Highlights of AAU (RRU) Power Connections Inspection and Rectification - R3.0
Highlights of AAU (RRU) Power Connections Inspection and Rectification - R3.0
History
AAU/RRU
Filter high-risk alarm/performanc
power supply
sites e data analysis
survey
tool
There is a diagram of cable striping rule inside the maintenance window, as shown in the following figure:
Rectification Operations
1. Observe whether the power cables are 2. Open the maintenance window, 3. Observe the maintenance window and
adaptive. It is prohibited to use the power remove the power connectors, and power socket. If there is visible damage,
cable of a smaller specification. If there is check whether there is any burn conductor pollution, or corrosion on the
any power cable smaller than the required mark. maintenance window, replace the RRU.
specification, replace the cable.
Type O 10mm²
power cable
Type D 6mm²
power cable
4. Observe whether the power cable connectors have tubular terminals. If no, install the tubular terminals of the matching model and crimp
them with a special crimping tool.
Indented side
faces up
No tubular terminal,
naked copper wire:
risk of poor contact The other three
and short circuit sides are flat
White sheath:
10 mm² tubular The cross section is in
terminals are the trapezoidal shape
crimped
5. Check whether the shielding layer of the power cable is crimped reliably and whether the outer sheath
of the power cable is stuck with the waterproof sealing ring. Otherwise, rectification is needed.
Spring-type power
Indented Side Facing Up
connector :
Insert the terminal into
the bottom of the holes,
and do not open the
spring plate with a
screwdriver.
Indented Side Facing Up
Typical Scenarios
Side window of Dual-screw Side window of Dual-screw Side window of Dual-screw Side window of Dual-screw
power connector power connector power connector power connector
Tubular terminals are not The terminal not tightly pressed The terminals are not The terminals are not corrected The tubular terminals are The maintenance
installed, and this may cause and can be removed, so there is a crimped properly, and there correctly: The smooth side should not all inserted to the bottom, window is not tightened,
unreliable connection. risk of unreliable connection. is not enough contact area. face down and the indented side leading to poor contact. so moisture may enter.
should face up.