First-class professional Class I, Class II sound level meter
Features Technical data
· Ideal for measurements for workplaces · Time interval during measurement: F (fast), · Applicable standards: outdoor, e.g. at airports, on building sites, S (slow), I (pulse) IEC61672-1:2014-07 in road construction etc. with broad access · Freely-definable limits for the output of an GB/T3785.1–2010 to spectrum thanks to the highly-accurate optical alarm signal 1/1 Octavo in accordance with IEC 61260:2014 24-Bit A/D converter · Peak hold function to capture the peak · ½ inch microphone · Floating point evaluation for higher level of value · Permissible ambient temperature range accuracy and better stability · Octavo function for targeted sound -10 °C/50 °C · The optimised analogue frontend switch analysis · Output (direct or alternating current) reduces the ambient noise and increases the · TRACK function with graphic display of a · AC (max 5 VRMS), DC (10 mV/DB) linear measuring range measurement · Mains operation as standard · A specially-developed algorithm permits a · Calibration mode (with optional calibrator) · Battery operation, 4× 1.5V AA, not included, compliant dynamic range of more than · Data logging function with date and operating time up to 10 h 120 dB! (SW 1000: > 123 dB; SW 2000: > 122 dB) time in the device and data transfer using · Dimensions W×D×H 80×36×300 mm · Three profiles and 14 user-defined meas- MicroSD (4G) memory card (included with · Net weight approx. 400 g urements can be calculated in parallel with delivery), RS-232 or USB different frequency and time weighting · Trigger mode: Analogue signal to switch the Accessories · Different sound pressure levels can device on or off with 3.5 mm plug be selected, such as, Laeq, LcPeak, LaF, · Automatic measurement for timer · Plug-In for data transfer of measuring LaFMax, LaFMin, SD, SEL, E function is possible data from the measuring instrument and · LN statistics and display of the graph · Selectable frequency for recording transfer to a PC, e.g. in Microsoft Excel®, showing the progression of time measurements: 10, 5, 2 Hz SAUTER AFI-1.0 · User-defined integral interval meas- · Operating languages: GB, DE, FR, ES, PT · Stand, W×D×H 430×90×90 mm, urement up to a maximum of 24 hours is · Delivery in robust transport case 1250×750×750 mm (moved out), possible · Option of fitting a stand on the rear of the SAUTER SW-A05 · Frequency weighting (filter) A, B, C, Z housing, ¼" thread · SD-memory card, storage capacity 4 GB, SAUTER SW-A04 09 · Calibrator for regular adjustment of the sound level meter, SAUTER ASU-01 STANDARD OPTION · Foam draft shield, SAUTER SW-A03 SAUTER Catalogue 2018 | GB
Model Accuracy class Measuring Frequency Sensitivity Option Option
range range DAkkS calibration certificate Factory calibration certificates Linear SAUTER dB dB V/Pa KERN KERN SW 1000 1 22–136 0,003–20 kHz 50 m V/Pa 963-281 961-281 SW 2000 2 25–136 0,02–12,5 kHz 40 m V/Pa 963-281 961-281
Adjusting program (CAL): Control outputs Rechargeable battery pack:
For quick setting of the balance’s accuracy. (optocoupler, digital I/O): rechargeable set. External adjusting weight required. to connect relays, signal lamps, valves, etc.
standard for adjusting or correcting to connect a suitable peripheral device for 230V/50Hz in standard version for EU. the measuring device. analogue processing of the measurements. On request GB, AUS or USA version available. Peak hold function: Statistics: Power supply: capturing a peak value within a using the saved values, the device Integrated, 230V/50Hz in EU. measuring process. calculates statistical data, such as More standards e.g. GB, AUS average value, standard deviation etc. or USA on request. Scan mode: PC Software: Motorised drive: continuous capture and display to transfer the measurements from The mechanical movement is carried out of measurements. the device to a PC. by a electric motor.
Push and Pull: Printer: Motorised drive:
the measuring device can capture tension a printer can be connected to the The mechanical movement is carried out and compression forces. device to print out the measurements. by a synchronous motor (stepper).
Length measurement: GLP/ISO record keeping: Fast-Move:
captures the geometric dimensions of of measurements with date, time and the total length of travel can be covered a test object or the movement during serial number. Only with SAUTER printers. by a single lever movement. a test process. Focus function: Measuring units: DAkkS calibration possible: increases the measuring accuracy of a Weighing units can be switched to The time required for DAkkS calibration device within a defined measuring range. e.g. non-metric at the touch of a key. is shown in days in the pictogram. Please refer to website for more details. Internal memory: Measuring with tolerance range Factory calibration: to save measurements (limit-setting function): The time required for factory calibration in the device memory. Upper and lower limiting can be is specified in the pictogram. programmed individually. The process is supported by an audible or visual Data interface RS-232: signal, see the relevant model Package shipment: bidirectional, for connection The time required for internal shipping ZERO: preparations is shown in days in the of printer and PC. Resets the display to “0”. pictogram.
Data interface USB: Pallet shipment:
To connect the balance to a printer, The time required for internal Battery operation: PC or other peripheral devices. shipping preparations is shown Ready for battery operation. in days in the pictogram. The battery type is specified Data interface Infrared: for each device. To transfer data from the balance to a printer, PC or other peripheral devices.