1.

Removing of Discharge Valve

The discharge valves of the MP-16 pump should only be removed in order to be replaced or
during maintenance. The following procedure provides guidelines for this process.

Unscrew the upper valve cover from the fluid end module. This should also remove the valve
stem guide, which is affixed to the cover by means of a retaining plate.

Remove the upper valve cover seal from the fluid bore.
Lift the valve spring and discharge valve out of the bore. This may require the use of a hook
magnetic retrieval tool.

The discharge valve seat should only be removed if the valve is to be replaced. To remove, insert
a hydraulic seat puller into the bore and extract, exercising care not to strike the seat directly.
Removing the Suction Valves

The MP-16 suction may be removed for replacement or as part of a routine


maintenance, but also will need to be removed in order to provide access to the liner and
piston assemblies. Use the following procedure for each process, but if only seeking
access to the pistons and liners, only Steps 1-6 below need be completed.

Unscrew the forward valve cover plugs from the fluid end module.
Remove the lower valve cover from the bore.

Remove the lower valve cover seal from the fluid bore.
Carefully remove the valve retainer from the valve bore.

Slide the valve cage out of the fluid bore, exercising care not to hit or damage the valves.