UP STANDARD DETAIL REFERENCE DRAWINGS

DETAIL OF HEAVY WELDING BOSSES FOR THREADED CONNECTIONS AE-036175

N
AWAY AWAY
CONSTRUCTION-NOTES AND DETAILS FOR ISOMETRIC PIPING
INSULATION DETAILS FOR HOT PIPING
AD-036627
AA-036911

SHOP MATERIALS INSULATION DETAILS FOR COLD PIPING AA-036913

INSTALLATION OF JACK SCREWS FOR FLANGED JOINTS AC-036630

TOWARD TOWARD PT N.B.


NOTES
NO DESCRIPTION (INS) STOCK CODE QTY
1. MATERIAL SHOWN WITH A BROKEN LINE AND SPOOLS LISTED IN THE SAUDI ARAMCO
DOWN
PIPE FABRICATION LIST ARE NOT TO BE FURNISHED BY THE VENDOR.

2. PIPING DETAILS SHALL BE CUT AT ALL POINTS MARKED F.W. (FIELD WELD).

1 PIPE , CS API 5L-B-PSL2 , SMLS , BE , 12 PPPCPVSMBESTD5F 8.2 M 3. EACH FABRICATED SECTION SHALL BE CLEARLY MARKED WITH ITS CODE NUMBER.

STD , B36.10M , FBE INT COATED 4. UNLESS OTHERWISE NOTED. (A) ALL DIMENSIONS ARE TO C OR FACE OF FLANGES.

(B) BOLT HOLES ON FLANGES STRADDLE C . (C) WELDING ELBOWS ARE LONG RADIUS.

5. FABRICATION SHALL BE IN ACCORDANCE WITH SAUDI ARAMCO SPECIFICATION 01-SAMSS-10.


FITTINGS 6. GASKET ALLOWANCE

7. PIPING MATERIAL IS
2 TEE , CS A234-WPB , SMLS , BE , STD , 12X12 PTEC34SMBESTDE5 1
B16.9 , FBE INT COATED PIPE SIZE SCHEDULE SPECIFICATION

3 90 LR ELBOW , CS A234-WPB , SMLS , BE , 12 P9LC34SMBESTDE5 1 REFER MTO REFER MTO REFER MTO

STD , B16.9 , FBE INT COATED


4 45 LR ELBOW , CS A234-WPB , SMLS , BE , 12 P4LC34SMBESTDE5 2
STD , B16.9 , FBE INT COATED
8. WELDING STRESS RELIEF - YES NO
X
FLANGES RADIOGRAPHY % 100% X-RAY SPOT X-RAY 01-SAMSS-10 SHOP FIELD

5 WN FLG , CS A105N , CL150 , FF , STD , 12 PFWC1B15FFSTD5V 9 9. TESTING SHOP HYDROSTATIC TEST - YES
THE SHOP HYDROSTATIC TEST SHALL BE CARRIED OUT ON PIECES HAVING ALL ENDS
NO

B16.5 , FBE INT COATED FLANGED.

10. ALL PIPING MATERIAL IS IN ACCORDANCE WITH SAUDI ARAMCO ENGINEERING SPECIFICATION
SAES-L-105 CLASS 1LE0U . ALL EXCEPTIONS ARE NOTED ON THE ISOMETRIC.

REFER BELOW TABLE


FIELD MATERIALS 11. INSULATION SHOWN ON DRAWING
12. REFER TO HYDROSTATIC TEST DIAGRAM FOR TEST LIMIT AND PRESSURE.
13. FOR SMALL BORE LINES (UPTO 1-1/2" ) DIMENSIONS, ROUTING & SUPPORTING SHALL BE FIELD ADJUSTED.
14. ALL DIMENSIONS AND COORDINATES ARE IN MM. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION OF THE SPOOL.

PT N.B. 15. FOR INTERNAL LINED PIPE, LINING SHALL BE DONE AFTER SPOOL FABRICATION & COMPLETION OF ALL HOT WORKS.
16. TIE-IN POINTS CO-ORDINATES TO BE VERIFIED BY CONTRACTOR IN FIELD.

NO DESCRIPTION (INS) STOCK CODE QTY 17. PAINTING / COATING SHALL BE IN ACCORDANCE WITH SAES-H-001/002 AND PROJECT APPROVED COATING MAP.
18. SEAL WELDING REQUIREMENT OF THREADED JOINTS SHALL BE AS PER CL.NO.9 OF SAES-L-110.
19. WELDS SHALL BE RADIOGRAPHED AS PER SAES-W-012 (FOR LINES WITH DESIGN CODE ASME B31.8/B31.4) &
FITTINGS

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
AS PER SAES-W-011 (FOR LINES WITH DESIGN CODE ASME B31.3).
20. CONSTRUCTION OF PLANT PIPING SHALL BE IN ACCORDANCE WITH SAES-L-350.

6 FIG-8 BLANK , CS A516-70 , CL150 , FF , 12 PK8C7G15FF000IX 1 21. ALL INTERFACE CONNECTIONS WITH OTHER PROJECT (WHEREVER APPLICABLE), CO-ORDINATES AND ELEVATIONS
SHALL BE VERIFIED BY CONTRACTOR IN FIELD.
FLG5 GAS7 BLT8 FBE INT COATED PROJ STD DRG , NO
22. INTERNAL FBE LINING CONTRACTOR TO VERIFY AND CONFIRM THE BREAK UP FLANGES PRIOR TO THE SPOOL FABRICATION

FLG5 GAS7 BLT8 23. PLANT COORDINATE SYSTEM HAS BEEN FOLLOWED AS PART OF BI-10-00930.

AD-036633 (FOR SIZES 2" & ABOVE) HIGH POINT OF PLANT DATUM ELEVATION 100.000m WHICH EQUALS 2.05m ABOVE MEAN SEA LEVEL

12"N.B.
FLG5 GAS7 BLT8 0 FOR CONT. SEE SPOOLS TO BE FABRICATED BY VENDOR
57 SHT 002 GASKETS
NO.
PIECES
MARK NO. SIZE
WEIGHT
LBS
NO.
PIECES
MARK NO. SIZE
WEIGHT
LBS
1875 85 356 E 30363930
3 8
7 GASKET , SYNTHETIC W/ CENTERING RING , 12 PGGNSC20115BL02 6
S10 N 30307363
FLG5 GAS7 BLT8 38 FULL FACE , 1/16" (1.6 MM) THK ,
191 GL01-12 44 19 EL +101298 CL150 , B16.5 , B16.21
7 254 9
4 36
6 STEM UP BOLTS
EL +102347 1 5
12"N.B. 303 8 STUD BOLT (CONT) , CR-MO A193-B7 , W/ 2 7/8 PB1BLCSACS16002 60
FLG5 37 1 REST REST SF HVY HEX NUTS , A194-2H , B1.1 ,
31
303 50 CERAMIC-FLUOROPOLYMER COATED , DIA
18 FLG5
11 GAS7 (IMP) X LEN (MET) - 115 mm Length
79 FLG5 SPOOLS TO BE FABRICATED BY SAUDI ARAMCO
2 6
7 NO.
MARK NO. SIZE
NO.
MARK NO. SIZE

12X12"N.B. TAIL U VALVES / IN-LINE ITEMS PIECES PIECES

9 1 FOR CONT. SEE


1 9 GATE VALVE , CS A216-WCB , CL150 , FF , 12 PVGC2S15FF8ABWV 1
RB-901086 B16.5 , B16.10 DIMS , API 600, OS&Y ,
8
FLG5 OW-5064
1049

BB , B61/B62 BRONZE TRIM (LESS THAN


4 E 30358921
FOR CONT. SEE 16% ZINC) , INT FBE LND BODY , HW
SHT 004 N 30308344
E 30353871 EL +101298 PIPE SUPPORTS
49 N 30308598
10 10 GUIDE FOR BARE PIPE 12 GL01-12 1
EL +102347
PIECE MARKS
REFERENCE DRAWINGS
5 6 7 8 9
DRAWING CONTROL SHEET FOR J.O. 10-00930-0002 RD-086148
FLG5 GAS7 BLT8 PIPING PLAN RA-685466.001
P&ID NA-518622.003
LINE DESIGNATION TABLE RD-912750
HYDROSTATIC TEST DIAGRAM RA-901145-001
PROJECT PIPING MATERIAL SPECIFICATION RE-685500
PIPE SUPPORT STANDARD RE-901041

REVISION VALIDATION

THIS REVISION NO. 00 IS COVERED, FOR ALL APPROVAL AND CERTIFICATION


REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:

10-00930-0002-001

Worley DESIGN CERTIFICATION

ENGG./DATE
(DESIGN AGENCY)
CERTIFIED BY/DATE
REVIEW FOR KEY DRAWINGS
REQUIRED
CONST. AGENCY/DATE
(SAUDI ARAMCO)
OPERATIONS/DATE BY/DATE
OTHER

RAM WAB MKH AMM


04/07/23 04/07/23 04/07/23 04/07/23

07 May 2023 REV.NO. DATE REVISION DESCRIPTION

00 04/07/23 ISSUED FOR CONSTRUCTION

JOB ORDER/EWO NO.


THIS REVISION IS NOT TO BE USED FOR
10-00930-0002
ISSUED FOR CONSTRUCTION
CONSTRUCTION UNTIL CERTIFIED AND DATED

SAUDI ARABIAN OIL COMPANY


DRAWING TYPE
ISO 12"-OW-5062-1LE0U ISO
TANK DEWATERING PUMPS G-0117A/B
CHEMICAL DESIGN OPERATING TEST PRESS. TEST RADIOGRAPHY % INSULATION TRACING PAINTING STRESS LINE ID
CLEANING TEMP. PRESS. TEMP. PRESS. (PSIG) MEDIUM SHOP FIELD THK. TYPE SYS NO. TERMINAL NORTH
(DEG. F) (PSIG) (DEG. F) (MM) SAUDI ARABIA
(PSIG) RAS TANURA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

NO 150 55 120 0.07-13.7 NOTE-12 WATER NOTE-19 NOTE-19 0 mm NO NOTE-17 SYS-02 OW-5062
060 L RB-901084 003 00
Saudi Aramco 2825 ENG. (05/05)

RESTRICTED
SA-TR-799 SMART CADD-03