Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 5

DESIGN OF ONE WAY SLABS

When Ly>Lx, parts of length Lx at each end are to be veiwed as halves of a panel with a side ratio of 2.
The central part is to be viewed as a one-way slab as indicated in the figure below where part I is calculated
and reinforced as the left half of panel I' and part III as the right hand half of panel III'.
part II is reinforced as one way slab.

I II III

Lx
Lx Lx

Lx I'

2Lx

II

III'

Lx [m] Ly [m] 2*Lx [m]


1.12 3.60 2.24

0 S 1

ANALYSIS & DESIGN OF SOLID SLAB


Panel Type Case No.= 9
C-25 Fck 20.00 Fcd 11.33 0
S-300 Fyk 300.00 Fyd 260.87

0 S-I' 0

ba for 2:1 ba for 1:1 Ratio calc. ba calc 0


25.00 35.00 2.00 25.00 1 -Continuous
Lx/4 0.28 0 -Discontinous

Panel Name S-I' D [mm]


Depth Lx [m] Ly [m] ba calc d [mm] 50.00
1.12 2.24 25.00 17.92 120.00
D-Load Floor finish 5cm Screed Self Weight Ceiling Plaster Other.D.Load
0.20 1.15 3.00 0.46 0.00
Wall Load L(in) L(out) Wall Height Wall unit wt q
0.00 0.00 3.18 3.02 0.00
Total dead load 4.81 Cover [mm]
Live Load 0.50 15.00
Design load =1.3*DL+1.6*LL= 7.05
r values r1 r2 r3 r4 nd
0.00 0.00 0.00 0.00 4.00
Alpha values axs a ys a xf a yf b
0.00 0.00 0.111 0.056 0.44
Mxs Mys Mxf Myf
Design Moment 0.00 0.00 0.98 0.50
k-value 10 10 100 50 2
r 0.00 0.00 0.04 0.02
Amin [mm2] 169 169 169 169
Ascal [mm ]2
0 0 37 19
Asfinal[mm2] 169 169 169 169
# of bars # of bars # of bars # of bars
6 6 6 6
f 8 8 8 8
S.max [mm] 240 240 240 240
S.calc[mm 290.00 290.00 290.00 290.00
S.final [mm 240.00 240.00 240.00 240.00
Load Transfer on Beams Ly/Lx= 2.00
Shear coeffcient bvcx bvdx bvcy bvdy
0.00 0.50 0.00 0.33
Load on Beams Rcx Rdx Rcy Rdy
Total design load N.A. 3.95 N.A. 2.61
Live Load N.A. 0.28 N.A. 0.18
Dead Load N.A. 2.69 N.A. 1.78

Note:- N.A.-Means Not Applicable

Panel Type Case No.= 8


C-25 Fck 20.00 Fcd 11.33 0
S-300 Fyk 300.00 Fyd 260.87

0 S-III' 1

ba for 2:1 ba for 1:1 Ratio calc. ba calc 0


30.00 40.00 2.00 30.00 1 -Continuous
Lx/4 0.28 0 -Discontinous

Panel Name S-III' D [mm]


Depth Lx [m] Ly [m] ba calc d [mm] 40.00
1.12 2.24 30.00 14.93 120.00
D-Load Floor finish 5cm Screed Self Weight Ceiling Plaster Other.D.Load
0.20 1.15 3.00 0.46 0.00
Wall Load L(in) L(out) Wall Height Wall unit wt q
0.00 0.00 2.65 3.02 0.00
Total dead load 4.81 Cover [mm]
Live Load 0.50 15.00
Design load =1.3*DL+1.6*LL= 7.05
r values r1 r2 r3 r4 nd
0.00 1.33 0.00 0.00 3.00
Alpha values axs a ys a xf a yf b
0.00 0.059 0.104 0.044 0.42
Mxs Mys Mxf Myf
Design Moment 0.00 0.52 0.92 0.39
k-value 10 60 100 40 2
r 0.00 0.02 0.03 0.01
Amin [mm2] 169 169 169 169
Ascal [mm2] 0 20 35 15
Asfinal[mm2] 169 169 169 169
# of bars # of bars # of bars # of bars
6 6 6 6
f 8 8 8 8
S.max [mm] 240 240 240 240
S.calc[mm 290.00 290.00 290.00 290.00
S.final [mm 240.00 240.00 240.00 240.00
Load Transfer on Beams Ly/Lx= 2.00
Shear coeffcient bvcx bvdx bvcy bvdy
0.00 0.48 0.45 0.30
Load on Beams Rcx Rdx Rcy Rdy
Total design load N.A. 3.82 3.55 2.37
Live Load N.A. 0.27 0.25 0.17
Dead Load N.A. 2.61 2.42 1.62

Note:- N.A.-Means Not Applicable

DESIGN OF S-II'
SPAN MOMENT SUPPORT MOMENT RA RB
SIMPLY SUPPORTED wl2/8 0 wl/2 wl/2
END SPAN 9wl2/128 wl2/8 3wl/8 5wl/8(fixed end)
INTERIOR SPAN wl2/24 wl2/12 wl/2 wl/2
DEAD LOAD= 4.81 KN/m2
LIVE LOAD= 0.50 KN/m2
DESIGN LOAD= 7.053 KN/m2

MAXIMUM MOMENTS FOR SIMPLY SUPPORTED CASE


SPAN MOMENT= 1.11 KN.m
SUPPORT MOMENT= 0.00 KN.m

REACTIONS FOR SIMPLY SUPPORTED CASE

LIVE DEAD
RA= 0.28 2.69
RB= 0.28 2.69 (FIXED END FOR END SPAN CASE)

Reinforcement d= 101.00
Span
msd= Msd/(fcdbd2) 0.009569
From the general design chart, z= 0.99 kz= z*d= 99.50445 mm

As= Msd/zfyd= 42.60 mm2 As,min= 202 mm2 Smax= 240 mm


There fore, Use Dia.= 8 c/c 240.00 mm
d= 101.00
support
msd= Msd/(fcdbd2) 0.000
From the general design chart, z= 1.00 kz= z*d= 101 mm

As= Msd/zfyd= 0.00 mm2 As,min= 202 mm2 Smax= 240 mm


There fore, Use Dia.= 8 c/c 240.00 mm