GEOSENSE QUALITY FORM

FORM No G/QF/125
ISS. 6
DATE : Jan-16
SIG. GC

VIBRATING WIRE DISPLACEMENT TRANSDUCER CALIBRATION


Model VWDT 5000 Cal date 24-Jan-17
Serial 508843 Master 09140261
Works ID 149 Temp oC 20
Cable m 0 Batch 74
Readout No. 6703 Range mm 50
R/O Cal.Date 18/04/2016

Indicated Displacement
Applied Displacement Hz2 *10-3 Linear Error Polynomial Error Deviation Hysteresis
(mm)

mm 1 up 1 down Avg. Digit Linear Poly. % FSO % FSO Digit %


0.00 2613.9 2665.0 2639.4 -0.22 -0.04 -0.44% -0.08% 26 0.61
10.00 3498.0 3502.8 3500.4 10.12 10.08 0.24% 0.16% 2 0.06
20.00 4330.6 4334.5 4332.6 20.12 19.97 0.23% -0.05% 2 0.05
30.00 5162.2 5169.6 5165.9 30.12 29.98 0.25% -0.03% 4 0.09
40.00 5983.7 5994.2 5988.9 40.01 39.98 0.02% -0.04% 6 0.13
50.00 6801.8 6813.2 6807.5 49.84 50.02 -0.32% 0.04% 6 0.14

CALIBRATION FACTORS

Linear factor k (mm) Polynomial factors (mm)


mm / digit mm / digit
0.012010465 A 7.69983E-08
B 0.011282852
C

Calibration of Linear potentiometer S/N: 09140261 valid from 28 September 2016. UKAS Certificate of calibration No.416889 (UKAS Accredited Calibration
Laboratory 0495)
Calibration of CR3000-RMA S/N 7935 valid from 30th April 2015, Calibrated using equipment which
provides traceability to UKAS standards (Certificate NO 150430626)

Calibration of AVW200 S/N: 6703 valid from 18th April 2016, Calibrated using equipment which provides traceability to UKAS standards (UKAS Laboratory No
0152)

Users must establish site zero base readings for Linear calculation purposes

Linear calculation [mm] = k (mm) * (Current Reading - Site Zero Reading)

Polynomial calculation [mm] = A * (Reading²)2 + B * (Reading) + C


C = -A*(Site Zero Reading²) - B*(Site Zero Reading)
Note: Readings are taken in frequency squared units.
Please refer to User Manuals if reading in period or frequency units

THIS CERTIFICATE IS VALID ONLY WHEN CARRYING THE


OFFICIAL ORIGINAL STAMP OF GEOSENSE