Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

HERTZ INSPECTION & SERVICES PVT. LTD.

Doc # F/IR/001 Ver # 02 Date 09.09.2022

INSPECTION REPORT
Client M/s. Think Gas Begusarai Pvt. Ltd. Vendor M/s. Green Tech Cylinder Testing Co.

Hertz P.O. No. 5600000841/R, Date:-18/08/2022 Vendor P.O. No. 5500001111/R1 Dated 12/06/2023

Arazi No 382 GT Road Village Ahmadpur Asrauli


Project Not Applicable. Inspection address
Near Tiwari Talab, Prayagraj, 212208

Inspection report No. TGBPL/GTCTCPL/MUNNA/07-23/001 Date of Report 20/07/2023

Date of Inspection Visits 10/07/2023 to 15/07/2023 P.O. Complete Yes

Result of Inspection Pass Any Non conformity No


Next Visit required for
Is sampling done Yes No
below items
DETAIL OF MATERIAL INSPECTED
Non
ID No. of Item
Qty. Offered Qty. Inspected Satisfactory Qty Satisfactory Item Description
Inspected
Qty.
H4C75B 20567, H4C75B Hydrotesting of CNG Cylinders
40 Nos. 20585, H4C75B 20561, 4 Nos. 4 Nos. 0 Cascade (Cascade No.
H4C75B 20558 EKCK/THINK GAS/40/255-27)
Inspection done at above location, where Inspection carried out 10% per cascade as per approved QAP for Hydro
testing of CNG Cascade Cylinders (EKCK/THINK GAS/40/255-27). Inspection found accepted as per approved QAP and
Inspection Summary :
Gas Cylinder Rules 2008.

Person Present : Name Designation Name of Organisation


Hertz Inspector Mr. Munna Ansari Inspection Engineer Hertz Inspection & Services Pvt. Ltd.
Vendor Mr.Neeraj Kumar Manager M/s. Green Tech Cylinder Testing Co.
Client
REFERENCE DOCUMENTS :
Document No. Rev. No. If applicable Name of Document
Rev. 0,
QAP/CASCADE RETESTING QAP
Date-06/01/2023
5500001111/R1 N.A. P.O.
REVIEWED DOCUMENTS :
Rev. No. If
Document No. Name of Document
applicable
Calibration Certificate No. PCTS/PG/29415 N.A. Calibration Certificate for Pressure Gauge
Calibration Certificate No. PCTS/PG/29416 N.A. Calibration Certificate for Pressure Gauge
Calibration Certificate No. PCTS/PG/29417 N.A. Calibration Certificate for Pressure Gauge
Calibration Certificate No. PCTS/PG/29419 N.A. Calibration Certificate for Pressure Gauge
Calibration Certificate No. PCTS/WBAL/29414 N.A. Calibration Certificate for Pressure Gauge
Calibration Certificate No. 3/4908/03 N.A. Calibration Certificate for Thread Ring Gauge
Calibration Certificate No. 2023/179 N.A. Calibration Certificate for Coating Thickness Gauge
Calibration Certificate No. ACS/PRG/501314 N.A. Calibration Certificate for Pressure Gauge
Calibration Certificate No. ACS/UTG/501316 N.A. Calibration Certificate for Ultrasonic Thickness Gauge
Calibration Certificate No. ACS/WBAL/501317 N.A. Calibration Certificate for Digital Weighing Balance
Calibration Certificate No. ACS/PRG/501310 N.A. Calibration Certificate for Pressure Gauge (Master Gauge)
Calibration Certificate No. ACS/PRG/501311 N.A. Calibration Certificate for Pressure Gauge (Master Gauge)
Calibration Certificate No. ACS/PRG/501312 N.A. Calibration Certificate for Pressure Gauge
Calibration Certificate No. ACS/PRG/501313 N.A. Calibration Certificate for Pressure Gauge
Cylinder Test Certiifcate for Cascade No. EKCK/THINK
N.A. Cylinder Test Certificate
GAS/40/255-27
Review Report for Thickness Measurement of CNG Cylinders, Hydro Testing
Review Report for 36 Nos. of Cylinders included in
N.A. of CNG Cylinders, Shot Blasting, Primer Coating & Paint Coating for CNG
Cascade No. EKCK/THINK GAS/40/255-27
Cylinder, Pneumatic Testing of CNG Cylinders
HERTZ INSPECTION & SERVICES PVT. LTD.
Doc # F/IR/001 Ver # 02 Date 09.09.2022

INSPECTION REPORT
WITNESSED REPORTS M/s. Think Gas Begusarai Pvt. Ltd. M/s. Green Tech Cylinder Testing Co.
Document No. Rev. No. If applicable Name of Document
Witness Report for Thickness Measurement of CNG Cylinders, Hydro Testing of CNG Cylinders,
N.A. N.A. Shot Blasting, Primer Coating & Paint Coating for CNG Cylinder, Pneumatic Testing of CNG
Cylinders
INSPECTION ACTIVITIES :
ACTIVITIES WITNESSED BY INSPECTOR
Qty Inspected / ID No. Description of item Description of Activity Pass/Fail/Remark
4 Nos., Cylinder No. H4C75B
20567, H4C75B 20585, H4C75B CNG Cascade Cylinders Wall Thickness of CNG Cascade Cylinders Satisfactory
20561, H4C75B 20558

4 Nos., Cylinder No. H4C75B


20567, H4C75B 20585, H4C75B CNG Cascade Cylinders Hydro Testing of CNG Cascade Cylinders Satisfactory
20561, H4C75B 20558

4 Nos., Cylinder No. H4C75B


Surface Prepration & Coating Thickness of Paint for CNG
20567, H4C75B 20585, H4C75B CNG Cascade Cylinders Satisfactory
Cascade Cylinders
20561, H4C75B 20558
4 Nos., Cylinder No. H4C75B
20567, H4C75B 20585, H4C75B CNG Cascade Cylinders Pneumatic Testing of CNG Cascade Cylinders Satisfactory
20561, H4C75B 20558
Pressure
TYPE OF TEST ID No. Test Pressure - Bar Hold Time (min.) Result
Gauge No.

H4C75B 20567, H4C75B


Hydro test 20585, H4C75B 20561, 425 Bar 30 Second 200807 Satisfactory
H4C75B 20558

H4C75B 20567, H4C75B


Pneumatic test 20585, H4C75B 20561, 255 Bar 30 Minute 194212 Satisfactory
H4C75B 20558

VISUAL INSPECTION
Qty inspected / ID No. Description of Item Result Inspector's Observation
36 Nos. of Cylinders included in
Cascade No. EKCK/THINK CNG Cascade Cylinders Satisfactory Visual Inspection carried out for CNG Cascade and
GAS/40/255-27 It was found satisfactory.
DIMENSION VERIFICATION :
Satisfactory / Non
Qty inspected / ID No. Description of Item Satisfactory / Not Which dimensions checked ( e.g. O.D., thickness)
Applicable
Dimesinsion verification not applicable for this item
OTHER INSPECTION ACTIVITIES CARRIED OUT : Not Applicable

LIST AND CALIBRATION DETAILS OF MEASURING EQUIPMENT USED :

Sr. No. DESCRIPTION ID NO. RANGE CALIBRATION DATE

1 Pressure Gauge 200806 0 to 600 Bar 09.04.2023


2 Pressure Gauge 200807 0 to 600 Bar 09.04.2023
3 Pressure Gauge 194212 0 to 600 Bar 09.04.2023
4 Pressure Gauge 203572 0 to 600 Bar 09.04.2023
5 Digital Weight Machine GTCTC/DWM/01 0 to 400 Kg 09.04.2023
6 Thread Ring Gauge XB-1294 N.A. 23.02.2023
Coating Thickness Gauge 2204EC448673 N.A. 25.02.2023
7
8 Pressure Gauge PIPL-14030278 0 to 600 Bar 11.02.2023
Ultrasonic Thickness
JI2148937 5 to 225 mm 11.02.2023
9 Gauge
10 Digital Weight Balance 150008 0 to 300 Kg 11.02.2023
Pressure Gauge (Master
6DA06010 0 to 700 Bar 11.02.2023
11 Gauge)
Pressure Gauge (Master
6DA71162 0 to 700 Bar 11.02.2023
12 Gauge)
13 Pressure Gauge PIPL-14030026 0 to 600 Bar 11.02.2023
14 Pressure Gauge PIPL-14032518 0 to 600 Bar 11.02.2023
HERTZ INSPECTION & SERVICES PVT. LTD.
Doc # F/IR/001 Ver # 02 Date 09.09.2022

INSPECTION REPORT
NON CONFORMITY : M/s. Think Gas Begusarai Pvt. Ltd. Nill M/s. Green Tech Cylinder Testing Co.
CONCLUSION : Based on above mentioned inspection activities, inspected items are found satisfactory.
IDENTIFICATION OF INSPECTED ITEMS/ MARKING OF INSPECTION :
Inspected items are identified with sticker of Hertz as with Signature of Inspection Engineer.

ENCLOSURES :
SR.NO. DOCUMENT NO. REV. No. NAME OF DOCUMENT

Calibration Certificate
1 N.A. Calibration Certificate for Pressure Gauge
No. PCTS/PG/29415

Calibration Certificate
2 N.A. Calibration Certificate for Pressure Gauge
No. PCTS/PG/29416

Calibration Certificate
3 N.A. Calibration Certificate for Pressure Gauge
No. PCTS/PG/29417

Calibration Certificate
4 N.A. Calibration Certificate for Pressure Gauge
No. PCTS/PG/29419

Calibration Certificate
5 N.A. Calibration Certificate for Pressure Gauge
No. PCTS/WBAL/29414

Calibration Certificate
6 N.A. Calibration Certificate for Thread Ring Gauge
No. 3/4908/03

Calibration Certificate
7 N.A. Calibration Certificate for Coating Thickness Gauge
No. 2023/179

Calibration Certificate
8 N.A. Calibration Certificate for Pressure Gauge
No. ACS/PRG/501314

Calibration Certificate
9 N.A. Calibration Certificate for Ultrasonic Thickness Gauge
No. ACS/UTG/501316

Calibration Certificate
10 N.A. Calibration Certificate for Digital Weighing Balance
No. ACS/WBAL/501317

Calibration Certificate
11 N.A. Calibration Certificate for Pressure Gauge (Master Gauge)
No. ACS/PRG/501310

Calibration Certificate
12 N.A. Calibration Certificate for Pressure Gauge (Master Gauge)
No. ACS/PRG/501311

Calibration Certificate
13 N.A. Calibration Certificate for Pressure Gauge
No. ACS/PRG/501312

Calibration Certificate
14 N.A. Calibration Certificate for Pressure Gauge
No. ACS/PRG/501313

Cylinder Test Certiifcate


for Cascade No.
15 N.A. Cylinder Test Certificate
EKCK/THINK
GAS/40/255-27

Review Report 36 Nos.


of Cylinders included in
Review Report 36 Nos. of Cylinders included in Cascade No. EKCK/THINK
16 Cascade No. N.A.
GAS/40/255-27
EKCK/THINK
GAS/40/255-27
HERTZ INSPECTION & SERVICES PVT. LTD.
Doc # F/IR/001 Ver # 02 Date 09.09.2022

INSPECTION REPORT
M/s.Report
Witness Think Gas
for 4Begusarai Pvt. Ltd. M/s. Green Tech Cylinder Testing Co.
Nos. of Cylinders
Witness Report for 4 Nos. of Cylinders included in Cascade No. EKCK/THINK
17 included in Cascade No. N.A.
GAS/40/255-27
EKCK/THINK
GAS/40/255-27
Inspection Engineer Mr. Munna Ansari Approved By Mr. Jignesh Darji

Sign and Stamp Sign and Stamp

Date 20/07/2023 Date 20/07/2023


PHOTOGRAPHIC EVIDENCE OF INSPECTION :

Wall Thickness of CNG Cascade Cylinder Pneumatic Testing of CNG Cascade Cylinder

Thread Verification of CNG Cascade Cylinder

Hydro Test check of CNG Cascade Cylinder Surface Preparation checked of CNG Cascade Cylinder
---End of Report---