DATA SHEET

FJM-MAN
Manual Fog/Jet Monitor

Description
A
n  range of manually operated fog/jet, water, and foam
monitors with exceptional flow characteristics that
optimise throw range.
E
n xceptional delivery of water or foam as a jet or as a spray
pattern.
T
n he FJM-MAN Manual Fog/Jet Monitor range is available
for a number of alternate mounting positions.
F
n JM and the FJM-S options available. The FJM-S monitor
has an inbuilt foam concentrate inductor, eliminating the
need for a separate proportioning system.

Application
The FJM range of fog/jet monitors are designed for easy
operation and reliability. Its lighter construction materials
ensure an overall light weight.
Listings and Approvals
FJM monitors have a wide operating range and are site
adjustable to any demands of the local environment, while Det Norske Veritas DNV
n 

still maintaining the highest level of performance. Bureau Veritas


n 
Note: When running any of the FJM-S range of monitors, adjust to Russian Maritime Register of Shipping (RMRS)
n 
nominal capacity for accurate proportioning.
EN 13565-1 Only sizes 80 and 100 (CNBOP)
n 

Features
Wide capacity range
n 

Adjustable flow
n 

Compact and balanced design


n 
Ordering Information
Low weight
n  Please specify the following:
Easily manoeuvred due to low friction bearings
n  1. Part number
Long throw length
n  2. Type
Adjustable stream pattern
n  3 Flange type
Corrosion resistant construction of stainless steel and
n  4. Capacity: flow and pressure
bronze 5. Foam induction (S-version)

Connections
Foam/water inlet: flanged according to DIN PN 16,
n 
JIS 10K, or ANSI 150 lb

Optional Components
Built-in inductor optional on all models (S Version)
n 

Gear operation; optional for FJM-150, standard for FJM-200


n 

Suction hose and valve


n 

Tyco Park  |  Grimshaw Lane  |  Newton Heath  | Manchester |  M40 2WL  | Tel: +44 (0) 161 259 4000  | www.skum.com
© 2020 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document
revision date and are subject to change without notice.  |  Form No. FDS-2016038-02
Ordering Information FJM-80 FJM-80 S
Part No. Description
300 350
161008407
n  FJM-80 DIN/ANSI
161008319
n  FJM-80 JIS
161008340 
n  FJM-80 S DIN/ANSI, ~295 ~295
excluding suction hose
161008537 
n  FJM-80 S JIS,
excluding suction hose
150 80 DIN PN 16 or 150
160208305
n  FJM 80 ANSI 3 in. ANSI 150
161008423 FJM-80 S ANSI,
n  lbs or 80 JIS B Male 1 1/4 in.
excluding suction hose 2210 10 K BSP
161008618 FJM-80 suction hose
n 
1 1/4 in. 3 m
161010403
n  FJM-100 DIN/ANSI
161010216
n  FJM-100 JIS
455 455
161010315 
n  FJM-100 S DIN/ANSI,
excluding suction hose
161010417
n  FJM-100 ANSI
161010329 FJM-100 S ANSI,
n 
excluding suction hose
Foam
16101606
n  FJM-100 suction hose 2 in. 3 m
161015304
n  FJM-150 DIN/ANSI/JIS
161015405 FJM-150 S DIN/ANSI,
n 
excluding suction hose
161315317
n  FJM-150 G DIN/ANSI/JIS
161315338 FJM-150 S G DIN/ANSI/JIS,
n 
excluding suction hose
FJM-80 Monitor - Range of Jet
161015608
n  FJM-150 suction hose 2 in. 3 m
161320127
n  FJM-200 G DIN
161320229
n  FJM-200 G ANSI
162020260 
n  FJM-200 S G ANSI,
excluding suction hose
161320236
n  FJM-200 G JIS
162020267 
n  FJM-200 S G JIS,
excluding suction hose
161020618 
n  FJM-200 suction hose
2.5 in. 3 m

FJM Monitors - Capacity Ranges

Reaction force (N) = 0.233 x Q (Lpm) x √p (bar)


Note: Achieving the values listed in the range of jet graph depends on
the monitor’s elevation angle. For further details, see the length-height
relationship graph.

bar
FJM-100 FJM-100 S FJM-150 FJM-150 S
380 350

~760 550 650


~335 ~335 ~760

170 100 DIN PN 16 170 222


150 DIN PN 16 222
or 4 in. ANSI Male 2 in. or 6 in. ANSI
150 lbs or 100 BSP 150 lbs or 150
JIS B 2210 10 K
JIS B 2210
10 K

Foam conc.
Male 2 in.
BSP
520 520
920 920

Foam

FJM-100 Monitor - Range of Jet FJM-150 Monitor - Range of Jet

Reaction force (N) = 0.233 x Q (Lpm) x √p (bar)


Note: Achieving the values listed in the range of jet graph depends on
the monitor’s elevation angle. For further details, see the length-height
relationship graph.

Reaction force (N) = 0.233 x Q (Lpm) x √p (bar)


Note: Achieving the values listed in the range of jet graph depends on
the monitor’s elevation angle. For further details, see the length-height
relationship graph.
FJM-150 G FJM-150 SG FJM-200 G FJM-200 SG
~690 ~720 ~920
~590 ~200
~200

Male
264

150 DIN PN 16 264 2 in. 279


282
or 6 in. ANSI BSP
200 DIN PN 16
150 lb or 150
or 8 in. ANSI
JIS B 2210
150 lbs or 200
10 K
JIS B 2210 10 K
Foam conc.
Male 2 in.
BSP

~790
~790 ~1010
~1010

Foam

FJM-200 Monitor - Range of Jet

m Lpm

Reaction force (N) = 0.233 x Q (Lpm) x √p (bar)


Note: Achieving the values listed in the range of jet graph depends on
the monitor’s elevation angle. For further details, see the length-height
relationship graph.
Length - Height Relationship
FJM Monitors - Average
FJM Monitors - Average Fog Pattern
HEIGHT OF JET Fog
in Still Pattern (in still air)
Air
(% MAXIMUM HEIGHT OF JET)

HEIGHT OF THROW AS FUNCTION OF

Foot print
MAXIMUM RANGE OF JET AT DIFFERENT
MONITOR BRANCH PIPE ELEVATION

2/3
~1/3 of R
R

~1/3 of R
LENGTH OF JET
(% MAXIMUM LENGTH OF JET)

Reaction force (N) = 0.233 x Q (Lpm) x √p (bar)

Performance Data
FJM series
standard 80 100 150 200
Water capacity Max. 3,700 Lpm Max. 6,000 Lpm Max. 11,700 Lpm Max. 20,000 Lpm
Min. 500 Lpm Min. 1,000 Lpm Min. 3,000 Lpm Min. 8,000 Lpm
Design pressure 4-16 bar 4-16 bar 4-16 bar 4-13 bar
optimum 10-12 bar optimum 10-12 bar optimum 10-12 bar optimum 10-12 bar
Rotation 360º 360º 360º 360º
Elevation -60º / +90º -60º / +90º -60º / +70º -60º / +70º
Connection flange Stud bolt Stud bolt Open hole Open hole
Weight 14 kg 22 kg 57 kg 90 kg

FJM series
built-in inductor 80 100 150 200
Water capacity Max. 3,700 Lpm Max. 6,000 Lpm Max. 11,700 Lpm Max. 20,000 Lpm
Min. 500 Lpm Min. 1,000 Lpm Min. 3,000 Lpm Min. 8,000 Lpm
Design pressure 4-16 bar 4-16 bar 4-16 bar 4-13 bar
optimum 10-12 bar optimum 10-12 bar optimum 10-12 bar optimum 10-12 bar
Foam capacity 170 Lpm 320 Lpm 600 Lpm 600 Lpm
Elevation -45º / +90º -45º / +90º -45º / +70º -45º / +70º
Suction connection 1 1/4 in. BSP male 2 in. BSP male 2 in. BSP male 2 in. BSP male
Weight 15 kg 24 kg 60 kg 93 kg