Vrf-Catalogue 2017 GB

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 62

Fans | Air Handling Units | Air Distribution Products | Air Conditioning | Fire Safety | Air Curtains and Heating

Products | Tunnel Fans

Air conditioning
VRF systems
Systemair Trust

We consider your trust in us as a supplier an important goal. It is always included in our work
on all levels and in all areas whether it is a question of cooperation, quality, deliveries or
documentation. This catalogue is of course a part of this work.

With this catalogue, which features products of air conditioning, we want to give you as a
customer a general overview of what Systemair can offer within this field. More detailed
information is available in our Online catalogue at www.systemair.com and as downloadable
software. Systemair’s range of fans, air distribution products and accessories also appears in our
printed main catalogue.

Our product development leads the field - latest technologies in unitdesign, fans, motors,
heat recovery, chillers, fan coils,... interact to give high efficiency and with that low power
consumption. Systemair has grown each year since the start and we aim to continue with this
trend.

Systemair strives to be a reliable supplier of quality products. We help our customers to focus on
their own business. Reliable deliveres give the customers greater possibilities to quickly complete
a job, and move on to the next project.

At Systemair we call this Trust.

© Systemair 2017.
Systemair reserves the right to make technical changes. For updated documentation, please refer to www.systemair.com
Content | 3

Content
Systemair 4

Product Range 6

Application 8

VRF systems 10

Mini VRF SYSVRF AIR EVO HP 14


VRF Heat Pump SYSVRF AIR EVO HP 16
VRF Heat Recovery SYSVRF AIR EVO HR 20
VRF Heat Recovery switch module SYSVRF BOX HR 22
VRF Heat Recovery combination 24
VRF Heat Pump water-cooled SYSVRF WATER EVO HP 26
VRF water-cooled combination 28
VRF Wall Indoor units SYSVRF WALL 30
VRF Compact Cassette indoor units SYSVRF CASSETTE MINI 32

VRF Cassette indoor units SYSVRF CASSETTE 34

VRF Cassette 1way indoor units SYSVRF CASSETTE 1W 36

VRF Cassette 2way indoor units SYSVRF CASSETTE 2W 38

VRF Ceiling/Floor indoor units SYSVRF CEILING 40

VRF Duct indoor units SYSVRF DUCT 42

VRF Duct HP indoor units SYSVRF DUCT HP 44

Exposed floor indoor unit SYSVRF FLOOR EB 46

Concealed floor indoor unit SYSVRF FLOOR CB 48

VRF Heat Recovery Ventilation SYSVRF HRV 50

VRF connection to AHU SYSVRF AHU 52

VRF control systems 54


4 | Systemair

Manufacturing around the world

Skinnskatteberg, Sweden Mühlheim an der Ruhr, Germany Hyderabad, India


The Group headquarters, distribution center Production of air handling units for swimming Production of air distribution products.
and largest production site. Production of pool halls and comfort ventilation.
compact air handling units, a wide range of Greater Noida, New Delhi, India
fans and accessories, air curtains and fan Ukmergé, Lithuania Production of duct, axial and box fans, air
heaters. Production of residential units and large air handling units and air distribution products.
handling units.
Hässleholm, Sweden Kuala Lumpur, Malaysia
Production of heating products for air handling Maribor, Slovenia Production of duct and axial fans.
units, fan heaters and dehumidifiers. Production of high-temperature fans for
smoke extract ventilation. Johannesburg, South Africa
Windischbuch, Germany Production of axial fans.
Production facility and distribution center, Aarhus, Denmark
specializing in engineered products. Production of large air handling units. Lenexa, USA
Manufacturing and distribution center of
Langenfeld, Germany Bratislava, Slovakia ventilation products.
Production of air curtains. Production of air distribution products and fire
dampers.
Systemair | 5

Our commitment to quality Save energy and lower running costs!


Systemair is certified in accordance with ISO Our “Green Ventilation” label highlights
9001, ISO 14001, ATEX and European fire products that combine energy economy with
safety standard EN 12101-3. Our research energy efficiency, offering end users high
and development laboratories are among the energy-saving potential. The ErP symbol
most modern in Europe. Our measurements indicates that the product fulfills EU demands
are made in accordance with international on energy consumption.
standards such as AMCA and ISO.

Skinnskatteberg, Sweden
Eidsvoll, Norway
Hässleholm, Sweden
Aarhus, Denmark Ukmergé, Lithuania
Windischbuch, Helmstadt, Langenfeld, Waalwijk, The Netherlands
Mühlheim a.d.R., Winterbach, Germany Pardubice, Czech
Bouctouche, Canada Bratislava, Slovakia
Tillières, France
Tillsonburg, Canada Maribor, Slovenia
Milan, Italy
Istanbul, Turkey
Kansas City, USA Madrid, Spain

Wujiang, China
New Delhi, India

Hyderabad, India

Kuala Lumpur, Malaysia

São Paulo, Brazil


Johannesburg, South Africa

Milan, Italy Eidsvoll, Norway Helmstadt, Germany


Production of liquid and air-cooled chillers and Production of air handling units. Manufacturing of rotary heat exchangers.
heat pumps for comfort cooling.
Istanbul, Turkey Sau Paolo, Brasil
Tilliéres, France Production of air handling units and fan coils. Manufacturing of air handling units and ac-
Production of air conditioning products for cessories.
the commercial market. Waalwijk, The Netherlands
Production of air handling units. Wujiang, China
Madrid, Spain Production of air handling units
Production of large air handling units and Pardubice, Czech Rep.
box fans. Development and manufacturing of air han-
dling units and air curtains
Bouctouche, Canada
Production of air handling units. Winterbach, Germany
Development and production of high end air
Tillsonburg, Canada air curtains.
Production of air handling units.
6 | Product range

Product range

Systemair has an extensive range of ventilation products: fans including smoke


extract, tunnel and car park fans, explosion proof fans, air handling units
from large central units to small residential units with energy recovery, air
distribution products and fire dampers. These products are installed in a variety
of locations, including homes, offices, healthcare premises, shops, industrial
buildings, tunnels, parking garages, training facilities, sports centres etc.

Fans Duct fans Rectangular duct fans


Systemair has the wider range of Duct fans for circular duct installation. Duct fans with rectangular connec-
fans for use in different applications. tion.
Our range includes any type of fans,
from circular ducts – hystorical
product – boxed up to those of
extraction, axial, and explosion-proof
for the extraction of fumes.
All products listed above are made in
different dimensions from 100 mm
in diameter to fans of large size for
tunnel. All our fans are designed to Centrifugal fans Square duct fans
meet the strict requirements, easy to Centrifugal supply single fans. For different applications, there are
use, high quality and durability. models for ambient with high tem-
perature.

Axial fans Roof fans


Axial fans for duct or wall application. Roof fans with circular or square con-
nection.

Explosion proof fans Jet Axial Fans High temperature fans


Explosion proof fans in duct, roof or Jet Axial Fans for car park, tunnels Systemair provides high fire resist-
wall design. and air overpression. ance fans till 600°C/2 hours.
Product range | 7

Air handling units


Systemair produces a wide range
of air handling units for several ap-
plications, from small office to large
industrial building. All range is been
developped to satisfy strict needs of
low energy consumption.

Fire and smoke dampers Smoke extract fans Fire & smoke dampers
High efficient fans to extract the Dampers that reduce the spread of
combustion smoke. smoke and fire.

Residential ventilation Residential units Cooker hoods


Complete energy-efficient air han- For homes with living areas of 60- Ideal for capturing odours even at
dling units with heat recovery and 320 m2. low airflows.
built in control systems.
Designed to be mounted over the
cooker, on walls or horizontally in
attics.

Air distribution products Supply, extract & transfer devices Nozzle diffusers
The range also includes a wide For mounting in ceilings or walls. Optimum flexibility and comfort in air
selection of air distribution products distribution for rooms.
and accessories.

Air Conditioning
The strengh point of Systemair
Air Conditioning products is a wide
range with several options and
accessories: chiller, water terminal,
close control, roof top, water source
heat pump etc.
Applications
Schools
In buildings for school, the load to be disposed is variable during the day due to the
presence of people only for some periods, thus it is mandatory to control the users
requirements during daily plant use. Systemair offers a wide range of equipment
suitable for this purpose, the fan coils with EC motors allow to obtain the required
flexibility.

Offices
In buildings for tertiary application, the air conditioning and the ventilation are
necessary during the day.
The heat loads to be removed are generally generated by people present, from the
lighting system, from solar radiation and by machines.
Normally it is necessary the use of chillers, Heat Pump to produce cold and/or hot
water to be sent to hydronic (fan coils, cassettes, ducted) to obtain an optimum air
conditioning of offices.
Commercial buildings
Normally the number of people varies continuously; the optimal solution would
be to use machinery for the conditioning with variable flow and with constant
monitoring of concentration of pollutants (VOC and CO2). Systemair products can
easily meet the plantʼs requirement .

Industry
Industrial plants generate a large amount of heat that must be dissipated in the
appropriate way. Systemair offers a wide range of products (chillers from 20 kW
to 1.680 kW) that can be readily integrated industrial installation. The chiller can be
used both for air conditioning and for the cooling equipment process (production of
chilled water up to -10°C).

Hotels
In the hotel rooms, it is needed a high level of comfort with the minimum impact with
respect to the noise level. Systemair ducted products equipped with EC motors fully
comply with requirements efficiency, cooling capacity and sound impact , required by
this type of installations.
10 | VRF systems

SYSVRF
VRF systems | 11

SYSVRF multi-zone solutions:


light commercial and commercial VRF systems
The SYSVRF modular systems are most valuable for room All SYSVRF systems are equipped with DC Inverter
space from 100 to 1000 sq.m. with large independence compressors and DC Inverter fans which gives enhanced
of climatic zones - hotels, restaurants, retail, office system performance and very low operating noise.
buildings, etc. Up to 4 modular outdoor units can be The new generation of 3-pipe systems are equipped with
combined in one single refrigerant system thus reaching all DC Inverter compressor which delivers outstanding
up to 246kW of cooling capacity and connecting up to 64 comfort pleasure and reduces tremendously the
indoor units. In the same system they are able to fulfill electricity consumption.
the increasing demands of air comfort still having low
operating costs.

SYSVRF of Systemair are available with different configurations: the typical heat pump Mini and Modular 2-pipe outdoor
units Air-cooled or Water-cooled and the superior Modular heat recovery 3-pipe units.

SYSVRF Mini and SYSVRF Modular systems

SYSVRF AIR EVO HP Mini 14 SYSVRF DUCT 42

SYSVRF AIR EVO HP 16 SYSVRF DUCT HP 44

SYSVRF AIR EVO HR 20 SYSVRF FLOOR EB 46

SYSVRF WATER EVO HP 26 SYSVRF FLOOR CB 48

SYSVRF WALL 30 SYSVRF HRV 50

SYSVRF CASSETTE MINI 32 SYSVRF AHU 52

SYSVRF CASSETTE 34 SYSVRF selection software 53

SYSVRF CASSETTE 1 WAY 36 SYSVRFsystems 54

SYSVRF CASSETTE 2 WAY 38 SYSVRF JOINT accessories 60

SYSVRF CEILING 40
12 | VRF systems

VRF Systemair- SYSVRF


Multi-zone air conditioning system A balanced lineup
VRF systems are most beneficial for space up to 1500- The lineup of multizone VRF series are continuously
2000 sq.m. with large independence of climatic zones – optimized. In response to market demands Systemair
hotels, restaurants, retail space, office buildings, etc. offers several types and sizes of indoor units: wall-
In the same system they are able to fulfill the increasing mounted, cassette, floor-ceiling and duct.
demands of the parameters of air in each room and still Outdoor units Mini, despite the compact dimensions ,
have low operating costs. solve different tasks of air conditioning on small objects.
Four modular outdoor units can be combined in one
refrigerant system thus reaching a total cooling capacity
of up to 246 kW.
Separately, to highlight the 3 Pipe heat recovery system
for indipendent and simultaneous cooling and heating
operation.

Continuous development in the field of management


In modern air-conditioning systems the demand for
automation and control systems integrated with other
infrastructure building systems is continuously increasing.
These are exactly the principles on the basic of the
development of the control systems of Systemair.
In addition to the traditional control systems of air
conditioning, the user deals with different possibilities of
The most comfortable temperature control that can solve the various needs of the building
An important advantage of the multi-zone air-conditioning management such as the possibility of control via
is a smooth and rapid achievement of a comfortable personal computer and Internet network connection.
temperature, as well as maintaining the specified
parameters accurate to ± 0,5 °C. Such high performance Simplicity of design
was achieved thanks to an accurate control of the Systemair provides full integration and coordination of
refrigerant flow and the mechanism of redistribution of all elements of a multizone system, greatly simplifies
refrigerant between the several units, implemented with the task of the designer. The selection process can be
the help of electronic expansion valves. performed in maximum short period of time by using a
simple and complete selection and designing software.
High energy efficiency
The efficiency of multi-zone systems is very high, because
each time the electric power is consumed as much as
necessary to carry out user requirements.
If the indoor units work only in a few areas of the building,
then the power consumption is reduced proportionally by
changing the refrigerant flow.

Low noise
Low noise of both outdoor and indoor units makes the job
a multizone system virtually inconspicuous.
VRF systems | 13

SYSVRF lineup
In 2014 Systemair launched a new generation of VRF multi-zone systems - the SYSVRF series. The basis principle of work
lies on the advantages of the DC Inverter technology and scroll compressors and the achieved results far exceed the high
standards set by the industry.
Through the use of modern technologies and implementation of their own development has significantly improved energy
efficiency and decreased the noise level, with compact dimensions, increased ease of installation and maintenance,
greatly expanded the range of application from light commercial to large commercial spaces.

SYSVRF outdoor units

SYSVRF mini SYSVRF AIR EVO HR SYSVRF AIR EVO HP SYSVRF WATER EVO HP
2 Pipe Heat Pump Modular 3 Pipe Heat Recovery Modular 2 Pipe Heat Pump Modular 2 Pipe Heat Pump
8,0-22,4 kW 25,0-180,0 kW 25,0 - 246,0 kW 25,0 - 100,0 kW

SYSVRF WALL SYSVRF CEILING SYSVRF CASSETTE MINI

2,2-8,0 kW 3,6-14,0 kW 1,5-5,6 kW


SYSVRF Indoor units

SYSVRF CASSETTE SYSVRF CASSETTE 1 WAY SYSVRF CASSETTE 2 WAY

2,8-14,0 kW 1,8-7,1 kW 2,2-5,6 kW

SYSVRF DUCT SYSVRF DUCT HP SYSVRF HRV

1,5-14,0 kW 7,1-28,0 kW 500-2.000 m3/h

SYSVRF FLOOR EB SYSVRF FLOOR CB SYSVRF AHU

2,2-8,0 kW 2,2-8,0 kW 9,0-56 kW

Compatible outdoor and indoor series


Outdoor units of the SYSVRF Mini, Heat Pump and Heat Recovery series are compatible with all types of SYSVRF indoor
units. There are 10 different types of indoor units available with capacity from 1,5 kW to 28,0 kW, making the total number
of indoor units equal to 69 different types and capacities.
The ventilation function can be provided through the SYSVRF HRV units or through the combination of a Systemair air
handling unit with the control module SYSVRF AHU.
14 | Mini VRF

Mini VRF Heat Pump Outdoor Units


SYSVRF AIR EVO HP
Features
Full DC Inverter Mini VRF with DC Inverter compressor
and DC fan motor.
 Compact size and long piping system.
High efficiency at partial load.
Inverter Rotary compressor providing wide capacity
output from 10% to 100% evenly.
Centralized control, BMS connection and web access
potential.
Hydrophilic Blue Fin coil enhances durability
and protection against corrosion.
Piping connection in four different directions makes
simple the installation of outdoor unit. With the branch SYSVRF BRANCH 04 MINI (Art.
Maximum 11 indoor units connection. no. 314803) the installation is easy and safe, all
Indoor unit combination total capacity index from 45% connections from outdoor unit and indoor units are
to 130%. flanged, which greatly simplifies field installations.

Dimensions
SYSVRF 120 to 180 and 224 SYSVRF 080
H

1075

A
Model 080 120 to 180 224
A 990 900 1.120

B
B 624 600 874
C 354 348 440
D 336 320 400
E 396 400 528
E
D

F
C

F 366 360 494


H 966 1.327 1.558
Mini VRF | 15

Technical features

080 AIR EVO 120 AIR EVO 140 AIR EVO 160 AIR EVO 180 AIR EVO 224 AIR EVO
Model Outdoor unit SYSVRF
HP Q HP Q HP R HP R HP R HP R
Art. no. 314392 314089 314092 314094 314777 314778
Power supply V/Ph/Hz 220-240/1/50 380-415/3+N/50
Cooling capacity Nom / Eurovent kW 8,0 / 7,2 12,3 / 12,3 14,0 / 14,0 15,5 / 15,5 17,5 / 17,5 22,4 / -
Power input Nom / Eurovent kW 2,05 / 1,85 3,25 / 3,25 3,95 / 3,95 4,52 / 4,52 5,30 / 5,30 6,80 / -
EER Nom / Eurovent kW/ kW 3,9 / 3,9 3,78 / 3,78 3,54 / 3,54 3,43 / 3,43 3,30 / 3,30 3,29 / -
SEER/SCOP 5,1 / 3,8 7,1 / 4,11 6,68 / 3,96 6,42 / 3,83 6,21 / 3,92 6,21 / -
Heating capacity Nom / Eurovent kW 9,0 / 7,2 13,2 / 13,2 15,4 / 15,4 17,0 / 17,0 19,0 / 19,0 24,5 / -
Power input Nom / Eurovent kW 2,24 / 1,79 3,47 / 3,47 4,16 / 4,16 4,77 / 4,78 5,0 / 5,0 5,90 / -
COP Nom / Eurovent kW/ kW 4,02 / 4,02 3,80 / 3,80 3,70 / 3,70 3,56 / 3,56 3,80 / 3,80 4,15 / -
Max. current A 18,5 24,4 11,0 12,0 12,5 17,2
Quantity pcs 1 DC Inverter/ Rotary
Compressor Start-up method Soft start
Refrigerant oil ml 670+200 870+630 870+630 1.400+250 1.400+250 1.700+1.500
Type/motor 1 Axial / 1 DC motor 2 Axial / DC motor
Fan
Air flow m3/h 5.500 6.000 6.800 10.500
Sound power level dB(A) 67 70 71 72 74 74
Sound pressure level dB(A) 56 57 57 57 59 59
Type R410A
Refrigerant
Factory charge kg 2,95 3,3 3,9 3,9 4,5 6,2
Dimension (LxWxH) mm 1.075x396x966 900x400x1.327 1.120x528x1.558
Packing (LxWxH) mm 1.120x435x1100 1.030x435x1.456 1.270x565x1.720
Net/gross weight kg 62/67 95/106 95/106 100/111 107/118 147/163
Liquid pipe mm (in) 9,5 (3/8") 9,5 (3/8")
Piping dimension
Gas pipe mm (in) 15,9 (5/8") 19,1 (3/4")
Max quantity indoor units connection pcs 4 6 6 7 9 11

Operating ambient temperature range °C Cooling -15 … +46 / Heating -15 … +27

Eurovent data are defined for combination ratio equals to 100% and for Duct indoor units.

Operating conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB, 24°C WB 5m 0m
Heating mode 20°C DB, 15°C WB 7°C DB, 6°C WB 5m 0m

The sound pressure value may vary depending on ambient conditions.

Piping Lenght

Maximum piping equivalent lenght.


100 m
Maximum piping (the farthest IDU from the first indoor unit
branch) equivalent lenght.

Maximum outdoor unit-indoor unit drop height.


30 m 8m

Maximum indoor unit to indoor unit drop height. 20 m

Outdoor units SYSVRF AIR EVO HP Permitted value


Total piping lenght (actual) 100 m
Actual lenght 60 m (45 m SYSVRF 080)
Maximum piping
Piping lenght Equivavent lenght 70 m (50 m SYSVRF 080)
Piping (the farthest IDU from the first indoor unit branch)
20 m
equivalent lenght

Outdoor unit-indoor Outdoor unit up 30 m


Drop height unit drop height Outdoor unit down 20 m
Indoor unit to indoor unit drop height 8m
16 | VRF Heat Pump

Modular VRF Heat Pump Outdoor Units


SYSVRF AIR EVO HP
Features SYSVRF 252-280-335 SYSVRF 400-450-500-560-615
AIR EVO HP R AIR EVO HP R
Wide application area due to incredible piping length
and wide operating temperature range.
 Free modular combination of 4 basic units, up to a total
capacity of maximum 246 kW.
Top class energy efficiency.
DC Inverter Scroll compressor provinding wide capacity
output from 10% to 100% evenly.
All DC fan motor.
High performance of the new designed heat
exchanger.
External static pressure up to 60 Pa (factory option, 20
Pa standard).
Maximum 64 indoor unit connection.
Indoor unit combination total capacity index from 50%
to 130%.
Centralized control, BMS connection and web access
potential.

Dimensions
SYSVRF 252/280/335 AIR EVO HP R SYSVRF 400/450/500/560/615 AIR EVO HP R

1250
1615
1635

990
765
790
VRF Heat Pump | 17

Technical features

252 AIR 280 AIR 335 AIR 400 AIR 450 AIR EVO 500 AIR EVO 560 AIR EVO 615 AIR EVO
Model Outdoor unit SYSVRF
EVO HP R EVO HP R EVO HP R EVO HP R HP R HP R HP R HP R
Art. no. 314744 314745 314746 314747 314749 314750 314775 314776
Power supply V/Ph/Hz 380-415/3+N/50 or 60
Cooling capacity Nom/Eurovent kW 25,2 / 25,2 28 / 28 33,5 / 33,5 40 / 40 45 / 45 50 / 50 56 / 56 61,5 / 61,5
Power input Nom/Eurovent kW 5,36 / 6,25 6,22 / 7,49 7,79 / 8,91 9,3 / 11,7 10,98 / 13,6 12,82 / 14,7 14,51 / 16,5 16,44 / 19,8
EER Nom/Eurovent kW/ kW 4,7 / 4,03 4,5 / 3,74 4,3 / 3,76 4,3 / 3,43 4,1 / 3,30 3,9 / 3,40 3,86 / 3,40 3,74 / 3,10
SEER/SCOP 8,25 / 6,52 7,90 / 6,35 7,54 / 6,13 7,54 / 6,03 7,20 / 5,82 7,36 / 5,67 7,28 / 5,50 7,04 / 5,25
Heating capacity Nom/Eurovent kW 27 / 27 31,5 / 31,5 37,5 / 37,5 45 / 40 50 / 45 56 / 50 63 / 56 69 / 61,5
Power input Nom/Eurovent kW 4,82 / 5,30 5,94 / 6,89 7,65 / 8,91 9,38 / 9,83 10,87 / 11,69 13,18 / 12,5 15,29 / 14,0 17,12 / 16,2
COP Nom/Eurovent kW/ kW 5,6 / 5,09 5,3 / 4,57 4,9 / 4,21 4,8 / 4,07 4,6 / 3,85 4,25 / 4,00 4,12 / 4,00 4,03 / 3,80
Max. current A 25,6 25,6 27,5 35,2 35,2 42,4 53,4 53,4
Quantity pcs 1 DC Inverter/ Scroll 2 DC Inverter/ Scroll
Compressor Start-up method Soft start
Refrigerant oil ml 500 2x500
Type/motor 1 Axial / DC motor 2 Axial / DC motor
Fan Static pressure Pa 0-20 (20-60 factory option) 0-20 (20-60 factory option)
Air flow m3/h 12.000 12.000 12.000 14.000 14.000 16.000 16.000 16.000
Sound power level dB(A) 79 83 82 88 88 88 88 88
Sound pressure level dB(A) 59 63 62 66 66 66 66 66
Type/ motor R410A
Refrigerant
Factory charge kg 9 9 11 13 13 13 16 16
Dimension (LxWxH) mm 990x790x1635 1340x790x1635
Packing (LxWxH) mm 1055x855x1805 1405x855x1805
Net/gross weight kg 219/234 219/234 237/252 297/315 297/315 305/323 340/358 340/358
Liquid pipe mm (in) 12,7 (1/2") 15,9 (5/8")
Piping dimension
Gas pipe mm (in) 25,4 (1") 31,8 (1 1/4")
Max quantity indoor units connection pcs 13 16 20 23 26 29 33 36
Operating ambient temperature range °C Cooling -15 … +48 / Heating -20 … +24

Eurovent data are defined for combination ratio equals to 100% and for Duct indoor units.

Operating conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB, 24°C WB 5m 0m
Heating mode 20°C DB, 15°C WB 7°C DB, 6°C WB 5m 0m

The sound pressure value may vary depending on ambient conditions.

Piping Lenght

Maximum piping equivalent lenght.

Maximum piping (the farthest IDU from the first indoor unit
branch) equivalent lenght.

Maximum outdoor unit-indoor unit drop height.

Maximum indoor unit to indoor unit drop height.

Outdoor units SYSVRF 252 to 2000 AIR EVO HP R Permitted value


Total piping lenght (actual) 1.000 m
Actual lenght 175 m
Maximum piping
Piping lenght Equivavent lenght 200 m
Piping (the farthest IDU from the first indoor unit branch)
40 m/90 m*
equivalent lenght

Outdoor unit-indoor Outdoor unit down 110 m


Drop height unit drop height Outdoor unit up 90 m
Indoor unit to indoor unit drop height 30 m

* When the farthest pipe length is more than 40m, it needs to meet specific conditions according to the installation part of the technical manual.
18 | VRF Heat Pump combination

Outdoor unit combination SYSVRF AIR EVO HP


Cooling/ Max.
Recommended Outdoor
Design Heating Model indoor
combination branch
capacity kW unit qty

25,2/27 SYSVRF 252 AIR EVO HP R SYSVRF 252 AIR EVO HP R - 13

28/31,5 SYSVRF 280 AIR EVO HP R SYSVRF 280 AIR EVO HP R - 16

33,5/37,5 SYSVRF 335 AIR EVO HP R SYSVRF 335 AIR EVO HP R - 20

40/45 SYSVRF 400 AIR EVO HP R SYSVRF 400 AIR EVO HP R - 23

45/50 SYSVRF 450 AIR EVO HP R SYSVRF 450 AIR EVO HP R - 26

50/56 SYSVRF 500 AIR EVO HP R SYSVRF 500 AIR EVO HP R - 29

56/63 SYSVRF 560 AIR EVO HP R SYSVRF 560 AIR EVO HP R - 33

61,5/69 SYSVRF 615 AIR EVO HP R SYSVRF 615 AIR EVO HP R - 36

SYSVRF JOINT
67/75 SYSVRF 670 AIR EVO HP R SYSVRF 335 AIR EVO HP R x2 39
OUT 02 HP

SYSVRF 280 AIR EVO HP R SYSVRF JOINT


73/81,5 SYSVRF 730 AIR EVO HP R 43
+ SYSVRF 450 AIR EVO HP R OUT 02 HP

SYSVRF 280 AIR EVO HP R SYSVRF JOINT


78/87,5 SYSVRF 780 AIR EVO HP R 46
+ SYSVRF 500 AIR EVO HP R OUT 02 HP

SYSVRF 280 AIR EVO HP R SYSVRF JOINT


84/94,5 SYSVRF 840 AIR EVO HP R 50
+ SYSVRF 560 AIR EVO HP R OUT 02 HP

SYSVRF 280 AIR EVO HP R SYSVRF JOINT


89,5/100,5 SYSVRF 895 AIR EVO HP R 53
+ SYSVRF 615 AIR EVO HP R OUT 02 HP

SYSVRF 335 AIR EVO HP R SYSVRF JOINT


95/106 SYSVRF 950 AIR EVO HP R 56
+ SYSVRF 615 AIR EVO HP R OUT 02 HP

SYSVRF JOINT
100/112 SYSVRF 1000 AIR EVO HP R SYSVRF 500 AIR EVO HP R x2 59
OUT 02 HP

SYSVRF 450 AIR EVO HP R SYSVRF JOINT


106,5/119 SYSVRF 1065 AIR EVO HP R 63
+ SYSVRF 615 AIR EVO HP R OUT 02 HP

SYSVRF 500 AIR EVO HP R SYSVRF JOINT


111,5/125 SYSVRF 1115 AIR EVO HP R 64
+ SYSVRF 615 AIR EVO HP R OUT 02 HP

SYSVRF 560 AIR EVO HP R SYSVRF JOINT


117,5/132 SYSVRF 1175 AIR EVO HP R 64
+ SYSVRF 615 AIR EVO HP R OUT 02 HP

SYSVRF JOINT
123/138 SYSVRF 1230 AIR EVO HP R SYSVRF 615 AIR EVO HP R x2 64
OUT 02 HP
VRF Heat Pump combination | 19

Cooling/ Max.
Recommended Outdoor
Design Heating Model indoor
combination branch
capacity kW unit qty

SYSVRF 335 AIR EVO HP R x2 SYSVRF JOINT


128,5/144 SYSVRF 1285 AIR EVO HP R 64
+ SYSVRF 615 AIR EVO HP R OUT 03 HP

SYSVRF 280 AIR EVO HP R


SYSVRF JOINT
134,5/150,5 SYSVRF 1345 AIR EVO HP R + SYSVRF 450 AIR EVO HP R 64
OUT 03 HP
+ SYSVRF 615 AIR EVO HP R
SYSVRF 280 AIR EVO HP R
SYSVRF JOINT
139,5/156,5 SYSVRF 1395 AIR EVO HP R + SYSVRF 500 AIR EVO HP R 64
OUT 03 HP
+ SYSVRF 615 AIR EVO HP R
SYSVRF 280 AIR EVO HP R
SYSVRF JOINT
145,5/163,5 SYSVRF 1455 AIR EVO HP R + SYSVRF 560 AIR EVO HP R 64
OUT 03 HP
+ SYSVRF 615 AIR EVO HP R

SYSVRF 280 AIR EVO HP R + SYSVRF JOINT


151/169,5 SYSVRF 1510 AIR EVO HP R 64
SYSVRF 615 AIR EVO HP R x2 OUT 03 HP

SYSVRF 335 AIR EVO HP R + SYSVRF JOINT


156,5/175,5 SYSVRF 1565 AIR EVO HP R 64
SYSVRF 615 AIR EVO HP R x2 OUT 03 HP

SYSVRF 500 AIR EVO HP R x2 SYSVRF JOINT


161,5/181 SYSVRF 1615 AIR EVO HP R 64
+ SYSVRF 615 AIR EVO HP R OUT 03 HP

SYSVRF 450 AIR EVO HP R + SYSVRF JOINT


168/188 SYSVRF 1680 AIR EVO HP R 64
SYSVRF 615 AIR EVO HP R x2 OUT 03 HP

SYSVRF 500 AIR EVO HP R + SYSVRF JOINT


173/194 SYSVRF 1730 AIR EVO HP R 64
SYSVRF 615 AIR EVO HP R x2 OUT 03 HP

SYSVRF 560 AIR EVO HP R + SYSVRF JOINT


179/201 SYSVRF 1790 AIR EVO HP R 64
SYSVRF 615 AIR EVO HP R x2 OUT 03 HP

SYSVRF JOINT
184,5/207 SYSVRF 1845 AIR EVO HP R SYSVRF 615 AIR EVO HP R x3 64
OUT 03 HP

SYSVRF 335 AIR EVO HP R x 2 SYSVRF JOINT


190/213 SYSVRF 1900 AIR EVO HP R 64
+ SYSVRF 615 AIR EVO HP R x 2 OUT 04 HP

SYSVRF 280 AIR EVO HP R


SYSVRF JOINT
196/219,5 SYSVRF 1960 AIR EVO HP R + SYSVRF 450 AIR EVO HP R 64
OUT 04 HP
+ SYSVRF 615 AIR EVO HP R x 2
SYSVRF 280 AIR EVO HP R +
SYSVRF JOINT
201/219,5 SYSVRF 2010 AIR EVO HP R SYSVRF 500 AIR EVO HP R + 64
OUT 04 HP
SYSVRF 615 AIR EVO HP R x 2
SYSVRF 280 AIR EVO HP R +
SYSVRF JOINT
207/232,5 SYSVRF 2070 AIR EVO HP R SYSVRF 560 AIR EVO HP R + 64
OUT 04 HP
SYSVRF 615 AIR EVO HP R x 2

SYSVRF 280 AIR EVO HP R + SYSVRF JOINT


212,5/238,5 SYSVRF 2125 AIR EVO HP R 64
SYSVRF 615 AIR EVO HP R x 3 OUT 04 HP

SYSVRF 335 AIR EVO HP R + SYSVRF JOINT


218/244,5 SYSVRF 2180 AIR EVO HP R 64
SYSVRF 615 AIR EVO HP R x 3 OUT 04 HP

SYSVRF 500 AIR EVO HP R x 2 + SYSVRF JOINT


223/250 SYSVRF 2230 AIR EVO HP R 64
SYSVRF 615 AIR EVO HP R x 2 OUT 04 HP

SYSVRF 450 AIR EVO HP R + SYSVRF JOINT


229,5/257 SYSVRF 2295 AIR EVO HP R 64
SYSVRF 615 AIR EVO HP R x 3 OUT 04 HP

SYSVRF 500 AIR EVO HP R + SYSVRF JOINT


234,5/263 SYSVRF 2345 AIR EVO HP R 64
SYSVRF 615 AIR EVO HP R x 3 OUT 04 HP

SYSVRF 560 AIR EVO HP R + SYSVRF JOINT


240,5/270 SYSVRF 2405 AIR EVO HP R 64
SYSVRF 615 AIR EVO HP R x 3 OUT 04 HP

SYSVRF JOINT
246/276 SYSVRF 2460 AIR EVO HP R SYSVRF 615 AIR EVO HP R x 4 64
OUT 04 HP
20 | VRF Heat Recovery

Modular VRF Heat Recovery Outdoor Units


SYSVRF AIR EVO HR
Features
Simultaneous operation in cooling and heating mode
provides more comfort and reduces power consumption.
Wide application area due to incredible piping lenght
and wide operating temperature range.
 Free modular combination of 5 basic units, up to a total
capacity of maximum 180 kW.
Top class energy efficiency.
All DC Inverter Scroll compressors providing wide
capacity output from 10% to 100% evenly.
DC fan motor.
High performance of the new designed heat
exchanger with double refrigerant circuit.
External static pressure up to 40 Pa (20 Pa standard).
Maximum 64 indoor unit connection.
Indoor unit combination total capacity index from 50%
to 130%.
Centralized control, BMS connection and web access
potential.
Continuous heating output during defrost operation
thanks to the innovative double heat exchanger.
1250

Dimensions
SYSVRF 252/280/335/400/450 AIR EVO HR R
1615

1250
1615

765
765
VRF Heat Recovery | 21

Technical features
252 AIR EVO 280 AIR EVO 335 AIR EVO 400 AIR EVO 450 AIR EVO
Model Outdoor unit SYSVRF
HR R HR R HR R HR R HR R
Art. no. 314084 314085 314086 314087 314088
Power Supply V/Ph/Hz 380-415/3+N/50 or 60
Cooling capacity Nom/Eurovent kW 25,2 /25,2 28,0 / 28,0 33,5 / 33,5 40,0 / 40,0 45,0 / 45,0
Power Input Nom/Eurovent kW 5,73 / 5,97 6,67 / 6,75 8,07 / 9,28 11,30 / 11,5 13,24 / 14,2
EER Nom/Eurovent kW/ kW 4,40 / 4,42 4,20 / 4,15 4,15 / 3,61 3,54 / 3,48 3,40 / 3,17
SEER/SCOP 7,53 / 6,23 7,43 / 6,05 7,40 / 6,02 6,68 / 5,67 6,38 / 5,45
Heating capacity Nom/Eurovent kW 27,0 / 27,0 31,5 / 31,5 37,5 / 37,5 45 / 40 50 / 45
Power Input Nom/Eurovent kW 6,0 / 5,02 7,33 / 6,21 8,72 / 9,24 11,19 / 9,76 12,79 / 11,9
COP Nom/Eurovent kW/ kW 4,50 / 5,38 4,30 / 5,07 4,30 / 4,06 4,02 / 4,10 3,91 / 3,78
Max. current A 20,8 22,1 22,8 31,8 32,8
Quantity pcs 1 DC Inverter / Scroll 2 DC Inverter / Scroll
Compressor Start-up method Soft start
Refrigerant oil ml 500 2X500
Type/motor 2 Axial / DC motor
Fan Static pressure Pa 0-20 (0-40 factory option)
Air flow m3/h 12.000 12.000 13.000 15.000 15.000
Sound power level dB(A) 79 83 84 88 88
Sound pressure level dB(A) 57 57 58 60 60
Type/motor R410A
Refrigerant
Factory charge kg 10 10 10 13 13
Dimension (LxWxH) mm 1.250x765x1.615 1.250x765x1.615
Packing (LxWxH) mm 1.305x825x1.790 1.350x825x1.790
Net/gross weight kg 255/273 303/322
Liquid pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Low pressure gas pipe mm (in) 22,2 (7/8”) 25,4 (1”) 28,6 (1 1/8”)
Piping dimension High pressure gas pipe mm (in) 19,1 (3/4”) 22,2 (7/8”)
Oil balance pipe mm (in) 6,35 (1/4”)
Gas balance pipe mm (in) 19,1 (3/4")
Max quantity indoor units connection pcs 13 16 20 23 26
Operating ambient temp. range °C Cooling -5...+48 / Heating -20...+24 / Simultaneous Cooling and Heating -5...+24
Eurovent data are defined for combination ratio equals to 100% and for Duct indoor units.

Operating conditions
Indoor unit Outdoor unit Piping lenght Level difference
Cooling mode 27°C DB, 19°C WB 35°C DB,24°C WB 7,5 m 0m
Heating mode 20°C DB, 15°C WB 7°C 7,5 m 0m

The sound pressure value may vary depending on ambient conditions.

Piping Lenght

Maximum piping equivalent lenght.

Maximum piping (the farthest IDU from the first indoor unit
branch) equivalent lenght.

Maximum outdoor unit-indoor unit drop height.

Maximum indoor unit to indoor unit drop height.

Outdoor units SYSVRF 252 to 1800 AIR EVO HR R Permitted value


Total piping lenght (actual) 1.000 m
Actual lenght 175 m
Maximum piping
Piping lenght Aquivavent lenght 200 m
Piping (the farthest IDU from the first indoor unit branch)
40 m/90 m*
equivalent lenght

Outdoor unit-indoor Outdoor unit up 110 m


Drop height unit drop height Outdoor unit down 70 m
Indoor unit to indoor unit drop height 30 m

* When the farthest pipe length is more than 40m, it needs to meet specific conditions according to the installation part of the technical manual.
22 | VRF Heat Recovery switch module

Mode Switch module


for VRF Heat Recovery systems
SYSVRF BOX HR
Features SYSVRF BOX 02 HR SYSVRF BOX 06 HR

Simultaneous heating and cooling in a single refrigerant


system thanks to the combination of SYSVRF HR
outdoor units and the SYSVRF BOX modules.
SYSVRF BOX HR is available in 3 different modules with
2, 4 or 6 outlets and combination up to 24 indoor units
from a single module. SYSVRF BOX 04 HR
 Compact and light design, it can be installed in narrow
space.
Independent sub-cooling circuit for each SYSVRF BOX
HR module.

Heating Heating Heating Off Cooling Cooling

Dimensions SYSVRF BOX

SYSVRF BOX SYSVRF BOX SYSVRF BOX


02 HR 04 HR 06 HR
A 630 960 960
B 600 600 600
C 225 225 225
D 490 820 820
E 300 300 300
VRF Heat Recovery switch module | 23

Technical features
SYSVRF BOX SYSVRF BOX SYSVRF BOX
Model
02 HR 04 HR 06 HR
Art. no. 314161 314162 314186
Power Supply V/Ph/Hz 220-240/1/50 or 60
Max indoor unit groups 2 4 6
Max number of each group indoor units 4 4 4
Max number of all downstream indoor units 4x2=8 4x4=16 4x6=24
Max capacity of each group indoor units kW 16 16 16
Total capacity of all downstream indoor units kW <28 <45 <45
Liquid pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) 15,9 (5/8”)
Connect to outdoor unit High pressureg gas pipe mm (in) 19,1 (3/4”) 22,2 (7/8”) 22,2 (7/8”)
Piping connections Low pressure gas pipe mm (in) 25,4 (1”) 31,8 (1 1/4”) 31,8 (1 1/4”)
Liquid pipe mm (in) 9,5 (3/8”) 9,5 (3/8”) 9,5 (3/8”)
Connect to indoor unit
Gas pipe mm (in) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”)
Dimension (LxWxH) mm 630x225x600 960x225x600 960x225x600
Packing (LxWxH) mm 725x325x685 1.055x325x685 1.055x325x685
Net/gross weight kg 19,5/27 31/40 35/44,5

SYSVRF BOX SYSVRF BOX


Model
02-1 HR 04-1 HR
Art. no. 313550 313551
Power Supply V/Ph/Hz 220-240/1/50 or 60
Max number of indoor unit 1 1
Max capacity of indoor unit kW 20-28 40-56
Liquid pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Connect to outdoor unit High pressure gas pipe mm (in) 19,1 (3/4”) 22,2 (5/8”)
Piping
Low pressure gas pipe mm (in) 25,4 (1”) 31,8 (1 1/4”)
connections
Liquid pipe mm (in) 9,5 (3/8”) 9,5 (3/8”)
Connect to indoor unit
Gas pipe mm (in) 15,9 (5/8”) 15,9 (5/8”)
Dimension (LxWxH) mm 630x225x600 960x225x600
Packing (LxWxH) mm 725x325x685 1.055x325x685
Net/gross weight kg 19,5/27 31/40

Piping connections SYSVRF BOX

SYSVRF BOX 02 HR SYSVRF BOX 04 HR SYSVRF BOX 06 HR

Liquid pipe 12,7 (1/2”) 15,9 (5/8”) 15,9 (5/8”)


Outdoor unit High pressure pipe 19,1 (3/4”) 22,2 (7/8”) 22,2 (7/8”)
Low pressure pipe 25,4 (1”) 31,8 (1 1/4”) 31,8 (1 1/4”)
Liquid pipe 9,5 (3/8”) 9,5 (3/8”) 9,5 (3/8”)
Indoor unit
Gas pipe 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”)
24 | VRF Heat Recovery combination

Outdoor unit combination SYSVRF AIR EVO HR


Cooling/ Max.
Recommended Outdoor
Design Heating Model indoor
combination branch
capacity kW unit qty

25,2/27 SYSVRF 252 AIR EVO HR R SYSVRF 252 AIR EVO HR R - 13

28/31,5 SYSVRF 280 AIR EVO HR R SYSVRF 280 AIR EVO HR R - 16

33,5/37,5 SYSVRF 335 AIR EVO HR R SYSVRF 335 AIR EVO HR R - 20

40/45 SYSVRF 400 AIR EVO HR R SYSVRF 400 AIR EVO HR R - 23

45/50 SYSVRF 450 AIR EVO HR R SYSVRF 450 AIR EVO HR R - 26

SYSVRF 252 AIR EVO HR R SYSVRF JOINT


53,2/58,5 SYSVRF 532 AIR EVO HR R 29
+ SYSVRF 280 AIR EVO HR R OUT 02 HR

SYSVRF JOINT
56/63 SYSVRF 560 AIR EVO HR R SYSVRF 280 AIR EVO HR R x2 33
OUT 02 HR

SYSVRF 280 AIR EVO HR R SYSVRF JOINT


61,5/69 SYSVRF 615 AIR EVO HR R 36
+ SYSVRF 335 AIR EVO HR R OUT 02 HR

SYSVRF 280 AIR EVO HR R SYSVRF JOINT


68/76,5 SYSVRF 680 AIR EVO HR R 39
+ SYSVRF 400 AIR EVO HR R OUT 02 HR

SYSVRF 280 AIR EVO HR R SYSVRF JOINT


73/81,5 SYSVRF 730 AIR EVO HR R 43
+ SYSVRF 450 AIR EVO HR R OUT 02 HR

SYSVRF JOINT
80/90 SYSVRF 800 AIR EVO HR R SYSVRF 400 AIR EVO HR R x2 46
OUT 02 HR

SYSVRF 400 AIR EVO HR R SYSVRF JOINT


85/95 SYSVRF 850 AIR EVO HR R 50
+ SYSVRF 450 AIR EVO HR R OUT 02 HR

SYSVRF JOINT
90/100 SYSVRF 900 AIR EVO HR R SYSVRF 450 AIR EVO HR R x2 53
OUT 02 HR
VRF Heat Recovery combination | 25

Cooling/ Max.
Recommended Outdoor
Design Heating Model indoor
combination branch
capacity kW unit qty

SYSVRF 280 AIR EVO HR R x2 SYSVRF JOINT


96/108 SYSVRF 960 AIR EVO HR R 56
+ SYSVRF 400 AIR EVO HR R OUT 03 HR

SYSVRF 280 AIR EVO HR R x2 SYSVRF JOINT


101/113 SYSVRF 1010 AIR EVO HR R 59
+ SYSVRF 450 AIR EVO HR R OUT 03 HR

SYSVRF 280 AIR EVO HR R


SYSVRF JOINT
106,5/119 SYSVRF 1065 AIR EVO HR R + SYSVRF 335 AIR EVO HR R 63
OUT 03 HR
+ SYSVRF 450 AIR EVO HR R
SYSVRF 280 AIR EVO HR R
SYSVRF JOINT
113/126,5 SYSVRF 1130 AIR EVO HR R + SYSVRF 400 AIR EVO HR R 64
OUT 03 HR
+ SYSVRF 450 AIR EVO HR R

SYSVRF JOINT
120/135 SYSVRF 1200 AIR EVO HR R SYSVRF 400 AIR EVO HR R x3 64
OUT 03 HR

SYSVRF 400 AIR EVO HR R x2 SYSVRF JOINT


125/140 SYSVRF 1250 AIR EVO HR R 64
+ SYSVRF 450 AIR EVO HR R OUT 03 HR

SYSVRF 400 AIR EVO HR R + SYSVRF JOINT


130/145 SYSVRF 1300 AIR EVO HR R 64
SYSVRF 450 AIR EVO HR R x2 OUT 03 HR

SYSVRF JOINT
135/150 SYSVRF 1350 AIR EVO HR R SYSVRF 450 AIR EVO HR R x3 64
OUT 03 HR

SYSVRF 252 AIR EVO HR R+


SYSVRF JOINT
143,2/158,5 SYSVRF 1432 AIR EVO HR R SYSVRF 280 AIR EVO HR R + 64
OUT 04 HR
SYSVRF 450 AIR EVO HR R x2

SYSVRF 280 AIR EVO HR R x2 SYSVRF JOINT


146/163 SYSVRF 1460 AIR EVO HR R 64
+ SYSVRF 450 AIR EVO HR R x2 OUT 04 HR

SYSVRF 280 AIR EVO HR R +


SYSVRF JOINT
151,5/169 SYSVRF 1515 AIR EVO HR R SYSVRF 335 AIR EVO HR R + 64
OUT 04 HR
SYSVRF 450 AIR EVO HR R x2
SYSVRF 280 AIR EVO HR R +
SYSVRF JOINT
158/176,5 SYSVRF 1580 AIR EVO HR R SYSVRF 400 AIR EVO HR R + 64
OUT 04 HR
SYSVRF 450 AIR EVO HR R x2

SYSVRF 400 AIR EVO HR R x3 SYSVRF JOINT


165/185 SYSVRF 1650 AIR EVO HR R 64
+ SYSVRF 450 AIR EVO HR R OUT 04 HR

SYSVRF 400 AIR EVO HR R x2 SYSVRF JOINT


170/190 SYSVRF 1700 AIR EVO HR R 64
+ SYSVRF 450 AIR EVO HR R x2 OUT 04 HR

SYSVRF 400 AIR EVO HR R + SYSVRF JOINT


175/195 SYSVRF 1750 AIR EVO HR R 64
SYSVRF 450 AIR EVO HR R x3 OUT 04 HR

SYSVRF JOINT
180/200 SYSVRF 1800 AIR EVO HR R SYSVRF 450 AIR EVO HR R x4 64
OUT 04 HR
26 | VRF Heat Pump water-cooled

Modular VRF Heat Pump Units


SYSVRF WATER EVO HP
Features
Water-cooled VRF with DC Inverter compressor
and pipe-in-pipe heat exchanger.
 Compact size and long piping system.
High efficiency at partial load.
Inverter Scroll compressor providing wide capacity
output from 10% to 100% evenly.
Centralized control, BMS connection and web access
potential.
Pipe-in-pipe heat exchanger assures excellent
performance in heat trasfer and outstanding reliability.
Piping connection in four different directions makes
simple the installation of outdoor unit.
Maximum 59 indoor units connection (100 kW modules).
Indoor unit combination total capacity index from 50%
to 130%.

Dimensions

780
550
1000

52
176.5

55
152
45

32
198

95

112 70 64
61.5

50
620
20

52 444 52 326.5
30
VRF Heat Pump water-cooled | 27

Technical features

Model Outdoor unit SYSVRF 252 WATER EVO HP R 280 WATER EVO HP R 335 WATER EVO HP R
Art. no. 314247 314248 314249
Power Supply V/Ph/Hz 380-415/3+N/50
Cooling capacity kW 25,2 28,0 33,5
Power Input kW 4,80 6,10 8,00
EER 5,25 4,59 4,19
Heating capacity kW 27,0 31,5 37,5
Power Input kW 4,45 5,83 7,80
COP 6,07 5,40 4,81
Quantity pcs 1
Compressor
Crankcase heater W 40-80 40-80 40-80
Inverter Scroll
Refrigerant oil ml 500 500 500
Water flow m3/h 5,4 6,0 7,2
Pressure drop kPa 35 40 48
Sound pressure level dB(A) 51 52 52
Type R410A
Refrigerant
Refrigerant charge kg 2,0 2,0 2,0
Dimension LxWxH mm 780x1.000x550
Packing LxWxH mm 845x1.170x600
Net/gross weight kg 146/155 140/155 147/156
Liquid pipe mm (in) 9,53 (3/8”) 9,53 (3/8”) 12,7 (1/2”)
Gas pipe mm (in) 22,2 (7/8”) 22,2 (7/8”) 25,4 (1”)
Piping dimension
Oil balance pipe mm (in) 6,35 (1/4”)
Water side pipe mm 31,8
Max qty. indoor units connection pcs 13 16 20

Operating conditions

Indoor unit Module water inlet Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 30°C DB 5m 0m
Heating mode 20°C DB, 15°C WB 20°C DB 5m 0m

The sound pressure value may vary depending on ambient conditions.

Piping Lenght

Maximum piping equivalent lenght.


100 m
Maximum piping (the farthest IDU from the first indoor unit
branch) equivalent lenght.

Maximum outdoor unit-indoor unit drop height.


30 m 8m

Maximum indoor unit to indoor unit drop height. 20 m

Modules SYSVRF WATER EVO HP Permitted value


Total piping lenght (actual) 300 m
Actual lenght 120 m
Maximum piping
Piping lenght Equivavent lenght 150 m
Piping (the farthest IDU from the first indoor unit branch)
40 m
equivalent lenght
Module up 50 m
Module indoor unit drop height
Drop height Module down 40 m
Indoor unit to indoor unit drop height 30 m
28 | VRF water-cooled combination

Unit combination SYSVRF WATER EVO HP


Cooling/ Max.
Recommended Outdoor
Design Heating Model indoor
combination branch
capacity kW unit qty

SYSVRF 252 WATER EVO


25,2/27 SYSVRF 252 WATER EVO HP R - 13
HP R

SYSVRF 280 WATER EVO


28/31,5 SYSVRF 280 WATER EVO HP R - 16
HP R

SYSVRF 335 WATER EVO


33,5/37,5 SYSVRF 335 WATER EVO HP R - 20
HP R

SYSVRF 504 WATER EVO SYSVRF JOINT


50,4/54 SYSVRF 252 WATER EVO HP R x2 26
HP R OUT 02 HP

SYSVRF 532 WATER EVO SYSVRF 252 WATER EVO HP R SYSVRF JOINT
53,2/58,5 29
HP R + SYSVRF 280 WATER EVO HP R OUT 02 HP

SYSVRF 560 WATER EVO SYSVRF JOINT


56/63 SYSVRF 280 WATER EVO HP R x2 33
HP R OUT 02 HP

SYSVRF 615 WATER EVO SYSVRF 280 WATER EVO HP R SYSVRF JOINT
61,5/69 36
HP R + SYSVRF 335 WATER EVO HP R OUT 02 HP

SYSVRF 670 WATER EVO SYSVRF JOINT


67/75 SYSVRF 335 WATER EVO HP R x2 39
HP R OUT 02 HP
VRF water-cooled combination | 29

Cooling/ Max.
Recommended Outdoor
Design Heating Model indoor
combination branch
capacity kW unit qty

SYSVRF 784 WATER EVO SYSVRF 232 WATER EVO HP R x2 SYSVRF JOINT
78,4/85,5 43
HP R + SYSVRF 280 WATER EVO HR R OUT 03 HP

SYSVRF 252 WATER EVO HP R


SYSVRF 812 WATER EVO SYSVRF JOINT
81,2/90 + SYSVRF 280 WATER EVO HP 46
HP R OUT 03 HP
R x2

SYSVRF 840 WATER EVO SYSVRF JOINT


84/94,5 SYSVRF 280 WATER EVO HP R x3 50
HP R OUT 03 HP

SYSVRF 895 WATER EVO SYSVRF 280 WATER EVO HP R x2 SYSVRF JOINT
89,5/100,5 53
HP R + SYSVRF 335 WATER EVO HP R OUT 03 HP

SYSVRF 950 WATER EVO SYSVRF 280 WATER EVO HP R + SYSVRF JOINT
95/106,5 56
HP R SYSVRF 335 WATER EVO HP R x2 OUT 03 HP

SYSVRF 1005 WATER EVO SYSVRF JOINT


100,5/112,5 SYSVRF 335 WATER EVO HP R x3 59
HP R OUT 03 HP
30 | VRF Wall indoor units

Wall-Mounted Indoor Units


SYSVRF WALL
Features
Front panel of modern design that fits into any
interior decor.
All models are equipped with high efficient DC fan
motor.
Even and smooth air distribution due to auto swing
function.
Multi-refrigerant outlet pipe method: left/right/rear,
more flexible for installation.
Washable air filter, easy for insertion and removal.
Built-in electronic expansion valve (EXV) ensuring
precise flow control. Infrared remote Wired
control controller
Infrared receiver and remote SYS RM 02 SYS RM 02 SYS WC 29
with address setting function as standard equipment. (standard) Art. no. 314772
(optional)
Power supply 50Hz or 60Hz.

280
Accessories/option Wired
controller
Wired controller SYS WC 29 with address
54

50
SYS WC 120
9

Art. no. 314774


setting function for heat pump system. 203
(optional)
835

Wired controller SYS WC 120 for heat


recovery system.
315
60

45
15

Dimensions 223 990

SYSVRF WALL 22/28 Q SYSVRF WALL 71/80 Q


280

343
54

50
9

64
280

203 835
56
12

262 1194
54

50
9

SYSVRF
203
WALL 36/45/56 Q 835
315
60

45
15

315

223 990
60

45
15

223 990
343
64

56
12

343

262 1194
64
VRF Wall indoor units | 31

Technical features

Model Indoor unit SYSVRF WALL 22 Q WALL 28 Q WALL 36 Q WALL 45 Q WALL 56 Q WALL 71 Q WALL 80 Q
Art. no. 314767 314768 314769 314770 314771 314785 314786
Power Supply V/Ph/Hz 220-240/1/50 or 60
Cooling capacity kW 2,2 2,8 3,6 4,5 5,6 7,1 8,0
Power input kW 8 9 19 19 27 49 53
Current 0,27 0,31 0,43 0,44 0,58 0,60 0,60
Heating capacity kW 2,4 3,2 4,0 5,0 6,3 8,0 9,0
Power input kW 8 9 19 19 27 49 53
Current 0,27 0,31 0,43 0,44 0,58 0,60 0,60
Indoor fan motor DC motor DC motor
Air flow (H/M/L) m3/h 420/390/360 420/370/320 660/570/490 590/510/420 750/650/550 1.200/1.000/810
Sound pressure level (H/M/L) dB(A) 31/30/29 31/30/29 33/32/30 35/33/31 38/36/34 44/39/36
Dimension LxWxH mm 835x203x280 990x223x315 1.194x262x343
Packing LxWxH mm 935x320x385 1.085x335x420 1.290x375x460
Net/gross weight kg 8,4/12,1 9,5/13,1 11,4/15,5 12,8/16,9 12,8/16,9 17,0/22,4
Refrigerant R410A R410A
Liquid pipe mm (in) 6,4 (1/4") 9,5 (3/8")
Piping dimension
Gas pipe mm (in) 12,7 (1/2") 15,9 (5/8")
Drain piping mm 16,5 16,5
Operating ambient temp. range °C Cooling +17 … +32 / Heating +10 … +28

Operating conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m
Heating mode 20°C DB, 15°C WB 7°C 8m 0m

The sound pressure value may vary depending on ambient conditions.


32 | VRF Compact Cassette indoor units

Compact Cassette Indoor Units


SYSVRF CASSETTE MINI
Features
New grille SYSPANEL CASSETTE MINI VRF with 360°
air discharge providing strong circulating air flow
to cool or heat every corner of the room.
 Compact casing making it match perfectly with
ambient decoration.
Advanced 3D spiral fan design reducing the air
resistance and operation noise.
All models are equipped with high efficient DC fan
motor.
Integrated drain pump with a head of 500 mm.
Fresh air hole and reserved ports for duct connection. Connecting points of refrigerant pipe (gas/liquid side)
Built-in electronic expansion valve (EXV) ensuring Drain point

precise flow control. Infrared remote Wired


60

control controller
Infrared receiver and remote SYS RM 02 SYS RM 02 SYS WC 29
with address setting function as standard equipment. (standard) Art. no. 314772
(optional)
Power supply 50Hz or 60Hz.

647 (panel)
523
570
Accessories/option Wired
controller
Wired controller SYS WC 29 with address SYS WC 120
setting function for heat pump system. Art. no. 314774
(optional)
Wired controller SYS WC 120 for heat
recovery system.
545
Dimensions 570

647 (panel)
Connecting points of refrigerant pipe (gas/liquid side)
Drain point
60

Hook
Main body
647 (panel)
523
570

Nut
260

50
Ceiling 600 Panel
545
570

647 (panel)
VRF Compact Cassette indoor units | 33

Technical features

CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE


Model Indoor unit SYSVRF
MINI 15 Q MINI 22 Q MINI 28 Q MINI 36 Q MINI 45 Q MINI 56 Q
CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE
Model Panel unit SYSPANEL
MINI VRF MINI VRF MINI VRF MINI VRF MINI VRF MINI VRF
Art. no. Indoor unit 314779 314751 314752 314753 314754 314755
Art. no. Panel unit 313324 313324 313324 313324 313324 313324
Power Supply V/Ph/Hz 220-240/1/50 or 60
Cooling capacity kW 1,5 2,2 2,8 3,6 4,5 5,6
Power Input W 14 15 16 21
Current A 0,23 0,26 0,28
Indoor fan motor DC motor
Heating capacity kW 1,7 2,4 3,2 4,0 5,0 6,0
Power Input W 11 13 18
Current A 0,23 0,26 0,28
Air flow (H/M/L) m3/h 526/449/364 576/503/405 604/516/400
Sound pressure level (H/M/L) dB(A) 34/33/22 35/32/22 35/32/22 41,5/35,6/28,8
Dimension (LxWxH) mm 570x570x260
Unit Packing (LxWxH) mm 675x675x285
Net/gross weight kg 16/22 17,5/23,5
Dimension (LxWxH) mm 647x647x50
Panel Packing (LxWxH) mm 715x715x113
Net/gross weight kg 3/5
Refrigerant R410A
Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3,8”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm 25
Operating ambient temp. range °C Cooling +17...+32 / Heating +10...+28

Operating conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m
Heating mode 20°C DB, 15°C WB 7°C 8m 0m

The sound pressure value may vary depending on ambient conditions.


34 | VRF Cassette indoor units

Standard Cassette Indoor Units


SYSVRF CASSETTE
Features
New grille SYSPANEL CASSETTE EVO with 360° air
discharge providing strong circulating air flow to cool
or heat every corner of the room.
 Ultra-thin casing for easy installation into a shallow
ceiling.
Advanced 3D spiral fan design reducing the air
resistance and operation noise.
All models are equipped with high efficient
DC fan motor.
Integrated drain pump with a head of 750 mm.
Fresh air hole and reserved ports for duct connection.
Built-in electronic expansion valve (EXV) ensuring
precise flow control.
Infrared receiver and remote SYS RM 02
with address setting function as standard equipment. Infrared remote Wired
control controller
Power supply 50Hz or 60Hz. SYS RM 02 SYS WC 29
(standard) Art. no. 314772
(optional)
Accessories/option
Wired controller SYS WC 29 with address
950
Wired
setting function for heat pump system. controller
780 105 Φ
A ou
Wired controller SYS WC 120 for heat SYS WC 120
recovery system. Art. no. 314774
(optional)

55
950
680

840

Dimensions

950
780 105 Φ32 Drain pipe B
A outter diameter 70 Φ75 New air
supply orifice

≥20
55
950
680

840

146

Ceiling 46
Panel
Main body
B 840
Φ75 New air
supply orifice 904

CASSETTE CASSETTE
≥20 CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE
Indoor unit SYSVRF
28 Q 36 Q 45 Q 56 Q 71 Q 90 Q 112 Q 140 Q
A mm 230 230 300
B mm 170 170 190
146

Ceiling 46
Panel
Main body
VRF Cassette indoor units | 35

Technical features

CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE


Model Indoor unit SYSVRF
28 Q 36 Q 45 Q 56 Q 71 Q 90 Q 112 Q 140 Q
CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE
Model Panel unit SYSPANEL
EVO VRF EVO VRF EVO VRF EVO VRF EVO VRF EVO VRF EVO VRF EVO VRF
Art. no. Indoor unit 314756 314757 314758 314759 314760 314255 314256 314257
Art. no. Panel unit 313728 313728 313728 313728 313728 313728 313728 313728
Power Supply V/Ph/Hz 220-240/1/50 or 60
Cooling capacity kW 2,8 3,6 4,5 5,6 7,1 9,0 11,2 14,0
Power Input W 25 31 46 75 94
Current A 0,32 0,34 0,36 0,82 0,98
Indoor fan motor DC motor
Heating capacity kW 3,2 4,0 5,0 6,3 8,0 10,0 12,5 15,0
Power Input W 25 31 46 75 94
Current A 0,32 0,34 0,36 0,82 0,98

1200/996/ 1727/1426/
Air flow (H/M/L) m3/h 982/832/677 1029/857/704 1596/1239/1034
748 1224
Sound pressure level (H/M/L) dB(A) 42/37/32 43/38/34 45/39/34 47/41/36 50/45/35
Dimension (LxWxH) mm 840x840x230 840x840x300
Unit Packing (LxWxH) mm 955x955x247 955x955x317
Net/gross weight kg 24/28 26/30 32/37
Dimension (LxWxH) mm 950x950x46
Panel Packing (LxWxH) mm 1.000x1.000x60
Net/gross weight kg 6/8
Refrigerant R410A
Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3/8”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm 32
Operating ambient temp. range °C Cooling +17...+32 / Heating +10...+28

Operating conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m
Heating mode 20°C DB, 15°C WB 7°C 8m 0m

The sound pressure value may vary depending on ambient conditions.


36 | VRF Cassette 1way indoor units

Cassette 1Way Indoor Unit


SYSVRF CASSETTE 1W
Features
Stylish look with new decorative panel.
 Ultra-thin chassis for easy installation in false ceiling.
Integrated drain pump with a head of 750mm.
Built-in electronic expansion valve (EXV) ensuring
precise flow control.
Infrared receiver and remote controller SYS RM 02.
With address setting function as standard equipment.
Power supply 50Hz.

Infrared remote Wired


Accessories/option control controller
SYS RM 02 SYS WC 29
Wired controller SYS WC 29 with address
(standard) Art. no. 314772
setting function for heat pump system. (optional)
Wired controller SYS WC 120 for heat
recovery system.
Wired
controller
SYS WC 120
Art. no. 314774
(optional)

Dimensions

1015
290
VRF Cassette 1way indoor units | 37

Technical features

CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE


Model Indoor unit SYSVRF
1W 18 Q 1W 22 Q 1W 28 Q 1W 36 Q 1W 45 Q 1W 56 Q 1W 71 Q
CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE
Model Panel unit SYSPANEL
1W VRF 1W VRF 1W VRF 1W VRF 1W VRF L 1W VRF L 1W VRF L
Art. no. Indoor unit 314213 314214 314215 314216 314780 314781 314782
Art. no. Panel unit 314217 314783
Power Supply V/Ph/Hz 220-240/1/50
Cooling capacity kW 1,8 2,2 2,8 3,6 4,5 5,6 7,1
Power Input W 41 48 48 60
Current A 0,24 0,25 0,27 0,32 0,36
Heating capacity kW 2,2 2,6 3,2 4,0 5,0 6,3 8,0
Power Input W 41 43 44 55
Current A 0,24 0,25 0,27 0,32 0,36
Indoor fan motor AC motor
Air flow (H/M/L) m3/h 523/404/275 573/456/315 693/600/476 792/688/549 933/749/592
Sound pressure level (H/M/L) dB(A) 37/34/30 38/34/30 39/37/34 40/38/34 41/39/35 42/40/36 44/41/37
Dimension (LxWxH) mm 1.054×425×153 1.204x443x189
Unit Packing (LxWxH) mm 1.155x490x245 1.370x505x295
Net/gross weight kg 12,5/16 13/16,5 18,5/23,2 18,8/23,5/19,5/24,2
Dimension (LxWxH) mm 1.180x465x25 1.350x505x25
Panel Packing (LxWxH) mm 1.232×517×107 1410x560x95
Net/gross weight kg 3,5/5,2 3,5/5,2 4/5,4 4/5,4
Refrigerant R410A
Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3/8”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm 25
Operating ambient temp. range °C Cooling +17...+32 / Heating +10...+28

Operating conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m
Heating mode 20°C DB, 15°C WB 7°C 8m 0m

The sound pressure value may vary depending on ambient conditions.


38 | VRF Cassette 2way indoor units

Cassette 2Way Indoor Unit


SYSVRF CASSETTE 2W
Features
Stylish look with new decorative panel.
 Slim casing for easy installation in narrow ceiling.
Integrated drain pump with a head of 750mm.
Built-in electronic expansion valve (EXV) ensuring
precise flow control.
Infrared receiver and remote controller SYS RM 02.
With address setting function as standard equipment.
Power supply 50Hz.

Accessories/option Infrared remote Wired controller


control SYS WC 29
Wired controller SYS WC 29 with address SYS RM 02 Art. no. 314772
(standard) (optional)
setting function for heat pump system.
Wired controller SYS WC 120 for heat
recovery system.
Wired controller
SYS WC 120
Art. no. 314774
(optional)

Dimensions
591
436
57 1172 241
701 129 129 185 44
Fresh air 257
connector 120 104 91
Φ 32

44

51
91
117

171

Φ160
176
192

45
151

299
299
5
12
Φ

Φ 32

42~45

680
1430

The panel contour dimension 1430


20 The ceiling opening dimension 1390 20
Hanging screw bolts distance 1207
The ceiling opening (1390*640)
Machine body size 1172
20
The ceiling opening

bolts distance 520


The panel contour

dimension 640
dimension 680

Hanging screw
Machine body
size 591

151

701 129
20

44
VRF Cassette 2way indoor units | 39

Technical features

CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE


Model Indoor unit SYSVRF
2W 22 Q 2W 28 Q 2W 36 Q 2W 45 Q 2W 56 Q
CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE
Model Panel unit SYSPANEL
2W VRF 2W VRF 2W VRF 2W VRF 2W VRF
Art. no. Indoor unit 314218 314219 314220 314221 314222
Art. no. Panel unit 314224
Power Supply V/Ph/Hz 220-240/1/50
Cooling capacity kW 2,2 2,8 3,6 4,5 5,6
Power Input W 57 60 92 108
Current A 0,35 0,45 0,55
Heating capacity kW 2,6 3,2 4,0 5,0 6,3
Power Input W 57 60 92 108
Current A 0,35 0,45 0,55
Indoor fan motor AC motor
Air flow (H/M/L) m3/h 654/530/410 725/591/458 850/670/550 980/800/670
Sound pressure level (H/M/L) dB(A) 33/29/24 36/32/29 39/35/30
Dimension (LxWxH) mm 1.172×591×299
Unit Packing (LxWxH) mm 1.355×675×400
Net/gross weight kg 34/42,5 36/44,5
Dimension (LxWxH) mm 1.430x680x53
Panel Packing (LxWxH) mm 1.525x765x130
Net/gross weight kg 10,5/15
Refrigerant R410A
Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3/8”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm 32
Operating ambient temp. range °C Cooling +17...+32 / Heating +10...+28

Operating conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m
Heating mode 20°C DB, 15°C WB 7°C 8m 0m

The sound pressure value may vary depending on ambient conditions.


40 | VRF Ceiling/Floor indoor units

Ceiling and Floor Indoor Units


SYSVRF CEILING
Features
Flexible vertical or horizontal installation, even into a 995

corner of the ceiling. 906,5


35
Infrared remote
control
198,2
 Even and smooth air distribution due to auto horizontal 401 371
39,5

SYS RM 02
and auto vertical swing function.

133,5
(standard)

98

175
Models 90,112 and 140 equipped with high efficient

207

200
DC fan motor.

655
Wide angle air flow. Wired
Low noise operation. controller
SYS WC 29
Washable air filter, easy for insertion and removal.
Art. no. 314772
Built-in electronic expansion valve (EXV) ensuring (optional)

precise flow control.


Infrared receiver and remote SYS RM 02 Wired
with address setting function as standard equipment. controller
1284,5
SYS WC 120
Power supply 50Hz or 60Hz (only 90, 112 and 140). 1194,5
547 515 Art.198,2
no. 314774
39,5
37 (optional)
Accessories/option
133,5
98

175

Wired controller SYS WC 29 with address


200

recovery system.
655

setting function for heat pump system.


Wired controller SYS WC 120 for heat
Dimensions
SYSVRF CEILING 36/45/56/71
995 Q SYSVRF CEILING 112/140 Q
906,5

995 35
198,2
39,5
401 906,5 371 1670
35 1542,3
198,2
133,5
98

39,5 724,5 630,5


175

235
401 371 112,5
69,5
207

133,5
98

175

144
184,5
200

255,2
655
207

200

655

675

SYSVRF CEILING 90 Q

1284,5
1194,5
547 515
198,2
1284,5 39,5
1194,5 37
547 515
133,5
98

198,2
175

39,5
37
133,5
98

200
175
655
200
655

1670
1542,3
724,5 630,5
VRF Ceiling/Floor indoor units | 41

Technical features

CEILING CEILING CEILING CEILING CEILING CEILING CEILING


Model Indoor unit SYSVRF
36 Q 45 Q 56 Q 71 Q 90 Q 112 Q 140 Q
Art. no. 314116 314117 314118 314119 314282 314283 314284
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 or 60
Cooling capacity kW 3,6 4,5 5,6 7,1 9,0 11,2 14,0
Power Input W 49 120 122 125 126 65x2
Current A 0,55 0,57 0,60 0,83
Heating capacity kW 4,0 5,0 6,3 8,0 10,0 12,5 15,5
Power Input W 49 120 122 125 126 65x2
Current A 0,55 0,57 0,60 0,83
Indoor fan motor AC motor DC motor
650/ 1.200/
Air flow (H/M/L) m3/h 800/600/500 1.980/1.860/1.730
570/500 900/700
Sound pressure level (H/M/L) dB(A) 40/38/36 43/41/38 45/43/40 47/45/42
1.280x
Dimension (LxWxH) mm 990x206x660 1.670x244x680
206x660

1.379x
Packing (LxWxH) mm 1.089x296x744 1.764x329x760
296x744
Net/gross weight kg 26/32 28/34 34,5/41 54/59
Refrigerant R410A
Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3/8”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm 16
Operating ambient temp. range °C Cooling +17...+32 / Heating +10...+28

Operating conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m
Heating mode 20°C DB, 15°C WB 7°C 8m 0m

The sound pressure value may vary depending on ambient conditions.


42 | VRF Duct indoor units

Medium Static Pressure Duct Indoor Units


SYSVRF DUCT
Features
External static pressure up to 100 Pa.
All models are equipped with high efficient
DC fan motor.
 Washable air filter placed in an aluminum frame which
is removable downward from the bottom.
Fresh air hole, air inlet/outlet flange are standard for
easy duct connection.
Air inlet from back as standard and from bottom as
optional with the same flange plate.
Wired Infrared
Integrated drain pump with a head of 750 mm. controller remote control
SYS WC 29 SYS RM 02
Electronic expansion valve (EXV) fixed inside of the
(standard) (standard)
indoor unit.
Std functional port such as remote on/off free contact.
Display board with infrared receiver as standard
Wired
equipment. controller
SYS WC 120
Unit available with wired controller SYS WC 29 or with
Art. no. 314774
infrared controller SYS RM 02 (optional)
Power supply 50Hz or 60Hz.

Accessories/option
Wired controller SYS WC 120 for heat
recovery system.

Dimensions Indoor unit DUCT DUCT DUCT DUCT DUCT


SYSVRF 15/22 Q 28 Q 36 Q 45 Q 56 Q
A mm 700 700 700 920 920
B mm 210 210 210 210 210
H

C mm 500 500 500 500 500


I

D mm 450 450 450 450 450


B

E mm 780 780 780 1.000 1.000


F mm 45 45 45 45 45
F G G mm 512 512 512 732 732
A H mm 17 17 17 17 17
E

DUCT DUCT DUCT DUCT


Indoor unit SYSVRF
71 Q 90 Q 112 Q 140 Q
A mm 1.140 1.140 1.140 1.200
B mm 210 270 270 300
C mm 500 775 775 865
D mm 450 710 710 800
D E mm 1.220 1.230 1.230 1.290

C
F mm 45 65 65 80
G mm 732 933 933 969
H mm 17 35 35 40
VRF Duct indoor units | 43

Technical features

DUCT DUCT DUCT DUCT DUCT DUCT DUCT DUCT DUCT DUCT
Model Indoor unit SYSVRF
15 Q 22 Q 28 Q 36 Q 45 Q 56 Q 71 Q 90 Q 112 Q 140 Q
Art. no. with SYS WC 29 314784 314761 314762 314763 314764 314765 314766 314261 314262 314258
Art. no. with SYS RM 02 314846 314847 314848 314849 314850 314851 314852 314853 314854 314855
Power Supply V/Ph/Hz 220-240/1/50 or 60
Cooling capacity kW 1,5 2,2 2,8 3,6 4,5 5,6 7,1 9,0 11,2 14,0
Power Input W 39 39 39 45 58 89 - 108 178 204
Current A 0,31 0,31 0,31 0,33 0,36 0,36 0,47 1,0 1,8 1,55
Heating capacity kW 1,7 2,6 3,2 4,0 5,0 6,3 8,0 10,0 12,5 15,5
Power Input W 39 39 39 45 58 89 - 108 178 204
Current A 0,31 0,31 0,31 0,33 0,36 0,36 0,47 1,0 1,8 1,55
Indoor fan motor DC motor
1.400/ 1.800/ 2.250/
460/ 460/ 460/ 540/ 740/ 860/ 1.100/
Air flow (H/M/L) m3/h 1.050/ 1.600/ 1.900/
420/360 420/360 420/360 469/480 640/550 760/630 940/790
880 1.400 1.460

Sound pressure level (H/M/L) dB(A) 35/33/31 35/34/31 36/34/31 37/36/33 38/37/33 38/37/33 40/38/34 44/38/37 47/41/37 47/42/38

40 /
External static pressure Rated/Range Pa 10 / 0-50 20 / 0-100
25-150
1.220x 1.290×
Dimension (LxHxW) mm 780x210x500 1.000x210x500 1.230×270×775
210x500 300×865
1.335x 1.400×
Packing (LxHxW) mm 870×285×525 1.115x285x525 1.355×350×795
285x525 375×925
Net/gross weight kg 17,5 / 20,5 23/26 28/32 40/48 49/58
Refrigerant R410A
Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3/8”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm OD 25
Operating ambient temp. range °C Cooling +17…+32 / Heating +10…+28

Operating conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m
Heating mode 20°C DB, 15°C WB 7°C 8m 0m

The sound pressure value may vary depending on ambient conditions.


44 | VRF Duct HP indoor units

High Static Pressure Duct Indoor Units


SYSVRF DUCT HP
Features
External static pressure up to 200 Pa.
 Washable air filter placed in an aluminum frame which
is removable downward from the bottom. Easy access
both in rear and bottom.
Fresh air hole, air inlet/outlet flange are standard for
easy duct connection.
All models are equipped with high efficient DC fan motor
Electronic expansion valve (EXV) fixed inside of the
indoor unit (not for model 200 and 280).
Display board with infrared receiver as standard Wired Infrared
controller remote control
equipment. SYS WC 90 SYS RM 02
Wired controller SYS WC 90 with address setting function (standard) Art. no. 314138
(optional)
as standard equipment.
Power supply 50Hz or 60Hz.
Wired controller
SYS WC 120
Accessories/option
Art. no. 314774
(optional)

Infrared remote SYS RM 02 with address


setting function for heat pump system.
Wired controller SYS WC 120 for heat
recovery system.

Dimensions
1121 75
SYSVRF DUCT HP 71/112 Q SYSVRF DUCT HP 140 Q
60
96

952
856 135 930 88
86
29

214
343

56
82

82
85

249

270
420
420

Plastic
cover
Plastic
cover
Electrical 68 24
control box 46 Electrical
control box

SYSVRF DUCT HP 200/280 Q


936 200
1121 75
60
96

378
343

50
VRF Duct HP indoor units | 45

Technical features

Model Indoor unit SYSVRF DUCT HP 71 Q DUCT HP 112 Q DUCT HP 140 Q DUCT HP 200 Q DUCT HP 280 Q
Art. no. 314560 314561 314562 314563 314564
Power Supply V/Ph/Hz 220-240/1/50 or 60
Cooling capacity kW 7,1 11,2 14,0 20,0 28,0
Power Input W 180 380 420 800 800
Current A 1,4 2,9 4,5 6,0 6,0
Heating capacity kW 8,0 12,5 16,0 22,5 31,5
Power Input W 180 380 420 800 800
Current A 1,4 2,9 4,5 6,0 6,0
Indoor fan motor DC fan motor
1.500/ 2.080/ 2.860/ 4.820/ 4.870/
Air flow (H/M/L) m3/h
1.390/1.250 1.930/1.710 2.440/2.010 4.660/4.620 4.760/4.690
Sound pressure level (H/M/L) dB(A) 46/41/42 50/47/45 53/50/48 57/53/50 57/53/50
MCAC -VTSM -2015-07 High Static Pressure Duct Unit with DC Fan Motor
External static pressure Rated/Range Pa 25 / 0~196 37 / 0~196 50 / 0~196 62 / 40~200 62 / 40~200
7. Fan Performance
Dimension (LxWxH) mm 856x690x420 856x690x420 1.200x600x400 1.356x763x470
Heating capacity and cooling capacity are tested under the standard allowablestatic pressure;
1.356x763x470
Packing (LxWxH) themm
71 test1.090x768x440
static pressure is 25Pa, 80/90/112 test static
1.090x768x440 pressure is 37Pa, 140/160
1.436x768x450 test static pressure
1.509x964x570 is 50Pa,
the
1.509x964x570
MCAC -VTSM -2015-07 200/250/280Hightest
pressure
Static is 62Pa.
Pressure Duct Unit with DC Fan Motor
Net/gross weight kg 41/47 47/53 68/70 108/120 108/120
7. Fan Performance
Refrigerant
Heating capacity and cooling capacity are tested under the standard allowablestatic pressure;
R410A
the 71 test static pressure is 25Pa,
Liquid pipe 80/90/112 test static
mm pressure
(in) is 9,5
37Pa,(3/8”)
140/160 test static
9,5pressure
(3/8”) is 50Pa,
the 9,5 (3/8”) 9,5 (3/8”) (x2) 9,5 (3/8”) (x2)
Piping 200/250/280
dimension testpressure is 62Pa.
Gas pipe mm (in) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) (x2) 15,9 (5/8”) (x2)
Drain piping mm 32 32 32 32 32
Operating ambient temp. range °C Cooling +17…+32 / Heating +10…+28

MCAC -VTSM -2015-07 High Static Pressure Duct Unit with DC Fan Motor

7.Fan
Fan performance
Performance
Heating capacity and cooling capacity are tested under the standard allowablestatic pressure;
the 71 test static pressure is 25Pa, 80/90/112 test static pressure is 37Pa, 140/160 test static pressure is 50Pa,
the
SYSVRF DUCT HP 71 Q
200/250/280 test
pressure
High Static PressureisDuct
62Pa.
Unit with DC Fan Motor
SYSVRF DUCT HP 112 Q

ity are tested under the standard allowablestatic pressure;


, 80/90/112 test static pressure is 37Pa, 140/160 test static pressure is 50Pa,
the

SYSVRF DUCT HP 140 Q SYSVRF DUCT HP 200 Q SYSVRF DUCT HP 280 Q


High Static Pressure Duct Unit with DC Fan Motor

17

If the external static pressure is too high, caused by extensive ducting for exam
each outlet may be reduced to insufficient levels.

17
So there’s a limit air flow volume for each speed, which is the min. airflow of th
the fan achieve the max. ESP, and indoor evaporator may protect by low temp
As well, there’s a limit airflow volume, which is the max. value at each speed.
duct for air-inlet and outlet, to prevent damage from the high temperature of m
Operating conditions
This is the available static pressure range which means the unit can run stably
Indoor unit Outdoor unit and the optimal
Piping static pressureLevel
lenght range difference
please refers to the Installation Manual.

Cooling mode 27°C DB, 19°C WB 35°C DB Risks of selecting


8 m a unit outside of the0optimal
m range include higher noise leve
Heating mode 20°C DB, 15°C WB 7°C DB 8m 0m

The sound pressure value may vary depending on ambient


17 conditions.

17
46 | Exposed floor indoor unit

Exposed floor indoor unit


SYSVRF FLOOR EB
Features
With 22cm of depth and 67cm of height, the unit
perfectly fits any interior design.
 Models 71 and 80 are equipped with high efficient
DC fan motor.
Washable air filter included.
Built-in electronic expansion valve (EXV) ensuring
precise flow control.
Infrared receiver and remote controller SYS RM 02 with
address setting function as standard equipment.
Power supply 50Hz or 60Hz (only 71 and 80). Infrared remote Wired
control controller
SYS RM 02 SYS WC 29
Accessories/option (standard) Art. no. 314772
(optional)
Wired controller SYS WC 29 with address
setting function for heat pump system.
Wired
Wired controller SYS WC 120 for heat controller
recovery system. SYS WC 120
Art. no. 314774
(optional)

Dimensions
Mounting
A hole, 4 I
B

4xФ11
EXV
4xФ18
Gas side connector
Liquid side connector
D

G
C

E
F

J
Air inlet
grille

Indoor unit SYSVRF FLOOR EB 22 Q FLOOR EB 28 Q FLOOR EB 36 Q FLOOR EB 45 Q FLOOR EB 56 Q FLOOR EB 71 Q FLOOR EB 80 Q
A mm 1.000 1.200 1.500
B mm 725 925 1.225
C mm 672
D mm 592
E mm 284 310
F mm 232 258
G mm 345
H mm 94 100 100
I mm 220
J mm 150
Exposed floor indoor unit | 47

Technical features

FLOOR EB FLOOR EB FLOOR EB FLOOR EB FLOOR EB FLOOR EB FLOOR EB


Model Indoor unit SYSVRF
22 Q 28 Q 36 Q 45 Q 56 Q 71 Q 80 Q
Art. no. 314225 314226 314227 314228 314229 314285 314286
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 or 60
Cooling capacity kW 2,2 2,8 3,6 4,5 5,6 7,1 8,0
Power Input W 40 46 49 88 130
Current A 0,18 0,21 0,22 0,22 0,4 0,56 0,59
Heating capacity kW 2,6 3,2 4,0 5,0 6,3 8,0 9,0
Power Input W 40 46 49 88 130
Current A 0,18 0,21 0,22 0,22 0,4 0,56 0,59
Indoor fan motor AC fan motor DC fan motor
530/ 569/ 624/ 660/ 1.150/
Air flow (H/M/L) m3/h 1.380/1.100/870
456/400 485/421 522/375 542/440 970/830

Sound pressure level (H/M/L) dB(A) 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33

1.200× 1.200× 1.500×


Dimension (LxWxH) mm 1.000×625×220 1.500×625×220
625×220 625×220 625×220
1.382× 1.382× 1.682×
Packing (LxWxH) mm 1.182×683×312 1.682×683×312
683×312 683×312 683×312
Net/gross weight kg 30/38 35,5/41 35,5/41 42/51 42/51 44/53
Refrigerant R410A
Liquid pipe mm (in) 6,35 (1/4”) 9,5 (3/8”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm 16
Operating ambient temp. range °C Cooling +17…+32 / Heating +10…+28

Operating conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m
Heating mode 20°C DB, 15°C WB 7°C DB 8m 0m

The sound pressure value may vary depending on ambient conditions.


48 | Concealed floor indoor unit

Concealed floor indoor unit


SYSVRF FLOOR CB
Features
With only 21cm thick, the unit can be easily hidden
in narrow space.
 Models 71 and 80 are equipped with high efficient
DC fan motor.
Washable air filter included.
Built-in electronic expansion valve (EXV) ensuring
precise flow control.
Infrared receiver and remote controller SYS RM 02 with
address setting function as standard equipment.
Power supply 50Hz or 60Hz (only 71 and 80). Infrared remote Wired
control controller
SYS RM 02 SYS WC 29
Accessories/option (standard) Art. no. 314772
(optional)
Wired controller SYS WC 29 with address
setting function for heat pump system.
Wired
Wired controller SYS WC 120 for heat controller
recovery system. SYS WC 120
Art. no. 314774
(optional)

Dimensions

Connecting point
of refrigerant pipe

(Liquid side ΦA)

Connecting point
of refrigerant pipe

(Gas side ΦB)


544
345
177

C 212

MODEL A B C
FLOOR CB 22 mm 6,4 12,7 725
FLOOR CB 28 mm 6,4 12,7 725
FLOOR CB 36 mm 6,4 12,7 925
FLOOR CB 45 mm 6,4 12,7 925
FLOOR CB 56 mm 9,5 15,9 1.225
Concealed floor indoor unit | 49

Technical features

FLOOR CB FLOOR CB FLOOR CB FLOOR CB FLOOR CB FLOOR CB FLOOR CB


Model Indoor unit SYSVRF
22 Q 28 Q 36 Q 45 Q 56 Q 71 Q 80 Q
Art. no. 314232 314233 314234 314235 314236 314287 314288
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 or 60
Cooling capacity kW 2,2 2,8 3,6 4,5 5,6 7,1 8,0
Power Input W 40 46 49 88 130
Current A 0,18 0,21 0,22 0,22 0,4 0,56 0,59
Heating capacity kW 2,6 3,2 4,0 5,0 6,3 8,0 9,0
Power Input W 40 46 49 88 130
Current A 0,18 0,21 0,22 0,22 0,4 0,56 0,59
Indoor fan motor AC fan motor DC fan motor
530/ 569/ 624/ 660/ 1.150/
Air flow (H/M/L) m3/h 1.380/1.100/870
456/400 485/421 522/375 542/440 970/830

Sound pressure level (H/M/L) dB(A) 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33

External static pressure Pa 12


1.036× 1.036× 1.336×
Dimension (LxWxH) mm 840×544×212 1.336×544×212
544×212 544×212 544×212
1.139× 1.139× 1.425×
Packing (LxWxH) mm 939×639×305 1.425×639×305
639×305 639×305 639×305
Net/gross weight kg 25/27 29,5/34 29,5/34 33/39 33/39 36/40
Refrigerant R410A
Liquid pipe mm (in) 6,35 (1/4”) 9,53 (3/8”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm 16
Operating ambient temp. range °C Cooling +17…+32 / Heating +10…+28

Operating conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m
Heating mode 20°C DB, 15°C WB 7°C DB 8m 0m

The sound pressure value may vary depending on ambient conditions.


50 | VRF Heat Recovery Ventilation

Heat Recovery Ventilation Units


SYSVRF HRV
Features
Cross flow heat exchanger made of special paper for
enhanced heat exchange efficiency.
 Main structure made of galvanized steel sheet.
High efficient DC fan motor assures low power consumption.
3 fan speeds available.
SYSVRF HRV 500/1000 Q
Temperature exchange efficiency above 75%.
Compact design and flexible installation in the false ceiling.
Different operating modes available: heat exchange,
bypass, auto, exhaust/supply mode (bypass damper not
included in the HRV 2000 Q).
Insulation material guarantees quiet operation and
thermal insulation. SYSVRF HRV 2000 Q
Thanks to the flexible control the HRV unit can be
interlocked to the operation of the VRF indoor units. Wired
controller
Wired controller SYS WC 27 as standard equipment.
SYS WC 27
Can be connected to centralized controller SYS CWC30, SYS (standard)
CWC09.
Power supply 50Hz or 60Hz.

Dimensions
SYSVRF HRV 500/1000 Q SYSVRF HRV 2000 Q
L W 75
1550
Wire N2
N Door control H
box

W2
C Wire
Door control
box
Air exhaust By-pass Air return
vent system vent
Flange demension
W1 1400

Fresh Air supply


air inlet vent

L1 G
350

326

300

540

Model SYSVRF HRV 500 Q SYSVRF HRV 1000 Q


L 824 1.116 700
120
L1 754 1.045 250 320
1600
W 904 1.134
346
W1 960 1.190
20

Air exhaust Air supply 370


W2 500 678 vent vent

H 270 388
1370

C 107 85 Fresh Air return


air inlet vent
G 19 19 50 50

N Φ194 Φ242
1650
N2 111 170
VRF Heat Recovery Ventilation | 51

Technical features

Model Indoor unit SYSVRF HRV 500 Q HRV 1000 Q HRV 2000 Q
Art. no. 314289 314290 314291
Power supply V/Ph/Hz 220-240/1/50 or 60
Indoor Fan motor DC fan motor
Nominal air flow (H) m3/h 500 1.000 2.000
External static pressure (H) Pa 80 100 170
Power input W 170 360 1.340
Enthalpy exchange efficiency/
% 78,2/80,4 76,9/78,6 78,7/80,3
Cooling / Heating
Temperature exchange efficiency
% 76,1/76,1 75,8/75,8 77,2/77,2
Cooling / Heating
Sound pressure level (H) dB(A) 35 40 53
Dimensions (LxWxH) mm 1.020x1.036x270 1.276x1.269x388 1.650x1.470x540
Packing (LxWxH) mm 1.120x1.120x452 1.390x1.350x570 1.760x1.580x720
Net/gross weight kg 35/60 69/100 165/247
Duct connection dimensions mm ⌀194 ⌀242 346x326
Ambient condition °C -7…+43/ max 80% RH

Fan performance
SYSVRF HRV 500 Q SYSVRF HRV 1000 Q SYSVRF HRV 2000 Q
675 1300 3050
650 1250 2900
Air flow (m3/h)

Air flow (m3/h)

Air flow (m3/h)


625 1200 2750
600 1150 2600
575 1100 2450
550 1050 2300
525 1000 2150
500 950 2000
20 40 60 80 100 120 150 170 20 40 60 80 100 120 150 170 20 40 60 80 100 120 150 170

External static pressure (Pa) External static pressure (Pa) External static pressure (Pa)

Multi-modes for different applications


Heat exchange mode Heat exchange mode Bypass mode
Damper Damper
When air flow formed by the fans goes through the
EA RA E A RA
heat exchanged core in cross way, due to temperature
difference between two channels of the core, thermal Element Element

transmission happens naturally. In summer days, high OA S A OA SA

temperature outdoor air gets cooled by indoor exhaust


air; in winter, low temperature outdoor air gets heated by EA=Exhaust air RA=Return air
indoor exhaust air. So the energy contained in exhaust air OA=Outdoor air SA=Supply air

can be reclaimed and energy efficiency gets improved.

Bypass mode Exhaust air mode

In mild climate areas or seasons, when temperature and It is also one kind of bypass mode with exhaust fan speed
humidity level difference between indoor and outdoor is higher than air supply fan speed. It can be used in mild
small, the unit works as conventional ventilation fan. Both climate area where large amount exhaust air needs to be
supply fan and exhaust fan works at the same speed (Hi/ expelled.
mid/low/auto).
Auto mode
Air supply mode The controller chooses heat exchange mode or bypass
It is one kind of bypass mode with air supply fan speed mode according to the temperature difference between
higher than exhaust fan speed. It can be used in mild outdoor and indoor temperature. Both the two fans work
climate area where large amount fresh air is needed. at low speed.

Operating conditions

Exhaust air Fresh air


Cooling mode 27°C DB, 19,5°C WB 35°C DB, 28°C WB
Heating mode 21°C DB, 13°C WB 5°C DB, 2°C WB

The sound pressure value may vary depending on ambient conditions.


52 | VRF connection to AHU

Connection to DX coil
SYSVRF AHU
Features
The SYSVRF AHU 5HP, 10HP and 20HP can be used
to connect the SYSVRF outdoor units to an external DX
coil with capacity from 9 kW to 56 kW.

 Nominal capacity in cooling 14kW (5HP), 28kW (10HP)


and 56kW (20HP). Wired Infrared
controller remote control
Modulating cooling/heating capacity thanks to the SYS WC 29 SYS RM 02
built-in Electronic Expansion Valve (EXV) controlled (standard) Art. no.
314138
by the superheat degree of the DX coil. (optional)
The SYSVRFAHU kit includes four temperature
sensors, one for the air intake of the AHU and three for Failure alarm codes on the PCB for quick service
a precise monitoring of the DX evaporator coil. checking.
With the 2nd generation it is possible to connect Environment friendly R410A refrigerant.
in pararrel up to 4 AHU boxes with Master-Slave Connection to Systemair network monitoring system.
configuration thus reaching a total capacity of 224kW Wired controllor SYS WC 29 as standard equipment.
in a single refrigerant circuit. Power supply 50Hz or 60Hz.
For indoor installation in vertical position.
Connection diagram

max 8 m
SYSVRF indoor units

SYSVRF
AHU
max
175 m
SYSVRF
outdoor FRICO Air Curtain
unit

max 8 m
SYSVRF AHU SYSTEMAIR Air Handling Unit
Technical features

Model AHU box (1st generation) SYSVRF AHU 5HP SYSVRF AHU 10HP SYSVRF AHU 20HP
Model AHU box (2nd generation) SYSVRF AHU 5HP S SYSVRF AHU 10HP S SYSVRF AHU 20HP S
Art. no. (1st generation) 314188 314189 314190
Art. no. (2nd generation) 313395 313396 313397
Power supply V/Ph/Hz 220-240/1/50, 208-230/1/60
DX coil capacity kW 9-20 20-36 36-56
Air volume m3/h 1.400-2.700 3.000-4.500 5.400-7.500
Dimensions (LxWxH) mm 375x350x150
Packing (LxWxH) mm 490x240x420
Piping diameters in/out mm 8/8 12,7/12,7 '16/16
IP-class IP X0 IP X0 IP X0
Air return temperature range °C Cooling +17 … +43 / Heating -5 … +30 / 80% / humidity
VRF connection to AHU | 53

SYSVRF selection
and designing software
Selection and designing software for all SYSVRF systems, 2-pipe, 3-pipe and Mini-VRF.

Main tasks:
Calculation of the heat loads and selection of the
necessary cooling /heating capacity, type and location
of outdoor and indoor units.
Calculation of the refrigerant piping diameters and
the required additional amount of refrigerant.
Selection of an optimal set of piping joints.
Building Management System.
Correction of the performance of indoor units.
Automatic check of the circuit for compliance
requirements and limits on the maximum length of
refrigerant pipelines and indoor-outdoor elevations.
Conclusion of project documentation - specification
(Excel), a detailed specification with the drawings
(Word), and print out of all documents.
Selection of the DX-coil connected to the SYSVRF AHU
box.
54 | VRF control systems

Control systems

Remote control for indoor units


Infrared remote controller SYS RM 02, Art. no. 314138
Turn On/Off
Setting mode Cool/Heat/Auto/Dry/Fan
Temperature setting
Fan speed selection High/Medium/Low/Auto
Air swing function
24h On/Off timer
Economy mode
Turbo function
Turn on/off the LCD backlight
Setting the address of indoor units

Wired controller with touch-key buttons SYS WC 29 (for 2-pipe systems),


Art. no. 314772
Wired controller with touch-key buttons SYS WC 120 (for 3-pipe systems), Art. no.
314774
Main functions:
Turn On/Off
Setting mode Cool/Heat/Auto/Dry/Fan
Temperature setting
Fan speed selection High/Medium/Low/Auto
Air swing function
24h On/Off timer
Silent mode operation
Locking the controller’s buttons
Indication of air filter cleaning
Follow me function (SYS WC29 only)
IR signal receiver for the infrared remote controller (SYS WC 29 only)
Setting the address of indoor units (SYS WC 29 only)
2-ways communication (SYS WC 120 only)

Group controller for indoor units SYS WC 150, Art. no. 314787
The group controller allows to control up to 16 indoor units from a single local controller.
It can be matched to:
Infrared remote controller SYS RM 02, Art. no. 314138
Wired controlled SYS WC 29, Art. no. 314772
VRF control systems | 55

Centralized controller with touch-key buttons SYS CWC 30, Art. no. 314773
The centralized remote controller is intended to control a group of indoor units (up to
64 indoor units).
Main functions:
Turn On/Off
Setting mode Cool/Heat/Auto/Dry/Fan
Temperature setting
Fan speed selection High/Medium/Low/Auto
Air swing function
24h On/Off timer
Silent mode operation
Locking the controller buttons
Indication of air filter cleaning
Turn on/off the LCD backlight
The centralized controller allows to set all operating parameters for each indoor unit
separately or for a group of indoor units at the same time.
It provides the ability to connect to a PC via a converter RS485/RS232.

Centralized controller with weekly timer SYS CWC 09, Art. no. 314141
The centralized remote controller is intended to control a group of indoor units (up to
64 indoor units). It performs the same functions of the centralized controller SYS CWC
30, with the possibility of drawing up management programs for the week with up to 4
different modes per day.
It doesn’t have the R485 port for the connection to a PC.

Central controller for outdoor units SYS CWC 02, Art. no. 314142
Remote control designed to monitor the SYSVRF outdoor units (max. 32 outdoor units
/ 8 systems).
This controller greatly simplifies the maintenance of the SYSVRF installation, since it has
an error indicator and allows the technician to check the operating status of all major
components of the system, monitor temperature, fan speed, operation of electronic
expansion devices, operation of compressors, etc...
If the outdoor unit is equipped with a power meter, the controller performs an accounting
function of the consumed electricity.
SYS CWC 02 can communicate with a PC through a RS485/RS232 converter and one PC
can connect up to 16 outdoor controllers SYS CWC 02.

Data Converter SYS CWC 15, Art. no. 314263


Provides the ability to manage the indoor units from a PC, tablet or smartphone (with
Android OS) and other intelligent terminals (up to 64 indoor units).
Provides data conversion between the protocols TCP/IP and RS485.
Provides a TCP / IP port for accessing WEB/HTTP/TCP/IP.
Built-in web server allows you to organize access through the cloud service.
The user receives access to the SYSVRF system management through LAN and WAN.
The user can check and set the following functions: On/Off, setting temperature,
operating mode and fan speed. Allows individual and group control, indicates the status
of each indoor unit, setting weekly timer, lock the operating parameters and the remote
controller, provides the list of error codes.
56 | VRF control systems

Central management IMS (Intelligent Manager of Systemair)


The system provides full control of the SYSVRF system, as well as monitoring of all relevant operating parameters. It can
manage up to 1024 indoor units and up to 256 outdoor units.
The main elements of a centralized control system:
Interface unit (gateway) SYS M-INTERFACE, Art. no. 313735.
The system allows the connection of up to 4 interface blocks. A gateway is designed to operate with 256 indoor units
and 64 outdoor units.
Software IMS software, Art. no. 313734.
The remote control of the SYSVRF installation can be performed from a PC, tablet, mobile phone and other intelligent
terminals. The module is compatible with complex building management systems (BMS).
Router connection interface units and communication networks (not supplied by SYSTEMAIR).

Main functions:
Individual control with system blocks: switching modes, setting temperatures, lock local controllers.
User can set limits to any parameter of indoor unit, such as cooling/heating temperature set-point, fan speed, operating
mode, etc…
Simple schedule control, automatically performs facility start/stop control, switches the operating mode, sets temperatures
and enabling/disabling the remote control according to the present time schedule.
Electricity charge apportionment can be performed easily for the power consumed, when billing users for air conditioning
power charges, such as tenants in a commercial building, offices in a rental building, or rooms in a hotel.
Automatic backup web-gateway to SD-card in the event of failures of the power supply or system fault. Storing data
on a hard disk in the last three months.
Indication of filter cleaning.
Fault and reported them to mobile communications.
Emergency stop function and connection to external signals through contacts.

Maximum:
• 1024 indoor units;
• 256 outdoor units;
• 64 independent refrigerant circuits.
VRF control systems | 57

Connection to an integrated building management system (BMS)


SYSVRF systems can be integrated into a comprehensive building management system (BMS) using all most popular
protocol: Bacnet, Modbus, LonWorks and KNX.
Gateway SYS CWC 08 (Bacnet Protocol), Art. no. 314145
One gateway SYS CWC 08 can connect up to four central controller (SYS CWC 30 or SYS CWC 02). Each group can contain
a maximum of 64 indoor units or 32 outdoor units.
Bacnet

RM 02 WC 29/120

Мax. 64
Bacnet CWC 30
BMS

Мax. 64
CWC 30
CWC 08

Мax. 64
CWC 30

Power digital meter Мax. 32

C C 02
CWC

Gateway SYS CWC 18 (Modbus protocol), Art. no. 314382


One gateway SYS CWC 18 can connect directly up to 64 indoor units or 4 outdoor units.

Modbus

Modbus
BMS RM 02 WC 29/120

Мax. 64

Мax. 4
CWC 18

Gateway SYS CWC 64 (Lonworks protocol), Art. no. 314144


One gateway SYS CWC 64 can connect directly up to 64 indoor units.
LonWorks

Lonwork
BMS

RM 02 WC 29/120

CWC 64 Мax. 64

Gateway SYS CWC 01 (KNX protocol), Art. no. 314788


The gateway SYS CWC 01 should be connected directly to a single indoor unit.
58 | Controller table VRF

Controller matching table - VRF units

Wired controller Wired controller SYS WC Wired controller


Infrared controller
SYS WC 29 120 SYS WC 27 Remote On/Off
SYS RM 02
(1way communic.) (2ways communic.) (1way communic.)

Art. no. 314138 314772 314774 314856 standard in the PCB

Picture

CASSETTE MINI l -- l

CASSETTE l -- l

DUCT l -- l

CEILING l -- l

WALL l -- l

DUCT HP l -- l

CASSETTE 1W l -- l

CASSETTE 2W l -- l

FLOOR EB l -- l

FLOOR CB l -- l

HRV -- -- l --

AHU box (1st generation) l -- l

AHU box (2nd generation) l -- l

l= included in the unit; = optional part; - = not available.


Controller table VRF | 59

BMS gateway Intelligent Manager


Group control SYS Central controller SYS Central controller SYS SYS CWC 18, SYS CWC Data Converter of Systemair
Alarm contact
WC 150 CWC 30 CWC 09 64, SYS CWC 15 IMS + SYS M-INTER-
SYS CWC 08, SYS CWC 01 FACE
314382, 314144,
standard in the PCB 314787 314773 314141 314263 313734 + 313735
314145, 314788

-- --

l
only with SIEMENS only with SYSTEMAIR only with SYSTEMAIR only with SYSTEMAIR only with SYSTEMAIR only with SYSTEMAIR only with SYSTEMAIR
controller controller controller controller controller controller controller
60 | VRF piping joint

Piping joints for 2-pipe refrigerant system


SYSVRF JOINT

Outdoor unit

Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use
SYSVRF JOINT OUT 02 HP 314146 255x150x185 1,5 Connect two outdoor units of SYSVRF AIR EVO HP R series
SYSVRF JOINT OUT 03 HP 314147 345x160x285 3,4 Connect three outdoor units of SYSVRF AIR EVO HP R series
SYSVRF JOINT OUT 04 HP 314148 475x165x300 4,8 Connect four outdoor units of SYSVRF AIR EVO HP R series

Indoor unit

Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use
SYSVRF JOINT IN 01 2P 314149 290x105x100 0,4 Capacity of connected indoor units < 23 kW
SYSVRF JOINT IN 02 2P 314150 290x105x100 0,6 Capacity of connected indoor units 23-33 kW
SYSVRF JOINT IN 03 2P 314151 310x130x125 0,9 Capacity of connected indoor units 33-92 kW
SYSVRF JOINT IN 04 2P 314152 350x180x170 1,5 Capacity of connected indoor units 92-135 kW
SYSVRF JOINT IN 05 2P 314153 365x195x215 1,9 Capacity of connected indoor units > 135 kW
SYSVRF JOINT IN 06 2P 314154 390x230x255 3,1 Capacity of connected indoor units 185 kW and long piping

Piping joints for 3-pipe refrigerant system


SYSVRF JOINT

Outdoor unit

Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use
SYSVRF JOINT OUT 02 HR 314155 272×167×232 2,2 Connect two outdoor units of SYSVRF AIR EVO HR R series
SYSVRF JOINT OUT 03 HR 314156 472×157×312 5,0 Connect three outdoor units of SYSVRF AIR EVO HR R series
SYSVRF JOINT OUT 04 HR 314184 745×160×335 7,5 Connect four outdoor units of SYSVRF AIR EVO HR R series

Indoor unit

Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use
SYSVRF JOINT IN 01 3P 314157 257×127×107 0,8 Capacity of connected indoor units < 16,6kW
SYSVRF JOINT IN 02 3P 314158 287×137×107 0,9 Capacity of connected indoor units 16,6-33kW
SYSVRF JOINT IN 03 3P 314159 297×167×177 1,4 Capacity of connected indoor units 33-66kW
SYSVRF JOINT IN 04 3P 314160 372×197×187 2,3 Capacity of connected indoor units 66-92kW
SYSVRF JOINT IN 05 3P 314185 432×222×227 3,3 Capacity of connected indoor units > 92kW
Italia
Systemair srl
Via XXV Aprile, 29

www.systemair.it
Tel. +39 0362 680 1
20825 Barlassina (MB)

Fax +39 0362 680 693


Systemair · VRF Catalogue-S-3GB(04.17)
As part of our ongoing product improvement programme, our products are subject to change without prior notice. Non contractual photos.

You might also like