compacted as directed by the Project Engineer. 

Verti‐Crete, LLC ® 2010 ©.  All Rights Reserved      13
 
Engineering Design Manual
• REINFORCED WALLS
                                       
 
Gravel. 
Internal Angle of Friction = 40°   
2:1 Back Slope.  No  Surcharge.  
   
Top of  Embed‐ Geogrid 
Gravel  Reinforcement Course.  Grids are installed on top of the course listed.  Course numbering starts at the 
Wall  ment     Quantity, yd2 per 
Base  base of the wall.  Lengths are in feet, measured from the face of the block. 
Elevation  Depth  ft of wall length 
Course 
above  Below  SF55/ 
Depth  Course  1  2  3  4  5  6  7  8  9  10  11  12  SF35 
grade  Grade  SF65 
5'  1’  6”  Type  None                                        

      Length                                      0  0 
 
7'  1’  6”  Type  None                                        

      Length                                      0  0 
 
9'  1’  6”  Type  None                         

Length                    0  0 
     
11'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35                            

      Length  8  8  8  9  10                       0  4.78 


 
13'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35  SF35                         

      Length  8.5  8.5  8.5  9  10  11.5                    0  6.22 

15'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35  SF35  SF35                      

      Length  10  10  10  10  10  11.5  12.5                 0  8.22 

17'  1'  6"  Type  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35                   

      Length  11  11  11  11  11  11  11  12              0  9.89 

19'  1'  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35                

      Length  12  12  12  12  12  12  12.5  14  15           1.33  11.28 

21"  1'  6"  Type  SF55  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35             

      Length  13.5  13.5  13.5  13.5  13.5  13.5  13.5  14  15  16.5        1.50  14.06 

21'‐11"  1'‐1"  6"  Type  SF65  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35          

      Length  14.5  14.5  14.5  14.5  14.5  14.5  14.5  14.5  15  16.5  17.5     1.61  16.72 

23'‐9"  1'‐3"  6"  Type  SF65  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35  SF35       

      Length  16  16  16  16  16  16  16  16  16  16.5  17.5  18.5  1.78  20.06 
All information in the above chart was prepared by Verti‐Block ™ for estimating and preliminary design.  Although the information is conceived to be 
correct, Verti‐Block ™ is not responsible for use of this data in actual project construction.   A registered Professional Engineer must use the actual 
conditions of the proposed project site to design and meet construction requirements.  The end user is solely held liable to apply appropriate use of 
this information.  All Verti‐Block ™ Wall System Specifications are to be followed.  Wall heights greater than 24’ 9” are achievable. 
Additional Notes:         1.      Unit weight soil is assumed to be 120 pcf. 
2. Minimum factors of safety are 1.5 for sliding, 1.5 for overturning, and 2.5 for bearing capacity. 
rd
3. Designs are in general accordance with NCMA’s Design Manual for Segmental Retaining Walls (2  edition). 
4. Global stability has not been addressed in these charts.  
5. The wall design shall address both internal and external drainage and shall be evaluated by the Professional 
Engineer who is responsible for the final wall design. 
6. Geogrid types listed are manufactured by Synteen Technical Fabrics, Inc.  Use of other manufacturers may be 
acceptable and must be evaluated by the Professional Engineer who is responsible for the final wall design. 
7. Backfill material must be compacted as directed by the Project Engineer. 
Verti‐Crete, LLC ® 2010 ©.  All Rights Reserved      14
 
Engineering Design Manual
• REINFORCED WALLS
                                       

 
Verti‐Crete, LLC ® 2010 ©.  All Rights Reserved      15
 
Engineering Design Manual
• REINFORCED WALLS
                                       

Verti‐Crete, LLC ® 2010 ©.  All Rights Reserved      16
 
Engineering Design Manual
• REINFORCED WALLS
                                       

Verti‐Crete, LLC ® 2010 ©.  All Rights Reserved      17
 

You might also like