Republic of the Philippines

Department of Education
Region IV-A CALABARZON
Division of Cavite
Trece Martires City National High School
(Cabuco Annex)
Trece Martires City

Achievement Test in Electrical Installation & Maintenance (Grade 10)

Name: ___________________________ Grade & Section: _______________ Date: _______ Score: ________

I. MULTIPLE CHOICE: Direction: Choose the letter of the best answer. Write your answer on a separate sheet of paper.

1. This is generated by examining the goods and services sold within the community.
A. business creation B. business concept C. business pricing D. business idea
2. It is the process of making a new product to be sold to the customers.
A. product analysis B. product development C. product conceptualization D. product
implementation
3. These are luxuries, advantages and desires that every individual considers beyond necessary.
A. wants B. requirements C. desires D. needs
4. This is the factor or consideration presented by a seller that explains why one product or service is different from
or better than that of the competitors.
A. unique selling plan B. unique pricing policy C. unique selling proposition D. finding value-
added
5. A management tool used to assess the environment and to gather important information that can be used for
strategic planning.
A. environmental scanning B. WOTS Analysis C. SWOT Analysis D. survey analysis
6. These are the things that people cannot live without.
A. wants B. requirements C. desires D. needs
7. It is a type of conduit made of metal in a form of coil commonly used for external motor connection.
A. flexible armored conduit B. Flexible Metallic Tubing C. NM conduit D. none of these
8. Which of the following type of NM Sheathed Cable is used in wet locations?
A. NM B. NMS C. NMC D. NMV
9. This is usually bare solid or stranded conductor used for overhead transmission lines and ground wires.
A. Copper/aluminum conductor C. Thermoplastic wires
B. Thermoplastic Covered fixture wire D. Non-metallic sheathed cable
10. These wires are flame retardant, moisture and oil resistant used for building wiring in dry and wet locations.
A. Copper/aluminum conductor C. Thermoplastic wires
B. Thermoplastic Covered fixture wire D. Non-metallic sheathed cable
11. What is the maximum ampacity of 8.0 mm² copper conductor type TW insulation?
A. 15 amperes B. 20 amperes C. 30 amperes D. 40 amperes
12. What is the maximum operating temperature of a THHN wire?
A. 60°C b. 75°C c. 85°C d. 90°C
13. Which of the following refers to a type electrical diagram that shows the detailed physical appearance of a
circuit or wiring installation?
A. schematic diagram B. Pictorial Diagram C. Line diagram D. Actual
connection
14. It is a sketch of the actual connections devices in a circuit or wiring installation.
A. Actual connection diagram B. pictorial diagram C. Line diagram D. schematic
15. A type of flexible armored cable with a rubber insulated conductors inside the armor.
A. type AC B. type ACT C. type ACL D. type ACV
16. An appropriate tool used in cutting flexible armored cable.
A. pliers B. hacksaw C. knife D. scissor
17. What is the equivalent diameter size of number 8 AWG wire in millimeter (mm)?
A. 2.05 mm B. 2.59 mm C. 3.26 mm D. 3.11 mm
18. What is the equivalent of 2.59 mm diameter size in AWG?
A. # 10 AWG B. # 8 AWG C. # 12 AWG D. # 14 AWG
19. What is the length of the free conductors inside the utility or junction box for NM Sheathed Cable?
A. 160 mm B. 145 mm C. 150 mm D. 165 mm
20. Which of the following is the appropriate protection against abrasion for BX cable?
A. fittings B. clamps C. straps D. both A & B
21. These are small drawings or pictograms used to represent various electrical devices in a plan of an electrical
circuit.
A. Electrical drawing B. electrical symbols C. electrical diagram D. none of these
22. It is a smooth, flexible conduit commonly used for wiring installation because of its economic value.
A. Intermediate Metallic Conduit C. Rigid Nonmetallic Conduit
B. Electrical Metallic Tubing D. Flexible Nonmetallic Conduit
23. It is the process of removing sharp edges or burrs left after cutting a conduit?
A. bending B. cutting c. reaming d. preheating
24. Which of the following tool is used to thread Rigid Metallic Conduit?
A. hickey B. heat gun c. reamer d. dies stock
25. Which of the following tools is used in preheating & bending Rigid Nonmetallic Conduit?
A. heat gun B. hickey C. pipe cutter D. reamer
26. What is the standard length of RMC, RNC and EMT?
A. 12 ft B. 10 ft C. 13 ft D. 10 cm
27. Which of the following tools is used in cutting RMC?
A. reamer B. hacksaw C. pipe cutter D. both B & C
28. It refers to an electrical materials used to protect conductors or cable in electrical installation?
A. conduit B. tube wiring C. raceway D. both A & C
29. It is non - metallic unthreaded smooth-walled tubing and commonly used material used is Polyvinyl Chloride?
A. Flexible Metallic Conduit C. Rigid Nonmetallic Conduit
B. Electrical Metallic Conduit D. Flexible Nonmetallic Conduit
30. These are type of conduit that are made of metal and designed to protect electrical wiring from electrical
hazard.
A. Flexible Metallic Conduit C. Rigid Metallic Conduit
B. Electrical Metallic Tubing D. both B & C
31. The standard diameter for RMC and EMT ranges from ________ to _________.
A. ½ to 7 inch C. ½ to 6 inch
B. ½ to 5 inch D. ½ to 8 inch
32. It is an act penalizing the pilferage of electricity and lines/materials, rationalizing system losses by phasing out
pilferage losses as a component thereof, and for other purposes.
A. RA 7830 B. RA 7831 C RA 7832 D. RA 7833
33. It is made of metal or plastic and has the capability to be mounted on a wall or stud.
A. wall plates B. weather-proof boxes C. ceiling boxes D. wall boxes
34. It is used for exterior switches and outlets.
a. weather-proof boxes b. wall plates c. ceiling boxes d. wall boxes
35. It is also known as the faceplates or covers.
a. ceiling boxes b. wall plates c. wall boxes d. weather-proof boxes
36. It is also known as a junction box or splice box.
a. wall boxes b. ceiling boxes c. weather-proof boxes d. wall plates
37. It is a metal box, usually in 2” wide, 3” high and 2 1/2” deep.
a. gem box b. plastic box c. handy box d. drywall box
38. It is a type of wall box, best for new installation and often with a nail built-in for quick attachment to the stud.
a. drywall box b. plastic box c. handy box d. gem box
39. It has expandable arms and can be mounted on a drywall.
a. plastic box b. drywall box c. gem box d. handy box.
40. It is a surface mounted box and has rounded corners for safety.
a. gem box b. handy box c. plastic box d. drywall box
41. It is the easiest method in mounting boxes.
a. by nail b. using a screws c. by soldering d. both a & b
42. The primary function of using electrical boxes in wiring installation is to house the electrical connection and
device.
a. true b. false c. maybe d. not sure
43. It is a technical representation of electrical system proposed to be installed in a building which includes
materials,
devices & equipment.
a. electrical diagram b. Electrical wiring plan c. Electrical symbol d. none of these
44. It refers to a unit of electrical system that is intended to carry or conduct electricity.
a. GFCI b. electricity c. resistance d. device
45. It is an electrical device that detects ground fault and interrupts the flow of electric current.
a. electricity b. GFCI c. Convenience outlet d. ground
46. It is simply an extension cord combined with a GFCI.
a. CB GFCI b. GCFI c. Receptacle GFCI d. Temporary/Portable GFCI
47. A type of GFCI which is used in place of a regular wall outlet or duplex receptacle.
a. CB GFCI b. GCFI c. Receptacle GFCI d. Temporary/Portable GFCI
48. ____ are considered as an extension of a human hand that increases speed, power and accuracy of work.
a. hand tools b. hazard c. risk d. OHS
49 – 54. Choose the letter of the best answer from option given below
A – Measuring tool; B – Power Tools/Equipment; C – Hand tool; D – Pneumatic Tool; E – Hydraulic Tool
49. Pull push rule
50. Hammer
51. Pneumatic Floor jack
52. Electric drill
53. Slide caliper rule
54. hydraulic press
55. It refers to anything that has the potential to cause harm to people, property or the environment.
a. hazard b. risk c. danger d. accidents
56. It improves life, but it can cause serious injury or death and loss of property.
a. internet b. hazard c. electricity d. wire
57. It is the standard size of wire for Lighting Outlet.
a. # 14 AWG b. # 10 AWG c. # 8 AWG d. # 12 AWG
58. It is a multidisciplinary field concerned with safety, health and welfare of people at work.
a. OHS b. SOH c. SOP d. DOP
59. The standard amperage of Circuit breaker used for Lighting Outlet.
a. 20 amps b. 30 amps c. 15 amps d. 10 amps
60. The standard size of Conductor used for Service Entrance.
a. # 14 AWG b. # 10 AWG c. # 8 AWG d. # 12 AWG
TRECE MARTIRES CITY NATIONAL HIGH SCHOOL- CABUCO EXTENSION

TABLE OF SPECIFICATIONS
Exit Assessment
GRADE 10 TLE (EIM)

CPD

No. of Items
No. of Days

Understanding
Remembering

Analyzing
Applying

Creating
Learning Competencies LC CODE

Personal Entrepreneurial TLE_PECS10


Competencies (PECS -Ik-8
TLE_EM10-
IIIk-2
3,5,
18 6 1,4 2
TLE_EM10- 6
IVk-3

Wires and cables TLE_IAEL10E


L-IaIIj-1 9, 8,
7, 17,
18 10 12, 11,
15 19
20 18,

Electrical symbols and diagrams TLE_IAEI10W


DIIIa-IVj-1
13,
20 5 21, 10, 43
14,

Types of conduits, raceway and TLE_IAEI10E


tubing L-IaIIj-2
22, 16,
23,
28, 26,
18 11 24,
30, 27,
25
31 29
Select Tools and Equipment
TLE_IAEI10E 49-
18 7 48
L-IaIIj-2 54

PEC provision in installing electrical TLE_IAEI10W 33- 32,


20 11 42
boxes DIIIa-IVj-2 40 41

Wiring Devices for Floor and


Ground Fault Current Interrupting
46,
Outlets
TLE_IAEI10W 45, 47,
15 7 44,
DIIIa-IVj-2 57 59,
60

Practice occupational safety and TLE_IAEI10W


18 3 58 55 56
health DIIIa-IVj-2

TOTAL 145 60 24 18 15 3

Prepared by:

__________________
Archie P. Cornelio
Teacher I

Checked by:
_____________________
RODRIGO P. MOJICA
OIC, Head Teacher VI