Professional Documents
Culture Documents
Vrf-Catalogue 2017 GB
Vrf-Catalogue 2017 GB
Vrf-Catalogue 2017 GB
Air conditioning
VRF systems
Systemair Trust
We consider your trust in us as a supplier an important goal. It is always included in our work
on all levels and in all areas whether it is a question of cooperation, quality, deliveries or
documentation. This catalogue is of course a part of this work.
With this catalogue, which features products of air conditioning, we want to give you as a
customer a general overview of what Systemair can offer within this field. More detailed
information is available in our Online catalogue at www.systemair.com and as downloadable
software. Systemair’s range of fans, air distribution products and accessories also appears in our
printed main catalogue.
Our product development leads the field - latest technologies in unitdesign, fans, motors,
heat recovery, chillers, fan coils,... interact to give high efficiency and with that low power
consumption. Systemair has grown each year since the start and we aim to continue with this
trend.
Systemair strives to be a reliable supplier of quality products. We help our customers to focus on
their own business. Reliable deliveres give the customers greater possibilities to quickly complete
a job, and move on to the next project.
© Systemair 2017.
Systemair reserves the right to make technical changes. For updated documentation, please refer to www.systemair.com
Content | 3
Content
Systemair 4
Product Range 6
Application 8
VRF systems 10
Skinnskatteberg, Sweden
Eidsvoll, Norway
Hässleholm, Sweden
Aarhus, Denmark Ukmergé, Lithuania
Windischbuch, Helmstadt, Langenfeld, Waalwijk, The Netherlands
Mühlheim a.d.R., Winterbach, Germany Pardubice, Czech
Bouctouche, Canada Bratislava, Slovakia
Tillières, France
Tillsonburg, Canada Maribor, Slovenia
Milan, Italy
Istanbul, Turkey
Kansas City, USA Madrid, Spain
Wujiang, China
New Delhi, India
Hyderabad, India
Product range
Fire and smoke dampers Smoke extract fans Fire & smoke dampers
High efficient fans to extract the Dampers that reduce the spread of
combustion smoke. smoke and fire.
Air distribution products Supply, extract & transfer devices Nozzle diffusers
The range also includes a wide For mounting in ceilings or walls. Optimum flexibility and comfort in air
selection of air distribution products distribution for rooms.
and accessories.
Air Conditioning
The strengh point of Systemair
Air Conditioning products is a wide
range with several options and
accessories: chiller, water terminal,
close control, roof top, water source
heat pump etc.
Applications
Schools
In buildings for school, the load to be disposed is variable during the day due to the
presence of people only for some periods, thus it is mandatory to control the users
requirements during daily plant use. Systemair offers a wide range of equipment
suitable for this purpose, the fan coils with EC motors allow to obtain the required
flexibility.
Offices
In buildings for tertiary application, the air conditioning and the ventilation are
necessary during the day.
The heat loads to be removed are generally generated by people present, from the
lighting system, from solar radiation and by machines.
Normally it is necessary the use of chillers, Heat Pump to produce cold and/or hot
water to be sent to hydronic (fan coils, cassettes, ducted) to obtain an optimum air
conditioning of offices.
Commercial buildings
Normally the number of people varies continuously; the optimal solution would
be to use machinery for the conditioning with variable flow and with constant
monitoring of concentration of pollutants (VOC and CO2). Systemair products can
easily meet the plantʼs requirement .
Industry
Industrial plants generate a large amount of heat that must be dissipated in the
appropriate way. Systemair offers a wide range of products (chillers from 20 kW
to 1.680 kW) that can be readily integrated industrial installation. The chiller can be
used both for air conditioning and for the cooling equipment process (production of
chilled water up to -10°C).
Hotels
In the hotel rooms, it is needed a high level of comfort with the minimum impact with
respect to the noise level. Systemair ducted products equipped with EC motors fully
comply with requirements efficiency, cooling capacity and sound impact , required by
this type of installations.
10 | VRF systems
SYSVRF
VRF systems | 11
SYSVRF of Systemair are available with different configurations: the typical heat pump Mini and Modular 2-pipe outdoor
units Air-cooled or Water-cooled and the superior Modular heat recovery 3-pipe units.
SYSVRF CEILING 40
12 | VRF systems
Low noise
Low noise of both outdoor and indoor units makes the job
a multizone system virtually inconspicuous.
VRF systems | 13
SYSVRF lineup
In 2014 Systemair launched a new generation of VRF multi-zone systems - the SYSVRF series. The basis principle of work
lies on the advantages of the DC Inverter technology and scroll compressors and the achieved results far exceed the high
standards set by the industry.
Through the use of modern technologies and implementation of their own development has significantly improved energy
efficiency and decreased the noise level, with compact dimensions, increased ease of installation and maintenance,
greatly expanded the range of application from light commercial to large commercial spaces.
SYSVRF mini SYSVRF AIR EVO HR SYSVRF AIR EVO HP SYSVRF WATER EVO HP
2 Pipe Heat Pump Modular 3 Pipe Heat Recovery Modular 2 Pipe Heat Pump Modular 2 Pipe Heat Pump
8,0-22,4 kW 25,0-180,0 kW 25,0 - 246,0 kW 25,0 - 100,0 kW
Dimensions
SYSVRF 120 to 180 and 224 SYSVRF 080
H
1075
A
Model 080 120 to 180 224
A 990 900 1.120
B
B 624 600 874
C 354 348 440
D 336 320 400
E 396 400 528
E
D
F
C
Technical features
080 AIR EVO 120 AIR EVO 140 AIR EVO 160 AIR EVO 180 AIR EVO 224 AIR EVO
Model Outdoor unit SYSVRF
HP Q HP Q HP R HP R HP R HP R
Art. no. 314392 314089 314092 314094 314777 314778
Power supply V/Ph/Hz 220-240/1/50 380-415/3+N/50
Cooling capacity Nom / Eurovent kW 8,0 / 7,2 12,3 / 12,3 14,0 / 14,0 15,5 / 15,5 17,5 / 17,5 22,4 / -
Power input Nom / Eurovent kW 2,05 / 1,85 3,25 / 3,25 3,95 / 3,95 4,52 / 4,52 5,30 / 5,30 6,80 / -
EER Nom / Eurovent kW/ kW 3,9 / 3,9 3,78 / 3,78 3,54 / 3,54 3,43 / 3,43 3,30 / 3,30 3,29 / -
SEER/SCOP 5,1 / 3,8 7,1 / 4,11 6,68 / 3,96 6,42 / 3,83 6,21 / 3,92 6,21 / -
Heating capacity Nom / Eurovent kW 9,0 / 7,2 13,2 / 13,2 15,4 / 15,4 17,0 / 17,0 19,0 / 19,0 24,5 / -
Power input Nom / Eurovent kW 2,24 / 1,79 3,47 / 3,47 4,16 / 4,16 4,77 / 4,78 5,0 / 5,0 5,90 / -
COP Nom / Eurovent kW/ kW 4,02 / 4,02 3,80 / 3,80 3,70 / 3,70 3,56 / 3,56 3,80 / 3,80 4,15 / -
Max. current A 18,5 24,4 11,0 12,0 12,5 17,2
Quantity pcs 1 DC Inverter/ Rotary
Compressor Start-up method Soft start
Refrigerant oil ml 670+200 870+630 870+630 1.400+250 1.400+250 1.700+1.500
Type/motor 1 Axial / 1 DC motor 2 Axial / DC motor
Fan
Air flow m3/h 5.500 6.000 6.800 10.500
Sound power level dB(A) 67 70 71 72 74 74
Sound pressure level dB(A) 56 57 57 57 59 59
Type R410A
Refrigerant
Factory charge kg 2,95 3,3 3,9 3,9 4,5 6,2
Dimension (LxWxH) mm 1.075x396x966 900x400x1.327 1.120x528x1.558
Packing (LxWxH) mm 1.120x435x1100 1.030x435x1.456 1.270x565x1.720
Net/gross weight kg 62/67 95/106 95/106 100/111 107/118 147/163
Liquid pipe mm (in) 9,5 (3/8") 9,5 (3/8")
Piping dimension
Gas pipe mm (in) 15,9 (5/8") 19,1 (3/4")
Max quantity indoor units connection pcs 4 6 6 7 9 11
Operating ambient temperature range °C Cooling -15 … +46 / Heating -15 … +27
Eurovent data are defined for combination ratio equals to 100% and for Duct indoor units.
Operating conditions
Piping Lenght
Dimensions
SYSVRF 252/280/335 AIR EVO HP R SYSVRF 400/450/500/560/615 AIR EVO HP R
1250
1615
1635
990
765
790
VRF Heat Pump | 17
Technical features
252 AIR 280 AIR 335 AIR 400 AIR 450 AIR EVO 500 AIR EVO 560 AIR EVO 615 AIR EVO
Model Outdoor unit SYSVRF
EVO HP R EVO HP R EVO HP R EVO HP R HP R HP R HP R HP R
Art. no. 314744 314745 314746 314747 314749 314750 314775 314776
Power supply V/Ph/Hz 380-415/3+N/50 or 60
Cooling capacity Nom/Eurovent kW 25,2 / 25,2 28 / 28 33,5 / 33,5 40 / 40 45 / 45 50 / 50 56 / 56 61,5 / 61,5
Power input Nom/Eurovent kW 5,36 / 6,25 6,22 / 7,49 7,79 / 8,91 9,3 / 11,7 10,98 / 13,6 12,82 / 14,7 14,51 / 16,5 16,44 / 19,8
EER Nom/Eurovent kW/ kW 4,7 / 4,03 4,5 / 3,74 4,3 / 3,76 4,3 / 3,43 4,1 / 3,30 3,9 / 3,40 3,86 / 3,40 3,74 / 3,10
SEER/SCOP 8,25 / 6,52 7,90 / 6,35 7,54 / 6,13 7,54 / 6,03 7,20 / 5,82 7,36 / 5,67 7,28 / 5,50 7,04 / 5,25
Heating capacity Nom/Eurovent kW 27 / 27 31,5 / 31,5 37,5 / 37,5 45 / 40 50 / 45 56 / 50 63 / 56 69 / 61,5
Power input Nom/Eurovent kW 4,82 / 5,30 5,94 / 6,89 7,65 / 8,91 9,38 / 9,83 10,87 / 11,69 13,18 / 12,5 15,29 / 14,0 17,12 / 16,2
COP Nom/Eurovent kW/ kW 5,6 / 5,09 5,3 / 4,57 4,9 / 4,21 4,8 / 4,07 4,6 / 3,85 4,25 / 4,00 4,12 / 4,00 4,03 / 3,80
Max. current A 25,6 25,6 27,5 35,2 35,2 42,4 53,4 53,4
Quantity pcs 1 DC Inverter/ Scroll 2 DC Inverter/ Scroll
Compressor Start-up method Soft start
Refrigerant oil ml 500 2x500
Type/motor 1 Axial / DC motor 2 Axial / DC motor
Fan Static pressure Pa 0-20 (20-60 factory option) 0-20 (20-60 factory option)
Air flow m3/h 12.000 12.000 12.000 14.000 14.000 16.000 16.000 16.000
Sound power level dB(A) 79 83 82 88 88 88 88 88
Sound pressure level dB(A) 59 63 62 66 66 66 66 66
Type/ motor R410A
Refrigerant
Factory charge kg 9 9 11 13 13 13 16 16
Dimension (LxWxH) mm 990x790x1635 1340x790x1635
Packing (LxWxH) mm 1055x855x1805 1405x855x1805
Net/gross weight kg 219/234 219/234 237/252 297/315 297/315 305/323 340/358 340/358
Liquid pipe mm (in) 12,7 (1/2") 15,9 (5/8")
Piping dimension
Gas pipe mm (in) 25,4 (1") 31,8 (1 1/4")
Max quantity indoor units connection pcs 13 16 20 23 26 29 33 36
Operating ambient temperature range °C Cooling -15 … +48 / Heating -20 … +24
Eurovent data are defined for combination ratio equals to 100% and for Duct indoor units.
Operating conditions
Piping Lenght
Maximum piping (the farthest IDU from the first indoor unit
branch) equivalent lenght.
* When the farthest pipe length is more than 40m, it needs to meet specific conditions according to the installation part of the technical manual.
18 | VRF Heat Pump combination
SYSVRF JOINT
67/75 SYSVRF 670 AIR EVO HP R SYSVRF 335 AIR EVO HP R x2 39
OUT 02 HP
SYSVRF JOINT
100/112 SYSVRF 1000 AIR EVO HP R SYSVRF 500 AIR EVO HP R x2 59
OUT 02 HP
SYSVRF JOINT
123/138 SYSVRF 1230 AIR EVO HP R SYSVRF 615 AIR EVO HP R x2 64
OUT 02 HP
VRF Heat Pump combination | 19
Cooling/ Max.
Recommended Outdoor
Design Heating Model indoor
combination branch
capacity kW unit qty
SYSVRF JOINT
184,5/207 SYSVRF 1845 AIR EVO HP R SYSVRF 615 AIR EVO HP R x3 64
OUT 03 HP
SYSVRF JOINT
246/276 SYSVRF 2460 AIR EVO HP R SYSVRF 615 AIR EVO HP R x 4 64
OUT 04 HP
20 | VRF Heat Recovery
Dimensions
SYSVRF 252/280/335/400/450 AIR EVO HR R
1615
1250
1615
765
765
VRF Heat Recovery | 21
Technical features
252 AIR EVO 280 AIR EVO 335 AIR EVO 400 AIR EVO 450 AIR EVO
Model Outdoor unit SYSVRF
HR R HR R HR R HR R HR R
Art. no. 314084 314085 314086 314087 314088
Power Supply V/Ph/Hz 380-415/3+N/50 or 60
Cooling capacity Nom/Eurovent kW 25,2 /25,2 28,0 / 28,0 33,5 / 33,5 40,0 / 40,0 45,0 / 45,0
Power Input Nom/Eurovent kW 5,73 / 5,97 6,67 / 6,75 8,07 / 9,28 11,30 / 11,5 13,24 / 14,2
EER Nom/Eurovent kW/ kW 4,40 / 4,42 4,20 / 4,15 4,15 / 3,61 3,54 / 3,48 3,40 / 3,17
SEER/SCOP 7,53 / 6,23 7,43 / 6,05 7,40 / 6,02 6,68 / 5,67 6,38 / 5,45
Heating capacity Nom/Eurovent kW 27,0 / 27,0 31,5 / 31,5 37,5 / 37,5 45 / 40 50 / 45
Power Input Nom/Eurovent kW 6,0 / 5,02 7,33 / 6,21 8,72 / 9,24 11,19 / 9,76 12,79 / 11,9
COP Nom/Eurovent kW/ kW 4,50 / 5,38 4,30 / 5,07 4,30 / 4,06 4,02 / 4,10 3,91 / 3,78
Max. current A 20,8 22,1 22,8 31,8 32,8
Quantity pcs 1 DC Inverter / Scroll 2 DC Inverter / Scroll
Compressor Start-up method Soft start
Refrigerant oil ml 500 2X500
Type/motor 2 Axial / DC motor
Fan Static pressure Pa 0-20 (0-40 factory option)
Air flow m3/h 12.000 12.000 13.000 15.000 15.000
Sound power level dB(A) 79 83 84 88 88
Sound pressure level dB(A) 57 57 58 60 60
Type/motor R410A
Refrigerant
Factory charge kg 10 10 10 13 13
Dimension (LxWxH) mm 1.250x765x1.615 1.250x765x1.615
Packing (LxWxH) mm 1.305x825x1.790 1.350x825x1.790
Net/gross weight kg 255/273 303/322
Liquid pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Low pressure gas pipe mm (in) 22,2 (7/8”) 25,4 (1”) 28,6 (1 1/8”)
Piping dimension High pressure gas pipe mm (in) 19,1 (3/4”) 22,2 (7/8”)
Oil balance pipe mm (in) 6,35 (1/4”)
Gas balance pipe mm (in) 19,1 (3/4")
Max quantity indoor units connection pcs 13 16 20 23 26
Operating ambient temp. range °C Cooling -5...+48 / Heating -20...+24 / Simultaneous Cooling and Heating -5...+24
Eurovent data are defined for combination ratio equals to 100% and for Duct indoor units.
Operating conditions
Indoor unit Outdoor unit Piping lenght Level difference
Cooling mode 27°C DB, 19°C WB 35°C DB,24°C WB 7,5 m 0m
Heating mode 20°C DB, 15°C WB 7°C 7,5 m 0m
Piping Lenght
Maximum piping (the farthest IDU from the first indoor unit
branch) equivalent lenght.
* When the farthest pipe length is more than 40m, it needs to meet specific conditions according to the installation part of the technical manual.
22 | VRF Heat Recovery switch module
Technical features
SYSVRF BOX SYSVRF BOX SYSVRF BOX
Model
02 HR 04 HR 06 HR
Art. no. 314161 314162 314186
Power Supply V/Ph/Hz 220-240/1/50 or 60
Max indoor unit groups 2 4 6
Max number of each group indoor units 4 4 4
Max number of all downstream indoor units 4x2=8 4x4=16 4x6=24
Max capacity of each group indoor units kW 16 16 16
Total capacity of all downstream indoor units kW <28 <45 <45
Liquid pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) 15,9 (5/8”)
Connect to outdoor unit High pressureg gas pipe mm (in) 19,1 (3/4”) 22,2 (7/8”) 22,2 (7/8”)
Piping connections Low pressure gas pipe mm (in) 25,4 (1”) 31,8 (1 1/4”) 31,8 (1 1/4”)
Liquid pipe mm (in) 9,5 (3/8”) 9,5 (3/8”) 9,5 (3/8”)
Connect to indoor unit
Gas pipe mm (in) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”)
Dimension (LxWxH) mm 630x225x600 960x225x600 960x225x600
Packing (LxWxH) mm 725x325x685 1.055x325x685 1.055x325x685
Net/gross weight kg 19,5/27 31/40 35/44,5
SYSVRF JOINT
56/63 SYSVRF 560 AIR EVO HR R SYSVRF 280 AIR EVO HR R x2 33
OUT 02 HR
SYSVRF JOINT
80/90 SYSVRF 800 AIR EVO HR R SYSVRF 400 AIR EVO HR R x2 46
OUT 02 HR
SYSVRF JOINT
90/100 SYSVRF 900 AIR EVO HR R SYSVRF 450 AIR EVO HR R x2 53
OUT 02 HR
VRF Heat Recovery combination | 25
Cooling/ Max.
Recommended Outdoor
Design Heating Model indoor
combination branch
capacity kW unit qty
SYSVRF JOINT
120/135 SYSVRF 1200 AIR EVO HR R SYSVRF 400 AIR EVO HR R x3 64
OUT 03 HR
SYSVRF JOINT
135/150 SYSVRF 1350 AIR EVO HR R SYSVRF 450 AIR EVO HR R x3 64
OUT 03 HR
SYSVRF JOINT
180/200 SYSVRF 1800 AIR EVO HR R SYSVRF 450 AIR EVO HR R x4 64
OUT 04 HR
26 | VRF Heat Pump water-cooled
Dimensions
780
550
1000
52
176.5
55
152
45
32
198
95
112 70 64
61.5
50
620
20
52 444 52 326.5
30
VRF Heat Pump water-cooled | 27
Technical features
Model Outdoor unit SYSVRF 252 WATER EVO HP R 280 WATER EVO HP R 335 WATER EVO HP R
Art. no. 314247 314248 314249
Power Supply V/Ph/Hz 380-415/3+N/50
Cooling capacity kW 25,2 28,0 33,5
Power Input kW 4,80 6,10 8,00
EER 5,25 4,59 4,19
Heating capacity kW 27,0 31,5 37,5
Power Input kW 4,45 5,83 7,80
COP 6,07 5,40 4,81
Quantity pcs 1
Compressor
Crankcase heater W 40-80 40-80 40-80
Inverter Scroll
Refrigerant oil ml 500 500 500
Water flow m3/h 5,4 6,0 7,2
Pressure drop kPa 35 40 48
Sound pressure level dB(A) 51 52 52
Type R410A
Refrigerant
Refrigerant charge kg 2,0 2,0 2,0
Dimension LxWxH mm 780x1.000x550
Packing LxWxH mm 845x1.170x600
Net/gross weight kg 146/155 140/155 147/156
Liquid pipe mm (in) 9,53 (3/8”) 9,53 (3/8”) 12,7 (1/2”)
Gas pipe mm (in) 22,2 (7/8”) 22,2 (7/8”) 25,4 (1”)
Piping dimension
Oil balance pipe mm (in) 6,35 (1/4”)
Water side pipe mm 31,8
Max qty. indoor units connection pcs 13 16 20
Operating conditions
Piping Lenght
SYSVRF 532 WATER EVO SYSVRF 252 WATER EVO HP R SYSVRF JOINT
53,2/58,5 29
HP R + SYSVRF 280 WATER EVO HP R OUT 02 HP
SYSVRF 615 WATER EVO SYSVRF 280 WATER EVO HP R SYSVRF JOINT
61,5/69 36
HP R + SYSVRF 335 WATER EVO HP R OUT 02 HP
Cooling/ Max.
Recommended Outdoor
Design Heating Model indoor
combination branch
capacity kW unit qty
SYSVRF 784 WATER EVO SYSVRF 232 WATER EVO HP R x2 SYSVRF JOINT
78,4/85,5 43
HP R + SYSVRF 280 WATER EVO HR R OUT 03 HP
SYSVRF 895 WATER EVO SYSVRF 280 WATER EVO HP R x2 SYSVRF JOINT
89,5/100,5 53
HP R + SYSVRF 335 WATER EVO HP R OUT 03 HP
SYSVRF 950 WATER EVO SYSVRF 280 WATER EVO HP R + SYSVRF JOINT
95/106,5 56
HP R SYSVRF 335 WATER EVO HP R x2 OUT 03 HP
280
Accessories/option Wired
controller
Wired controller SYS WC 29 with address
54
50
SYS WC 120
9
45
15
343
54
50
9
64
280
203 835
56
12
262 1194
54
50
9
SYSVRF
203
WALL 36/45/56 Q 835
315
60
45
15
315
223 990
60
45
15
223 990
343
64
56
12
343
262 1194
64
VRF Wall indoor units | 31
Technical features
Model Indoor unit SYSVRF WALL 22 Q WALL 28 Q WALL 36 Q WALL 45 Q WALL 56 Q WALL 71 Q WALL 80 Q
Art. no. 314767 314768 314769 314770 314771 314785 314786
Power Supply V/Ph/Hz 220-240/1/50 or 60
Cooling capacity kW 2,2 2,8 3,6 4,5 5,6 7,1 8,0
Power input kW 8 9 19 19 27 49 53
Current 0,27 0,31 0,43 0,44 0,58 0,60 0,60
Heating capacity kW 2,4 3,2 4,0 5,0 6,3 8,0 9,0
Power input kW 8 9 19 19 27 49 53
Current 0,27 0,31 0,43 0,44 0,58 0,60 0,60
Indoor fan motor DC motor DC motor
Air flow (H/M/L) m3/h 420/390/360 420/370/320 660/570/490 590/510/420 750/650/550 1.200/1.000/810
Sound pressure level (H/M/L) dB(A) 31/30/29 31/30/29 33/32/30 35/33/31 38/36/34 44/39/36
Dimension LxWxH mm 835x203x280 990x223x315 1.194x262x343
Packing LxWxH mm 935x320x385 1.085x335x420 1.290x375x460
Net/gross weight kg 8,4/12,1 9,5/13,1 11,4/15,5 12,8/16,9 12,8/16,9 17,0/22,4
Refrigerant R410A R410A
Liquid pipe mm (in) 6,4 (1/4") 9,5 (3/8")
Piping dimension
Gas pipe mm (in) 12,7 (1/2") 15,9 (5/8")
Drain piping mm 16,5 16,5
Operating ambient temp. range °C Cooling +17 … +32 / Heating +10 … +28
Operating conditions
control controller
Infrared receiver and remote SYS RM 02 SYS RM 02 SYS WC 29
with address setting function as standard equipment. (standard) Art. no. 314772
(optional)
Power supply 50Hz or 60Hz.
647 (panel)
523
570
Accessories/option Wired
controller
Wired controller SYS WC 29 with address SYS WC 120
setting function for heat pump system. Art. no. 314774
(optional)
Wired controller SYS WC 120 for heat
recovery system.
545
Dimensions 570
647 (panel)
Connecting points of refrigerant pipe (gas/liquid side)
Drain point
60
Hook
Main body
647 (panel)
523
570
Nut
260
50
Ceiling 600 Panel
545
570
647 (panel)
VRF Compact Cassette indoor units | 33
Technical features
Operating conditions
55
950
680
840
Dimensions
950
780 105 Φ32 Drain pipe B
A outter diameter 70 Φ75 New air
supply orifice
≥20
55
950
680
840
146
Ceiling 46
Panel
Main body
B 840
Φ75 New air
supply orifice 904
CASSETTE CASSETTE
≥20 CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE
Indoor unit SYSVRF
28 Q 36 Q 45 Q 56 Q 71 Q 90 Q 112 Q 140 Q
A mm 230 230 300
B mm 170 170 190
146
Ceiling 46
Panel
Main body
VRF Cassette indoor units | 35
Technical features
1200/996/ 1727/1426/
Air flow (H/M/L) m3/h 982/832/677 1029/857/704 1596/1239/1034
748 1224
Sound pressure level (H/M/L) dB(A) 42/37/32 43/38/34 45/39/34 47/41/36 50/45/35
Dimension (LxWxH) mm 840x840x230 840x840x300
Unit Packing (LxWxH) mm 955x955x247 955x955x317
Net/gross weight kg 24/28 26/30 32/37
Dimension (LxWxH) mm 950x950x46
Panel Packing (LxWxH) mm 1.000x1.000x60
Net/gross weight kg 6/8
Refrigerant R410A
Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3/8”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm 32
Operating ambient temp. range °C Cooling +17...+32 / Heating +10...+28
Operating conditions
Dimensions
1015
290
VRF Cassette 1way indoor units | 37
Technical features
Operating conditions
Dimensions
591
436
57 1172 241
701 129 129 185 44
Fresh air 257
connector 120 104 91
Φ 32
44
51
91
117
171
Φ160
176
192
45
151
299
299
5
12
Φ
Φ 32
42~45
680
1430
dimension 640
dimension 680
Hanging screw
Machine body
size 591
151
701 129
20
44
VRF Cassette 2way indoor units | 39
Technical features
Operating conditions
SYS RM 02
and auto vertical swing function.
133,5
(standard)
98
175
Models 90,112 and 140 equipped with high efficient
207
200
DC fan motor.
655
Wide angle air flow. Wired
Low noise operation. controller
SYS WC 29
Washable air filter, easy for insertion and removal.
Art. no. 314772
Built-in electronic expansion valve (EXV) ensuring (optional)
175
recovery system.
655
995 35
198,2
39,5
401 906,5 371 1670
35 1542,3
198,2
133,5
98
235
401 371 112,5
69,5
207
133,5
98
175
144
184,5
200
255,2
655
207
200
655
675
SYSVRF CEILING 90 Q
1284,5
1194,5
547 515
198,2
1284,5 39,5
1194,5 37
547 515
133,5
98
198,2
175
39,5
37
133,5
98
200
175
655
200
655
1670
1542,3
724,5 630,5
VRF Ceiling/Floor indoor units | 41
Technical features
1.379x
Packing (LxWxH) mm 1.089x296x744 1.764x329x760
296x744
Net/gross weight kg 26/32 28/34 34,5/41 54/59
Refrigerant R410A
Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3/8”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm 16
Operating ambient temp. range °C Cooling +17...+32 / Heating +10...+28
Operating conditions
Accessories/option
Wired controller SYS WC 120 for heat
recovery system.
C
F mm 45 65 65 80
G mm 732 933 933 969
H mm 17 35 35 40
VRF Duct indoor units | 43
Technical features
DUCT DUCT DUCT DUCT DUCT DUCT DUCT DUCT DUCT DUCT
Model Indoor unit SYSVRF
15 Q 22 Q 28 Q 36 Q 45 Q 56 Q 71 Q 90 Q 112 Q 140 Q
Art. no. with SYS WC 29 314784 314761 314762 314763 314764 314765 314766 314261 314262 314258
Art. no. with SYS RM 02 314846 314847 314848 314849 314850 314851 314852 314853 314854 314855
Power Supply V/Ph/Hz 220-240/1/50 or 60
Cooling capacity kW 1,5 2,2 2,8 3,6 4,5 5,6 7,1 9,0 11,2 14,0
Power Input W 39 39 39 45 58 89 - 108 178 204
Current A 0,31 0,31 0,31 0,33 0,36 0,36 0,47 1,0 1,8 1,55
Heating capacity kW 1,7 2,6 3,2 4,0 5,0 6,3 8,0 10,0 12,5 15,5
Power Input W 39 39 39 45 58 89 - 108 178 204
Current A 0,31 0,31 0,31 0,33 0,36 0,36 0,47 1,0 1,8 1,55
Indoor fan motor DC motor
1.400/ 1.800/ 2.250/
460/ 460/ 460/ 540/ 740/ 860/ 1.100/
Air flow (H/M/L) m3/h 1.050/ 1.600/ 1.900/
420/360 420/360 420/360 469/480 640/550 760/630 940/790
880 1.400 1.460
Sound pressure level (H/M/L) dB(A) 35/33/31 35/34/31 36/34/31 37/36/33 38/37/33 38/37/33 40/38/34 44/38/37 47/41/37 47/42/38
40 /
External static pressure Rated/Range Pa 10 / 0-50 20 / 0-100
25-150
1.220x 1.290×
Dimension (LxHxW) mm 780x210x500 1.000x210x500 1.230×270×775
210x500 300×865
1.335x 1.400×
Packing (LxHxW) mm 870×285×525 1.115x285x525 1.355×350×795
285x525 375×925
Net/gross weight kg 17,5 / 20,5 23/26 28/32 40/48 49/58
Refrigerant R410A
Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3/8”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm OD 25
Operating ambient temp. range °C Cooling +17…+32 / Heating +10…+28
Operating conditions
Dimensions
1121 75
SYSVRF DUCT HP 71/112 Q SYSVRF DUCT HP 140 Q
60
96
952
856 135 930 88
86
29
214
343
56
82
82
85
249
270
420
420
Plastic
cover
Plastic
cover
Electrical 68 24
control box 46 Electrical
control box
378
343
50
VRF Duct HP indoor units | 45
Technical features
Model Indoor unit SYSVRF DUCT HP 71 Q DUCT HP 112 Q DUCT HP 140 Q DUCT HP 200 Q DUCT HP 280 Q
Art. no. 314560 314561 314562 314563 314564
Power Supply V/Ph/Hz 220-240/1/50 or 60
Cooling capacity kW 7,1 11,2 14,0 20,0 28,0
Power Input W 180 380 420 800 800
Current A 1,4 2,9 4,5 6,0 6,0
Heating capacity kW 8,0 12,5 16,0 22,5 31,5
Power Input W 180 380 420 800 800
Current A 1,4 2,9 4,5 6,0 6,0
Indoor fan motor DC fan motor
1.500/ 2.080/ 2.860/ 4.820/ 4.870/
Air flow (H/M/L) m3/h
1.390/1.250 1.930/1.710 2.440/2.010 4.660/4.620 4.760/4.690
Sound pressure level (H/M/L) dB(A) 46/41/42 50/47/45 53/50/48 57/53/50 57/53/50
MCAC -VTSM -2015-07 High Static Pressure Duct Unit with DC Fan Motor
External static pressure Rated/Range Pa 25 / 0~196 37 / 0~196 50 / 0~196 62 / 40~200 62 / 40~200
7. Fan Performance
Dimension (LxWxH) mm 856x690x420 856x690x420 1.200x600x400 1.356x763x470
Heating capacity and cooling capacity are tested under the standard allowablestatic pressure;
1.356x763x470
Packing (LxWxH) themm
71 test1.090x768x440
static pressure is 25Pa, 80/90/112 test static
1.090x768x440 pressure is 37Pa, 140/160
1.436x768x450 test static pressure
1.509x964x570 is 50Pa,
the
1.509x964x570
MCAC -VTSM -2015-07 200/250/280Hightest
pressure
Static is 62Pa.
Pressure Duct Unit with DC Fan Motor
Net/gross weight kg 41/47 47/53 68/70 108/120 108/120
7. Fan Performance
Refrigerant
Heating capacity and cooling capacity are tested under the standard allowablestatic pressure;
R410A
the 71 test static pressure is 25Pa,
Liquid pipe 80/90/112 test static
mm pressure
(in) is 9,5
37Pa,(3/8”)
140/160 test static
9,5pressure
(3/8”) is 50Pa,
the 9,5 (3/8”) 9,5 (3/8”) (x2) 9,5 (3/8”) (x2)
Piping 200/250/280
dimension testpressure is 62Pa.
Gas pipe mm (in) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) (x2) 15,9 (5/8”) (x2)
Drain piping mm 32 32 32 32 32
Operating ambient temp. range °C Cooling +17…+32 / Heating +10…+28
MCAC -VTSM -2015-07 High Static Pressure Duct Unit with DC Fan Motor
7.Fan
Fan performance
Performance
Heating capacity and cooling capacity are tested under the standard allowablestatic pressure;
the 71 test static pressure is 25Pa, 80/90/112 test static pressure is 37Pa, 140/160 test static pressure is 50Pa,
the
SYSVRF DUCT HP 71 Q
200/250/280 test
pressure
High Static PressureisDuct
62Pa.
Unit with DC Fan Motor
SYSVRF DUCT HP 112 Q
17
If the external static pressure is too high, caused by extensive ducting for exam
each outlet may be reduced to insufficient levels.
17
So there’s a limit air flow volume for each speed, which is the min. airflow of th
the fan achieve the max. ESP, and indoor evaporator may protect by low temp
As well, there’s a limit airflow volume, which is the max. value at each speed.
duct for air-inlet and outlet, to prevent damage from the high temperature of m
Operating conditions
This is the available static pressure range which means the unit can run stably
Indoor unit Outdoor unit and the optimal
Piping static pressureLevel
lenght range difference
please refers to the Installation Manual.
17
46 | Exposed floor indoor unit
Dimensions
Mounting
A hole, 4 I
B
4xФ11
EXV
4xФ18
Gas side connector
Liquid side connector
D
G
C
E
F
J
Air inlet
grille
Indoor unit SYSVRF FLOOR EB 22 Q FLOOR EB 28 Q FLOOR EB 36 Q FLOOR EB 45 Q FLOOR EB 56 Q FLOOR EB 71 Q FLOOR EB 80 Q
A mm 1.000 1.200 1.500
B mm 725 925 1.225
C mm 672
D mm 592
E mm 284 310
F mm 232 258
G mm 345
H mm 94 100 100
I mm 220
J mm 150
Exposed floor indoor unit | 47
Technical features
Sound pressure level (H/M/L) dB(A) 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33
Operating conditions
Dimensions
Connecting point
of refrigerant pipe
Connecting point
of refrigerant pipe
C 212
MODEL A B C
FLOOR CB 22 mm 6,4 12,7 725
FLOOR CB 28 mm 6,4 12,7 725
FLOOR CB 36 mm 6,4 12,7 925
FLOOR CB 45 mm 6,4 12,7 925
FLOOR CB 56 mm 9,5 15,9 1.225
Concealed floor indoor unit | 49
Technical features
Sound pressure level (H/M/L) dB(A) 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33
Operating conditions
Dimensions
SYSVRF HRV 500/1000 Q SYSVRF HRV 2000 Q
L W 75
1550
Wire N2
N Door control H
box
W2
C Wire
Door control
box
Air exhaust By-pass Air return
vent system vent
Flange demension
W1 1400
L1 G
350
326
300
540
H 270 388
1370
N Φ194 Φ242
1650
N2 111 170
VRF Heat Recovery Ventilation | 51
Technical features
Model Indoor unit SYSVRF HRV 500 Q HRV 1000 Q HRV 2000 Q
Art. no. 314289 314290 314291
Power supply V/Ph/Hz 220-240/1/50 or 60
Indoor Fan motor DC fan motor
Nominal air flow (H) m3/h 500 1.000 2.000
External static pressure (H) Pa 80 100 170
Power input W 170 360 1.340
Enthalpy exchange efficiency/
% 78,2/80,4 76,9/78,6 78,7/80,3
Cooling / Heating
Temperature exchange efficiency
% 76,1/76,1 75,8/75,8 77,2/77,2
Cooling / Heating
Sound pressure level (H) dB(A) 35 40 53
Dimensions (LxWxH) mm 1.020x1.036x270 1.276x1.269x388 1.650x1.470x540
Packing (LxWxH) mm 1.120x1.120x452 1.390x1.350x570 1.760x1.580x720
Net/gross weight kg 35/60 69/100 165/247
Duct connection dimensions mm ⌀194 ⌀242 346x326
Ambient condition °C -7…+43/ max 80% RH
Fan performance
SYSVRF HRV 500 Q SYSVRF HRV 1000 Q SYSVRF HRV 2000 Q
675 1300 3050
650 1250 2900
Air flow (m3/h)
External static pressure (Pa) External static pressure (Pa) External static pressure (Pa)
In mild climate areas or seasons, when temperature and It is also one kind of bypass mode with exhaust fan speed
humidity level difference between indoor and outdoor is higher than air supply fan speed. It can be used in mild
small, the unit works as conventional ventilation fan. Both climate area where large amount exhaust air needs to be
supply fan and exhaust fan works at the same speed (Hi/ expelled.
mid/low/auto).
Auto mode
Air supply mode The controller chooses heat exchange mode or bypass
It is one kind of bypass mode with air supply fan speed mode according to the temperature difference between
higher than exhaust fan speed. It can be used in mild outdoor and indoor temperature. Both the two fans work
climate area where large amount fresh air is needed. at low speed.
Operating conditions
Connection to DX coil
SYSVRF AHU
Features
The SYSVRF AHU 5HP, 10HP and 20HP can be used
to connect the SYSVRF outdoor units to an external DX
coil with capacity from 9 kW to 56 kW.
max 8 m
SYSVRF indoor units
SYSVRF
AHU
max
175 m
SYSVRF
outdoor FRICO Air Curtain
unit
max 8 m
SYSVRF AHU SYSTEMAIR Air Handling Unit
Technical features
Model AHU box (1st generation) SYSVRF AHU 5HP SYSVRF AHU 10HP SYSVRF AHU 20HP
Model AHU box (2nd generation) SYSVRF AHU 5HP S SYSVRF AHU 10HP S SYSVRF AHU 20HP S
Art. no. (1st generation) 314188 314189 314190
Art. no. (2nd generation) 313395 313396 313397
Power supply V/Ph/Hz 220-240/1/50, 208-230/1/60
DX coil capacity kW 9-20 20-36 36-56
Air volume m3/h 1.400-2.700 3.000-4.500 5.400-7.500
Dimensions (LxWxH) mm 375x350x150
Packing (LxWxH) mm 490x240x420
Piping diameters in/out mm 8/8 12,7/12,7 '16/16
IP-class IP X0 IP X0 IP X0
Air return temperature range °C Cooling +17 … +43 / Heating -5 … +30 / 80% / humidity
VRF connection to AHU | 53
SYSVRF selection
and designing software
Selection and designing software for all SYSVRF systems, 2-pipe, 3-pipe and Mini-VRF.
Main tasks:
Calculation of the heat loads and selection of the
necessary cooling /heating capacity, type and location
of outdoor and indoor units.
Calculation of the refrigerant piping diameters and
the required additional amount of refrigerant.
Selection of an optimal set of piping joints.
Building Management System.
Correction of the performance of indoor units.
Automatic check of the circuit for compliance
requirements and limits on the maximum length of
refrigerant pipelines and indoor-outdoor elevations.
Conclusion of project documentation - specification
(Excel), a detailed specification with the drawings
(Word), and print out of all documents.
Selection of the DX-coil connected to the SYSVRF AHU
box.
54 | VRF control systems
Control systems
Group controller for indoor units SYS WC 150, Art. no. 314787
The group controller allows to control up to 16 indoor units from a single local controller.
It can be matched to:
Infrared remote controller SYS RM 02, Art. no. 314138
Wired controlled SYS WC 29, Art. no. 314772
VRF control systems | 55
Centralized controller with touch-key buttons SYS CWC 30, Art. no. 314773
The centralized remote controller is intended to control a group of indoor units (up to
64 indoor units).
Main functions:
Turn On/Off
Setting mode Cool/Heat/Auto/Dry/Fan
Temperature setting
Fan speed selection High/Medium/Low/Auto
Air swing function
24h On/Off timer
Silent mode operation
Locking the controller buttons
Indication of air filter cleaning
Turn on/off the LCD backlight
The centralized controller allows to set all operating parameters for each indoor unit
separately or for a group of indoor units at the same time.
It provides the ability to connect to a PC via a converter RS485/RS232.
Centralized controller with weekly timer SYS CWC 09, Art. no. 314141
The centralized remote controller is intended to control a group of indoor units (up to
64 indoor units). It performs the same functions of the centralized controller SYS CWC
30, with the possibility of drawing up management programs for the week with up to 4
different modes per day.
It doesn’t have the R485 port for the connection to a PC.
Central controller for outdoor units SYS CWC 02, Art. no. 314142
Remote control designed to monitor the SYSVRF outdoor units (max. 32 outdoor units
/ 8 systems).
This controller greatly simplifies the maintenance of the SYSVRF installation, since it has
an error indicator and allows the technician to check the operating status of all major
components of the system, monitor temperature, fan speed, operation of electronic
expansion devices, operation of compressors, etc...
If the outdoor unit is equipped with a power meter, the controller performs an accounting
function of the consumed electricity.
SYS CWC 02 can communicate with a PC through a RS485/RS232 converter and one PC
can connect up to 16 outdoor controllers SYS CWC 02.
Main functions:
Individual control with system blocks: switching modes, setting temperatures, lock local controllers.
User can set limits to any parameter of indoor unit, such as cooling/heating temperature set-point, fan speed, operating
mode, etc…
Simple schedule control, automatically performs facility start/stop control, switches the operating mode, sets temperatures
and enabling/disabling the remote control according to the present time schedule.
Electricity charge apportionment can be performed easily for the power consumed, when billing users for air conditioning
power charges, such as tenants in a commercial building, offices in a rental building, or rooms in a hotel.
Automatic backup web-gateway to SD-card in the event of failures of the power supply or system fault. Storing data
on a hard disk in the last three months.
Indication of filter cleaning.
Fault and reported them to mobile communications.
Emergency stop function and connection to external signals through contacts.
Maximum:
• 1024 indoor units;
• 256 outdoor units;
• 64 independent refrigerant circuits.
VRF control systems | 57
RM 02 WC 29/120
Мax. 64
Bacnet CWC 30
BMS
Мax. 64
CWC 30
CWC 08
Мax. 64
CWC 30
C C 02
CWC
Modbus
Modbus
BMS RM 02 WC 29/120
Мax. 64
Мax. 4
CWC 18
Lonwork
BMS
RM 02 WC 29/120
CWC 64 Мax. 64
Picture
CASSETTE MINI l -- l
CASSETTE l -- l
DUCT l -- l
CEILING l -- l
WALL l -- l
DUCT HP l -- l
CASSETTE 1W l -- l
CASSETTE 2W l -- l
FLOOR EB l -- l
FLOOR CB l -- l
HRV -- -- l --
-- --
l
only with SIEMENS only with SYSTEMAIR only with SYSTEMAIR only with SYSTEMAIR only with SYSTEMAIR only with SYSTEMAIR only with SYSTEMAIR
controller controller controller controller controller controller controller
60 | VRF piping joint
Outdoor unit
Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use
SYSVRF JOINT OUT 02 HP 314146 255x150x185 1,5 Connect two outdoor units of SYSVRF AIR EVO HP R series
SYSVRF JOINT OUT 03 HP 314147 345x160x285 3,4 Connect three outdoor units of SYSVRF AIR EVO HP R series
SYSVRF JOINT OUT 04 HP 314148 475x165x300 4,8 Connect four outdoor units of SYSVRF AIR EVO HP R series
Indoor unit
Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use
SYSVRF JOINT IN 01 2P 314149 290x105x100 0,4 Capacity of connected indoor units < 23 kW
SYSVRF JOINT IN 02 2P 314150 290x105x100 0,6 Capacity of connected indoor units 23-33 kW
SYSVRF JOINT IN 03 2P 314151 310x130x125 0,9 Capacity of connected indoor units 33-92 kW
SYSVRF JOINT IN 04 2P 314152 350x180x170 1,5 Capacity of connected indoor units 92-135 kW
SYSVRF JOINT IN 05 2P 314153 365x195x215 1,9 Capacity of connected indoor units > 135 kW
SYSVRF JOINT IN 06 2P 314154 390x230x255 3,1 Capacity of connected indoor units 185 kW and long piping
Outdoor unit
Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use
SYSVRF JOINT OUT 02 HR 314155 272×167×232 2,2 Connect two outdoor units of SYSVRF AIR EVO HR R series
SYSVRF JOINT OUT 03 HR 314156 472×157×312 5,0 Connect three outdoor units of SYSVRF AIR EVO HR R series
SYSVRF JOINT OUT 04 HR 314184 745×160×335 7,5 Connect four outdoor units of SYSVRF AIR EVO HR R series
Indoor unit
Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use
SYSVRF JOINT IN 01 3P 314157 257×127×107 0,8 Capacity of connected indoor units < 16,6kW
SYSVRF JOINT IN 02 3P 314158 287×137×107 0,9 Capacity of connected indoor units 16,6-33kW
SYSVRF JOINT IN 03 3P 314159 297×167×177 1,4 Capacity of connected indoor units 33-66kW
SYSVRF JOINT IN 04 3P 314160 372×197×187 2,3 Capacity of connected indoor units 66-92kW
SYSVRF JOINT IN 05 3P 314185 432×222×227 3,3 Capacity of connected indoor units > 92kW
Italia
Systemair srl
Via XXV Aprile, 29
www.systemair.it
Tel. +39 0362 680 1
20825 Barlassina (MB)