Professional Documents
Culture Documents
Ruijie All Optical I-Share+ Solution Catalog
Ruijie All Optical I-Share+ Solution Catalog
Solution Catalog
All Optical i-Share+ Solution Makes Everything Possible
Key Products of the All Optical i-Share+
Solution
RG-PF2920-DPBOX-P
RG-MAP852-SF-S
One 1G fiber port for uplink and one 1G copper port for downlink
Maximum wireless transmission rate of 1.775Gbps
I-Share and panel modes supported
Preferred choice for dormitories using wired networks and light apps
Remote power supply by crimping wires to a power connector
RG-MAP852-SF-M
One 1G/2.5G fiber port for uplink and four 1G copper ports for downlink
Maximum wireless transmission rate of 2.976 Gbps
I-Share and panel modes supported
Remote power supply by crimping wires to a power connector
RG-MAP852-SF-U
One 1G/2.5G fiber port for uplink and eight 1G copper ports for down-
link
Maximum wireless transmission rate of 2.976Gbps
I-Share and panel modes supported
Both wired and wireless networks available, with both appearance
and performance taken into account
Remote power supply by crimping wires to a power connector
RG-AP820-I
RG-AP880-AR
RG-AP680-AR
Phosphate-steel wire
G657A2
Hybrid cable: Dual-core fiber-optic cable,2×0.4 mm copper wire, indoor
2
Category 6e cable
0.4 mm 2
200 m 120 m N/A
1.0 mm 2
500 m 280 m 150 m
1.5mm 2
840 m 420 m 220 m
Note: There is loss in the PoE power supply. The PoE output power is 15.4W and the endpoint power is 12.95W. The PoE+
output power is 30W and the endpoint power is 25.4W. The PoE++ output power is 90W andthe endpoint power is 71W.
DC plug
Fiber-optic cable
Wires are connected to a pRRU power connector to function as an RJ45 PoE power plug. Reinforcing steel wire
Hybrid cable
Application device side
component
Wire crimping
Hybrid cable
Hyb
rid b
ox
Reused AP
Master AP side
Wire crimping
Full-scenario wireless coverage by Mute and high reliability design for the
optical APs Optical i-Share master AP
The maximum output power of the system is
Classrooms, dormitories, offices, conference
480W, and the failure rate is lower. The maxi-
rooms, auditoriums, and outdoor scenarios
mum work noise is not more than 50dB, which
can be all covered by fiber-optic cables.
does not affect people's work and rest.
Hybrid cables comply with IEEE 802.3af/at/bt Hybrid cables are thinner than common
and are compatible with third-party powered cables implementing the same functions as
devices. hybrid cables. More options are available for
full-scenario wireless coverage.
CAT5E/6A Network
Optical Hybrid Cable Optical Hybrid Cable
Key Specs Cable [traditional POE
[POF transmission] Transmission Safety Instructions
transmission]
AF:36-54V
Same as left, follow POE Low voltage DC transmission, safe and
Remote Voltage AT:42.5-57V
standard reliable
BT:41.2-57V
GB/T 3048.4 Test methods for electrical properties of wires and cables - Part 4: Conductor DC resistance test
GB/T 3048.5 Test methods for electrical properties of wires and cables - Part 5: Insulation resistance test
GB/T 3048.8 Test methods for electrical properties of wires and cables - Part 8: AC voltage test
Copper Cable
GB/T 3048.9 Test methods for electrical properties of wires and cables - Part 9: Spark test of insulated wire cores
GB/T 3048.10 Test methods for electrical properties of wires and cables - Part 10: Spark test for extruded
sheath
IEC 60794-1-2:2003, MOD Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test
procedures
GB/T 9771.7 Single-mode optical fibers for communications - Part 7: Characteristics of bending-loss-
insensitive single-mode optical fibers for access networks
IEC 60793-1-20:2001, MOD Optical fibres - Part 1-20: Measurement methods and test procedures - Fibre
geometry
IEC 60793-1-21:2001, MOD Optical fibres - Part 1-21: Measurement methods and test procedures - Coating
geometry
Optic Cable
IEC 60793-1-40:2001, MOD Optical fibres - Part 1-40: Measurement methods and test procedures -
Attenuation
IEC 60793-1-44:2001, MOD Optical fibres - Part 1-44: Measurement methods and test procedures - Cut-off
wavelength
IEC 60793-1-45:2001, MOD Optical fibres - Part 1-45: Measurement methods and test procedures - Mode
field diameter
IEC 60793-1-47:2001, MOD Optical fibres - Part 1-47: Measurement methods and test procedures -
Macrobending loss
IEC60227-1: 2007, IDT Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -
Part 1: General requirements
IEC 60227-3:1997, IDT Amendment 1 - Polyvinyl chloride insulated cables of rated voltages up to and
including 450/750 V - Part 3: Non-sheathed cables for fixed wiring
IEC 60811-1-1:2001, IDT Common test methods for insulating and sheathing materials of electric cables and
optical cables – Part 1-1: Methods for general application – Measurement of thickness and overall
dimensions – Tests for determining the mechanical properties
IEC 60811-1-2:1985, IDT Common test methods for insulating and sheathing materials of electric cables and
optical cables – Part 1-2: Methods for general application – Thermal ageing methods
IEC 60811-1-3:2001, IDT Common test methods for insulating and sheathing materials of electric and optical
Inner Sheath/Outer cables-Part 1-3: Methods for general application-Measurement for determining the density -Water
absorption tests-Shrinkage test
Sheath
IEC 60811-1-4:1985, IDT Common test methods for insulating and sheathing materials of electric and optical
cables-Part 1-4: Methods for general application-Test as low temperature
IEC 60811-2-1:2001, IDT Common test methods for insulating and sheathing materials of electric and optical
cables-Part 2- 1: Methods specific to elastomeric compounds-Ozone resistance,hot set and mineral oil
immersion tests
IEC 60811-3-1:1985, IDT Common test methods for insulating and sheathing materials of electric cables - Part
3: Methods specific to PVC compounds - Section One: Pressure test at high temperature - Tests for
resistance to cracking
IEC 60811-3-2:1985, IDT Common test methods for insulating and sheathing materials of electric cables -
Part 3: Methods specific to PVC compounds - Section Two: Loss of mass test - Thermal stability test
GB/T 24202 Carbon steel wire for fiber optic cable reinforcement
YD/T1113 Halogen-free and low-smoke flame retardant materials for communication cables and optical cables
YD/T1173-2016 Flame-retardant and fire-resistant flexible cable for communication power supply
IEC 60754-2 1991 Test on gases evolves during combustion of electric cables-Part 2: Determination of degree
of acidity of gases evolved during the combustion of materials taken from electric cables by measuring PH and
conductivity
Strength and Flame
IEC 61034:1997 Measurement of smoke density of cables burning under defined conditions
Retardancy
IEC 60332-1-2:2004, IDT Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for
vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
IEC 60332-3-23: 2000, IDT Tests on electric cables under fire conditions - Part 3-23: Test for vertical flame
spread of vertically-mounted bunched wires or cables
IEC 60332-3-24: 2000, IDT Tests on electric cables under fire conditions - Part 3-24: Test for vertical flame
spread of vertically-mounted bunched wires or cables