Professional Documents
Culture Documents
XTOUCH RC1 Software Update Procedure
XTOUCH RC1 Software Update Procedure
Software update on the X-TOUCH System might be necessary for user who purchased
iPhone5 adapter and/or X-NAV.
[Software versions]
*In case there are different user reprogram package, such as SoC A/M/H 2920 or 2922, please refer to the campaign
information released by campaign information team.
A) Preparation
Caution:
- Do not remove the USB memory with update data until the update process is complete.
- Fully charge the battery before performing the update or keep the engine running.
Remark
-USB memory size must be a minimum of 1GB.
-In case update was unsuccessful, please try again with another USB
Software Preparation
1. Execute the file “XTOUCH RC1 software update.exe” by double clicking on it.
A) Preparation
2. Click on the “Extract” button and wait for the process to be completed
3. Once the process is completed, copy the folder “13psa” and place it on the root of an
empty USB stick
B) Version Check Before Update 4. Press the “Service Information” button in
“Service Menu”.
1. Start the engine.
3X + DA
B) Version Check Before Update
7. Confirm the program version in “Unit Versions listed below and previous versions are
Version Information” based on following the applicable versions that update is necessary.
information.
Applicable versions;
-SysComMain 705
-SoC A/M/H 0705
201
705
705
52002003
If the program version is required to update,
13120A
please go to C) Program Version Update.
2 3
C)Program Version Update
5. Press the “Program Update” button in 7. Insert USB stick with the new software
“Diag Menu”. into the USB slot. The screen will
change automatically and then check the
Diag Menu
version.