PIPE PROPERTIES
OD: 13.625 in. Grade: VM 110 HCSS
Nominal OD 13.625 in.
Weight: 88.20 lb/ft Drift: 12.250 in. (Special)
Nominal ID 12.375 in.
Wall Th.: 0.625 in.
Nominal Weight 88.20 lb/ft
Nominal Wall Thickness 0.625 in.
®
VAM 21 Nominal Cross Section Area 25.525 sq in.
Grade Type High Collapse Sour Service
Minimum Yield Strength (SMYS) 110 ksi
Maximum Yield Strength 120 ksi
Minimum Ultimate Tensile Strength (UTS) 115 ksi
Drift 12.250 in.

CONNECTION PROPERTIES
Connection Type T&C
Nominal Connection OD 14.699 in.
Nominal Connection ID 12.444 in.

T&C Make-up Loss 6.425 in.


Coupling Length 14.843 in.
Critical Cross Section 25.525 sq in.
Tension Efficiency 100 % Pipe Body
Field Torque Values
Compression Efficiency with Sealability* 100 % Pipe Body
Internal Pressure Efficiency 100 % Pipe Body
Make-up Torque (ft-lb)
External Pressure Efficiency 100 % Pipe Body
45,900 MIN
(*) Tested Compression as per API RP 5C5 / ISO 13679
51,300 OPT
56,700 MAX
CONNECTION PERFORMANCES
Tensile Yield Strength 2,808 klb
Torque with Sealability (ft-lb) Compression Resistance with Sealability* 2,808 klb
85,550 MTS** Internal Yield Pressure 8,830 psi
External Pressure Resistance 6,370 psi

Shouldering Torque (ft-lb) Maximum Structural Bending 37 °/100 ft

2,570 MIN Maximum Bending with Sealability* 20 °/100 ft


35,910 MAX Maximum Load on Coupling Face 1,818 klb
(*) Tested Compression as per API RP 5C5 / ISO 13679

Delta Turn (Turns)*


0.010 MIN
0.130 MAX
(*) Delta Turn: number of turns from shouldering torque
to final torque.
(**) MTS: Maximum Torque with Sealability.

The information available on this Site (‘Information’) is offered in good faith and for general information.It is supposed to be correct at the time of publishing on the Site but is
not intended to constitute professionalor any other type of advice or recommendation and is provided on a ‘as is’ basis.Vallourec does not guarantee the completeness and
accuracy of this Information. Under no circumstances will Vallourec be liable for damage, liability of any kind,or any loss or injury that may result from the credibility given to
this Information or its use. The Information may be amended, corrected, and/or supplemented at any time by Vallourec without warning.Vallourec’s products and services are
subject to Vallourec’s standard terms and conditions or otherwise to the terms resulting from the respective contracts of sale or services. In case of doubt, please raise
the issue to VAM® Services through the Mr. Help channel, or ask your latest VAM® representative.

OVER 140 VAM® SPECIALISTS AVAILABLE WORLDWIDE 24/7 FOR RIG SITE ASSISTANCE

You might also like