Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Document number: 72.120.

301/A

Document Name: Fluenta Flare Gas Meter


FGM 160

Weight Data Sheet

Scope:

Additional Information (when applicable)

A 2007.12.06 Issued for Fluenta release. MS RT N/A AAJ


Rev. Review
Issue date Reason for issue Author Review Review Approved
index by QA

Replacement for: 018210/A


Total no. of pages: 4
Fluenta doc. Ref:

71.000.001_A
Doc. nr: 72.120.301/A
Doc. name: FGM 160 - Weight Data Sheet

TABLE OF CONTENTS
1. Purpose.................................................................................................... 3
2. Abbreviations/Definitions ............................................................................ 3
2.1 Abbreviations:..................................................................................... 3
2.2 Definitions: ......................................................................................... 3
3. Weight Data Sheet..................................................................................... 3
3.1 Transducer Full Size Weight Data Sheet .................................................. 3
3.2 Transducer Compact Version Weight Data Sheet ...................................... 4
4. References................................................................................................ 4

71.000.001_A Page 2 of 4
Doc. nr: 72.120.301/A
Doc. name: FGM 160 - Weight Data Sheet

1. PURPOSE
This document specifies the weight of the components included in the Fluenta Flare
Gas Meter, FGM 160.

2. ABBREVIATIONS/DEFINITIONS
2.1 Abbreviations:
FGM 160 Fluenta Flare Gas Meter, model FGM 160
TFS Transducer Full Size
TCV Transducer Compact Version

2.2 Definitions:
EEx-d/e FGM 160 in EEx-d explosion proof enclosure and connection housing in
EEx-e enclosure.
EEx-d FGM 160 and connection housing in EEx-d explosion proof enclosure.

3. WEIGHT DATA SHEET


3.1 Transducer Full Size (TFS) Weight Data Sheet
Table 1 indicates the weight of an FGM 160 with up to two sensor pairs. The sensors
involved are Transducer Full Size (TFS) and the FGM 160 in an EEx-d/e housing. All
weights are listed in [kg] and [lbs].

Table 1 Transducer Full Size and EEx-d/e housing

Weight data Unit 1 system 2 systems


[kg] lbs [kg] [lbs] [kg] [lbs]
EEx d/e enclosure 17 37.5 17 37.5 17 37.5
Transducer FGM 160 10 22 20 44 40 88
Ball valve (typical) incl. bolts and
14 31 28 62 56 123
nuts
Transducer holder 5.5 12 11 24 22 48
Power cable 0.20 kg/m 0.13 lbs/ft
Complete system 76 167.5 135 296.5

Note! Cables are not included in the weight of the complete system as it
depends on the specific cable length, but weight per unit length is
indicated.

71.000.001_A Page 3 of 4
Doc. nr: 72.120.301/A
Doc. name: FGM 160 - Weight Data Sheet

Table 2 indicates the same weights as Table 1, but with the FGM 160 in a complete
EEx-d housing.

Table 2 Transducer Full Size and EEx-d housing

Weight data Unit 1 system 2 systems


[kg] [lbs] [kg] [lbs] [kg] [lbs]
EEx d enclosure 35 77.2 35 77.2 35 77.2
Transducer FGM 160 10 22 20 44 40 88
Ball valve (typical) incl. bolts and
14 31 28 62 56 123
nuts
Transducer holder 5.5 12 11 24 22 48
Power cable 0.20 kg/m 0.13 lbs/ft
Complete system 94 207.2 153 336.2

3.2 Transducer Compact Version (TCV) Weight Data Sheet


Table 3 indicates the weight of FGM 160 with Transducers Compact Version (TCV).
The FGM 160 in this table is a standard EEx-d/e housing.

Table 3 Transducer Compact Version and EEx-d/e housing

Weight data Unit 1 system 2 systems


[kg] [lbs] [kg] [lbs] [kg] [lbs]
EEX d/e enclosure 17 37.5 17 37.5 17 37.5
Transducer FGM 160 TCV/incl. 3.3/ 3.3/ 6.6/
1.5/3 1.5/3 3/6
adapter 6.6 6.6 13.2
Transducer holder incl. adapter 3.2 7 6.4 14.1 12.8 28.2
0.20
Power cable 0.13 lbs/ft
kg/m
Complete system, incl. adapters 26.4 58.2 35.8 78.9

Table 4 indicates the weight of a system with the FGM 160 in EEx-d housing.

Table 4 Transducer Compact Version and EEX-d housing

Weight data Unit 1 system 2 systems


[kg] [lbs] [kg] [lbs] [kg] [lbs]
EEX d/e enclosure 35 77.2 35 77.2 35 77.2
Transducer FGM 160 TCV/incl. 3.3/ 3.3/ 6.6/
1.5/3 1.5/3 3/6
adapter 6.6 6.6 13.2
Transducer holder incl. adapter 3.2 7 6.4 14.1 12.8 28.2
0.20
Power cable 0.13 lbs/ft
kg/m
Complete system, incl. adapters 44.4 97.9 53.8 118.6

4. REFERENCES
N/A.

71.000.001_A Page 4 of 4

You might also like